Relequick Socket Q4 for Slimline Relays
Features
6 Amp @ 60VDC/300VAC
DIN Rail Mount
Changeover Contact
Ultra slim package
CE Compliant to IEC 60664
IP67
Specification
Relequick Part Number
SQB41D00T
Switching Type
AC or DC Load
ROHS
Yes (Details)
Termination Style
Screw
Unit Weight
38g
Factory Pack Qty
20
Datasheet
Base Datasheet
Suitable Parts
240VAC Relay
24VDC Relay
RCS-1205-VAR, 5 Amp Output, Class 1 Three Phase 500/1000/2500/5000\10000\25000\50000 Amp AC Measurement 4 Inch Diameter Rogowski Coils with Integrator Flexible Current Sensor System:
The RCS-1205 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 5 Amp.
A 24VDC Power Supply is included to operate these coils. The RCS-1205 comes with 5 Amp integrator..
Included is an 12 inch circumference rope CT with Integrator, and power supply.
Magnelab Coils come with 10 year warranty
Specification
Magnelab Part Number
RCS-1205-VAR
Function
AC Current Measurement
Nominal Measurement Current (Ipn)
500/1000/2500/5000\10000\25000\50000 Amp RMS Selectable
Measurement Range
10% - 130% if Ipn
Outptu Range
0-5 Amp
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
24VDC
Accuracy
1% from 25 to 5000 Amp
Phase Angle
< 0.5 Degrees
Coil Diameter (⌀)
4 Inch
Coil Circumference
12 Inch
Integrator to Coil Cable
8 Feet Shielded
Maximum Voltage
600V (on bare conductor)
Operating Temperature
-15°C to 65°C
Storage Temperature
-45°C to 80°C
Power Consumption
< 2VA
Overload
20,000 Amp (continuous)
Termination Style
Screw
Weight
2000g
Certification
CE
Factory Pack Qty
1
Certifications
UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1
Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010
CE
ROHS
Datasheet
Product Datasheet
Application Notes
RCS-VAR Series Installation Guide
RCS-4805-VAR, 5 Amp Output, Three Phase 500/1000/2500/5000\10000\25000\50000 Amp AC Measurement 16 Inch Diameter Rogowski Coils with Integrator Flexible Current Sensor System (Rogowski Coils):
The RCS-4805 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 5 Amp.
A 24VDC Power Supply is included to operate these coils. The RCS-4805 comes with 5 Amp integrator..
Included is an 48 inch circumference, 16 inch diameter rope CT with Integrator, and power supply.
Magnelab Coils come with 10 year warranty
Specification
Magnelab Part Number
RCS-4805-VAR
Function
AC Current Measurement
Nominal Measurement Current (Ipn)
500/1000/2500/5000\10000\25000\50000 Amp RMS Selectable
Measurement Range
10% - 130% if Ipn
Output Range
0-5 Amp
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
24VDC
Accuracy
1% from 25 to 5000 Amp
Phase Angle
< 0.5 Degrees
Coil Diameter (⌀)
16 Inch
Coil Circumference
48 Inch
Integrator to Coil Cable
8 Feet Shielded
Maximum Voltage
600V (on bare conductor)
Operating Temperature
-15°C to 65°C
Storage Temperature
-45°C to 80°C
Power Consumption
< 2VA
Overload
20,000 Amp (continuous)
Termination Style
Screw
Weight
3500g
Certification
CE
Factory Pack Qty
1
Certifications
UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1
Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010
CE
ROHS
Datasheet
Product Datasheet
Application Notes
RCS-VAR Series Installation Guide
Manual Battery Switch, DPST 2 x 500 Amp 32VDC, Flange Mount 120mm Wide, M10 Terminations, IP67/IEC529
DC battery switches are designed to be placed in between the battery and load. Suitable for any low voltage DC application which requires up to 2kA overload for 1.5 minutes.
