Trent FGM6DC-630 500A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 500 Amp, 1500VDC
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
2 Pole Disconnect
20kA Short Circuit Rating @1500VDC
Suitable for DC Power Systems Including Solar and Battery
Standards :
IEC/EN 60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
FGM6DC-630 500A
Functions
2 Pole DC MCCB
Nominal Voltage
1500VDC
Nominal Current Range
500 Amps @ 40 Deg C
Trip Delay Time
< 50ms
Rated Impulse Voltage
12kV
Operating Temperature
-35 to 70 Deg C
Electrical Operations
1,000 Ops
Insulation Voltage
1500V
Short Circuit Current Ics=Icu (Ics/Icu)
20kA
Approvals
TUV, CE
Standards
GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)
Dimensions
W98xH310xD130mm
Weight
6.6kg
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Crouzet 88975111, Millenium EVO Ethernet, Smart Relay with Display, 24 I/O, 24VDC, 8 Configurable Analogue/Digital Inputs, 4 x High Speed 15kHz Inputs, 4 x Std Digital Inputs, 2 x 6 Amp Relay, 6 x 8 Amp Relay
Up to 44 I/Os - 16 DI (4 HighSpeed / 8 AI) - 8 DO
Wireless programming & Control with bluetooth Interface and Crouzet Virtual Display
Modbus RTU Network (Slave)
Local datalog management
Up to 1000 programing blocks with intuitive Crouzet Soft to go from simple to complex applications
HMI Screens Available
Specification
Crouzet Part Number
88975111 (Millenium EVO)
Analogue Inputs
0 - 10VDC, 0-V Power Supply or Voltmeter
Digital Inputs
24VDC @ 2.1mA (8 Standard and 4 High Speed)
Digital Outputs
Relay, 24VDC, 250VAC @ 100mA minimum (2 x 6 Amp, 6 x 8 Amp)
PWM SSR Output
None
Expandable
Yes
Comms
Ethernet. (RS485, Bluetooth). Standard and Wifi versions available
LCD Display
Yes
Mounting Style
DIN Rail Mount (124.6mm)
Supply Voltage Range
24VAC (21.6 - 28.8VAC)
Termination Style
Screw
Weight
350g
Environmental
Reach, RoHS, Halogen free 1272/2008/CE
Certification
CE, cULus Listed
Factory Pack Qty
1
Over Voltage Category
3 in accordance with IEC/EN 60664-1
Pollution Degree
2 in accordance with IEC/EN 61131-2
Protection rating
IP40 (Front), IP20 (Rear)
Mechanical Resistance
Immunity to vibrations IEC/EN 60068-2-6, test Fc
Immunity to shock IEC/EN 60068-2-27, test Ea
Resistance to HF Interference
Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12
Conducted and radiated emissions
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Operating Temperature
-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22
Datasheet
Product Datasheet
Launching Note
Software
Crouzet Touch Soft V6.00.02.173
Software M3-soft-AC9-V3.1.2.0_ML
Remote Control Software CVD_PC_V2_3_01_02
Crouzet Soft EVO EM4 1.12.01.14
Trent FGM6DC-2PL-320 80A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 80 Amp, 1000VDC
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
2 Pole Disconnect
20kA Short Circuit Rating @1000VDC
Suitable for DC Power Systems Including Solar and Battery
Standards :
IEC/EN 60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
FGM6DC-2PL-320 80A
Functions
2 Pole DC MCCB
Nominal Voltage
1000VDC
Nominal Current Range
80 Amps
Trip Delay Time
< 50ms
Rated Impulse Voltage
12kV
Operating Temperature
-35 to 70 Deg C
Electrical Operations
5,000 Ops
Insulation Voltage
1500V
Short Circuit Current Ics=Icu (Ics/Icu)
20kA
Approvals
CE
Standards
GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)
Weight
2.2kg
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
CE Declaration
Techsem MTC1200-18-412F3D, Dual Thyristor Module, 1200 Amp, 1800V
Features
Thyristor for line frequency
Pressure Contact Technology
