Search results for "24�üҾױ������� �Ų� banonpi �ٳ��� �������ɳ����� �ɸ��Թ��� �۾��������ſ� �������� �ź��ڻ����ڱݴ�������"
-
MS-25-2.5-415V, Motor Protection Switch, 3 Phase, 690VAC, 1.6 - 2.5 Amp Setting Range, Thermal and Magnetic Release, with 415V Coil
Iskra Doo MS-25-2.5-415V, Motor Protection Switch, 3 Phase, 690VAC, 1.6 - 2.5 Amp Setting Range, Thermal and Magnetic Release, with 415V Coil Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MS-25-2.5-415V Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 1.6 - 2.5 Amp RMS Coil Voltage 400/415VAC Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet Alternatives Trent FGV2 Series
$89.00
$105.02 inclGST -
TGD-4PL C 25-10kA, 4 Pole Miniature Bidirectional DC Circuit Breaker C Curve 25 Amp, 10kA, 1000VDC
TRENT TGD-4PL C 25-10kA, 4 Pole Miniature Bidirectional DC Circuit Breaker C Curve 25 Amp, 10kA, 1000VDC Miniature DC Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : < 50mS Trip Delay Time 4 Pole Disconnect 10kA Short Circuit Rating Suitable for Isolation Customised versions available Type C, D Curve available Bidirectional Standards : IEC/EN 60898 IEC/EN/AS60898-1 IP20 (IP40 Installed) IEC 61008 CE,CB, RCM (Pending) Specification TRENT Part Number TGD-4PL C 25-10kA Functions 4 Pole MCB - C Curve Nominal Voltage 1000VDC @ 50/60Hz Nominal Current Range 25 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 6kV Operating Temperature -25 to 40 Deg C Mechanical Operations 10,000 Ops Insulation Voltage 690V Breaking Capacity 10kA Approvals CE,CB, RCM (Pending) Standards IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ; Weight 350g Enclosure Material UL94 Factory Pack Qty 1 TRENT Headquarters Australia Datasheet Product Datasheet
$59.50
$70.21 inclGST -
HO 25-NP-0000 Kit 5P, Evaluation Kit 5pcs with PCB
Free Aus Post Shipping for $300 SpendLEM HO 25-NP-0000 Kit 5P Series Open Loop AC/DC Hall Effect Sensor Features Open loop multi-range current transducer Multi range through PCB routing Voltage output Single power supply +5 V Overcurrent detect 2.93 × IP N (peak value) Galvanic separation between primary and secondary circuit Low power consumption Compact design for THT PCB mounting Factory calibrated Dedicated parameter settings available on request (see page 12) Advantages Low offset drift Over-drivable Vref Creepage / clearance > 8 mm Fast response Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box Solar inverter on DC side of the inverter (MPPT). Standards IEC 61800-1: 1997 IEC 61800-2: 2015 IEC 61800-3: 2004 IEC 61800-5-1: 2007 IEC 62109-1: 2010 UL 508: 2013. Application Domain Industrial. Specification LEM Part Number HO 25-NP-0000 Technology Open Loop Hall Effect Aperture N/A ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 25 Amp Measurement Range +/-62.5 Amp Output 2.5 Vref Isolation 4.3 kV Bandwidth DC-250 kHz Mounting Style Surface Mount Operating Temperature Range -40°C / 105°C Accuracy 1% Termination Style PCB Surface Mount Unit Weight 34g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
LV 25-800, C/L Voltage Transducer, 800V, 25mA Output
Free Aus Post Shipping for $300 SpendLEM LV Series Closed Loop AC/DC Hall Effect Voltage Sensor Features Bandwidth DC to 40kHz Multi Range through pin selection Closed loop transducer using Hall effect Compact and versatile Panel Mount Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses Voltage overload capability Low power consumption Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number LV 25-800 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-12..15 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) 800V Measurement Range 0 - 1200V Output 25 mA @Vpn Isolation 4.1 kV Bandwidth DC-40 kHz Mounting Style PCB Mount Operating Temperature Range -40°C / 70°C Accuracy 0.8% Termination Style Fastron 6.3 x 0.8mm Unit Weight 60g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
MS-25-0.25, Motor Protection Switch, 3 Phase, 690VAC, 0.16 - 0.25 Amp Setting Range, Thermal and Magnetic Release
Free Aus Post Shipping for $300 SpendIskra Doo MS-25-0.25, 3 Phase Motor Protection Switch Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MS-25-0.25 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 0.16 - 0.25 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet Alternatives Trent FGV2 Series
-
MS-25-20, Motor Protection Switch, 3 Phase, 690VAC, 16 - 20 Amp Setting Range, Thermal and Magnetic Release
