Vishay Estamat MH-12N Automatic Reactive Power Controller 12 Step, 3 Phase
Isolated Switching of Power Factor Correction Contactors
Cos ϕ Setting 0.85 to 0.95 CAP
Auto CT Secondary Selection
Programmable Primary CT Ratio
Luminous Display
Various Program Combinations
IP40
Up to 12 steps
Measurement System - Automatic/Manual
230VAC Aux Supply
Overvoltage and Under/Overcompensation Alarm
Specification
Vishay Part Number
Estamat MH-12N
Function
Reactive Power Correction
Nominal Voltage (Un)
415V Line to Line (4 Wire)
Supply Voltage
230VAC (L-N), 12VA 45-65Hz
Relay Rating
250VAC/3Amp
Switch Delay Time
1s - 1200s User Adjustable
Alarm
1 x Relay as above
Temperature Alarm
N/A
Re-connection Delay Time
1s - 1200s User Adjustable
Desired Power Factor
0.85 IND - 1.00 CAP
Number of Output Relays
13
Smallest Capacitor Current
50mA
CT Input Range
0.05 - 5.5 Amp
LCD Display Accuracy
Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1
Phase Angle Error
+/- 1% at I > 3% of range
Comms
N/A
Termination Style
Screw
Weight
700g
Certification
IEC 654-1
Factory Pack Qty
1
Material of housing
PC/ABS Unflammable, according to UL 94 V-0
Enclosure protection
IP40 for case, IP20 for terminals
Safety
According to EN 61 010-1, installation category III Pollution degree 2
Operating Temperature
-20...60 °C
Datasheet
Product Datasheet
User Manual
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
Magnelab DVT-1000-420, DC Voltage Transducer, Din Rail Mount, 10-1000VDC, 4-20mA output, 15-48VDC Supply Voltage, 10mS Response
10mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Magnelab Part Number
DVT-1000-420
Control Output
4-20mA
Input
10 - 1000VDC
Measurement Range
120%
Overload
150% Continuous
Operating Temperature
-30 - 70°C
Operating Voltage
15 - 48VDC
Voltage Isolation (1 min)
4.5kV
Accuracy
1%
Response Time
10mS
Termination Style
Screw
Mounting Style
DIN Rail Mount
Safety
UL508C, CSA C22.2
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Rishabh CT 200/5 Class 0.5 2.5VA 50/21 (30) Series Current Transformer
Features
DIN Rail Mounting Clip Included
Built In Sealable Terminal Covers
Mounting Feet Supplied
Narrow Width (45mm)
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Safely Monitor Current with a 200/5
Safety should always be of paramount importance when designing and installing electrical systems. An appropriate current transformer, such as one rated at 200/5, may be an essential purchase when you need to easily transform a current from a very high voltage to a lower one as needed. In some cases, current transformers may connect with monitoring sensors to provide a safer operational posture and a clear idea of how a given electrical system performs. At Fastron, we've simplified the often complex buying process for items such as these, and we've created an online storefront that keeps you from rummaging through endless numbers of bins at the local electronics shop. Consider what you can accomplish with this product and the features of the 200/5 transformers we supply.
Fast Facts About Our 200/5 Options
With so many options on the market, it is important to know you're about to purchase the right product for the task you have in mind. What should you know about this particular current transformer? A few quick facts to consider:
Each unit is relatively low cost considering its function, yet built to meet exacting standards. Each unit features a design allowing it to support a primary current of 200 amps with a secondary current of 5 amps.
Be mindful of each component's minimum and maximum operational temperatures. According to the manufacturer datasheet, the 200/5 current transformer has a minimum rated temperature of -30C and a maximum of 85C.
Our units are compatible with standard DIN rail technology and include a mounting clip to make the installation process quick and simple. Quickly and accurately feed current information to an ammeter with this unit.
What Sets Fastron Apart Regarding a 200/5?
When you're certain you've found the appropriate product, why should you commit to purchasing from Fastron? As an experienced distributor of electronics components, we're well-positioned to provide a more valuable service. Here's how.
We've worked hard to identify the most reliable suppliers capable of meeting the exacting standards necessary for safe operations in electrical contexts.
We have additional equipment available to support diverse goals in the fields of energy monitoring and the control of alternating current power systems. Whether you have unique needs in the oil/gas industry or specific industrial and electrical applications, Fastron can supply your needs.
We don't leave customers in the dark on their order status. Instead, we provide quick shipping and prompt communication at every step of the transaction for an ideal procurement experience.
About Fastron
Backed up by more than four decades of experience in a wide range of electronics, and supporting a broad range of industries, is an independent supplier based in Melbourne. Constantly striving to source the best components while supporting long-term sustainability goals, Fastron is a cost-effective provider of not only 200/5 transformers, but many other energy monitoring and management products as well. (Learn more) about our business today, or Contact Us for Possible Replacement with questions or for product selection assistance.
Specification
Rishabh Part Number
CT 200/5 Class 0.5 2.5VA 50/21 (30)
Technology
AC Current Transformer
Ratio
200/5
Aperture Size
⌀ 21mm or 20x10mm Busbar
VA Rating
2.5VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
200Amp x 1.2
Termination Style
Screw
Unit Weight
300g
Factory Pack Qty
9
Datasheet
Product Datasheet
Iskra Doo RI61J C 6-10kA, 1 Pole DC Miniature Circuit Breaker Disconnect Switch C Curve 6 Amp, 220VDC, 4.5kA
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
< 50mS Trip Delay Time
1 Pole Disconnect
4.5kA Short Circuit Rating
Suitable for Isolation
Customised versions available
Type B, C, D Curve available
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Iskra Doo Part Number
RI61J C6
Functions
1 Pole MCB - C Curve
Nominal Voltage
220VDC
Nominal Current Range
6 Amp RMS
Trip Delay Time
< 50ms
Rated Frequency
50/60 Hz
Operating Temperature
-25 to 55 Deg C
Rated Operations
10,000 Ops
Surge Current
220V
Short Circuit Current
4.5kA
Approvals
VDE, GOST-R
Standards
IEC/EN 60898,60947-1/2, IP20 (IP40 Installed) IEC 61008 ;
Weight
130g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Iskra Doo RI61J C 16-10kA, 1 Pole DC Miniature Circuit Breaker Disconnect Switch C Curve 16 Amp, 220VDC, 10kA
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
< 50mS Trip Delay Time
1 Pole Disconnect
10kA Short Circuit Rating
Suitable for Isolation
Customised versions available
Type B, C, D Curve available
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Iskra Doo Part Number
RI61J C16
Functions
1 Pole MCB - C Curve
Nominal Voltage
220VDC
Nominal Current Range
16 Amp RMS
Trip Delay Time
< 50ms
Rated Frequency
50/60 Hz
Operating Temperature
-25 to 55 Deg C
Rated Operations
10,000 Ops
Surge Current
220V
Short Circuit Current
10kA
Approvals
VDE, GOST-R
Standards
IEC/EN 60898,60947-1/2, IP20 (IP40 Installed) IEC 61008 ;
Weight
130g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet