Search results for "프라다지갑가격 싸싸숴러닷컴 SSSREO 탤ㄹH문의 50대루이비통가방추천 정품동일급 의령군최고퀄리티 미러급 레플리카 구찌뱀"
-
ART-B22-D300-SP4 + AI-P1A - 3 Pcs, 3 Phase Rogowski Coil Set, Class 1, 1 Amp AC, Sensitivity, and Measurement Range, 30cm Diameter, SP4 = 4.5M Integrator Cable
Free Aus Post Shipping for $300 SpendLEM ART-B22-D300-SP4 + AI-P1A - 3 Pcs, 3 Phase Rogowski Coil Set, Class 1, 1 Amp AC, Sensitivity, and Measurement Range, 30cm Diameter, SP4 = 4.5M Integrator Cable The universal Rogowski coil integrator AI-P1A complements LEM’s flexible clip-around coil ART and ARU range. The design is based on digital processing to give combined dynamic range, accuracy and versatility of use. It offers a wide range of output signals both RMS and instantaneous. AI-P1A is DIN rail mounted and can be stacked for multiphase application without spacing thanks to its low power dissipation. Input signal Accuracy Class 1 (IEC 61869-2) [1]. Linearity error ≤ 0.10 %. Protection degree IP2X. 35 mm DIN rail mounted. Push-in terminals. 1 Amp instantaneous output. 6 selectable sensitivities depending on Rogowski coil: 22.5, 70, 80, 85, 100, 120 mV/kA at 50 Hz. 12 selectable ranges: 100, 200, 300, 400, 500, 600, 800, 1000, 1500, 2000, 4000, 5000 A. Ambient operating temperature −25...+70 °C. Advantages Compact design for DIN rail assembly High accuracy Class 1 (IEC 61869-2) Setup by user via Select / Edit buttons Clear status indication via bi-color led Applications MV/LV substations on LV side: Transformer Condition Monitoring Power metering: current measurement for active power calculation Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation Power quality monitoring: electrical loads and distribution system equipment Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault Remote Terminal Units (RTU) Phasor Measurement Units (PMU) Standards IEC 61010-1: 2010 UL EMC: IEC 61326-1:2012 Options Cross Power Plug-in: side contacts to stack up to 3 Integrator modules and use only one power supply. Specification LEM Part Number ART-B22-D300-SP4 + AI-P1A - 3 Pcs Function 3 Phase AC Current Measurement Measuring Range Selectable 5000,4000,2000,1500,1000,800,600,500,400,300,200,100Amp Sensitivity Selectable 22.5,70,80,85,100,120mV/kA @ 50 Hz Output 1 Amp output Frequency Measuring Range 50-1500Hz (15th Harmonic) Operating Voltage 10-32VDC Accuracy 1% from 25 to 5000 Amp Current Consumption 100mA (max) Dimensions 100mm x 78mm x 15mm (Integrator), 30cm Diameter (Coils) Mounting Din Rail Mount Integrator to Coil cable 4.5M Twisted and Screened Integrator to Meter cable User Supplied Shielded cable 1.5mm sqr, up to 6m long Operating Temperature -25°C - 70°C Storage Temperature -45°C to 80°C Isolation (50Hz, 1 min) 1.5kV True RMS Response Time 160-190ms Termination Style Push-in for 1.5mm sqr wire Weight 58g Factory Pack Qty 1 Certifications UL, ROHS Datasheet AI-P1A Datasheet ART Series Datasheet Application Notes User Notice 1) The Rogowski coil can measure any primary current as there is no saturation effect. 2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts) 3) Frequency bandwidth and phase shift modelling schematic can be provided on request. 4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer) 5) Considering a primary conductor of at least ⌀ 15 mm, perpendicular and in contact with the Rogowski coil. 6) Considering an external conductor of at least ⌀ 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.
