Fastron Electronics SCT-F50-200, 0.333V, 200Amp measurement Split Core CT's
Features
Quick Release Split Core System
Cable Mount
0.333V Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F50-200
Technology
Split Core AC Current Transformer
Ratio
200/0.333V
Aperture Size
ø 50 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333V (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
200Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
200g
Factory Pack Qty
9
Datasheet
Product Datasheet
Stocked Split Core CT's Listing
Application Notes
Installation Guide
Types of Current Transformers - Blog
Cable Losses and CT's
High Accuracy or High Burden Requirements for CT's
Fastron Electronics GTD-2A6-A-11/SP1, Signal Isolator/Conditioner, 4-20mA Loop Supplied Input, Dual 4-20mA Outputs, 100-240VAC/DC, TROPICALIZED CIRCUIIT BOARD
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted from 4 to 20 mA DC Loop Supply (Sensor Input) to insulated 4-20mA Standard Process Output
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GTD-2A6-A-11/SP1
Control Output
2 x 4-20mAÂ
Input
4-20mA Sensor Input (Loop Powered)
Special Feature
SP1 = Tropicalized Circuit Board
Over Range
x 1.5
Operating Temperature
0 - 60°C
Supply Voltage
100-240VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Taisuo TMD-N7611 PID Controller, 100-240VAC with 1 Alarm, RS485, E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 72x72mm, SCR Trigger Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Specification
Taisuo Part Number
TMD-N7611
Control Output
SCR/AC Switch Trigger (Single Phase)Â
Input
Multirange Type,E,J,N,T,S,R,B, Pt100, Cu50/(Optional)Linear Current 4(0)-20mA/(Optional)Linear Voltage 0-10(5)V
Option 1
1 Alarm
Mounting Style
72x72mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
250ms
Weight
150-270g
Factory Pack Qty
1
Â
Datasheet
FC5 Datasheet and User Manual
Crydom D2425T, Solid State Relay, Single Phase 3-32VDC Control, 25A, 24-280VAC Load, Gen 3 Photo Transistor Isolation
Features
Ratings from 25A to 125 Amp @ 24-280 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
D2425T
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
3-32VDC
Load Current
25 Amp (rms)
Surge Capability
239 Amp (peak)
Special Feature
Gen 3 Photo Transistor Isolation
Mounting Style
Panel Mount
Load Voltage Range
24-280VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Â
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent
With Gen 4 Isolation.
D2450
HD4850
CY9008
CWD2450P
HD6050
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
E62.P17-124C20, 120uF, Heavy Duty AC Film Capacitor ø95 x 176mm, M6x12 terminals with Bushing. C2 Design, 850VAC/1400VDC
Characteristics and utility
120uFÂ 850VAC/1400VDC,
Metalized Polypropylene Film
Connector type - M6 x 12mm Studs
M12 Stud mounting
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
Electronicon Part Number
E62.P17-124C20
Technology
Metalized Polypropylene Film Capacitor
Dimensions
ø95 x 176mm
Mounting
M12 Stud
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
850VAC/1400VDC,
Operating Temperature Range
-40 to 85 °C
Capacitance
120uF
Tolerance On Capacitance
+10 / -10%
Lifetime
200,000 Hours @ 85 °C (Statistical Life)
Termination Style
M6 x 12 studs
Unit Weight
1.3kg
Factory Pack Quantity
21 (MOQ = 105)
Â
Datasheet
Product Datasheet
FBS LCD 12/4M, 12VDC Pluggable Surge Protection Device for IT Systems, LPZ 0A-2 of higher, 10kA, for Balanced and Unbalanced systems
Â
Specifications
Telebahn part number
FBS LCD 12/4M
Nominal Voltage
12VDC
No of Poles
4
Category IEC / EN / VDE
Type 2
Location of use
Communication/Signal Lines
Protection modes
L1+/L1-, L2+/L2- , forÂ
Additional Remote Contacts
NO
Protective element
MOV
No Fault/Fault Indication
N/A
Surge discharge rating
Per pole 10kA (8/20uS)10KA) Max, 20kA (8/20uS)2.5KA)Â Nominal
Internal protection and safety
Thermal disconnector in each MOV
Weight
120g
Standards
IEC 61643-21; EN 61643.21; GB 18802.21
Â
Datasheet
Product Datasheet
GDT/MOV/TVSÂ Tester
SPD Tester
Fastron FC5-L-W-1-G-4-C PID Controller, 24VDC with 1 Alarm, RS485 Comms, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 96x96mm, Dual Relay and SSR Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
FC5-L-W-1-G-4-C
Control Output
Relay and SSR (Dual Ouptut)
Input
Multirange Type K, J, E,S,T,R, Pt100, Cu50/Linear Current 4(0)-20mA/Linear Voltage 0-10(5)V
Option 1
1Â Alarm, RS485 Comms
Mounting Style
96x96mm Panel Mount
Supply Voltage
24VDCÂ +/-15%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Â
Datasheet & User Manual
Datasheet
User Manual
FC5 Communication Protocol
Fastron Electronics GT-DVO(0-60V)A-1, Signal Isolator/DC Voltage Transducer, 0-60VDC input, 100 - 240VAC aux, 4-20mA output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GTD-DVO(0-60V)A-1
Control Output
4-20mA
Input
0 - 60VDC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
100 - 240VAC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
FTA-020-24, DC Current Transducer, +/-20 Amp , +/-10VDC Output, 24VDC supply, 21mm Aperture
Compact and versatile Split Core DC current sensor, +/-20 Amp , +/-20VDC Bipolar Output
Features
⌀21mm Aperture
DC Bipolar Measurement
+/-10VDC Instantaneous output
120mS Response (for 0- +/-20mA ~+/-20A AC) 10uS Response (0-+/-20A ~+/-100A AC)
Busbar, or panel mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Kit available
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
FTA-020-010-24
Technology
DC Current Transducer with Instant Output
Yes
Supply Voltage
24VDC
Nominal Current (RMS + DC)
+/-20 Amp
Response Time
< 120mS
Output
Bipolar +/-10VDC Analogue
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Aperture
20mmÂ
Mounting Style
Panel Mount
Operating Temperature Range
-10°C / 85°C
Accuracy
1%
Termination Style
4 Pin Plug (Included)
Unit Weight
300g
Factory Pack Qty
6
Â
Datasheet
Product Datasheet
TGD-22SM-R-230, 22mm RED LED Flasher/Indicator and Audible Alarm Buzzer, 240VAC, Plastic
LED indicator Series will activate while the contacts are connected to the rated voltage. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation and visual Indication by the user.
Features :
240VAC Supply
LED Illumination
Ø 22.5mm Cutout
Long Life
LED Replacement Beads Available
RED, GREEN, AMBER, BLUE, or Clear\White Colour
Standards :
IP40
IEC60947-5-1
CE
Specification
TRENT Part Number
TGD-22SM-R-230
Functions
LED Indicator and Audible Alarm
Nominal Voltage
230VAC @ 50/60Hz
Impulse Voltage Wear Resistance
6kV
Illumination Type
RED LED
Short Circuit Protection (Fuse)
Recommend 10A gG Fuse
Mechanical Compression Force at Closing
20N
Mechanical Compression Force at Closing
8N
Humidity
35-85%
Approvals
CE
Standards
IP65, IEC60947-5-1
Weight
Enclosure Material
UL94V0
Factory Pack Qty
1
TRENT(Fastron) Head Office
Australia
Â
Datasheet
Product Datasheet