Iskra Doo RI61J C 6-10kA, 1 Pole DC Miniature Circuit Breaker Disconnect Switch C Curve 6 Amp, 220VDC, 4.5kA
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
< 50mS Trip Delay Time
1 Pole Disconnect
4.5kA Short Circuit Rating
Suitable for Isolation
Customised versions available
Type B, C, D Curve available
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Iskra Doo Part Number
RI61J C6
Functions
1 Pole MCB - C Curve
Nominal Voltage
220VDC
Nominal Current Range
6 Amp RMS
Trip Delay Time
< 50ms
Rated Frequency
50/60 Hz
Operating Temperature
-25 to 55 Deg C
Rated Operations
10,000 Ops
Surge Current
220V
Short Circuit Current
4.5kA
Approvals
VDE, GOST-R
Standards
IEC/EN 60898,60947-1/2, IP20 (IP40 Installed) IEC 61008 ;
Weight
130g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Iskra Doo RI61J C 25-10kA, 1 Pole DC Miniature Circuit Breaker Disconnect Switch C Curve 25 Amp, 220VDC, 10kA
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
< 50mS Trip Delay Time
1 Pole Disconnect
10kA Short Circuit Rating
Suitable for Isolation
Customised versions available
Type B, C, D Curve available
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Iskra Doo Part Number
RI61J C25
Functions
1 Pole MCB - C Curve
Nominal Voltage
220VDC
Nominal Current Range
25 Amp RMS
Trip Delay Time
< 50ms
Rated Frequency
50/60 Hz
Operating Temperature
-25 to 55 Deg C
Rated Operations
10,000 Ops
Surge Current
220V
Short Circuit Current
10kA
Approvals
VDE, GOST-R
Standards
IEC/EN 60898,60947-1/2, IP20 (IP40 Installed) IEC 61008 ;
Weight
130g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Iskra Doo RI61J C 16-10kA, 1 Pole DC Miniature Circuit Breaker Disconnect Switch C Curve 16 Amp, 220VDC, 10kA
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
< 50mS Trip Delay Time
1 Pole Disconnect
10kA Short Circuit Rating
Suitable for Isolation
Customised versions available
Type B, C, D Curve available
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Iskra Doo Part Number
RI61J C16
Functions
1 Pole MCB - C Curve
Nominal Voltage
220VDC
Nominal Current Range
16 Amp RMS
Trip Delay Time
< 50ms
Rated Frequency
50/60 Hz
Operating Temperature
-25 to 55 Deg C
Rated Operations
10,000 Ops
Surge Current
220V
Short Circuit Current
10kA
Approvals
VDE, GOST-R
Standards
IEC/EN 60898,60947-1/2, IP20 (IP40 Installed) IEC 61008 ;
Weight
130g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Iskra Doo RI61J C 32-10kA, 1 Pole DC Miniature Circuit Breaker Disconnect Switch C Curve 32 Amp, 220VDC, 10kA
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
< 50mS Trip Delay Time
1 Pole Disconnect
10kA Short Circuit Rating
Suitable for Isolation
Customised versions available
Type B, C, D Curve available
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Iskra Doo Part Number
RI61J C32
Functions
1 Pole MCB - C Curve
Nominal Voltage
220VDC
Nominal Current Range
32 Amp RMS
Trip Delay Time
< 50ms
Rated Frequency
50/60 Hz
Operating Temperature
-25 to 55 Deg C
Rated Operations
10,000 Ops
Surge Current
220V
Short Circuit Current
10kA
Approvals
VDE, GOST-R
Standards
IEC/EN 60898,60947-1/2, IP20 (IP40 Installed) IEC 61008 ;
Weight
130g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Iskra Doo RI61J C 63-10kA, 1 Pole DC Miniature Circuit Breaker Disconnect Switch C Curve 63 Amp, 220VDC, 10kA
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
< 50mS Trip Delay Time
1 Pole Disconnect
10kA Short Circuit Rating
Suitable for Isolation
Customised versions available
Type B, C, D Curve available
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Iskra Doo Part Number
RI61J C63
Functions
1 Pole MCB - C Curve
Nominal Voltage
220VDC
Nominal Current Range
63 Amp RMS
Trip Delay Time
< 50ms
Rated Frequency
50/60 Hz
Operating Temperature
-25 to 55 Deg C
Rated Operations
10,000 Ops
Surge Current
220V
Short Circuit Current
10kA
Approvals
VDE, GOST-R
Standards
IEC/EN 60898,60947-1/2, IP20 (IP40 Installed) IEC 61008 ;
Weight
130g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Iskra Doo RI62J C 25-4.5kA, 2 Pole DC Miniature Circuit Breaker Disconnect Switch C Curve 25 Amp, 440VDC, 4.5kA
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
< 50mS Trip Delay Time
1 Pole Disconnect
4.5kA Short Circuit Rating
Suitable for Isolation
Customised versions available
Type B, C, D Curve available
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Iskra Doo Part Number
RI62J C25
Functions
2 Pole MCB - C Curve
Nominal Voltage
440VDC
Nominal Current Range
25 Amp RMS
Trip Delay Time
< 50ms
Rated Frequency
50/60 Hz
Operating Temperature
-25 to 55 Deg C
Rated Operations
10,000 Ops
Surge Current
500V
Short Circuit Current
4.5kA
Approvals
VDE, GOST-R
Standards
IEC/EN 60898,60947-1/2, IP20 (IP40 Installed) IEC 61008 ;
Weight
130g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Iskra Doo RI62J C 50-4.5kA, 2 Pole DC Miniature Circuit Breaker Disconnect Switch C Curve 50 Amp, 440VDC, 4.5kA
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
< 50mS Trip Delay Time
1 Pole Disconnect
4.5kA Short Circuit Rating
Suitable for Isolation
Customised versions available
Type B, C, D Curve available
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Iskra Doo Part Number
RI62J C50
Functions
2 Pole MCB - C Curve
Nominal Voltage
440VDC
Nominal Current Range
50 Amp RMS
Trip Delay Time
< 50ms
Rated Frequency
50/60 Hz
Operating Temperature
-25 to 55 Deg C
Rated Operations
10,000 Ops
Surge Current
500V
Short Circuit Current
4.5kA
Approvals
VDE, GOST-R
Standards
IEC/EN 60898,60947-1/2, IP20 (IP40 Installed) IEC 61008 ;
Weight
200g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
F923 Series AC Current Transducer with Process Outputs & High and Low C/O Alarm
Features
Isolated measurement of AC currents using internal Hall effect transducer.