-
ART-B22-D70-SP6 + AI-PMUL - 3Pcs, 3 Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 7cm Diameter, SP6 = 6M Cable
Free Aus Post Shipping for $300 SpendLEM ART-B22-D70-SP6 + AI-PMUL - 3Pcs, 3 Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 7cm Diameter, SP6 = 6M Cable The universal Rogowski coil integrator AI-PMUL complements LEM’s flexible clip-around coil ART and ARU range. The design is based on digital processing to give combined dynamic range, accuracy and versatility of use. It offers a wide range of output signals both RMS and instantaneous. AI-PMUL is DIN rail mounted and can be stacked for multiphase application without spacing thanks to its low power dissipation. Input signal Accuracy Class 1 (IEC 61869-2) [1]. Linearity error ≤ 0.10 %. Protection degree IP2X. 35 mm DIN rail mounted. Push-in terminals. 4 selectable true RMS output signals: 0…20 mA, 4…20 mA, 0…5 V, 0…10 V. 2 selectable instantaneous output signals: 225 mV, 333 mV. 6 selectable sensitivities depending on Rogowski coil: 22.5, 70, 80, 85, 100, 120 mV/kA at 50 Hz. 12 selectable ranges: 100, 200, 300, 400, 500, 600, 800, 1000, 1500, 2000, 4000, 5000 A. Ambient operating temperature −25...+70 °C. Advantages Compact design for DIN rail assembly High accuracy Class 1 (IEC 61869-2) Setup by user via Select / Edit buttons Clear status indication via bi-color led Applications MV/LV substations on LV side: Transformer Condition Monitoring Power metering: current measurement for active power calculation Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation Power quality monitoring: electrical loads and distribution system equipment Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault Remote Terminal Units (RTU) Phasor Measurement Units (PMU) Standards IEC 61010-1: 2010 UL EMC: IEC 61326-1:2012 Included Options Cross Power Plug-in: side contacts to stack up to 3 Integrator modules and use only one power supply. Specification LEM Part Number ART-B22-D70-SP6 + AI-PMUL - 3Pcs Function 3 Phase AC Current Measurement Measuring Range Selectable 5000,4000,2000,1500,1000,800,600,500,400,300,200,100Amp Sensitivity Selectable 22.5,70,80,85,100,120mV/kA @ 50 Hz Output Selectable; Signal Conditioned True RMS 0-20mA, True RMS 4-20mA, True RMS 5V, True RMS 10V or 225mV, 333mV Direct Output (1 Amp output coming soon) Frequency Measuring Range 50-1500Hz (15th Harmonic) Operating Voltage 10-32VDC Accuracy 1% from 25 to 5000 Amp Current Consumption 100mA (max) Dimensions 100mm x 78mm x 15mm (Integrator), 7cm Diameter (Coils) Mounting Din Rail Mount Integrator to Coil cable 3M Twisted and Screened Integrator to Meter cable User Supplied Shielded cable 1.5mm sqr, up to 6m long Operating Temperature -25°C - 70°C Storage Temperature -45°C to 80°C Isolation (50Hz, 1 min) 1.5kV True RMS Response Time 160-190ms Termination Style Push-in for 1.5mm sqr wire Weight 58g Factory Pack Qty 1 Certifications UL, ROHS Datasheet AI-PMUL Datasheet ART Series Datasheet Applicaton Notes User Notice 1) The Rogowski coil can measure any primary current as there is no saturation effect. 2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts) 3) Frequency bandwidth and phase shift modelling schematic can be provided on request. 4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer) 5) Considering a primary conductor of at least ⌀ 15 mm, perpendicular and in contact with the Rogowski coil. 6) Considering an external conductor of at least ⌀ 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.
