Search results for "텔레@upcoin24``이더리움전송대행리플매입"
-
Thyro-A-3A-400-16-H-RLP3, Three Phase SCR Controller 16 Amp 400VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control, Current Feedback, Power Limit Options
Advanced Energy Thyro-A-3A-400-16-H-RLP3, Three Phase SCR Controller 16 Amp 400VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control, Current Feedback, Power Limit Options Features 400VAC +10/-57% Line to Line Voltage, Current or Power Control Smallest footprint on the market Built in Fuses 3 Phase, Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover USB Configuration/Bias Setting Potentiometer Adjustments Synchronisation Function for Multiple TAKT Sync Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode Resistive Loads up to 6:1 Hot/Cold Ratio AC Soft Starter (VAR Mode Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro-A-3A-400-16-H-RLP3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Three Phase AC Switch Control Modes Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request) Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-57% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 74kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$3,545.30
$4,183.45 inclGST -
N1159NC400, Thyristor(SCR) PUK, 1159Amp, 4200V, 74/26
Free Aus Post Shipping for $300 SpendWestcode-IXYS-Littlefuse N1159NC400, Thyristor(SCR) PUK, 1159Amp, 4200V, 74/26 Features Very low forward voltage drop Very low leakage current International standard package 74/26 Package Press Mounted Double or Single Sided Cooling Applications Power Supplies Rectifier for drives applications Uncontrolled Rectifiers Rectifiers for UPS Battery Chargers Field Supply for DC Motors Water Cooled Rectifiers DC Substation Blocking Diode Large Generators Specification Westcode-IXYS-Littlefuse Part Number N1159NC400 Vrrm 4000V Diode Configuration Thyristor Capsule (PUK) IF(av) @ 60 Deg C 1159 Amp Package Size ø74 x 26mm Itsm 14.5 kA VF(to) 1.1V Tj(max) 125°C rF 0.574mΩ Gate Terminals Faston R th(j-c) (double sided cooled 180°sin) 0.022°C/W R th(c-h) (double sided cooled) 0.044°C/W Weight 510g Clamping Force 19 - 26kN Factory Pack Qty 6 Certification ROHS Westcode-IXYS-Littlefuse Headquarters UK Datasheet Product Datasheet Alternatives DCR1260F42 Contact Us for Possible Replacement Heatsink Heatsink Profiles
-
MG73BQ 3 Phase 4 Wire or Single Phase Voltage Monitoring Relay With DPDT Contacts, Undervoltage, Selectable Overvoltage, 3 x 120-240 VAC
Free Aus Post Shipping for $300 SpendGIC Controls MG73BQ 3 Phase 4 Wire or Single Phase Voltage Monitoring Relay With DPDT Contacts, Undervoltage, Selectable Overvoltage, 3 x 120-240 VAC Relay control, on 3-phase networks : Overvoltage between phases, Undervoltage between phases Overvoltage between phases and neutral, Undervoltage between phases and neutral, Loss of neutral Multi-voltage Products Controls its own supply voltage True RMS measurement LED status indication 3-phase voltage controllers which monitor : Undervoltage, adjustable from -20 to -2 % of Un Overvoltage, adjustable from 2 to 20 % of Un Measurements are taken between neautral and Phases for MG73BQ MG73BQ and between Phases and Neutral for the H3USN Faults are signalled via LEDs, distinguishing the origin of the fault (one LED for the upper threshold, one LED for the lower threshold). Set the selector switch to the 3-phase network voltage Un. The position of this selector switch is only taken into account when the unit is powered up. If the switch position changes while the unit is operating, all the LEDs flash but the product continues to work normally with the voltage selected on energisation prior to the change of position. The LEDs return to their normal state if the switch is reset to its initial position defined before the last energisation. Specification GIC Controls Part Number MG73BQ (3 Phase 4 Wire/Single Phase Monitoring Relay With DPDT Contacts) Function Undervoltage/Overvoltage between phases Nominal Voltage 3 x 120 → 3 x 240 V ∿ Digital Outputs 2 x C/O Relays, 250VAC/DC @ 5 Amp Min Breaking Current 10mA/5VDC Timing Range 0.3 → 30s (0, +10%) Delay on Pickup 500ms Alarm Delay on Time (max) 200ms Reset Time 1500ms Fixed Hysteresis 2% of Un Maximum Measurement Cycle Time 150ms/True RMS Measurement Measurement Accuracy 1% Supply Voltage Range Same as Measurement 3 x 220 → 3 x 480 V ∿ Termination Style Screw Weight 170g Certification CE, UL, CSA, GL, ROHS Factory Pack Qty 1 Over Voltage Category 3 in accordance with IEC/EN 60664-1 Pollution Degree 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Mechanical Resistance Immunity to vibrations IEC/EN 60068-2-6, test Fc Immunity to shock IEC/EN 60068-2-27, test Ea Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22 Datasheet Product Datasheet
