Search results for "tg@tetherzon!*이더리움전송롯데상품권코인구매"
-
FRTD Series Pt100 RTD MIMS Class A, Standard Sizes and Lengths, Braided SS/Teflon Tail, 304 Stainless Steel Sheath
Fastron FRTD Series Pt100 Resistance Temperature Detector (RTD)Mineral Insulated 304 Stainless Steel Sheath, Braided SS/Teflon Screeend Tail, Various Dimensions Class A Accuracy CE, ANSI, ROHS Approved Teflon Screened SS Braided Cable (3M standard) Low Long Term Drift Rated for -50 to 350 Deg C Max (300 Deg C for L shaped style) Spring Cable Connection 3/5mm Sheath Diameter or custom 50-500mm Sheath Length or custom MIMS Recommended to use BSP Fitting for mounting Specification Fastron Part Number FRTD Series Sensor Type Pt100 Resistance Temperature Detector No of Wires 2 Probe Length 50-100mm or custom Sheath Thickness 3/5mm or custom Sheath Material SS 304 Stainless Steel Accuracy Class A Approvals CE, ANSI, ROHS Cable length 3 Meters (Standard) or custom Cable Type Teflon/Braided Stainless Steel Temperature Range -50 to 350 Deg C Special Feature Spring Cable Strain Relief Mounting Style BSP Bayonet or Flange Fitting Recommended Weight 300-500g Factory Pack Qty 1 Datasheet RTD Standard Datasheet
$67.00 - $85.00
-
F923 AC Series Current Transducer with Adjustable High and Low Solid State Relay Alarm
F923 Series AC Current Transducer with Process Outputs & High and Low Sold State Alarm Features Isolated measurement of AC currents using internal Hall effect transducer. Incorporates an integrated input level display and power supply. Wide measurement range available Choice of standard outputs Wide range isolated DC input supply DIN Rail mounting Signal Conditioned AC measurement output On board bar graph display User adjustable zero offset and span controls Zero insertion loss in current measurement path Earth leakage via differential Ipn for nominal Input ‘01’ Applications Process control Transportation Petrochemical Industrial Earth Leakage Energy Monitoring/Measurement Automation Delivery Delivery in 3-5 days for small qty. Otherwise 4-6 weeks Specification Oztherm Part Number F923-X-XX-AC-XX Functions Single Phase AC Current Transducer Supply Voltage 9-36VDC Nominal Measurement Range 0-8 Amp (Sensor dependant) Maximum Measurement Range 8 Amp Alarm C/O Relay 2Amp @ 40VDC, 2Amp @ 60VAC Response Time 250mS Accuracy @ 25 Deg C Class 1 Bandwidth DC - 1kHz linearity < 0.15% Isolation 2.5kV Comms N/A Weight 250g Enclosure Size 79 x 60 x 85mm Factory Pack Qty 1 EU Directives N/A Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material Polyamide non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP40 Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet
$552.00 - $595.00
-
F921 DC Series Current Transducer, 100mA to 400 Amp Range with Adjustable High and Low Solid State Alarm
F921 Series DC Current Transducer with Process Outputs & High and Low Sold State Alarm Features Isolated measurement of DC currents using a Hall effect transducer with external aperture. Incorporates an integrated input level display and power supply. Wide measurement range available Choice of standard outputs Wide range isolated DC input supply DIN Rail mounting Signal Conditioned DC measurement output On board bar graph display User adjustable zero offset and span controls Zero insertion loss in current measurement path Earth leakage via differential Ipn for nominal Input ‘01’ Applications Process control Transportation Petrochemical Industrial Earth Leakage Energy Monitoring/Measurement Automation Delivery Delivery in 3-5 days for small qty. Otherwise 4-6 weeks Specification Oztherm Part Number F921-X-XX-DC-XX-XX Functions Single Phase AC Current Transducer Supply Voltage 9-36VDC Nominal Measurement Range 0-400 Amp (Sensor dependant) Maximum Measurement Range 2500 Amp with External Sensor Alarm C/O Relay 2Amp @ 40VDC, 2Amp @ 60VAC Response Time 250mS Accuracy @ 25 Deg C Class 1 Bandwidth DC - 1kHz linearity < 0.15% Isolation 2.5kV Comms N/A Weight 250g Enclosure Size 79 x 60 x 85mm Factory Pack Qty 1 EU Directives N/A Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material Polyamide non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP40 Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet
$595.00
$702.10 inclGST -
F921 AC Series Current Transducer, 100mA to 400 Amp Range with Adjustable High and Low C/O Relay Alarm
F921 Series AC Current Transducer with Process Outputs & High and Low C/O Alarm Features Isolated measurement of AC currents using internal Hall effect transducer. Incorporates an integrated input level display and power supply. Wide measurement range available Choice of standard outputs Wide range isolated DC input supply DIN Rail mounting Signal Conditioned AC measurement output On board bar graph display User adjustable zero offset and span controls Zero insertion loss in current measurement path Earth leakage via differential Ipn for nominal Input ‘01’ Applications Process control Transportation Petrochemical Industrial Earth Leakage Energy Monitoring/Measurement Automation Delivery Delivery in 3-5 days for small qty. Otherwise 4-6 weeks Specification Oztherm Part Number F921-X-XX-AC-XX Functions Single Phase AC Current Transducer Supply Voltage 9-36VDC Nominal Measurement Range 0-400 Amp (Sensor dependant) Maximum Measurement Range 0-2500 Amp (with HAX 2500-S external Sensor) Alarm C/O Relay 4Amp @ 30VDC, 0.5Amp @ 150VAC Response Time 250mS Accuracy @ 25 Deg C Class 1 Bandwidth DC - 1kHz linearity < 0.15% Isolation 2.5kV Comms N/A Weight 250g Enclosure Size 79 x 60 x 85mm Factory Pack Qty 1 EU Directives N/A Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material Polyamide non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP40 Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet
$595.00
$702.10 inclGST -
FTCK-PIPE-3000, Type K Clamp Style Thermocouple for Pipes, Various Clamp Sizes, 3000mm 2 Wire Braided SS/Fibreglass/Teflon Wire, CE, ANSI, ROHS Approved
Free Aus Post Shipping for $300 SpendFastron FTCK-PIPE-3000, Type K Clamp Style Thermocouple for Pipes, Various Clamp Sizes, 3000mm 2 Wire Braided SS/Fibreglass/Teflon Wire, CE, ANSI, ROHS Approved Features Class A Accuracy Pipe Clamp Style Sensor Low Long Term Drift Rated for -20 to 370 Deg C Max 3000mm Tail Length Available in custom lengths Fibreglass Sheath Specification Fastron Part Number FTCK-PIPE-3000 Sensor Type Type K Thermocouple Ungrounded No of Wires 2 TailLength 3000mm or custom Clamp Size 7/32 -> 5/8", 3/8 -> 1/2", 3/8 -> 5/8", 1/2 -> 5/8", 5/8 -> 3/4", 3/4 -> 1", 1 1/4 -> 1 1/2", 1 1/4 -> 1 3/4", 1 1/2 -> 2", 1 3/4 -> 2 1/4", 2 1/16 -> 3", 2 5/16 -> 3 1/4", 3 -> 3 1/4", 3 - 1/4", 3 -> 3 1/2", 4 -> 4 1/2", 4 1/6 -> 5", 4 5/8 -> 5 1/2", 5 1/8 -> 6", 5 7/8 -> 6 3/4" Sheath Material Fibreglass Accuracy Class A Cable Type Briaded SS/Fibreglass/Teflon Temperature Range -20 to 370 Deg C Special Feature Pipe Clamp Mounting Style Clamp Weight 300-500g Factory Pack Qty 1 Datasheet Product Datasheet