Incorporates an integrated input level display and power supply.
Wide measurement range available
Choice of standard outputs
Wide range isolated DC input supply
DIN Rail mounting
Signal Conditioned AC measurement output
On board bar graph display
User adjustable zero offset and span controls
Zero insertion loss in current measurement path
Earth leakage via differential Ipn for nominal Input ‘01’
Applications
Process control
Transportation
Petrochemical
Industrial
Earth Leakage
Energy Monitoring/Measurement
Automation
Delivery
Delivery in 3-5 days for small qty. Otherwise 4-6 weeks
Specification
Oztherm Part Number
F923-X-XX-AC-XX
Functions
Single Phase AC Current Transducer
Supply Voltage
9-36VDC
Nominal Measurement Range
0-8 Amp (Sensor dependant)
Maximum Measurement Range
8 Amp
Alarm
C/O Relay 4Amp @ 30VDC, 0.5Amp @ 150VAC
Response Time
250mS
Accuracy @ 25 Deg C
Class 1
Bandwidth
DC - 1kHz
linearity
< 0.15%
Isolation
2.5kV
Comms
N/A
Weight
250g
Enclosure Size
79 x 60 x 85mm
Factory Pack Qty
1
EU Directives
N/A
Safety
Protection Class II
600V rms, installation category II
300V rms, installation category III
Pollution Degree 2 in compliance with SIST EN 61010-1:2002
Enclosure Material
Polyamide non combustable-self-extinguishability, complying with UL 94 V-0
Enclosure Protection
IP40
Shock Withstand
300g 8ms Pulse . 6 Shocks in each of 3 axes
Vibration Withstand
0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
SSR DC Control AC LoadFastron FDH2548ZA4, Solid State Relay, 70-480VAC, 25 Amp, 90-280VAC Control, Zero Crossing, Panel Mount, w/plastic Cover
Ratings from 25A to 125 Amp @ 48-480VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
CE Compliant to EN60950-1
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Specification
Fastron Part Number
FDH2548ZA4
Switching Type
Zero Crossing
CE
Yes
Control Voltage
90-280VAC
Load Current
25Amp (rms)
Surge Capability
195 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
Panel Mount
Load Voltage Range
70-480VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
250g
Factory Pack Qty
20
Datasheet
Product Datasheet
Fastron FTH2553ZA4, Solid State Relay, 3 Phase 90-280VAC Control, 25A, 70-530VAC Load, with IP20 Cover
Ratings from 25 to 120 Amp @ 70-480 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
IP20 Cover Included
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Includes IP20 Cover
Specification
Fastron Part Number
FTH2553ZA4
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
90-280VAC
Load Current
25 Amp (rms) per Phase
Surge Capability
350 Amp (peak)
Special Feature
LED Status Indicator, with IP20 Cover
Mounting Style
Panel Mount
Load Voltage Range
70-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
315g
Factory Pack Qty
10
Datasheet
Product Datasheet
Equivalent Parts
Contact Us for Possible Replacement
RCS-4800-XXXX Three-Phase Flexible Current Sensor System (Rogowski Coils):
Contact Us for Possible Replacement for specific Ratings
The RCS-4800 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 0.333 volt.
A 9 to 36 VDC power supply is required to operate these coils. The RCS-4800 comes with an integrator which includes flexible strain relief cables.
Included is an 12 inch circumference rope CT with Integrator, and 8 feet of twisted pair (600V) output leads.
Magnelab Coils come with 10 year warranty
Specification
Magnelab Part Number
RCS-4800-XXXX
Function
AC Current Measurement
Nominal Measurement Current (Ipn)
500-5000 Amp RMS (please specify with order)
Measurement Range
10% - 130% if Ipn
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
9 - 36VDC
Accuracy
1% from 25 to 5000 Amp
Phase Angle
< 0.5 Degrees
Coil Diameter (⌀)
12 Inch
Coil Circumference
36 Inch
Integrator to Coil Cable
8 Feet Shielded
Maximum Voltage
600V (on bare conductor)
Operating Temperature
-15°C to 65°C
Storage Temperature
-45°C to 80°C
Power Consumption
< 2VA
Overload
20,000 Amp (continuous)
Termination Style
Screw
Weight
1200g
Certification
CE
Factory Pack Qty
1
Certifications
UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1
Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010
CE
ROHS
Datasheet
Product Datasheet
Application Notes
RCS/RCT Series Installation Guide