-
11.212.935 AMJ5265 MAHLE - Letrika Unidirectional CW 12VDC Motor, 1.6kW, 2600rpm
Heavy Item - No free ShippingISKRA LETRIKA (MAHLE) 11.212.935 AMJ5265 MAHLE - Letrika Unidirectional CW 12VDC Motor, 1.6kW, 2600rpm MAHLE Part # MM 191 11212.958 11212958 IM0055 Specification ISKRA (MAHLE) Part Number 11.212.935 AMJ5265 MAHLE ISKRA/LETRIKA/MAHLE IM0050, 11212935, AMJ5265, MM273, 11212112, AMJ5669, 11212082, AMJ5646, 11212075, AMJ5641 Voltage 12VDC Power 1.6kW Rotation Unidirectional Clockwise Rotation Speed 2600 rpm Unit Weight 6.9kg Factory Pack Qty 1 Cross Reference FLUITRONICS (BERENDSEN) 1240247, 9000566912 LUCAS 47044608 MAHLE LETRIKA (ISKRA) IM0050, 11212935, AMJ5265, MM273, 11212112, AMJ5669, 11212082, AMJ5646, 11212075, AMJ5641 SPX FLUID POWER (FENNER) MF4034 MAKE MODEL TYPE ENGINE POWER YEARS BUCHER HYDRAULICS (HIDROIRMA) PEDRO ROQET SPX FLUID POWER (FENNER) WEBER Spare Parts Spare Parts Page
-
D5810N04, Rectifier Diode PUK 5800Amp, 400V, 74/26
Free Aus Post Shipping for $300 SpendInfineon D5810N04 Rectifier Diode Capsule Features Very low forward voltage drop Very low leakage current International standard package 74/26 Package Press Mounted Double or Single Sided Cooling Applications Power Supplies Rectifier for drives applications Uncontrolled Rectifiers Rectifiers for UPS Battery Chargers Field Supply for DC Motors Water Cooled Rectifiers DC Substation Blocking Diode Large Generators Specification Infineon Part Number D5810N04 Vrrm 400V Diode Configuration Diode Capsule (PUK) IF(av) @ 85 Deg C 5800 Amp Package Size ø74 x 26mm Itsm 81 kA VF(to) 0.7V Tj(max) 180°C rF 0.04mΩ Gate Terminals N/A R th(j-c) (double sided cooled 180°sin) 0.0166°C/W R th(c-h) (double sided cooled) 0.0025°C/W Weight 530g Clamping Force 30 - 60kN Factory Pack Qty 12 Certification ROHS Infineon Headquarters Germany Datasheet Product Datasheet Alternatives w7045mc060 Heatsink Heatsink Profiles
-
Thyro-A-3A-400-350-HF-RLP3, Three Phase SCR Controller 350 Amp 400VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control, Current Feedback, Power Limit Options
Advanced Energy Thyro-A-3A-400-350-HF-RLP3, Three Phase SCR Controller 350 Amp 400VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control, Current Feedback, Power Limit Options Features 400VAC +10/-57% Line to Line Voltage, Current or Power Control Smallest footprint on the market Built in Fuses 3 Phase, Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover USB Configuration/Bias Setting Potentiometer Adjustments Synchronisation Function for Multiple TAKT Sync Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode Resistive Loads up to 6:1 Hot/Cold Ratio AC Soft Starter (VAR Mode Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro-A-3A-400-350-HF-RLP3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Three Phase AC Switch Control Modes Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request) Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-57% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 74kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$10,967.22
$12,941.32 inclGST -
DTC1-S/M-C5, DIN Rail Mount Temperature/Humidity Controller, Multirange Input, 85-265VAC, 12VDC SSR Output, RS485 Modbus RTU
Free Aus Post Shipping for $300 spendFastron DTC1-S/M-C5, DIN Rail Mount Temperature/Humidity Controller, Multirange Input, 85-265VAC, 12VDC SSR Output, RS485 Modbus RTU Optional converter function 2 Input 1 Output, and 1 Input Two Output Versions available Optional 60 Segment Multi Pattern Program Control feature 4-digit display. Suit most industries including Temperature, Humidity, Pressure (0.5s response) CE Approved Each unit needs just 22.5mm width Din Rail space EC Compliant (Details) Various specials available for unique applications. Specification Fastron Part Number DTC1-S/M-C5 Control Output SSR 12VDC@30mA Input Multirange K/J/R/S/B/E/T/Linear Voltage Current(Optional)/N/W1/W2/Pt100 Alarm Relay 3A(Resistive), 1A(Inductive load cos ??=0.4), 240VAC/30VDC Options RS485 Comms Mounting Style 22.5 x 75mm Din Rail Mount Supply Voltage 85 - 265VAC Termination Style Screw Weight 230g Factory Pack Qty 1 CE Yes ?? Selection Chart PWM Control Wiring Datasheet DTC1 Brochure DTC1User Manual DTC1 User Manual Comms versions Alarm Table DTC1 (Program Control Version) User Manual
-
Thyro-A-3A-400-170-H3, Three Phase SCR Controller 170 Amp 400VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control only
