TGLW30-3D25, 3 Pole Rotary/CAM Switch RED, 400VAC, Plastic, Direct Type, IEC60947-5-1
Rotary CAM Switches are used to Isolate or Switch under load. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation by the user.
Features :
400VAC in various Ratings
3 Pole 2 Position
64mm x 64mm Cutout
Standards :
IP40 Front, IP20 Terminals
IEC 60947-1,-3
IEC 60204
Specification
TRENT Part Number
TGLW30-3D25
Functions
3 Pole AC Disconnect CAM Switch
Nominal Voltage
400VAC @ 50/60Hz
Rated Impulse Voltage
6kV
Nominal Current Range AC
25 Amp @400VAC
Rated Insulation Voltage
690VAC
Humidity
10-85%
Approvals
CE
Standards
IEC 60947-1,-3, IEC 60204, IP20 (IP40 Installed)
Weight
200g
Enclosure Material
UL94V0
Factory Pack Qty
1
TRENT(Fastron) Head Office
Australia
Datasheet
Datasheet
TGLW30-4D100, 4 Pole Rotary/CAM Switch RED, 100 Amp 400VAC, Plastic, Direct Type, IEC60947-5-1
Rotary CAM Switches are used to Isolate or Switch under load. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation by the user.
Features :
400VAC in various Ratings
4 Pole 2 Postion
64mm x 64mm Cutout
Standards :
IP40 Front, IP20 Terminals
IEC 60947-1,-3
IEC 60204
Specification
TRENT Part Number
TGLW30-4D100
Functions
4 Pole AC Disconnect CAM Switch
Nominal Voltage
400VAC @ 50/60Hz
Rated Impulse Voltage
6kV
Nominal Current Range AC
100 Amp @400VAC
Rated Insulation Voltage
690VAC
Humidity
10-85%
Approvals
CE
Standards
IEC 60947-1,-3, IEC 60204, IP20 (IP40 Installed)
Weight
470g
Enclosure Material
UL94V0
Factory Pack Qty
1
TRENT(Fastron) Head Office
Australia
Datasheet
Datasheet
TGLW30-3R100, 3 Pole Rotary/CAM Switch RED, 100 Amp 400VAC, Plastic, Direct Type, IEC60947-5-1
Rotary CAM Switches are used to Isolate or Switch under load. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation by the user.
Features :
400VAC in various Ratings
3 Pole 2 Postion
64mm x 64mm Cutout
Standards :
IP40 Front, IP20 Terminals
IEC 60947-1,-3
IEC 60204
Specification
TRENT Part Number
TGLW30-3R100
Functions
3 Pole AC Disconnect CAM Switch
Nominal Voltage
400VAC @ 50/60Hz
Rated Impulse Voltage
6kV
Nominal Current Range AC
100 Amp @400VAC
Rated Insulation Voltage
690VAC
Humidity
10-85%
Approvals
CE
Standards
IEC 60947-1,-3, IEC 60204, IP20 (IP40 Installed)
Weight
470g
Enclosure Material
UL94V0
Factory Pack Qty
1
TRENT(Fastron) Head Office
Australia
Datasheet
Datasheet
TGLW30-3D63, 3 Pole Rotary/CAM Switch RED, 63 Amp 400VAC, Plastic, Direct Type, IEC60947-5-1
Rotary CAM Switches are used to Isolate or Switch under load. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation by the user.
Features :
400VAC in various Ratings
3 Pole 2 Position
64mm x 64mm Cutout
Standards :
IP40 Front, IP20 Terminals
IEC 60947-1,-3
IEC 60204
Specification
TRENT Part Number
TGLW30-3D63
Functions
3 Pole AC Disconnect CAM Switch
Nominal Voltage
400VAC @ 50/60Hz
Rated Impulse Voltage
6kV
Nominal Current Range AC
63 Amp @400VAC
Rated Insulation Voltage
690VAC
Humidity
10-85%
Approvals
CE
Standards
IEC 60947-1,-3, IEC 60204, IP20 (IP40 Installed)
Weight
265g
Enclosure Material
UL94V0
Factory Pack Qty
1
TRENT(Fastron) Head Office
Australia
Datasheet
Datasheet
Trent F170M1312 Series 690V Semiconductor I^2t (aR) Fuse Square Body DIN 43 653 Style, 32 Amp, 690VAC, Panel Mount 200kA, Size 000 (78mm Hole Centers)
Features
Square Body DIN 43 653
Wide Range of I^2t
Ratings up to 400 Amp
Busbar or Standoff Mounting
IEC Standard 60269.1 AND 4
690 V Voltage Rating complying with IEC 33
Applications
Protection of High Powered Semiconductors according to I??t
Short Circuit Protection
DC or AC Motor Protection
Battery Fuse
Specification
Trent Part Number
F170M1312
Fuse Type
I^2t AR Class
Nominal Voltage
690VAC @ 50Hz
I??t Rating (660V)
270 A^2/s
Nominal Current (RMS DC)
32 Amp
Tested Breaking Capacity
200kA @ 690VAC
Dimensions
40 x 100 x 20mm (Size 000)
Hole Centers
78mm
Mounting Style
Busbar or Panel Mount with Standoff
Operating Temperature Range
-40DegC / 125DegC
Watt Loss
24W
Termination Style
M8
Unit Weight
134g
Factory Pack Qty
10
Datasheet
Product Datasheet
TRENT TG-63H 1P/32/C/10kA, 1 Pole Miniature Circuit Breaker C Curve 32 Amp, 10kA, 400VAC
Miniature Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
< 50mS Trip Delay Time
1 Pole Disconnect
10kA Short Circuit Rating
Suitable for Isolation