Free Aus Post Shipping for $300 spendIskra Doo MS-25-20, Motor Protection Switch, 3 Phase, 690VAC, 16 - 20 Amp Setting Range, Thermal and Magnetic Release Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines, agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MS-25-20 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 16 - 20 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet Alternatives Trent FGV2 Series
-
Thyro ECO A3A 400-25 E L3, 3 Phase, SCR Controller 25 Amp Rating, Phase(VAR), Burst(TAKT), Switch Operating Mode, Voltage Control only
Advanced Energy Thyro ECO A3A 400-25 E L3, 3 Phase, SCR Controller 25 Amp Rating, Phase(VAR), Burst(TAKT), Switch Operating Mode, Voltage Control only Features 400VAC +10/-57% Line to Line Voltage Control Programmable Relay Alarm Output 3 Phase, Phase Angle, Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Fully enclosed IP20 Phase Angle(VAR), and Burst Fire(TAKT) switching Removable Cover USB Configuration/Bias Setting Synchronisation Function Digital Alarm Output Load Monitoring Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode AC Soft Starter (Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Special Features Economic Model Specification Advanced Energy Part Number Thyro ECO A3A 400-25 E L3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C SCR Configuration 3 Phase AC Switch Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 25 to 125 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-57% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 10kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$2,598.75
$3,066.53 inclGST -
MS-25-0.63, Motor Protection Switch, 3 Phase, 690VAC, 0.4 - 0.63 Amp Setting Range, Thermal and Magnetic Release
Free Aus Post Shipping for $300 SpendIskra Doo MS-25-0.63, 3 Phase Motor Protection Switch Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MS-25-0.63 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 0.4 - 0.63 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet Alternatives Trent FGV2 Series
-
MS-25-0.16, Motor Protection Switch, 3 Phase, 690VAC, 0 - 0.16 Amp Setting Range, Thermal and Magnetic Release
Free Aus Post Shipping for $300 SpendIskra Doo MS-25-0.16, 3 Phase Motor Protection Switch Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MS-25-0.16 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 0 - 0.16 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet Alternatives Trent FGV2 Series
-
MST-25-0.63, Motor Protection Switch, 3 Phase, 690VAC, 0.4 - 0.63 Amp Setting Range, Thermal Release Only
Free Aus Post Shipping for $300 SpendIskra Doo MST-25-0.63, 3 Phase Motor Protection Switch Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and short circuit. Used in industry, small machines, agricultural machines, compressors etc. Features : Thermal release < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MST-25-0.63 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 0.4 - 0.63 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal Release Only Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet Alternatives Trent FGV2 Series
-
MST-25-25, Motor Protection Switch, 3 Phase, 690VAC, 20 - 25 Amp Setting Range, Thermal Release only
Free Aus Post Shipping for $300 SpendIskra Doo MST-25-25, 3 Phase Motor Protection Switch Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and short circuit. Used in industry, small machines, agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MST-25-25 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 20 - 25 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal Release Only Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet Alternatives Trent FGV2 Series
-
MST-25-0.25, Motor Protection Switch, 3 Phase, 690VAC, 0.16 - 0.25 Amp Setting Range, Thermal Release Only
Free Aus Post Shipping for $300 SpendIskra Doo MST-25-0.25, 3 Phase Motor Protection Switch Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and short circuit. Used in industry, small machines, agricultural machines, compressors etc. Features : Thermal release < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MST-25-0.25 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 0.25 - 0.4 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal Release Only Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet Alternatives Trent FGV2 Series