Features :
2 Pole Disconnect
Suitable for DC Isolation
Standards :
IEC 60364-7-712
IP65 (Front) IP20 (Terminals)
Specification
Gigavac Part Number
BD9513
Functions
2 Pole DC DPST Disconnect Switch, ON/OFF Red Lever
Nominal Voltage
32VDC
Nominal Current
2 x 500 Amp DC
Rated Impulse Voltage
1.05kV (1 min)
Rated Insulation Voltage
32VDC
Short Circuit Current
2kA (1.5 min), 2.5kA (10s)
Mounting
Outdoor/Indoor Panel Mount
Panel Size
N/A
Standards
IP67/IEC529
Termination
M10
Weight
700g
Enclosure Material
Zytel
Factory Pack Qty
10
Datasheet
Product Datasheet
Crydom PMP4850WP, Phase/Burst control, 240VAC, 50 Amp, Selectable 0-5V,0-10V,4-20mA Input, w/Overvoltage Protection
Features
Selectable Proportional Phase or Burst Control Input
Ratings from 25A to 90 Amp @ 170-600 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
PMP4850WP
Switching Type
Phase Angle or Burst (Selectable)
ROHS/CE/UL
Yes
Control Voltage
0 - 10V/0 - 5V/4 - 20mA Proportional Input (Selectable)
Note Requires DC Power Supply for 0-5V/0-10V input modes
Load Current
50 Amp (rms)
Surge Capability
716Amp (peak)
Special Feature
Proportional Controller + SSR, Overvoltage protection
Mounting Style
Panel Mount
Load Voltage Range
345-530VAC
Dielectric Strength
4kV
Termination Style
Terminal Plug
Unit Weight
160g
Factory Pack Qty
20
Datasheet
Product Datasheet
PMP24 Installation/Wiring Guide
Equivalent
Crydom PMP2425W or Contact Us for Possible Replacement
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
LEM DVL 1000 UI Digital Voltage Transducer 1000V Input, 4-20mA output, +/- 15V…24VDC, 8.5kV Isolation
Features
Bandwidth DC to 14kHz
Multi Range through pin selection
Closed loop transducer using Hall effect
Compact and versatile
Panel Mount
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Voltage overload capability
Low power consumption
Applications
Railway substation or locomotive
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Water Treatment Electronics
Specification
LEM Part Number
DVL 1000 UI
Technology
Closed Loop Hall Effect
Aperture
No Aperture
ROHS
Yes
Supply Voltage
+/-15..24 VDC Bipolar, Isolated
Primary Nominal Voltage (RMS + DC)
+/- 1000V
Measurement Range
+/- 1500V
Output
4 - 20mA
Isolation
8.5 kV
Bandwidth
DC-14 kHz
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 70°C
Accuracy
1%
Termination Style
M5 Screw
Unit Weight
270g
Factory Pack Quantity
4
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Schurter 0090.0001 ASO 10.3x38mm GpV Fast Blow Solar Fuse 1Amp, 1000VDC, 20kA, IEC 61730-2
Features
Meets the new UL and IEC photovoltaic standards
UL Recognized for 1000 VDC
High breaking capacity of 20 kA @ 1000 VDC
Low min. interrupting rating of 1.35 x In
Meets the requirements of IEC 61730-2 for PV module safety
Applications
All photovoltaic applications
Inverters
Battery charge controllers
In-line protection
String fuses
Specification
Schurter Part Number
0090.0001
Fuse Type
I²t GpV Class Fast Blow
Nominal Voltage
1000VDC
I²t Rating (Pre-Arcing)
554 A²/s
Nominal Current (DC)
1 Amp
Tested Breaking Capacity
20kA @1000VDC
Dimensions
10.3 x 38mm
Fuse Holder
FSO Fuse Holders
Mounting Style
Requires fuse holder
Operating Temperature Range
-40°C / 125°C
Watt Loss
0.6W
DC Breaking Capacity
20kA
Unit Weight
8g
Factory Pack Qty
10
