Search results for "텔레@tetherzon^~trc20전송대행코인원FDS출금지연"
-
TSFFNCR-80, 80 Deg C, NC Thermal Switch 10 Deg C Hysteresis, +/-2% Tolerance, Fixed Flange Mount, with 90 Deg Raised Terminals
80 Deg C Normally Closed Thermal Switch 10 Deg C Hysteresis, +/-2% Tolerance, Fixed Flange Mount, with 90 Deg Raised Terminals, KSD301, R20 Datasheet Product Datasheet
$8.50
$10.03 inclGST -
TSFFNCR-90, 90 Deg C, NC Thermal Switch 10 Deg C Hysteresis, +/-2% Tolerance, Fixed Flange Mount, with 90 Deg Raised Terminals
90 Deg C Normally Closed Thermal Switch 10 Deg C Hysteresis, +/-2% Tolerance, Fixed Flange Mount, with 90 Deg Raised Terminals, KSD301, R20 Datasheet Product Datasheet
$8.50
$10.03 inclGST -
TSFFNCR-110, 110 Deg C, NC Thermal Switch 10 Deg C Hysteresis, +/-2% Tolerance, Fixed Flange Mount, with 90 Deg Raised Terminals
110 Deg C Normally Closed, Thermal Switch 10 Deg C Hysteresis, +/-2% Tolerance, Fixed Flange Mount, with 90 Deg Raised Terminals, KSD301, R20 Datasheet Product Datasheet
$8.50
$10.03 inclGST -
M-FRS3-C40-500R-T2, MODULE ONLY 500VDC Module for Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA
M-FRS3-C40-500R-T2, MODULE ONLY 500VDC Module for Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA Specifications Trent part number M-FRS3-C40-500R-T2 MODULE ONLY Nominal Voltage 500VDC No of Poles N/A Category IEC / EN / VDE Type 2 (Class II) Location of use String Box, Inverter, Sub Board Only Protection modes (+)-PE,(-)-PE,(+)-(-) PE Additional Remote Contacts YES NO/NC/COM Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Weight 420g Standards IEC614643-31:2018 (TUV, CE Approved) Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$15.00
$17.70 inclGST -
M-FRS3-C40-1000R-T2, MODULE ONLY 1000VDC Module for Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA
M-FRS3-C40-1000R-T2, MODULE ONLY 1000VDC Module for Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA Specifications Trent part number M-RS3-C40-1000R-T2 MODULE ONLY Nominal Voltage Un 1000VDC No of Poles N/A Category IEC / EN / VDE Type 2 (Class II) Location of use String Box, Inverter, Sub Board Only Protection modes (+)-PE,(-)-PE,(+)-(-) PE Additional Remote Contacts YES NO/NC/COM Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Weight 420g Standards IEC614643-31:2018 (TUV, CE Approved) Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$15.50
$18.29 inclGST -
M-FRS3-C40-1500R-T2, MODULE ONLY 1500VDC Module for Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA
M-FRS3-C40-1500R-T2, MODULE ONLY 1500VDC Module for Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA Specifications Trent part number M-FRS3-C40-1500R-T2 MODULE ONLY Nominal Voltage Un 1500VDC No of Poles N/A Category IEC / EN / VDE Type 2 (Class II) Location of use String Box, Inverter, Sub Board Only Protection modes (+)-PE,(-)-PE,(+)-(-) PE Additional Remote Contacts YES NO/NC/COM Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Weight 420g Standards IEC614643-31:2018 (TUV, CE Approved) Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$16.00
$18.88 inclGST -
F921 DC Series Current Transducer, 100mA to 400 Amp Range with Adjustable High and Low C/O Relay Alarm
F921 DC Series Current Transducer 100mA to 400 Amp Range with Adjustable High and Low C/O Relay Alarm Features Isolated measurement of DC currents using a Hall effect transducer with external aperture. Incorporates an integrated input level display and power supply. Wide measurement range available Choice of standard outputs Wide range isolated DC input supply DIN Rail mounting Signal Conditioned DC measurement output On board bar graph display User adjustable zero offset and span controls Zero insertion loss in current measurement path Earth leakage via differential Ipn for nominal Input ‘01’ Applications Process control Transportation Petrochemical Industrial Earth Leakage Energy Monitoring/Measurement Automation Delivery Delivery in 3-5 days for small qty. Otherwise 4-6 weeks Specification Oztherm Part Number F921-X-XX-DC-XX-XX Functions Single Phase AC Current Transducer Supply Voltage 9-36VDC Nominal Measurement Range 0-400 Amp (Sensor dependant) Maximum Measurement Range 2500 Amp with External Sensor Alarm C/O Relay 4Amp @ 30VDC, 0.5Amp @ 150VAC Response Time 250mS Accuracy @ 25 Deg C Class 1 Bandwidth DC - 1kHz linearity < 0.15% Isolation 2.5kV Comms N/A Weight 250g Enclosure Size 79 x 60 x 85mm Factory Pack Qty 1 EU Directives N/A Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material Polyamide non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP40 Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet
$595.00
$702.10 inclGST -
FRTD-Transmitter-0-100-420-24, Pt100, 4-20mA Transmitter, 0 to 100 Deg C, 24VDC Supply
Fastron FRTD-Transmitter-0-100-420-24, Pt100, 4-20mA Transmitter, 0 to 100 Deg C, 24VDC Supply Class A Accuracy Steel Insulated Cable Low Long Term Drift Rated for 0 to 220 Deg C Max Spring Cable Connection 60mm Jaw Clip Specification Fastron Part Number FRTD-Transmitter-0-100-420-24 Sensor Type Pt100 to 4-20mA Transmitter No of Wires 3 Shaft Length N/A Shaft Thickness N/A Accuracy Class B Temperature Range 0 to 400 Deg C Span/ Zero Adjustment YES Weight 50g Factory Pack Qty 1
$25.00
$29.50 inclGST -
MYG20-431, Varistor, 275VAC, 350VDC, K20 Axial Package 105W
Trent MYG20-431 Series Metal Oxide Varistor (MOV), 275VAC, 350VDC, K20 Axial Package 105W, Replaces V275K20 High Energy Absorption Rating Industry Standard Package Wide Operating Range 35 - 1100VAC High Peak Current Capability (70kA) UL/CSA/ROHS/ISO9001:2015 Approved Panel Mount Screw Terminals APPLICATION AREAS: 1. Railways and trams: For the protection of electrical equipment, power electronics (IGBT, thyristors...) in systems with alternating, direct or combined AC + DC power supply, especially in power supply of AC/DC, DC/AC, DC/DC converters. They may be used in systems with main and auxiliary power supply for example: automatic control and regulation systems, cooling systems, warming systems, ventilation systems, and combination systems (electromechanical, electropneumatic and other systems). 2. Wind powerplants For protection of automatic control and regulation in power electronics (IGTB, tyristors...), as well as the protection of sensitive electronic systems (e. g. AC/DC, DC/AC, DC/DC converters, drive systems) from direct or indirect lightning strikes. 3. Photovoltaic systems For protection of photopanels, automatic control electronics with sensitive electronic components, and DC/AC converters (inverters) from direct or indirect lightning strikes. Depending on the application, both serial and parallel connections are possible. With serial connection the required voltage is achieved. With parallel connection higher current absorption is achieved in the modules. Specification Trent Part Number MYG20-431 Operating Voltage AC (50-60Hz) 275V Operating Voltage DC 430V Average Power Dissipation 1W Permissable Peak Current 10kA Energy Absorption(2ms) 167W(max) Tolerance(Vn) +/- 10% Termination Style Ring Lug Weight 3g Factory Pack Qty 1 ROHS Yes UL Yes CSA Yes Datasheet Product Datasheet Application Notes Technical Blog MOV Article
$1.10
$1.30 inclGST -
DTC1-A/M-TR, DIN Rail Mount Process Transmitter with Alarm Function, Multirange TC/RTD/4-20mA, 85-265VAC, 4-20mA output
Fastron DTC1-A/M-TR, DIN Rail Mount Process Transmitter with Alarm Function, Multirange TC/RTD/4-20mA, 85-265VAC, 4-20mA output Filter Time Constant Function Converter function 2 Input 1 Output, and 1 Input Two Output Versions available 4-digit display. Suit most industries including Temperature, Humidity, Pressure (0.5s response) CE Approved Each unit needs just 22.5mm width Din Rail space EC Compliant (Details) Various specials available for unique applications. Specification Fastron Part Number DTC1-A/M-TR Transmitter Output 4-20mA Input Multirange RTD/K/J/R/S/B/E/T/4-20mA/N/W1/W2 Alarm Relay 3A(Resistive), 1A(Inductive load cos ??=0.4), 240VAC/30VDC Options None Mounting Style 22.5 x 75mm Din Rail Mount Supply Voltage 85 - 265VAC Termination Style Screw Weight 230g Factory Pack Qty 1 CE Yes ?? Selection Chart Datasheet DTC1 Brochure DTC1User Manual DTC1 User Manual Comms versions Alarm Table DTC1 (Program Control Version) User Manual
$209.00
$246.62 inclGST -
DTC1-A/M-2O, DIN Rail Mount Dual Transmitter Multirange Input, 85-265VAC, Dual 4-20mA Outputs
Free Aus Post Shipping for $300 spendFastron DTC1-A/M-2O, DIN Rail Mount Dual Transmitter Multirange Input, 85-265VAC, Dual 4-20mA Outputs Optional converter function 2 Input 1 Output, and 1 Input Two Output Versions available Optional 60 Segment Multi Pattern Program Control feature 4-digit display. Suit most industries including Temperature, Humidity, Pressure (0.5s response) CE Approved Each unit needs just 22.5mm width Din Rail space EC Compliant (Details) Various specials available for unique applications. Specification Fastron Part Number DTC1-A/M-2O Control Output 2 x 4-20mA outputs Input Multirange K/J/R/S/B/E/T/Linear Voltage Current(Optional)/N/W1/W2/Pt100 Alarm Relay 3A(Resistive), 1A(Inductive load cos ??=0.4), 240VAC/30VDC Options Dual Output Mounting Style 22.5 x 75mm Din Rail Mount Supply Voltage 85 - 265VAC Termination Style Screw Weight 230g Factory Pack Qty 1 CE Yes ?? Selection Chart PWM Control Wiring Datasheet DTC1 Brochure DTC1User Manual DTC1 User Manual Comms versions Alarm Table DTC1 (Program Control Version) User Manual
-
DTC1-A/M-C5, DIN Rail Mount Temperature/Humidity Controller, Multirange Input, 85-265VAC, 4-20mA output
Free Aus Post Shipping for $300 spendFastron DTC1-A/M-C5, DIN Rail Mount Temperature/Humidity Controller, Multirange Input, 85-265VAC, 4-20mA output Optional converter function 2 Input 1 Output, and 1 Input Two Output Versions available Optional 60 Segment Multi Pattern Program Control feature 4-digit display. Suit most industries including Temperature, Humidity, Pressure (0.5s response) CE Approved Each unit needs just 22.5mm width Din Rail space EC Compliant (Details) Various specials available for unique applications. Specification Fastron Part Number DTC1-A/M-C5 Control Output 4-20mA Input Multirange K/J/R/S/B/E/T/Linear Voltage Current(Optional)/N/W1/W2/Pt100 Alarm Relay 3A(Resistive), 1A(Inductive load cos ??=0.4), 240VAC/30VDC Options RS485 Comms Mounting Style 22.5 x 75mm Din Rail Mount Supply Voltage 85 - 265VAC Termination Style Screw Weight 230g Factory Pack Qty 1 CE Yes ?? Selection Chart PWM Control Wiring Datasheet DTC1 Brochure DTC1User Manual DTC1 User Manual Comms versions Alarm Table DTC1 (Program Control Version) User Manual