Fastron FDV-50-420-24, DC Voltage Transducer, Din Rail Mount, 0-150VDC, 4-20mA output, 24VDC Supply Voltage, 150mS Response
150mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 5V DC output (for voltage output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Part Number
FDV-50-420-24
Analogue Output
4-20mA
Input
0 - 50VDC
Measurement Range
120%
Overload
150% Continuous
Operating Temperature
-30 - 70°C
Operating Voltage
24VDC +/-15%
Voltage Isolation (1 min)
2.5kV
Accuracy
1%
Response Time
150mS
Termination Style
Screw
Mounting Style
DIN Rail Mount
Safety
CE, UL94V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
DC-0-5-420-1.0, Hall Effect DC Current Transducer, 0-5 Amp DC, 4-20mA Unipolar output, 24VDC supply
Compact and versatile Split Core DC current sensor, 0-5 Amp DC, 4-20 mA Unipolar Output
Other measurement ranges available on request
Features
⌀20mm Aperture
DC Unipolar Measurement
4-20mA analogue output
Busbar, or DIN Rail Mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Kit available
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
DC-0-5-420-1.0
Technology
DC Hall Current Sensor with Process Output
ROHS
Yes
Supply Voltage
24VDC
Nominal Current (DC)
0-5 Amp
Response Time
< 1uS
Output
Unipolar 4-20mA
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Mounting Style
DIN Rail Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Elevator Terminals
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet
FRS3-C40-600R-T2, 600VDC Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA WITH REMOTE C/O CONTACTS
Specifications
Trent part number
FRS3-C40-600R-T2
Nominal Voltage Un
600VDC
Max Operating Voltage
720VDC
No of Poles
3
Category IEC / EN / VDE
Type 2 (Class II)
Location of use
String Box, Inverter, Sub Board Only
Protection modes
(+)-PE,(-)-PE,(+)-(-) PE
Additional Remote Contacts
YES NO/NC/COM
Protective element
MOV
No Fault/Fault Indication
Green Flag / Not Green Flag
Surge discharge rating
Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal
Internal protection and safety
Thermal disconnector in each MOV
Weight
420g
Standards
IEC614643-31:2018 (TUV, CE Approved)
Datasheet
Product Datasheet
GDT/MOV/TVS Tester
SPD Tester
Fastron Electronics F13FT-2PL 12A 240VAC + F13F-2Z-C4 240VAC Series DPDT 12 Amp Form C AC/DC Relay, 240VAC Coil
Features
2 x 12 Amp @ 250VAC or 30VDC
DIN Rail Mount
Changeover Contact
Compatible with Omron G2R-2-S Series
UL Approved
CE Compliant to IEC 60664
IP20
Suits F13F-2Z-C4 Socket
Specification
Fastron Part Number
F13FT-2PL 12A 240VAC + F13FT-2Z-C4
Switching Type
2 x 30VDC or 250VAC (DPDT) Form C
Approvals
CE, UL
Control Voltage
240VAC
Load Current
2 x 12 Amp (rms)
Special Feature
LED Status Indicator
Mounting Style
DIN Rail Mount
Load Voltage Range
0-250VAC, 0-30VDC
Isolation
2.5kV
Termination Style
PCB or Socket Mount
Unit Weight
38g
Factory Pack Qty
20
Datasheet
Relay Datasheet
Replacement Relay
F13F-2PL 12A 240VAC
Replacement Socket
F13F-2Z-C4
Advanced Energy Basic Bus & dASM Modules, 8 Channel Communication Interface for Thyro Series SCR Controllers
Note: Basicbus not required For Thyro PX Controllers, only requires Anybus and dASM (for Dynamic Mains load optimised Burst Fire Modes)
Optional Connection for up to 8 Power Controllers (32 Optional)
One Address per Module
Access to controller setpoints, actual points, and parameters
Transfer of setpoints as float number in physical units
Control Function of LED's
24VDC 200mA Supply
UL and CE Approved
Thyro S, Thyro A, Thyro AX
Note Requires Anybus Module for dASM Mode(TAKT Control Only)
Communication Options :
Ethernet (Inc Ethern/IP/Profinet/Modbus TCP
Profibus DPV1
Modbus RTU
DeviceNet
Specification
Advanced Energy Part Numbers
2.000.190.002,2.000.190.003
Functions
Access to controller setpoints, actual points, and parametersTransfer of setpoints as float number in physical unitsControl Function of LED's
Supply Voltage
24VDC
Protocols
EthernetIP, Profinet, Modbus TCP ProfibusDPV1, ModbusRTU, DeviceNet (with Suitable Anybus Module)
No. of Communication Ports
Up to 8
Weight
750g
Factory Pack Qty
1
Approvals
CE, UL
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
User Manual
User Guide
Blog for initial communication setup issue
Setting Up Comms on Thyro A Series Controllers
Thyro Touch Software and Touch Display User Guide
Anybus Device Ethernet IP Setup Guide
FTA-020-24, DC Current Transducer, +/-20 Amp , +/-10VDC Output, 24VDC supply, 21mm Aperture
Compact and versatile Split Core DC current sensor, +/-20 Amp , +/-20VDC Bipolar Output
Features
⌀21mm Aperture
DC Bipolar Measurement
+/-10VDC Instantaneous output
120mS Response (for 0- +/-20mA ~+/-20A AC) 10uS Response (0-+/-20A ~+/-100A AC)
Busbar, or panel mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Kit available
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
FTA-020-010-24
Technology
DC Current Transducer with Instant Output
Yes
Supply Voltage
24VDC
Nominal Current (RMS + DC)
+/-20 Amp
Response Time
< 120mS
Output
Bipolar +/-10VDC Analogue
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Aperture
20mm
Mounting Style
Panel Mount
Operating Temperature Range
-10°C / 85°C
Accuracy
1%
Termination Style
4 Pin Plug (Included)
Unit Weight
300g
Factory Pack Qty
6
Datasheet
Product Datasheet
ATM-R-CT-H-D-1, Frequency Transducer, 0.001Hz to 10kHz Contact Input, 22-60VDC Aux, 4-20mA output
Adjustable Zero and Span Setting
Digital DIsplay
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) or 0-10V/0-5V (For Direct Voltage Type)
Each unit needs just 50mm x 120mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
ATM-DAO(20-4mA)-C-1
Control Output
4-20mA
Input
Contact 0.001Hz to 10kHz
Over Range
N/A
Operating Temperature
0 - 60°C
Load Voltage
22-60VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics GTD-D-C-SP03, 0-300VDC Voltage Transducer/Transmitter, 22-60VAC/DC aux, 4-20mA output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GTD-D-C-SP03
Control Output
4-20mA
Input
0 - 300VDC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
22 - 60VDC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics BTCS/S-M1-A2, PID Controller 48x48mm, 15-50VDC, SSR output 2 Alarms, Multirange TC/RTD/SSR 24VDC @ 30mA Input
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Dust-proof IP56 (front panel only)
Optional 32 Step pattern (for SV and time) is a standard feature
CE Approved
Each unit needs just 80 mm depth panel space
Specification
Fastron Part Number
BTCS/S-M1-A2
Control Output
SSR 24VDC @ 30mA
Input
Multirange SSR 24VDC @ 30mA/RTD/Thermocouple (Optional Linear Voltage/Current other than SSR 24VDC @ 30mA Refer to datasheet)
Option 1
2nd Alarm
Option 2
None
Mounting Style
48x48mm Panel Mount
Load Voltage Range
15-50VDC
Termination Style
Screw
Weight
250g
Factory Pack Qty
1
CE
Yes
Datasheet
BTC Series Brochure
BTC Series User Manual
BTC Series RS485 Comms Manual
Fine Tuning PID Adjustments
FRS3-C40-500R-T2, 500VDC Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA WITH REMOTE C/O CONTACTS
Specifications
Trent part number
FRS3-C40-500R-T2
Nominal Voltage
500VDC
No of Poles
3
Category IEC / EN / VDE
Type 2 (Class II)
Location of use
String Box, Inverter, Sub Board Only
Protection modes
(+)-PE,(-)-PE,(+)-(-) PE
Additional Remote Contacts
YES NO/NC/COM
Protective element
MOV
No Fault/Fault Indication
Green Flag / Not Green Flag
Surge discharge rating
Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal
Internal protection and safety
Thermal disconnector in each MOV
Weight
420g
Standards
IEC614643-31:2018 (TUV, CE Approved)
Datasheet
Product Datasheet
GDT/MOV/TVS Tester
SPD Tester