LHAIS 100-P, O/L Hall Effect Current Sensor, 100 Amp, Vref 0-5V Output, PCB Mount, 15x8mm sqr, X = 1%
Features
Bandwidth DC to 50kHz
Open loop transducer using Hall effect
Compact and versatile
Panel mounting-Horizontal or Vertical
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Wide dynamic range, 50 to 600 A in one package.
Applications
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Specification
LEM Part Number
HAIS 100-P
Technology
Open Loop Hall Effect
Aperture
15 x 8mm Square
ROHS
Yes
Supply Voltage
5 VDC
Load Current (RMS + DC)
100 Amp
Overload Capability
+/- 300 Amp
Output
2.5 Vref
Isolation
2.5kV
Bandwidth
DC-50 kHz
Mounting Style
PCB Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
PCB
Unit Weight
30g
Factory Pack Quantity
10
Datasheet
Product Datasheet
LEM LXS 25-NPS Closed Loop AC/DC Hall Effect Sensor
Features
Closed loop current transducer
Voltage output
4.3kV Isolation
Frequency bandwidth 300kHz
Single supply + 5 V
Galvanic isolation between primary and secondary
Low power consumption
Compact design for PCB mounting
Vref IN Vref OUT
Multirange through PCB routing
Advantages
LXSR footprint compatible
Zero insertion losses
Very good linearity
Very good dv/dt immunity
High immunity to external intereference
Current overload capability
Optimised response time
Applications
AC variable speed and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Standards
EN 50178: 1997
UL 508: 2013
IEC 61010-1(safety)
Application Domain
Industrial
Specification
LEM Part Number
LXS 25-NPS
Technology
Closed Loop Multirange Hall Effect
Aperture
ø3.2mm
ROHS
Yes
Supply Voltage
5 VDC
Load Current (RMS + DC)
25 Amp
Measurement Range
+/-85 Amp
Output
2.5 Vref
Isolation
4.3 kV
Bandwidth
DC-300 kHz
Mounting Style
PCB Mount
Operating Temperature Range
-40°C / 105°C
Accuracy
2.25%
Termination Style
PCB
Unit Weight
10g
Factory Packaging
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Alternatives
LTS 25-NP
MC330 H ARNG SUDMNAT, Panel Mount Multifunction Meter, Class 0.5, 50-500VAC Autorange, 61 Parameter (U, I, P, Q, S, PF, PA, f, ϴ, THD, MD …), 4 Energy Counters, 2 x Relay Outputs 0-20mA, RS485 Comms, Universal 20-300VDC, 48-276VAC Aux, Internal Logger
Internal 8MB Logger
Universal AC/DC Power Supply
Automatic range of nominal current up to 12.5 A (Includes 5A/1A CT Input) and nominal voltage up to 500 V L-N
Adjustable tariff clock, display of electric energy consumption in optional currency
Optional RS 232/RS 485 communication up to 115,200 bit/s
RMS values of currents and voltages
Measurements of active, reactive, apparent power and power factor
Measurements of energy in all 4 quadrants Average values of measurands per interval
The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.
Features :
Internal Logger
Measurement of instantaneous values of more than 60 quantities (U, I, P, Q, S, PF, PA, f, f, MD, etc.).
Accuracy class 0.5
Measurement of 20 minimal and maximal values in different time periods
Optional dual tariff inputs and pulse or relay outputs
Wide frequency range from 16 Hz to 400 Hz
RS 232/RS 485 communication up to 115,200 bit/s or Ethernet communication
MODBUS communication protocol
Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs)
Universal or AC power supply
Graphic LCD 128 x 64 dots with illumination
Automatic range of nominal current up to 5 A and nominal voltage up to 600 V
Multilingual support
User-friendly PC MiQen software
Specification
Iskra Doo Part Number
MC330 H ARNG SUDMNAT
Functions
Power Quality Meter, Energy Meter
Supply Voltage
Universal 20-300VDC, 48-276VAC < 5VA
Nominal Measurement Range
500V L-N, 5 Amp
Maximum Measurement Range
600V L-N, 12.5 Amp
Alarm
2 x Analogue Outputs 0-20mA
Tariff Input
N/A (Optional 4 x )
Accuracy
Class 0.5 (I,U,F,PF,θ,THD) Class 1(Active), Class 2 (Reactive)
Battery Backup
N/A
Real Time Clock
1min/month (30ppm)
Isolation
3.5kV
RS232/RS485
2400-115200 b/s
Weight
500g
Certification
UL, CSA, ROHS
Factory Pack Qty
1
EU Directives
Degree on electrical equipment designed for use within certain voltage limits URLRS 53/00 (Directive 73/23/EEC on low voltage): SIST EN 61010-1:2002
Safety Requirement for electrical equipment for measurement, control and laboratory use, part1 : general requirement
Decree on electromagnetic Compatibility (EMC) URLRS 61/00 (Directive 89/336/EEC on electromagnetic compatibility): SIST EN 61036 item 4.5: 1998 Meters for active energy (class 1 and 2)
Safety
Protection Class II
600V rms, installation category II
300V rms, installation category III
Pollution Degree 2 in compliance with SIST EN 61010-1:2002
Enclosure Material
PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0
Enclosure Protection
IP52 (IP00 for terminals) in compliance with SIST EN 60529:1997
Resistance to HF Interference
Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12
Conducted and radiated emissions
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
User Manual
1/8" BSPT x 5mm Compression Fitting for use with RTD or Thermocouple, SS 304 Body with Brass Compression Ring Insert
Tapered 1/8" BSP x 5mm
Stainless Steel
BSPT vs NPT Sizes
BSPT vs NPT Fittings
Fastron FRTD-6-3-750-2500 Resistance Temperature Detectors (RTD's)
Class A Accuracy
Teflon Screened Cable
Low Long Term Drift
Rated for -50 to 350 Deg C Max
Spring Cable Connection
2500 x 3mm (6 x 50mm Tip)
MIMS
Recommended to use BSP Fitting for mounting
Specification
Fastron Part Number
FRTD-6-3-2500-75
Sensor Type
RTD - Resistance Temperature Detectors
No of Wires
4
Shaft Length
2500mm
Shaft Thickness
3mm (6mm Tip)
Accuracy
Class A
Cable length
750mm
Cable Type
Teflon/Screened/Teflon
Temperature Range
-50 to 350 Deg C
Special Feature
6 x 50mm Tip
Mounting Style
BSP Bayonet or Flange Fitting Recommended
Weight
800g
Factory Pack Qty
1
Datasheet
ST6613 Rev 3
Trent NBR-CH14/UQ/25A/690V Series 25 Amp 690V Semiconductor I²t Fuse Cartridge Style 51 x 14mm
Features
Cylindrical Standard Fuses Sizes
Wide Range of I²t
Ratings up to 63 Amp
Quick Release with RT18-63L fuse holder
DIN Rail Mount with RT18-63L fuse holder
Compatible with all 51 x 14mm fuse holders
IEC Standard 60269.1 AND 4
690 V Voltage Rating complying with IEC 33
Applications
Solid State Relay Switchboards
Bridge rectifier Fusing
Protection of High Powered Semiconductors according to I²t
Short Circuit Protection
DC or AC Motor I²t Protection
Battery Fuse
Specification
Trent Part Number
NBR-CH14/UQ/25A/690V
Fuse Type
I²t gR Class
Nominal Voltage
690VAC @ 50Hz
I²t Rating (Pre-Arcing)
320 A²/s
Nominal Current (RMS + DC)
25 Amp
Tested Breaking Capacity
200kA @ 690VAC
Dimensions
51 x 14mm
Fuse Holder
RT18-63L
Mounting Style
Requires fuse holder
Operating Temperature Range
-40°C / 125°C
Watt Loss
7.6W
DC Breaking Capacity
50kA
Unit Weight
42g
Factory Pack Qty
10
Datasheet
Product Datasheet
Compatible Fuse Holder
RT18-63L
Datasheet
Fastron 04F-SP-NC-AL, Split Core AC Current Switch, Multirange 1-10A, 10-50A, 50-200Amp Self Powered, 10% Accuracy, Minimum Threshold 1.5 +/-0.2 Amp Average RMS Current Sensing, Normally Closed Contacts, 1Amp @ 240VAC Adjustable Trip
Compact and versatile current switches for detection of AC Currents, Multirange 1-10Amp, 10-50Amp, 50-200Amp via jumper
Features
Self Powered
Multirange selector
Panel mounting
Eliminates insertion loss
Isolated plastic case recognised according to UL94-V0
Advantages
Highly accurate low current measurement down to 1Amp
High isolation between primary and secondary circuits
Easy installation
Applications
Fault Detection
Motor or Fan Protection
Application Domain
Energy and Automation
Specification
Fastron Part Number
04F-SP-NC-AL
Technology
Split Core AC Current Transformer
Alarm Type
NC Relay 1Amp @ 240VAC
Supply Voltage
Self Powered
Load Current (RMS)
Multirange 1-10A, 10-50A, 50-200Amp
Trip Point
Adjustable
Isolation
2kV (AC, 50Hz, 1 min)
Bandwidth
50/60Hz
Mounting Style
Panel Mount
Operating Temperature Range
-25°C / 70°C
Accuracy
10% (Minimum Threshold 1.5 +/-0.2 Amp)
Termination Style
Screw Terminals
Unit Weight
200g
Certifications
UL E320368, CE, Rohs compliant
Datasheet
Product Datasheet
Trent 15AF Series 690V, 15 Amp aR Semiconductor I²t Fuse BS88 Style
Features
British Standard Fuse Links Package
Wide Range of I²t
Ratings up to 1000 Amp
Busbar or Standoff Mounting
IEC Standard 60269.1 AND 4
690 V Voltage Rating complying with IEC 33
Applications
Protection of High Powered Semiconductors according to I²t
Short Circuit Protection
DC or AC Motor I²t Protection
Battery Fuse
Specification
Trent Part Number
15AF
Fuse Type
I²t AR Class
Nominal Voltage
690VAC @ 50Hz
I²t Rating (IP < 30IN)
55 A²/s
I²t Rating (IP > 30IN)
95 A²/s
Nominal Current (RMS + DC)
15 Amp
Tested Breaking Capacity
200kA @ 690VAC
Dimensions
17 x 49mm
Hole Centers
60.9 - 65.6mm
Mounting Style
Busbar or Panel Mount with Standoff
Operating Temperature Range
-40°C / 125°C
Watt Loss
4.8W
Termination Style
M6
Unit Weight
61g
Factory Pack Qty
10
Datasheet
Product Datasheet
Cross Reference Chart
Trent 630EU690V-100kA Series 690V Semiconductor I²t Fuse European Blade NH Type (Replaces NH3 TF Shaltvermogen)
Features
Square Body DIN 43 653
Wide Range of I²t
Ratings up to 2000 Amp
Fuse Holder Mounted
IEC Standard 60269.1 AND 4
690 V Voltage Rating complying with IEC 33
Applications
Protection of High Powered Semiconductors according to I²t
Short Circuit Protection
DC or AC Motor I²t Protection
Battery Fuse
Specification
Trent Part Number
630EU690V-100kA
Fuse Type
I²t AR Class HRC
Nominal Voltage
690VAC @ 50Hz
I²t Rating (660V)
Nominal Current (RMS + DC)
630 Amp
Tested Breaking Capacity
200kA @ 690VAC
Dimensions
69 x 150 x 69mm (NH3)
Indicator
Tag
Mounting Style
Fuse Holder
Operating Temperature Range
-40°C / 125°C
Watts Dissipation
90WW
Termination Style
Blade Fuse Holder
Unit Weight
400g
Factory Pack Qty
3
Datasheet
Product Datasheet