Datasheet
Product Datasheet
Fuse Holder
FSO Fuse Holders
Schurter 0090.0012 ASO 10.3x38mm GpV Fast Blow Solar Fuse 12Amp, 1000VDC, 20kA, IEC 61730-2
Features
Meets the new UL and IEC photovoltaic standards
UL Recognized for 1000 VDC
High breaking capacity of 20 kA @ 1000 VDC
Low min. interrupting rating of 1.35 x In
Meets the requirements of IEC 61730-2 for PV module safety
Applications
All photovoltaic applications
Inverters
Battery charge controllers
In-line protection
String fuses
Specification
Schurter Part Number
0090.0012
Fuse Type
I²t GpV Class Fast Blow
Nominal Voltage
1000VDC
I²t Rating (Pre-Arcing)
642 kA²/s
Nominal Current (DC)
12 Amp
Tested Breaking Capacity
20kA @1000VDC
Dimensions
10.3 x 38mm
Fuse Holder
FSO Fuse Holders
Mounting Style
Requires fuse holder
Operating Temperature Range
-40°C / 125°C
Watt Loss
1.97W
DC Breaking Capacity
20kA
Unit Weight
8g
Factory Pack Qty
10
Datasheet
Product Datasheet
Fuse Holder
FSO Fuse Holders
Schurter 0090.0025 ASO 10.3x38mm GpV Fast Blow Solar Fuse 30Amp, 1000VDC, 20kA, IEC 61730-2
Features
Meets the new UL and IEC photovoltaic standards
UL Recognized for 1000 VDC
High breaking capacity of 20 kA @ 1000 VDC
Low min. interrupting rating of 1.35 x In
Meets the requirements of IEC 61730-2 for PV module safety
Applications
All photovoltaic applications
Inverters
Battery charge controllers
In-line protection
String fuses
Specification
Schurter Part Number
0090.0030
Fuse Type
I²t GpV Class Fast Blow
Nominal Voltage
1000VDC
I²t Rating (Pre-Arcing)
2679 kA²/s
Nominal Current (DC)
30 Amp
Tested Breaking Capacity
20kA @1000VDC
Dimensions
10.3 x 38mm
Fuse Holder
FSO Fuse Holders
Mounting Style
Requires fuse holder
Operating Temperature Range
-40°C / 125°C
Watt Loss
3.92W
DC Breaking Capacity
20kA
Unit Weight
8g
Factory Pack Qty
10
Datasheet
Product Datasheet
Compatible Fuse Holder
FSO Fuse Holders
Fastron H31/110M-B + A53TP50D, Three Phase Solid State Relay with Heatsink 4-32VDC Control, 3 x 34Amp, 48-530VAC Load
Ratings from 25 to 120 Amp @ 70-480 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
IP20 Cover Included
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Specification
Fastron Part Number
H31/110M-B + A53TP50D
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
90-280VAC
Load Current
3 x 34 Amp (rms)
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
Panel Mount
Dimensions
L:110 x W:125 x D:180mm
Load Voltage Range
70-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
2kg
Factory Pack Qty
10
Datasheet
Product Datasheet
H31 Datasheet
Fastron HS103DR-FTH6053ZA4, Three Phase Solid State Relay 90-280VAC Control, 3 x 21Amp, 48-530VAC Load, LED Status Indicator, with IP20 Cover
Ratings from 25A to 70 Amp @ 70-530 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Approved
IP20 Cover Available
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Includes IP20 Cover
Specification
Crydom Part Number
HS103DR + FTH6053ZD3
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
90-280VAC
Load Current
3 x 23 Amp (rms) per Phase
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator, with IP20 Cover
Mounting Style
Din Rail Mount
Load Voltage Range
70-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
900g
Factory Pack Qty
10
Datasheet
HS103DR
Product Datasheet