FP250160P, 2500/5 Amp Split Core CT, Class 0.5 15VA Series Clip On Current Transformer
Features
Quick Release Split Core System
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Electronics Part Number
FP250160P
Technology
Split Core AC Clip On Current Transformer
Ratio
2500/5
Aperture Size
80 x 160mm
VA Rating
15VA
Accuracy Class
Class 0.5
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
2500Amp x 1.2
Termination Style
Screw
Approvals
CE
Unit Weight
1150g
Factory Pack Qty
1
Datasheet
Product Datasheet
Installation Guide
Fastron Electronics FAT200D420, AC Current Transducer, 200Amp Measurement, 24mm Split Core, 4-20mA Average RMS Output, Accuracy = 1%
Features
Quick Release 24mm Split Core System
Cale Mount
4-20mA Output
24VDc Aux
Rated System Voltage 0.60/2.5kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
FAT200D420
Technology
24mm Split Core AC Current Transformer
Ratio
200/4-20mA
Aperture Size
ø 24 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
4-20mA (+20%)
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
200Amp x 1.2
Termination Style
0.5M Flying leads
Unit Weight
300g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Fastron Electronics BTCR/R-M-A3-EI, PID Controller 48x96mm, 85-265VAC, Relay Output 2 Alarms, Event input (2xSV ), Multirange TC/RTD/4-20mA Input
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Dust-proof IP56 (front panel only)
Optional 32-step pattern (for SV and time) is a standard feature
CE Approved
Each unit needs just 80 mm depth panel space
Specification
Fastron Electronics Part Number
BTCR/R-M-A3-EI
Control Output
Relay 3 Amp (Resistive)
Input
Multirange TC/RTD/4-20mA (Optional Linear voltage/current other than 4-20mA. Refer to datasheet)
Option 1
2nd and 3rd Alarm
Option 2
Event Input (2 x SV)
Mounting Style
48 x 96mm Panel Mount
Load Voltage Range
100-240VAC
Termination Style
Screw
Weight
450g
Factory Pack Qty
1
Yes
UL
Yes
CE
Yes
Datasheet
BTC Series Brochure
BTC Series User Manual
BTC Series RS485 Comms Manual
Fine Tuning PID Adjustments
Current Transducer, AT-AAO(0-1)-A-1, AC Current Transducer, 1 Amp Average RMS, 100-240VAC/DC Aux, 4-20mA output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) or 0-10V/0-5V (For Direct Voltage Type)
Each unit needs just 50mm x 120mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
AT-AAO(0-1)-A-1
Control Output
4-20mA Average RMS
Input
0-1 Amp Rms
Over Range
x 1.2
Operating Temperature
0 - 60°C
Load Voltage
100-240VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
TPR-3SL040H, SCR Phase/Burst Controller FANLESS, 400VAC 3 Wire (400V L-L, 230V L-N), 3 Phase, 1-5V/4-20/0-20mA/10K POT Input, with In built Fuses, 32 Amps per Phase @ 50 Deg C
Features
Phase Angle, Distributed Burst, and Time Proportional Burst Control Functions
3 Phase, or Single Phase, Angle/Burst Controller
4-20mA/1-5V/10K POT Input Proportional Control
Fully enclosed IP20
Phase Angle or Burst switching
Aluminium/Plastic Frame
Removable Cover
Applications
Electrical Ovens, Kilns, or Furnaces
HVAC Heaters
Controlled Power Applications
Electric Boilers
Brewery Heating
Industrial Light Dimming
Suitable for HVAC or Industrial Environments
Specification
Fastron Part Number
TPR-3SL040H
Rated Operating Temperature
50°C
SCR Configuration
3 Phase AC Switch
Control Voltage
4-20mA (Default), 0-5V, 10K POT)
Load Current
32 Amps Per Phase @ 50 Deg C
Derating
2% per 1 Deg C (approx)
Control Range
0-100%
Alarms
2 x NO Relay Contact
Comms
Optional RS485 Modbus RTU
Special Feature
Internal Fuse
Mounting Style
Panel Mount
Switching Voltage Range
400VAC +/-10%
Supply Voltage
100-240VAC +/-10%
Delay on Start
NA
Soft Start
Programmable from 0 to 60 seconds
Termination Style
Screw
Unit Weight
4kg (6kg Packed)
Factory Pack Qty
1
Technical Docs
User Manual
LEM APR 50 B420L, Split Core AC Current Sensor, selectable 10, 25, 50 Amp, True RMS 4-20mA output, Infinite Overload Capability
Compact and versatile Split Core AC current sensor, selectable 10, 20, 50 Amp True RMS 4-20mA output
Features
Split Core
True RMS output
4-20mA current output
Busbar, or Din Rail
Isolated plastic case recognised according to UL94-V0
Advantages
Large aperture for busbar/cable up to 18.5mm x 18.5mm
High isolation between primary and secondary circuits
Easy installation
DIN Rail Mount
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
LEM Part Number
AP 50 B420L
Technology
AC Current Transformer with Process Output
ROHS
Yes
Supply Voltage
24VDC Powered
Nominal Current (RMS + DC)
10,20,50 Amp Selectable
Overload
Infinite
Output
4-20mA True RMS
Isolation
5kV (AC, 50Hz, 1 min)
Bandwidth
30-2000Hz
Mounting Style
Din Rail mount or Busbar mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Spring Terminal Block (Female Included)
Unit Weight
90g
Factory Pack Qty
6
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Fastron HS212DR-F & FCR-400-40R-5, Three Phase, Phase Angle Controller, 4-20mA,0-5V,500K POT Input, 400VAC, 20 Amp @ 40 Deg C, Din Rail Mount
4-20mA,0-10V, 0-5V or 500K POT Proportional Phase Control Input
Ratings from 25A to 120 Amp @ 180-280 VAC
SCR output for heavy industrial loads
Instantaneous turn-on output
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Specification
Trent part Number
HS212DR-F & FCR-400-40R-5
Switching Type
Phase Angle (Random Crossing)/ Burst Fire (10 cycles)
Control Voltage
4-20mA,0-5V,500K POT Proportional Input
Load Current
36 Amp (rms) per phase @ 40 Deg C
Surge Capability
690Amp (peak)
Special Feature
Three Phase Proportional Controller
Mounting Style
DIN Rail Mount
Load Voltage Range
350-400VAC +15% (460VAC Max)
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Barrier Strip Screw
Dimensions
100 x 135 x 130mm
Unit Weight
1500g
Factory Pack Qty
20
Datasheet
FCR Series Voltage Regulators
HS212 Datasheet
Fastron Electronics FAT100D420, AC Current Transducer, 100Amp Measurement, 24mm Split Core, 4-20mA Average RMS Output, Accuracy = 1%
Features
Quick Release 24mm Split Core System
Cale Mount
4-20mA Output
24VDc Aux
Rated System Voltage 0.60/2.5kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
FAT100D420
Technology
24mm Split Core AC Current Transformer
Ratio
100/4-20mA
Aperture Size
ø 24 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
4-20mA (+20%)
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
100Amp x 1.2
Termination Style
0.5M Flying leads
Unit Weight
300g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Fastron FCP-S-V-1-G-2, PID Pattern Controller, 48x48mm, 100-240VAC, SSR output, 1 Alarm, 8 steps (segments), 4 patterns (programs), Interlinkable
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
4 x 8-step patterns, is a standard feature
CE Approved
Each unit needs just 60 mm depth panel space
EC Compliant (Details)
Specification
Fastron Part Number
FCP-S-V-1-G-2
Control Output
12VDC SSR, 4 Program 8 steps, Interlinkable.
Input
Multirange (refer to datasheet)
Option 1
1 Alarm
Option 2
N/A
Mounting Style
48 x 48mm Panel Mount
Load Voltage Range
100-240VAC
Termination Style
Screw
Weight
250g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Datasheet
FC-P Datasheet
Trent FRS4-C40/480VAC (R),4 Pole, Uc = 480VAC L-L 960VAC, L-PE 1360VAC, Type 2 (Class II) Surge Protection Device In 20kA, Imax 40kA, Pluggable, With 4 x Remote Contacts
Specifications
Trent part number
FRS4-C40 3P+N 480VAC (R)
Nominal Voltage (Un)
480VAC
Maximum Operating Voltage (Uc)
L-L : 960 V AC ; L-PE : 880VAC
Voltage Protection Level (Up)
L-L: ≤ 3.8kV; L-PE: ≤ 5.1kV
No of Poles
3 + 0
Category IEC / EN / VDE
Class II / Type 2
Location of use
Sub Distribution Boards
Protection modes
L-L L-PE, High Energy MOV
Additional Remote Contacts
YES (4x)
Protective element
MOV
Surge discharge rating
Imax up to 40kA(8/20us) L-PE/L-L 320VAC / 20kA(8/20us) L-PE/L-L
Internal protection and safety
Thermal disconnector in each MOV
Standards
IEC/EN 61643-11
Datasheet
Product Datasheet
LEM PCM 10-P/SP1 Series Closed Loop Bipolar DC Hall Effect Sensor for Point System Monitoring, Bipolar 4-20mA Output
Features
Closed loop sensor using Hall Effect
Panel mounting
Split core design for easy installation
Insulated plastic case to UL 94-V0 Water resistant design rated to IP 67
Reverse polarity protected
2M flying leads
Advantages
Very good linearity
Excellent accuracy
Current overload capability
No insertion losses.
Non - contact measurement (does not need a safety case)
Applications
Railway equipment
Points condition monitoring
Signal light indication
Battery supplied applications Uninterruptable Power Supplies (UPS).
Specification
LEM Part Number
PCM 10-P/SP1
Technology
Closed Loop Hall Effect
ROHS
Yes
Supply Voltage
24V
Aperture
ø15.6mm
Load Current (RMS + DC)
10 Amp
Measuring Range
+/- 20 Amp
Overload Capacity (Ampere Turns)
30000 Amp
Output
4-20mA
Standards
EN 50121-59EMC),EN 50155(temperature and humidity),EN61010-1/2 (safety)
Bandwidth
DC-1000Hz
Mounting Style
Panel Mount
Operating Temperature Range
-25°C / 70°C (55°C Continuous)
Accuracy
0.5%
Termination Style
Switchcraft EN3L4M connector with 2M Flying Leads
Unit Weight
120g
Factory Pack Qty
4
Datasheet
Product Datasheet
Application Notes
FAQ
LEM FRS 3000-SUI, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output
Features
Bandwidth DC to 1000kHz
Open loop transducer using Coreless Hall effect Technology
Compact and versatile
Panel mounting-Horizontal or Vertical
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
Low power consumption
Applications
Wind Turbines
Electrolyser
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications.
Specification
LEM Part Number
FRS 3000-SUI
Technology
Open Loop Coreless Hall Effect
Aperture
111.4 x 18.7mm Square
ROHS
Yes
Supply Voltage
+12...24VDC, Isolated
Load Current (RMS + DC)
3000 Amp
Measurement Range
+/-9000 Amp
Overload Rating
N/A
Output
4-20mA Unipolar
Isolation
5.3 kV
Bandwidth
DC-1000 kHz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-25°C / 85°C
Accuracy
1%
Termination Style
Molex 5045-04A
Unit Weight
1500g
Factory Pack Quantity
4
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition