Rishabh Rish Con-V(500)-F-H-O1A1-O200-D-Z-Z, AC Voltage Transducer, Input Programmable True RMS 50Hz 57-500VAC Full Scale, 0-20mA, 60-300VAC Supply, with Display
Digital output setting 0-20mA/4-20mA/0-10V
Dual output version available
300mS response time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 43.75 x 100.9 mm depth DIN Rail cabinet space
Specification
Rishabh Part Number
Rish Con-V(500)-F-H-O1A1-O200-D-Z-Z
Measurement Output
4-20mA/0-20mA/0-10V User Selectable
Input
57 - 500VAC 50/60Hz
Overlaod (Continuous)
120%
Overload (1 second)
150%
Operating Temperature
-40 - 70°C
Supply Voltage
60 - 300VAC
Accuracy
0.2%
Response Time
300mS
Termination Style
Screw
Mounting Style
DIN Rail Mount
Safety
IP40/IP20 EN60529 Protection Class II EN61010
Weight
400g
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Technical Support
Rish Con P setup procedure blog
Â
Crouzet 87622162, Totalizer/Counter with orange Backlit Display CTR24 10-264VAC/DC, Lithium Battery Powered 8 year battery Life
Hour Meter with two PNP Inputs
IP65
4-30VDC PNP Inputs
6 Digit Display (8mm)
10-264VAC/DC Aux Supply
48 x 24mm Cutout
Rest On Panel or External Inhibit
Datasheet
Product Datasheet
GIC Controls, LA25F1 90-264VAC, Hours Run Meter 90-264VAC, 48x48mm Panel Mount
Â
Features
IP40 (IP66 with Gasket)
90-264VAC
6 Digit Display
99999.9 Hours
48x48mm Panel Mount
Rectangular Cutout
UL Approved
Datasheet
Product Datasheet
LEM ART-B22-D125-SP3 + AI-P1A, Single Phase Rogowski Coil Set, Class 1, 1 Amp AC, Sensitivity, and Measurement Range, 12.5cm Diameter
The universal Rogowski coil integrator AI-P1A complements LEM’s flexible clip-around coil ART and ARU range. The design is based on digital processing to give combined dynamic range, accuracy and versatility of use. It offers a wide range of output signals both RMS and instantaneous. AI-P1A is DIN rail mounted and can be stacked for multiphase application without spacing thanks to its low power dissipation.
Input signal
Accuracy Class 0.5 (IEC 61869-2) [1].
Linearity error ≤ 0.10 %. Protection degree IP2X.
35 mm DIN rail mounted.
Push-in terminals.
1 Amp instantaneous output.
6 selectable sensitivities depending on Rogowski coil: 22.5, 70, 80, 85, 100, 120 mV/kA at 50 Hz.
12 selectable ranges: 100, 200, 300, 400, 500, 600, 800, 1000, 1500, 2000, 4000, 5000 A.
Ambient operating temperature −25...+70 °C.
Advantages
Compact design for DIN rail assembly
High accuracy Class 0.5 (IEC 61869-2)
Setup by user via Select / Edit buttons
Clear status indication via bi-color led
Applications
MV/LV substations on LV side: Transformer Condition Monitoring
Power metering: current measurement for active power calculation
Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation
Power quality monitoring: electrical loads and distribution system equipment
Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault
Remote Terminal Units (RTU)
Phasor Measurement Units (PMU)
Standards
IEC 61010-1: 2010
UL
EMC: IEC 61326-1:2012
Options
Cross Power Plug-in: side contacts to stack up to 3 Integrator modules and use only one power supply.
Specification
LEM Part Number
ART-B22-D125-SP3 + AI-P1A
Function
Single Phase AC Current Measurement
Measuring Range
Selectable 5000,4000,2000,1500,1000,800,600,500,400,300,200,100Amp
Sensitivity
Selectable 22.5,70,80,85,100,120mV/kA @ 50 Hz
Output
1 Amp output
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
10-32VDC
Accuracy
1% from 25 to 5000 Amp
Current Consumption
100mA (max)
Dimensions
100mm x 78mm x 15mm (Integrator), 7cm Diameter (Coils)
Mounting
Din Rail Mount
Integrator to Coil cable
3M Twisted and Screened
Integrator to Meter cable
User Supplied Shielded cable 1.5mm sqr, up to 6m long
Operating Temperature
-25°C - 70°C
Storage Temperature
-45°C to 80°C
Isolation (50Hz, 1 min)
1.5kV
True RMS Response Time
160-190ms
Termination Style
Push-in for 1.5mm sqr wire
Weight
58g
Factory Pack Qty
1
Certifications
Â
UL, ROHS
Datasheet
AI-P1A Datasheet
ART Series Datasheet
Application Notes
User Notice
1) The Rogowski coil can measure any primary current as there is no saturation effect.
2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts)
3) Frequency bandwidth and phase shift modelling schematic can be provided on request.
4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer)
5) Considering a primary conductor of at least ⌀ 15 mm, perpendicular and in contact with the Rogowski coil.
6) Considering an external conductor of at least ⌀ 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.
Â
LEM ART-B22-D125-SP3 + AI-P1A - 3 Pcs, 3 Phase Rogowski Coil Set, Class 1, 1 Amp AC, Sensitivity, and Measurement Range, 12.5cm Diameter, 3M integrator Cable
The universal Rogowski coil integrator AI-P1A complements LEM’s flexible clip-around coil ART and ARU range. The design is based on digital processing to give combined dynamic range, accuracy and versatility of use. It offers a wide range of output signals both RMS and instantaneous. AI-P1A is DIN rail mounted and can be stacked for multiphase application without spacing thanks to its low power dissipation.
Input signal
Accuracy Class 1 (IEC 61869-2) [1].
Linearity error ≤ 0.10 %. Protection degree IP2X.
35 mm DIN rail mounted.
Push-in terminals.
1 Amp instantaneous output.
6 selectable sensitivities depending on Rogowski coil: 22.5, 70, 80, 85, 100, 120 mV/kA at 50 Hz.
12 selectable ranges: 100, 200, 300, 400, 500, 600, 800, 1000, 1500, 2000, 4000, 5000 A.
Ambient operating temperature −25...+70 °C.
Advantages
Compact design for DIN rail assembly
High accuracy Class 1 (IEC 61869-2)
Setup by user via Select / Edit buttons
Clear status indication via bi-color led
Applications
MV/LV substations on LV side: Transformer Condition Monitoring
Power metering: current measurement for active power calculation
Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation
Power quality monitoring: electrical loads and distribution system equipment
Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault
Remote Terminal Units (RTU)
Phasor Measurement Units (PMU)
Standards
IEC 61010-1: 2010
UL
EMC: IEC 61326-1:2012
Options
Cross Power Plug-in: side contacts to stack up to 3 Integrator modules and use only one power supply.
Specification
LEM Part Number
ART-B22-D125-SP3 + AI-P1A - 3 Pcs
Function
3 Phase AC Current Measurement
Measuring Range
Selectable 5000,4000,2000,1500,1000,800,600,500,400,300,200,100Amp
Sensitivity
Selectable 22.5,70,80,85,100,120mV/kA @ 50 Hz
Output
1 Amp Instantaneous
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
10-32VDC
Accuracy
1% from 25 to 5000 Amp
Current Consumption
100mA (max)
Dimensions
100mm x 78mm x 15mm (Integrator), 12.5cm Diameter (Coils)
Mounting
Din Rail Mount
Integrator to Coil cable
3M Twisted and Screened
Integrator to Meter cable
User Supplied Shielded cable 1.5mm sqr, up to 6m long
Operating Temperature
-25°C - 70°C
Storage Temperature
-45°C to 80°C
Isolation (50Hz, 1 min)
1.5kV
True RMS Response Time
160-190ms
Termination Style
Push-in for 1.5mm sqr wire
Weight
1125g
Factory Pack Qty
1
Certifications
Â
UL, ROHS
Datasheet
AI-P1A Datasheet
ART Series Datasheet
Application Notes
User Notice
1) The Rogowski coil can measure any primary current as there is no saturation effect.
2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts)
3) Frequency bandwidth and phase shift modelling schematic can be provided on request.
4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer)
5) Considering a primary conductor of at least ⌀ 15 mm, perpendicular and in contact with the Rogowski coil.
6) Considering an external conductor of at least ⌀ 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.
Â
VA Instruments VA90A, Touch Pad Multimeter For Average RMS, 0-1000V AC/DC, Linear Frequency, AC/DC uA/mA/10A, -200 to 1000 Deg C, 0- 60 MOhm, 0-60mF, Diode Test, Continuity Test
Â
For Testing of:
Touch Pad Multimeter For True RMS
AC/DC Voltage 0-1000V
Linear Frequency
AC/DC uA/mA/10A
Temperature -200 to 1000 Deg C
Resistance 0- 60 MOhm
Capacitance 0-60mF
Diode Test
Continuity Test
TTL Frequency/Duty
Auto Range
True RMS Measurement
Display Counts 6000, IP67
AUTO Back Light
USB Chargeable
Li Batteries
190 x 190 x 40mm
USB Comms & Free App
IP67
Specification
Â
Datasheet
Datasheet
Â
Secure Meters DPM96I310-2, 96mm x 96mm RED LED Digital AC Ammeter, 3 Phase 0-6 Amp CT Inputs, 0.5% Accuracy, 40 to 300VAC/DC Supply, IP54 (Optional IP65)
Â
Features
LCD Dual Display
250mS Response Time
PC 94 UL V0
Each unit needs just 96 x 96mm Panel Space
52mm Depth
CE Approved
ROHS and REACH
Specification
Secure Part Number
DPM96I360-2
Frequency Range
45-65 Hz
Accuracy
0.5%
Input
0-6 Amp 3 Phase CT inputs
Over Range
x 1.5
Operating Temperature
0 - 60°C
Supply Voltage
40-300VAC/DC
Termination Style
Screw
Mounting Style
96 x 96mm Panel Mount
Case Material
PC - UL 94 V0
Standards
IEC / EN 61010-1; IEC / EN 61010-2-030
Protection Degree
IP54 (IP65 Optional)
Weight
450g
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Manual
DPM Series User Manual
Application Notes
Panel Meters Blog Articles
BS1-ND102, Digital DC Voltmeter, 48x24mm, 85-265VAC, Range : 0-1.99VDC
3.5-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
UL/CE Approved
Each unit needs just 100.2 mm depth panel space
EC Compliant
Specification
Hanyoung Nux Part Number
BS1-ND102
Input
0-1.99VDC
Mounting Style
48 x 24mm Panel Mount
Supply Voltage
85Â - 265VAC
Termination Style
Screw
Weight
250g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Â
Datasheet
BS1 Series Instruction Manual
BS1 Series Wiring and Selection Tables
Free Software
Hanyoung Nux TCS Software
Hanyoung Nux TCS Software User Manual
VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
Secure Meters DPM48F150-2, 48mm x 96mm LCD Digital Frequency Meter, 57.5-250VAC Input 45-65 Hz, 0.5% Accuracy, 40 to 300VAC/DC Supply, IP54 (IP65 Optional)
Â
Features
LCD Dual Display
250mS Response Time
PC 94 UL V0
Each unit needs just 96 x 48mm Panel Space
52mm Depth
CE Approved
ROHS and REACH
Specification
Cewe Part Number
DPM48F150-2
Frequency Range
45-65 Hz
Accuracy
0.1Hz
Input
57.5-250VAC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Supply Voltage
40 to 300VAC/DC
Termination Style
Screw
Mounting Style
96 x 48mm Panel Mount
Case Material
PC - UL 94 V0
Standards
IEC / EN 61010-1; IEC / EN 61010-2-030
Protection Degree
IP54 (IP65 Optional)
Weight
280g
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Manual
DPM Series User Manual
Application Notes
Panel Meters Blog Articles
VA Instruments VA30, High Accuracy Multimeter, Average RMS 200uA-220mA +/-1.5%, Voltage 200mV - 1000V AC/DC (+/-0.8/0.2%), 200-220M Ohm, 22nF-220mF, 2Hz - 200kHz/10MHz, 5%-94.9% Duty, -50 to 1000 Deg C, USB/ Infra Red Interface, Free software, Carry Case
Â
For Testing of:
High Accuracy Multimeter For TRUE RMS
Current AC(200uA - 220mA +/-1.5%) DC(220uA - 220mA +/-0.8%,
Voltage AC(200mV - 1000V +/-0.8%) DC(200mV to 1000V +/-0.2%)
Resistance (200 Ohm -220MOhm),
Capacitance (22nF-220mF +/-5.0%)
Logic Frequency (2Hz - 10MHz +/-0.05%)
Linear Frequency 2Hz - 200Khz +/-0.05% , Duty Cycle 5% - 94.9% +/-2.0% Temperature -50 to 1000 Deg C
6 x AAA Batteries. 200 x 100 x 40mm,
USB & Infra red Interface
Free Software,
Display Counts = 50,000
WITHOUT PEAK HOLD FUNCTION
Specification
Â
Datasheet
Datasheet
Â
VA Instruments VA30, High Accuracy Multimeter, Average RMS 200uA-220mA +/-1.5%, Voltage 200mV - 1000V AC/DC (+/-0.8/0.2%), 200-220M Ohm, 22nF-220mF, 2Hz - 200kHz/10MHz, 5%-94.9% Duty, -50 to 1000 Deg C, USB/ Infra Red Interface, Free software, Carry Case
Â
For Testing of:
High Accuracy Multimeter For TRUE RMS
Current AC(200uA - 220mA +/-1.5%) DC(220uA - 220mA +/-0.8%
Voltage AC(200mV - 1000V +/-0.8%) DC(200mV to 1000V +/-0.2%)
Resistance (200 Ohm -220MOhm)
Capacitance (22nF-220mF +/-5.0%)
Logic Frequency (2Hz - 10MHz +/-0.05%)
Linear Frequency 2Hz - 200Khz +/-0.05% , Duty Cycle 5% - 94.9% +/-2.0% Temperature -50 to 1000 Deg C
6 x AAA Batteries. 200 x 100 x 40mm
USB & Infra red Interface
Free Software
Display Count 22000
Specification
Â
Datasheet
Datasheet
Â