Search results for "tg@tetherzon$*오다집수수료코인이체구입"
-
TCD-H-1-K HEATING Temp Controller, 48x96mm 230VAC, C/O Relay output, Type K Input. Encoder Control, Digital Display, 0-999 Deg C
TCD-H-1-K HEATING Temp Controller, 48x96mm 230VAC, C/O Relay output, Type K Input. Encoder Control,amp; Digital Display, 0-999 Deg C Pushbutton Encoder Setpoint 3-digit display (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) Input signals can be converted to insulated ON/OFF Relay, output, Optional cooling or time proprtional versions output available Each unit needs just 75 mm depth panel space Specification Fastron Part Number TCD-H-1-K Control Output Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4) Input Type K Thermocouple Control Mode Heating ON/OFF Control Control Range 0- 999 Deg C Mounting Style 48x96mm Panel Mount Supply Voltage 230VAC Termination Style Screw Sampling Time 50ms Weight 270g Factory Pack Qty 1 Datasheet TCD/TCR/FC5 Datasheet TCD/TCR User Manual
$105.00
$123.90 inclGST -
TCD-L-2-K COOLING Temp Controller, 96x96mm 230VAC, C/O Relay output, Type K Input. Encoder Control, Digital Display, 0-999 Deg C
TCD-L-2-K COOLING Temp Controller, 96x96mm 230VAC, C/O Relay output, Type K Input. Encoder Control,amp; Digital Display, 0-999 Deg C Pushbutton Encoder Setpoint 3-digit display (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) Input signals can be converted to insulated ON/OFF Relay, output, Optional cooling or time proprtional versions output available Each unit needs just 75 mm depth panel space Specification Fastron Part Number TCD-L-2-K Control Output Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4) Input Type K Thermocouple Control Mode Cooling ON/OFF Control Control Range 0- 999 Deg C Mounting Style 96x96mm Panel Mount Supply Voltage 230VAC Termination Style Screw Sampling Time 50ms Weight 270g Factory Pack Qty 1 Datasheet TCD/TCR/FC5 Datasheet TCD/TCR User Manual
$105.00
$123.90 inclGST -
SCT-F36-100, 0.333V, 100Amp Measurement, Class 1 Split Core CT's, 35mm Aperture
Fastron Electronics SCT-F36-100, 0.333V, 100Amp measurement Split Core CT's Class 1, 36mm Aperture Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F36-100 Technology Split Core AC Current Transformer Ratio 100/0.333V Aperture Size ø 35 mm VA Rating N/A Accuracy Class Class 1 Output 0.333V (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 100Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$66.50
$78.47 inclGST -
SCT-F16-100-5A, 100/5Amp Measurement, Class 1 Split Core CT's
Fastron Electronics SCT-F16-100-5A, 5 Amp Output, 100Amp measurement Split Core Current Transformer Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.5M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F16-100-5A Technology Split Core AC Current Transformer Ratio 100/5A Aperture Size ø 15 mm VA Rating 1VA Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 100Amp x 1.2 Termination Style 0.5M Flying leads Unit Weight 100g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide
$45.00
$53.10 inclGST -
SDM630MCT-3L-MID, Tri 3 Phase DIN Rail Mount kWh Meter with Easyclick, 3 x 3 Phase or 9 x Single Phase, 240VAC aux, Class 1, 100mA RJ12 CT Connect, w/RS485 Modbus RTU Comms
Eastron SDM630MCT-3L, Tri 3 Phase DIN Rail Mount kWh Meter with Easyclick, 3 x 3 Phase or 9 x Single Phase, 240VAC aux, Class 1, 100mA RJ12 CT Connect, w/RS485 Modbus RTU Comms 100mA RJ12 CT 3 x 3 Phase Connect 100mA RJ12 9 x Single Phase RJ12 CT with adapter RS 485 communication up to 38,400 bit/s as standard True RMS values of currents and voltages Easyclick CT system reduces installation costs Dual Metering System Reduces Cost and saves space The meter is intended for measuring, and monitoring 2 x three phase or 6 x single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals. Features : System Accuracy Class B/Class1 Measurement of Active and Reactive Power Modbus RTU communication up to 38,400 bit/s communication Graphic LCD with illumination Specification Eastron Europe Part Number SDM630MCT-3L Functions Tri Three Phase Energy Meter/ 9 x Single Phase Energy Meter Supply Voltage 230V L-N +/-15% < 5VA Nominal Measurement Range 415V L-L 230V L-N, 1/5 Amp +/-15% Maximum Measurement Range 480V L-L 230V L-N, 1/5 Amp Nominal CT Current Input 100mA via RJ12 Easyclick CT's Pulse Output N/A Tariff Input N/A System Accuracy Class 1 (I,U,F,kW,kWh) Class 2 (Reactive) Mounting Din Rail Real Time Clock 1min/month (30ppm) Internal Memory N/A Dimensions 72mm x 100mm x 66mm (4 modules wide) Isolation 4kV RS485 2400-38400 b/s (400ms Response Time) Weight 600g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Safety IP51(Indoor) Enclosure Material Noryl with fire protection to UL94-V-O. Self extinguishing Enclosure Size DIN 42880 4 Modules Operating Temperature -20 →+70 °C Documents Product Datasheet User Manual Modbus Protocol Suitable RJ12 CT's Three Phase J12 Connected CT's Split Core Single Phase CT's for RJ12 Connected Meters Modbus Utility EEM Meter Setting Software Utility
$409.00
$482.62 inclGST -
SCT-F50-800-5A, 5 Amp, 800Amp measurement Split Core CT's
Fastron Electronics SCT-F50-800-5A, 5 Amp, 800Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F50-800-5A Technology Split Core AC Current Transformer Ratio 800/5 Amp Aperture Size ø 50 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 800Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 1000g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$110.55
$130.45 inclGST -
TCD-M-1-PT HEATING Temp Controller, 72x72mm 230VAC, C/O Relay output, PT100 RTD Input. Encoder Control, Digital Display, 0-999 Deg C
TCD-M-1-PT HEATING Temp Controller, 72x72mm 230VAC, C/O Relay output, PT100 RTD Input. Encoder Control,amp; Digital Display, 0-999 Deg C Pushbutton Encoder Setpoint 3-digit display (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) Input signals can be converted to insulated ON/OFF Relay, output, Optional cooling or time proprtional versions output available Each unit needs just 75 mm depth panel space Specification Fastron Part Number TCD-M-1-PT Control Output Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4) Input Pt100 RTD Control Mode Heating ON/OFF Control Control Range 0- 999 Deg C Mounting Style 72x72mm Panel Mount Supply Voltage 230VAC Termination Style Screw Sampling Time 50ms Weight 270g Factory Pack Qty 1 Datasheet TCD/TCR/FC5 Datasheet TCD/TCR User Manual
$105.00
$123.90 inclGST -
SCT-F36-600-5A, 5 Amp, 600Amp Measurement, Class 1 Split Core CT's
Fastron Electronics SCT-F36-600-5A, 5 Amp, 600Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F36-600-5A Technology Split Core AC Current Transformer Ratio 600/5 Amp Aperture Size ø 35 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 600Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$66.50
$78.47 inclGST -
SCT-F36-630-5A, 5 Amp, 630Amp Measurement, Class 1 Split Core CT's
Fastron Electronics SCT-F36-630-5A, 5 Amp, 630Amp Measurement, Class 1 Split Core CT's Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F36-630-5A Technology Split Core AC Current Transformer Ratio 630/5 Amp Aperture Size ø 35 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 630Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$66.50
$78.47 inclGST -
TCD-M-2-K COOLING Temp Controller, 72x72mm 230VAC, C/O Relay output, Type K Input. Encoder Control, Digital Display, 0-999 Deg C
TCD-M-2-K COOLING Temp Controller, 72x72mm 230VAC, C/O Relay output, Type K Input. Encoder Control,amp; Digital Display, 0-999 Deg C Pushbutton Encoder Setpoint 3-digit display (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) Input signals can be converted to insulated ON/OFF Relay, output, Optional cooling or time proprtional versions output available Each unit needs just 75 mm depth panel space Specification Fastron Part Number TCD-M-2-K Control Output Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4) Input Type K Thermocouple Control Mode Cooling ON/OFF Control Control Range 0- 999 Deg C Mounting Style 72x72mm Panel Mount Supply Voltage 230VAC Termination Style Screw Sampling Time 50ms Weight 270g Factory Pack Qty 1 Datasheet TCD/TCR/FC5 Datasheet TCD/TCR User Manual
$105.00
$123.90 inclGST -
FP125125P, 1250/5 Amp Split Core CT, Class 0.5, 7.5VA, 80 x 120mm Aperture, Dimensions 145 x 37 x 200mm
FP125125P, 1250/5 Amp Split Core CT, Class 0.5. 7.5VA Series Clip On Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Electronics Part Number FP125125P Technology Split Core AC Clip On Current Transformer Ratio 1250/5 Aperture Size 85 x 120mm VA Rating 7.5VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 1250Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$137.00
$161.66 inclGST -
GTD-DAO(0-1)-D-11, AC Current Transducer, 0-1 Amp AC input, 22-60VAC/DC aux, Dual 4-20mA Average RMS outputs
Free Aus Post Shipping for $300 SpendFastron Electronics GTD-DAO(0-1)-D-11, Signal Conditioner/Current Transducer, 0-1 Amp AC input, 22-60VAC/DC aux, Dual 4-20mA Average RMS outputs Adjustable Zero and Span Setting 250mS Response Time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space Specification Fastron Electronics Part Number GTD-DAO(0-1)-A-11 Conditioned Output 2 x 4-20mA (Average RMS) Input 0 -1 Amp RMS Over Range x 1.5 Operating Temperature 0 - 60°C Load Voltage 22-60VAC/DC Span Adjustment Range +/-10% Zero Adjustment Range +/-5% Termination Style Screw Mounting Style DIN Rail Mount Case Material PC - UL 94 V0 Weight 170g Factory Pack Qty 1 Datasheet Product Datasheet
Free Aus Post Shipping for $300 Spend$249.00
$293.82 inclGST