Advanced Energy Thyro-A-3A-400-170-H3, Three Phase SCR Controller 170 Amp 400VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control only Features 400VAC +10/-57% Line to Line Voltage, Current or Power Control Smallest footprint on the market Built in Fuses 3 Phase, Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover USB Configuration/Bias Setting Potentiometer Adjustments Synchronisation Function for Multiple TAKT Sync Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode Resistive Loads up to 6:1 Hot/Cold Ratio AC Soft Starter (VAR Mode Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro-A-3A-400-170-H3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Three Phase AC Switch Control Modes Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request) Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-57% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 74kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$6,112.70
$7,212.99 inclGST -
DCM230 1-4-1-1 V1, DIN Rail Mount DC kWh Meter, 85-265VAC, 85-265VAC aux, Class 1, 45/60/75mV Shunt Connect, w/ 1 x pulse outputs and RS485 Modbus RTU Comms, Single Tariff, MID Approved
DCM230 1-4-1-1 V1, DIN Rail Mount DC kWh Meter, 85-265VAC, 85-265VAC aux, Class 1, 45/60/75mV Shunt Connect, w/ 1 x pulse outputs and RS485 Modbus RTU Comms, Single Tariff, MID Approved 45/60/75mV Shunt Connect RS 485 communication up to 38,400 bit/s as standard 1 x Pulse Outputs (1 Configurable) Bidirectional Measurement The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records DC Current and Voltage (DC Power) value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, energy, power) from the measured signals. Features : Accuracy class 1 Measurement of Active and Reactive Power Modbus RTU communication up to 38,400 bit/s communication Pulse output as standard Graphic LCD with illumination Specification Eastron Europe Part Number DCM230 1-4-1-1 V1 Functions DC Energy Meter Supply Voltage 85-265VAC Nominal Measurement Range 5-60VDC Maximum Measurement Range 5-60VDC Nominal Current Input Shunt up to 2000Amp See our DC Current Shunt Section for Suitable Shunt Pulse Output 1 x Configurable 60/100/200ms Tariff Input N/A Accuracy Class 1 (I,U,kW,kWh) Mounting Din Rail Real Time Clock 1min/month (30ppm) Internal Memory N/A Dimensions 36mm x 100mm x 66mm (2 modules wide) Isolation 4kV RS485 2400-38400 b/s Weight 250g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Safety IP51(Indoor) Enclosure Material Noryl with fire protection to UL94-V-O. Self extinguishing Enclosure Size DIN 42880 4 Modules Operating Temperature -20 →+70 °C Documents Product Datasheet User Manual Modbus Utility EEM Meter Setting Software Utility
$249.00
$293.82 inclGST -
G64C741, HV Relay, 50kVDC, 10A, SPDT Form C, 24VDC Coil, 1,000,000 Cycles, 55kV Isolation, 12" Flying Leads
Free Aus Post Shipping for $300 SpendGigavac G64C741, HV Relay, 50kVDC, 10A, SPDT Form C, 24VDC Coil, 1,000,000 Cycles, 55kV Isolation, 12" Flying Leads Features Hermetically Sealed (Patented) rated to 85 Deg C High Efficiency Form C DC Coil Gas filled Small and lightweight Flexible package for installation Specification Gigavac Part Number G64C741 Main Contact Type SPDT-Form C Auxiliary Contact Type N/A Coil Voltage 24VDC Load Current 10 Amp Mechanical Life @ 0 Amp 1,000,000 Operations Nominal Load Voltage 50kV rms Control Input Terminals 12" Flying Leads Special Feature N/A Mounting Style Panel Mount (M4) Peak Voltage 55kVDC Standards UL508, NEC 690.11 and 690.12 DC Termination Style Screw Unit Weight 335g Factory Pack Qty 1 Datasheet Product Datasheet
-
FTA-045-420B-24, Hall Effect DC Current Transducer, +/-45 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture
FTA-045-420B-24, Hall Effect DC Current Transducer, +/-45 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-20 Amp , 4-20mA Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- +/-20mA ~+/-20A AC) 10uS Response (0-+/-20A ~+/-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-015-420B-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-45 Amp Response Time < 120mS Output Bipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
FTA-050-010-24, Hall Effect DC Current Transducer, +/-50 Amp , +/-10VDC Output, 24VDC supply, 21mm Aperture
FTA-050-010-24, Hall Effect DC Current Transducer, +/-50 Amp , +/-10VDC Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-50 Amp , +/-10VDC Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement +/-10VDC Instantaneous output 120mS Response (for 0- +/-10mA ~+/-10A AC) 10uS Response (0-+/-50A ~+/-100A AC) Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-050-010-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-50 Amp Response Time < 10uS Output Bipolar +/-10VDC Analogue Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST