ESCT-TA24-300A/100mA + HY-2.0, 300A/100mA Measurement, Class 1 Split Core CT's
Free Aus Post Shipping for $300 SpendEastron Europe Electronics ESCT-TA24-300A/100mA + HY-2.0, 300A/100mA Measurement, Class 1 Split Core CT's Features Quick Release Split Core System Cable Mount 100mAmp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads with HY-2.0 Connector Applications Eastron Modular Metering Equipment Energy Monitoring Load Balancing Power Quality Measurements Specification Eastron Europe Part Number ESCT-TA24-300A/100mA + HY-2.0 Technology Split Core AC Current Transformer Ratio 300/100mA Aperture Size ø 24 mm VA Rating 1VA Accuracy Class Class 1 Output 100mA (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 300Amp x 1.2 Termination Style 0.9M Flying leads with HY-2.0 Connector Unit Weight 100g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide CRJ-31 Connector User Guide
-
TGLW26-1021250, 1 Pole Rotary Switch BLACK, 250 Amp 400VAC, Plastic, Direct Type, IEC60947-5-1
Free Aus Post Shipping for $300 SpendTGLW26-1021250, 1 Pole Rotary Switch BLACK, 250 Amp 400VAC, Plastic, Direct Type, IEC60947-5-1 Rotary Load Break or Disconnect Switches are used to Isolate or Switch under load. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation by the user. Features : 400VAC in various Ratings 1 Pole Momentary 64mm x 64mm Cutout Standards : IP40 IEC60947-5-1 CE Specification TRENT Part Number TGLW26-1021250 Functions 1 Pole AC Disconnect Nominal Voltage 400VAC @ 50/60Hz Rated Impulse Voltage 6kV Nominal Current Range AC 250Amp @400VAC Rated Insulation Voltage 690VAC Humidity 35-85% Approvals CE Standards IEC 60947-1,-3, IEC 60204, IP20 (IP40 Installed) Weight 1.64kg Enclosure Material UL94V0 Factory Pack Qty 1 TRENT(Fastron) Head Office Australia Datasheet Datasheet
-
HY 5-P Hall Effect Current Sensor, 5 Amp, +/-4V output, no aperture, +/-12..15V Supply, PCB Mount, X = 1%
Free Aus Post Shipping for $300 SpendHall Effect Current Sensor, 5 Amp, +/-4V output, no aperture, +/-12..15V Supply, PCB Mount, X = 1%
-
CT 143 L7 500/5 Amp CT 5VA, Class 1
Free Aus Post Shipping for $300 SpendHobut CT 143 L7 500/5 Amp CT 5VA Current Transformer Features DIN Rail Mounting Clip Included Built In Sealable Terminal Covers Mounting Feet Supplied Narrow Width (45mm) Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Hobut Part Number CT 143 L7 500/5 Technology AC Current Transformer Ratio 500/5 Aperture Size 21mm Busbar VA Rating 5VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Din Rail Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 500Amp x 1.2 Termination Style Screw Unit Weight 300g Factory Pack Qty 9 Datasheet Product Datasheet
-
TGLW26-1021315, 1 Pole Rotary Switch BLACK, 315 Amp 400VAC, Plastic, Direct Type, IEC60947-5-1
Free Aus Post Shipping for $300 SpendTGLW26-1021315, 1 Pole Rotary Switch BLACK, 315 Amp 400VAC, Plastic, Direct Type, IEC60947-5-1 Rotary Load Break or Disconnect Switches are used to Isolate or Switch under load. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation by the user. Features : 400VAC in various Ratings 1 Pole Momentary 64mm x 64mm Cutout Standards : IP40 IEC60947-5-1 CE Specification TRENT Part Number TGLW26-1021315 Functions 1 Pole AC Disconnect Nominal Voltage 400VAC @ 50/60Hz Rated Impulse Voltage 6kV Nominal Current Range AC 315Amp @400VAC Rated Insulation Voltage 690VAC Humidity 35-85% Approvals CE Standards IEC 60947-1,-3, IEC 60204, IP20 (IP40 Installed) Weight 4kg Enclosure Material UL94V0 Factory Pack Qty 1 TRENT(Fastron) Head Office Australia Datasheet Datasheet
-
TRI-22-G400, 22mm LED Indicator GREEN 400VAC, Plastic, IP65, IEC60947-5-1
Free Aus Post Shipping for $300 SpendTRI-22-G400, 22mm LED Indicator GREEN 400VAC, Plastic, IP65, IEC60947-5-1 LED indicator Series will activate while the contacts are connected to the rated voltage. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation and visual Indication by the user. Features : 400VAC or 24VAC/DC (400VAC Special Orders) LED Illumination Ø 22.5mm Cutout Long Life Replacement Beads Available Standards : IP65 IEC60947-5-1 CE Specification TRENT Part Number TRI-22-G400 Functions LED Indicator Only Nominal Voltage 230VAC @ 50/60Hz Impulse Voltage Wear Resistance 6kV Illumination Type Green LED Short Circuit Protection (Fuse) Recommend 10A gG Fuse Mechanical Compression Force at Closing 20N Mechanical Compression Force at Closing 8N Humidity 35-85% Approvals CE Standards IP65, IEC60947-5-1 Weight Enclosure Material UL94V0 Factory Pack Qty 1 TRENT(Fastron) Head Office Australia Datasheet Product Datasheet
-
TGLW26-1022315, 2 Pole Rotary Switch BLACK, 315 Amp 400VAC, Plastic, Direct Type, IEC60947-5-1
Free Aus Post Shipping for $300 SpendTGLW26-1022315, 2 Pole Rotary Switch BLACK, 315 Amp 400VAC, Plastic, Direct Type, IEC60947-5-1 Rotary Load Break or Disconnect Switches are used to Isolate or Switch under load. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation by the user. Features : 400VAC in various Ratings 1 Pole Momentary 64mm x 64mm Cutout Standards : IP40 IEC60947-5-1 CE Specification TRENT Part Number TGLW26-1022315 Functions 2 Pole AC Disconnect Nominal Voltage 400VAC @ 50/60Hz Rated Impulse Voltage 6kV Nominal Current Range AC 315Amp @400VAC Rated Insulation Voltage 690VAC Humidity 35-85% Approvals CE Standards IEC 60947-1,-3, IEC 60204, IP20 (IP40 Installed) Weight 4kg Enclosure Material UL94V0 Factory Pack Qty 1 TRENT(Fastron) Head Office Australia Datasheet Datasheet
-
CTSC CLIP 600/5 Amp CLIP Splitcore CT 5VA, Class 1, 38mm Aperture
Free Aus Post Shipping for $300 SpendHobut CTSC CLIP 600/5 Series Current Transformer Features Low Price Point Split Core 1m Flying Leads Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Flame Retardent UL94V0 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Site Measurements Specification Hobut Part Number CTSC CLIP 600/5 Technology Split Core AC Current Transformer Ratio 600/5 Aperture Size ⌀ 40mm VA Rating 5VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount Operating Temperature Range -30°C / 80°C Continuous Current (max) 600Amp x 1.2 Termination Style Screw Unit Weight 800g Factory Pack Qty 9 Datasheet Product Datasheet
-
FT010030P, 100/5 Amp Split Core CT, Class 1 1VA AC Current Transformer, 20 x 30mm Aperture, Dimension 90 x 40 x 110mm
Free Aus Post Shipping for $300 SpendFT010030P, 100/5 Amp Split Core CT, Class 1 1VA AC Current Transformer, 20 x 30mm Aperture, Dimension 90 x 40 x 110mm Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FT010030P Technology Split Core AC Current Transformer Ratio 100/5 Aperture Size 20 x 30mm VA Rating 1VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 100Amp x 1.2 Termination Style Screw Approvals UL, CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
-
TRBM-22D-B-240, 22mm Pushbutton Momentary BLUE 240VAC, Metal Body, IEC60947-5-1
TRBM-22D-B-240, 22mm Pushbutton Momentary BLUE 240VAC, Metal Body, IEC60947-5-1 Pushbutton Switches will activate while the contacts are connected. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation by the user. Features : 240VAC or 24VAC/DC (400VAC Special Orders) 1 Pole Momentary Rated for 6 Amp @ 230VAC, or 0.3 Amp @ 230VDC Ø 22.5mm Cutout Standards : IP40 IEC60947-5-1 CE Specification TRENT Part Number TRBM-22D-B-240 Functions Momentary Nominal Voltage 230VAC @ 50/60Hz Impulse Voltage Wear Resistance 6kV Short Circuit Protection (Fuse) Recommend 10A gG Fuse Nominal Current Range AC 6 Amp @240VAC Nominal Current Range DC 0.3 Amp @ 230VDC Mechanical Compression Force at Closing 20N Mechanical Compression Force at Closing 8N Humidity 35-85% Approvals CE Standards IP40, IEC60947-5-1 Weight Enclosure Material UL94V0 Factory Pack Qty 1 TRENT(Fastron) Head Office Australia Datasheet Product Datasheet
$13.00
$15.34 inclGST -
TGLW26-1023250, 3 Pole Rotary Switch BLACK, 250 Amp 400VAC, Plastic, Direct Type, IEC60947-5-1
Free Aus Post Shipping for $300 SpendTGLW26-1023250, 3 Pole Rotary Switch BLACK, 250 Amp 400VAC, Plastic, Direct Type, IEC60947-5-1 Rotary Load Break or Disconnect Switches are used to Isolate or Switch under load. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation by the user. Features : 400VAC in various Ratings 1 Pole Momentary 64mm x 64mm Cutout Standards : IP40 IEC60947-5-1 CE Specification TRENT Part Number TGLW26-1023250 Functions 3 Pole AC Disconnect Nominal Voltage 400VAC @ 50/60Hz Rated Impulse Voltage 6kV Nominal Current Range AC 250Amp @400VAC Rated Insulation Voltage 690VAC Humidity 35-85% Approvals CE Standards IEC 60947-1,-3, IEC 60204, IP20 (IP40 Installed) Weight 1.64kg Enclosure Material UL94V0 Factory Pack Qty 1 TRENT(Fastron) Head Office Australia Datasheet Datasheet
-
TGLW26-1022250, 2 Pole Rotary Switch BLACK, 250 Amp 400VAC, Plastic, Direct Type, IEC60947-5-1
Free Aus Post Shipping for $300 SpendTGLW26-1022250, 2 Pole Rotary Switch BLACK, 250 Amp 400VAC, Plastic, Direct Type, IEC60947-5-1 Rotary Load Break or Disconnect Switches are used to Isolate or Switch under load. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation by the user. Features : 400VAC in various Ratings 1 Pole Momentary 64mm x 64mm Cutout Standards : IP40 IEC60947-5-1 CE Specification TRENT Part Number TGLW26-1022250 Functions 2 Pole AC Disconnect Nominal Voltage 400VAC @ 50/60Hz Rated Impulse Voltage 6kV Nominal Current Range AC 250Amp @400VAC Rated Insulation Voltage 690VAC Humidity 35-85% Approvals CE Standards IEC 60947-1,-3, IEC 60204, IP20 (IP40 Installed) Weight 1.64kg Enclosure Material UL94V0 Factory Pack Qty 1 TRENT(Fastron) Head Office Australia Datasheet Datasheet