Customised versions available
Type B, C, D Curve available
Standards :
IEC/EN 60898
IEC/EN/AS60898-1
IP20 (IP40 Installed) IEC 61008
CE,CB
Specification
TRENT Part Number
TG-63H 1P/32/C/10kA
Functions
1 Pole MCB - C Curve
Nominal Voltage
400VAC @ 50/60Hz
Nominal Current Range
32 Amps RMS
Trip Delay Time
< 50ms
Rated Impulse Voltage
6kV
Operating Temperature
-25 to 40 Deg C
Mechanical Operations
10,000 Ops
Insulation Voltage
690V
Breaking Capacity
10kA
Approvals
CE,CB
Standards
IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ;
Weight
350g
Enclosure Material
UL94
Factory Pack Qty
1
TRENT Headquarters
Australia
Datasheet
Product Datasheet
Trent F170M1321 Series 690V Semiconductor I^2t (aR) Fuse Panel Mount Style, 250 Amp, 690VAC, Panel Mount 200kA, Size 000 (78mm Hole Centers)
Features
Square Body DIN 43 653
Wide Range of I^2t
Ratings up to 400 Amp
Busbar or Standoff Mounting
IEC Standard 60269.1 AND 4
690 V Voltage Rating complying with IEC 33
Applications
Protection of High Powered Semiconductors according to I??t
Short Circuit Protection
DC or AC Motor I^2t Protection
Battery Fuse
Specification
Trent Part Number
F170M1321
Fuse Type
I^2t AR Class
Nominal Voltage
690VAC @ 50Hz
I??t Rating (660V)
51500 A^2/s
Nominal Current (RMS DC)
250 Amp
Tested Breaking Capacity
200kA @ 690VAC
Dimensions
40 x 100 x 20mm (Size 000)
Hole Centers
78mm
Mounting Style
Busbar or Panel Mount with Standoff
Operating Temperature Range
-40DegC / 125DegC
Watt Loss
42W
Termination Style
M8
Unit Weight
134g
Factory Pack Qty
10
Datasheet
Product Datasheet
Trent F170M1311 Series 690V Semiconductor I^2t (aR) Fuse Square Body DIN 43 653 Style, 25 Amp, 690VAC, Panel Mount 200kA, Size 000 (78mm Hole Centers)
Features
Square Body DIN 43 653
Wide Range of I^2t
Ratings up to 400 Amp
Busbar or Standoff Mounting
IEC Standard 60269.1 AND 4
690 V Voltage Rating complying with IEC 33
Applications
Protection of High Powered Semiconductors according to I??t
Short Circuit Protection
DC or AC Motor Protection
Battery Fuse
Specification
Trent Part Number
F170M1311
Fuse Type
I^2t AR Class
Nominal Voltage
690VAC @ 50Hz
I??t Rating (660V)
130 A^2/s
Nominal Current (RMS DC)
25 Amp
Tested Breaking Capacity
200kA @ 690VAC
Dimensions
40 x 100 x 20mm (Size 000)
Hole Centers
78mm
Mounting Style
Busbar or Panel Mount with Standoff
Operating Temperature Range
-40DegC / 125DegC
Watt Loss
24W
Termination Style
M8
Unit Weight
134g
Factory Pack Qty
10
Datasheet
Product Datasheet
Trent F170M1310 Series 690V Semiconductor I^2t (aR) Fuse Square Body DIN 43 653 Style, 20 Amp, 690VAC, Panel Mount 200kA, Size 000 (78mm Hole Centers)
Features
Square Body DIN 43 653
Wide Range of I^2t
Ratings up to 400 Amp
Busbar or Standoff Mounting
IEC Standard 60269.1 AND 4
690 V Voltage Rating complying with IEC 33
Applications
Protection of High Powered Semiconductors according to I??t
Short Circuit Protection
DC or AC Motor Protection
Battery Fuse
Specification
Trent Part Number
F170M1310
Fuse Type
I^2t AR Class
Nominal Voltage
690VAC @ 50Hz
I??t Rating (660V)
78 A^2/s
Nominal Current (RMS DC)
20 Amp
Tested Breaking Capacity
200kA @ 690VAC
Dimensions
40 x 100 x 20mm (Size 000)
Hole Centers
78mm
Mounting Style
Busbar or Panel Mount with Standoff
Operating Temperature Range
-40DegC / 125DegC
Watt Loss
24W
Termination Style
M8
Unit Weight
134g
Factory Pack Qty
10
Datasheet
Product Datasheet
Trent F170M1322 Series 690V Semiconductor I^2t (aR) Fuse Panel Mount Style, 315 Amp, 690VAC, Panel Mount 200kA, Size 000 (78mm Hole Centers)
Features
Square Body DIN 43 653
Wide Range of I^2t
Ratings up to 400 Amp
Busbar or Standoff Mounting
IEC Standard 60269.1 AND 4
690 V Voltage Rating complying with IEC 33
Applications
Protection of High Powered Semiconductors according to I??t
Short Circuit Protection
DC or AC Motor I^2t Protection
Battery Fuse
Specification
Trent Part Number
F170M1322
Fuse Type
I^2t AR Class
Nominal Voltage
690VAC @ 50Hz
I??t Rating (660V)
80500 A^2/s
Nominal Current (RMS DC)
315 Amp
Tested Breaking Capacity
200kA @ 690VAC
Dimensions
40 x 100 x 20mm (Size 000)
Hole Centers
78mm
Mounting Style
Busbar or Panel Mount with Standoff
Operating Temperature Range
-40DegC / 125DegC
Watt Loss
52W
Termination Style
M8
Unit Weight
134g
Factory Pack Qty
10
Datasheet
Product Datasheet