Electrically insulated base plate
Industrial standard package
Long-term stability
2500V Isolation
77mm Base Width
Applications
Power Converter
Line rectifying 50/60 Hz
Deep Cycle Applications
Controlled Rectifiers
Softstart AC motor control
AC power control
Lighting and temperature control
Specification
Techsem Part Number
MTC1200-18-412F3D
Vrrm
1800V
Diode Configuration
Dual Thyristor Module
IF(av) @ 85 Deg C
1200 Amp
Package Size
W:77mm L:180mm D:78mm
Itsm
34 kA
VF(to)
0.8V
Tj(max)
125°C
rF
0.09mΩ
I(gt) @ 25 Deg C
200mA
Terminals
M12 Screw
Hole Centres
132mm x 58mm(M6)
Gate Terminals
Spade (A 2.8 - 0.8 DIN 46244)
R th(j-c)
0.031°C/W
R th(c-h)
0.020°C/W
Weight
3500g
Mounting Torque
8 Nm (12 Nm Terminals)
Factory Pack Qty
2
Certification
UL Listed, ROHS
Techsem Headquarters
China
Datasheet
Product Datasheet
Techsem MTC2000-18-436F3-R, Dual Thyristor Module, 2000 Amp, 1800V
Features
Thyristor for line frequency
Pressure Contact Technology
Electrically insulated base plate
Industrial standard package
Long-term stability
2500V Isolation
77mm Base Width
Applications
Power Converter
Line rectifying 50/60 Hz
Deep Cycle Applications
Controlled Rectifiers
Softstart AC motor control
AC power control
Lighting and temperature control
Specification
Techsem Part Number
MTC2000-18-436F3-R
Vrrm
1800V
Diode Configuration
Dual Thyristor Module
IF(av) @ 85 Deg C
2000 Amp
Package Size
W:100mm L:230mm D:92mm
Itsm
54.7 kA (VR=0, t=10ms half sine)
VF(to)
0.8V
Tj(max)
125°C
rF
0.14mΩ
I(gt) @ 25 Deg C
200mA
Terminals
M12 Screw
Hole Centres
132mm x 58mm(M6)
Gate Terminals
Spade (A 2.8 - 0.8 DIN 46244)
R th(j-c)
0.025°C/W
R th(c-h)
0.018°C/W
Weight
3500g
Mounting Torque
8 Nm (12 Nm Terminals)
Factory Pack Qty
2
Certification
UL Listed, ROHS
Techsem Headquarters
China
Datasheet
Product Datasheet
Trent FGM6DC-2PL-630 630A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 500 Amp, 1000VDC
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
2 Pole Disconnect
20kA Short Circuit Rating @1000VDC
Suitable for DC Power Systems Including Solar and Battery
Standards :
IEC/EN 60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
FGM6DC-2PL-630 630A
Functions
2 Pole DC MCCB
Nominal Voltage
1000VDC
Nominal Current Range
630 Amps
Trip Delay Time
< 50ms
Rated Impulse Voltage
12kV
Operating Temperature
-35 to 70 Deg C
Electrical Operations
5,000 Ops
Insulation Voltage
1500V
Short Circuit Current Ics=Icu (Ics/Icu)
20kA
Approvals
CE
Standards
GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)
Weight
5.7kg
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
CE Declaration
Taisuo TMD-N7611 PID Controller, 100-240VAC with 1 Alarm, RS485, E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 72x72mm, SCR Trigger Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Specification
Taisuo Part Number
TMD-N7611
Control Output
SCR/AC Switch Trigger (Single Phase)
Input
Multirange Type,E,J,N,T,S,R,B, Pt100, Cu50/(Optional)Linear Current 4(0)-20mA/(Optional)Linear Voltage 0-10(5)V
Option 1
1 Alarm
Mounting Style
72x72mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
250ms
Weight
150-270g
Factory Pack Qty
1
Datasheet
FC5 Datasheet and User Manual
Fastron TTH-33-SA3-3, Temperature and Humidity Sensor and Transmitter,500 x 6mm w/3M Cable
2 x 4-20mA Output 2 Wire
Humidity Measurement for RH 0 to 100 %
Long Term Stability <2% RH per year
Temp Measurement for 0 to 100 Deg C Max
500 x 6mm with 3M Cable
20 Second Response Time
12-30VDC Supply 150mA max
Thin Film Capacitor and Pt100 Temp Sensing Elements
Suitable replacement for Mecatherm T211-XH-954
Specification
Fastron Part Number
TTH-33-SA3-3
Sensor Type
RTD (Temperature) & Thin Film Capacitor (Humidity)
No of Wires
2
Shaft Length
500mm
Shaft Thickness
6mm
Approvals
CE, ROHS
Cable length
1 Meter
Temperature Range
0 to 100 Deg C
Mounting Style
Through Hole
Weight
45g
Factory Pack Qty
1
Datasheet
Datasheet
Installation Guide
Wiring Diagram
Magnelab DVT-1000-420, DC Voltage Transducer, Din Rail Mount, 10-1000VDC, 4-20mA output, 15-48VDC Supply Voltage, 10mS Response
10mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Magnelab Part Number
DVT-1000-420
Control Output
4-20mA
Input
10 - 1000VDC
Measurement Range
120%
Overload
150% Continuous
Operating Temperature
-30 - 70°C
Operating Voltage
15 - 48VDC
Voltage Isolation (1 min)
4.5kV
Accuracy
1%
Response Time
10mS
Termination Style
Screw
Mounting Style
DIN Rail Mount
Safety
UL508C, CSA C22.2
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Crouzet 88970534, Essential Series CT107, 7" HMI Touch Screen, 24VDC, RS495 Modbus RTU
TFT-LCD resistive touch screen
Fan less cooling system
32 bit 600 Mhz or 1 Ghz Cortex-A8 processor
Built-in RTC
Direct communication with M3 programming port
Modbus RS485 protocol (drivers for M3, EVO and em4)
Modbus TCP/IP protocol (drivers for M3, EVO and em4)
Integrated VNC server
Additional functions provided by Crouzet Touch programming software (e-mails,recipe database, enhanced security…)
CE mark, cULus listed
Specification
Crouzet Part Number
88970534 (CT107)
Function
Human Machine Interface (Touch Screen)
Nominal Voltage
24VDC (19.2 - 28.8VDC) @ 500mA
Display Size
7"
Resolution
800 x 480
Brightness
300 cd/m²
Storage Memory
128MByte
RAM Memory
128MByte
USB
Host USB 2.0
Ethernet
N/A
Port RS232
COM1 Male
Port RS485
COM1 2/4 wires Male, COM3 2 wires Male
Voltage Resistance
500VAC (1 Min)
Dimensions
200.4 x 146.5 x 34 mm / 7.89 x 5.77 x 1.34”
Real Time Clock
5 Years with CR2032 Battery
Termination Style
Screw
Weight
520g
Certification
CE
Factory Pack Qty
1
Over Voltage Category
3 in accordance with IEC/EN 60664-1
Pollution Degree
2 in accordance with IEC/EN 61131-2
Protection rating
IP40 (Front), IP20 (Rear)
Mechanical Resistance
Immunity to vibrations IEC/EN 60068-2-6, test Fc
Immunity to shock IEC/EN 60068-2-27, test Ea
Resistance to HF Interference
Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12
Conducted and radiated emissions
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Operating Temperature
-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22
Datasheet
HMI Touch Datasheet
HMI Touch Brochure
Software
Crouzet Touch Soft V6.00.02.173
Software M3-soft-AC9-V3.1.2.0_ML
Remote Control Software CVD_PC_V2_3_01_02
Crouzet Soft EVO EM4 1.12.01.14
Compatibility
Built in Communications driver compatible with Millenium 3, Millenium EVO, and EM4 PLC's. See our PLC Section for Pricing and Specification
Advanced Energy THyro-Touch Display, TFT Touch Screen for Thyro PX Series SCR Controllers
Features
Switchable display to bar chart, line chart, actual values, or data logger
Integrated SD card to load or save data
Process data recorder of up to 6 parameters as well as status messages
Analysis via Thyro-Touch tool on PC
EasyStart feature for easy commissioning of Thyro-PX with basic settings
Languages: German, English (additional options on request)
UL and CE Approved
Suitael for Thyro PX
Datasheet
Product Datasheet
User Manual
User Guide
Blog for initial communication setup issue
Setting Up Comms on Thyro A Series Controllers
Thyro Touch Software and Touch Display User Guide
Anybus Device Ethernet IP Setup Guide