-
G22WP, HV Relay, 15kV, 50A, SPDT-CO, 24VDC Coil, 1,000,000 Cycles, 17kV Isolation, Screw Terminals, Panel Mount Version
Free Aus Post Shipping for $300 SpendGigavac G22WP, HV Relay, 15kV, 50A, SPDT-CO, 24VDC Coil, 1,000,000 Cycles, 17kV Isolation, Screw Terminals, Panel Mount Version Features Hermetically Sealed (Patented) rated to 85 Deg C High Efficiency Form C DC Coils Gas filled Small and lightweight Flexible package for installation Specification Gigavac Part Number G22WP Main Contact Type SPDT-CO (1 x CO Contacts) Auxiliary Contact Type N/A Coil Voltage 24VDC Load Current 50 Amp Mechanical Life @ 0 Amp 1,000,000 Operations Impulse Withstand 30kV rms Control Input Terminals M6 Mounting Style Panel Mount (M4) Load Voltage Range 15kVDC Standards UL508, NEC 690.11 and 690.12 DC Termination Style Screw Unit Weight 84g Factory Pack Qty 1 Datasheet Product Datasheet
-
ART-B22-D70-SP6 + AI-P1A- 3 Pcs, 3 Phase Rogowski Coil Set, Class 1, 1 Amp AC, Sensitivity, and Measurement Range, 7cm Diameter, SP3 = 3M integrator cable
Free Aus Post Shipping for $300 SpendART-B22-D70-SP6 + AI-P1A- 3 Pcs, 3 Phase Rogowski Coil Set, Class 1, 1 Amp AC, Sensitivity, and Measurement Range, 7cm Diameter, SP3 = 3M integrator cable The universal Rogowski coil integrator AI-P1A complements LEM’s flexible clip-around coil ART and ARU range. The design is based on digital processing to give combined dynamic range, accuracy and versatility of use. It offers a wide range of output signals both RMS and instantaneous. AI-P1A is DIN rail mounted and can be stacked for multiphase application without spacing thanks to its low power dissipation. Input signal Accuracy Class 1 (IEC 61869-2) [1]. Linearity error ≤ 0.10 %. Protection degree IP2X. 35 mm DIN rail mounted. Push-in terminals. 1 Amp instantaneous output. 6 selectable sensitivities depending on Rogowski coil: 22.5, 70, 80, 85, 100, 120 mV/kA at 50 Hz. 12 selectable ranges: 100, 200, 300, 400, 500, 600, 800, 1000, 1500, 2000, 4000, 5000 A. Ambient operating temperature −25...+70 °C. Advantages Compact design for DIN rail assembly High accuracy Class 1 (IEC 61869-2) Setup by user via Select / Edit buttons Clear status indication via bi-color led Applications MV/LV substations on LV side: Transformer Condition Monitoring Power metering: current measurement for active power calculation Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation Power quality monitoring: electrical loads and distribution system equipment Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault Remote Terminal Units (RTU) Phasor Measurement Units (PMU) Standards IEC 61010-1: 2010 UL EMC: IEC 61326-1:2012 Included Options Cross Power Plug-in: side contacts to stack up to 3 Integrator modules and use only one power supply. Specification LEM Part Number ART-B22-D70-SP6 + AI-P1A- 3 Pcs Function 3 Phase AC Current Measurement Measuring Range Selectable 5000,4000,2000,1500,1000,800,600,500,400,300,200,100Amp Sensitivity Selectable 22.5,70,80,85,100,120mV/kA @ 50 Hz Output 1 Amp output Frequency Measuring Range 50-1500Hz (15th Harmonic) Operating Voltage 10-32VDC Accuracy 1% from 25 to 5000 Amp Current Consumption 100mA (max) Dimensions 100mm x 78mm x 15mm (Integrator), 7cm Diameter (Coils) Mounting Din Rail Mount Integrator to Coil cable 6M Twisted and Screened Integrator to Meter cable User Supplied Shielded cable 1.5mm sqr, up to 6m long Operating Temperature -25°C - 70°C Storage Temperature -45°C to 80°C Isolation (50Hz, 1 min) 1.5kV True RMS Response Time 160-190ms Termination Style Push-in for 1.5mm sqr wire Weight 58g Factory Pack Qty 1 Certifications UL, ROHS Datasheet AI-P1A Datasheet ART Series Datasheet Applicaton Notes User Notice 1) The Rogowski coil can measure any primary current as there is no saturation effect. 2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts) 3) Frequency bandwidth and phase shift modelling schematic can be provided on request. 4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer) 5) Considering a primary conductor of at least ⌀ 15 mm, perpendicular and in contact with the Rogowski coil. 6) Considering an external conductor of at least ⌀ 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.
-
Elite E500C-5402, Panel Mount Network Recorder with Harmonics (31st) & PQ Parameters, Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty
Secure Elite E500C-5402, Panel Mount Network Recorder with Harmonics (31st) & PQ Parameters, Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty Automatic range of nominal current up to 6 A (Includes 5A/1A CT Input) and nominal voltage up to 500 V L-L, 300V L-N Configurable 2 x Tariff Inputs or 2 x Pulse Outputs, or Alarm Outputs Dual Loggers, configurable for Instant or accumulated energy Configurable 2 x Tariff Inputs or 2 x Pulse Outputs, or Alarm Outputs RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Measurements of energy in all 4 quadrants Average values of measurands per interval RS 485 communication up to 38400 bit/s as standard Optional Protocol Modules Modbus TCP, BACNet IP, Profinet, SCADA EC61850 Optional Modules for Analogue outputs and Relay Alarms The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : Measurement of instantaneous values and accumulated energy. Includes Harmonics to the 31st Accuracy class 0.5S Dual Internal Loggers Measurement of 20 minimal and maximal values in different time periods RS 232/RS 485 communication up to 38400 bit/s or Ethernet communication MODBUS communication protocol Optional Protocol Modules Modbus TCP, BACNet IP, Profinet, SCADA EC61850 Configurable 2 x Tariff Inputs or 2 x Pulse Outputs, or Alarm Outputs Universal or AC/DC power supply Graphic Colour TFT 320 x 240 pixels (53x70mm) Automatic range of nominal current up to 6 A and nominal voltage up to 500 V Multilingual support User-friendly Free ECon Configuration software Specification Secure Part Number E500C-5202 Functions Power Quality Meter (31st Hamonic), Energy Meter, Network Recorder Supply Voltage Universal 35..300V DC, 85..300VAC Nominal Measurement Range 240V L-N, 1/5 Amp, 415V L-L 1/5 Amp Maximum Measurement Range 300V L-N, 1/5 Amp, 500V L-L 1/5 Amp Alarm Optional Module 2 Relay/Pulse Outputs Tariff/Digital Inputs TOU Tarriff Clock Accuracy Class 0.5S (I,U,F,PF,θ,THD) Class 1(Active), Class 2 (Reactive) Analogue Output Optional Module 2 x Programmable Analogue Outputs Internal Memory 2 x 8MB Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV RS232/RS485 N/A Optional CT Termination Ring Terminals Weight 600g Certification CE, CSA, ROHS Warranty 10 Years from dispatch from Secure Warehouse Factory Pack Qty 1 EU Directives Degree on electrical equipment designed for use within certain voltage limits URLRS 53/00 (Directive 73/23/EEC on low voltage): SIST EN 61010-1:2002 Safety Requirement for electrical equipment for measurement, control and laboratory use, part1 : general requirement Decree on electromagnetic Compatibility (EMC) URLRS 61/00 (Directive 89/336/EEC on electromagnetic compatibility): SIST EN 61036 item 4.5: 1998 Meters for active energy (class 1 and 2) Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP52 (IP00 for terminals) in compliance with SIST EN 60529:1997 Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C Datasheet Product Datasheet Cross Reference The Following meters are close equivalents to Elite 500 Series. For further details please contact Fastron Sales Team Elite 500_400_300_100 series competition replacement for Schneider Siemens Accuenergy (RS485 +DNP3 default) Socomec Selec PM 5000 series PAC 2000 series ACCUVIM-CL + DNP3.0 DIRIS A-20 Selec MFM376 PM 5100 PAC 3200 ACCUVIM-CL + DNP3.0 DIRIS A-20 MFM384, CL-1, RS485 PM 5300 ACCUVIM-IIR DIRIS A-20 MFM383A PM 5500 PAC 4200 ACCUVIM-IIR(+ BACnet) DIRIS A-20 MFM384. RS485 PM 6463 Siemens 7KMPAC4200 ACCUVIM-IIR (+ Profibus) DIRIS A-30/ DIRIS - A60 (PQ Feature) MFM384-C-CE-CL05, RS485 PM 5650 ACCUVIM-IIR (+ IEC 61850) DIRIS A-30 + Profibus MFM384-C-CE-CL05, RS485 PM 5760 ACCUVIM-EL DIRIS A-30 +Ethernet MFM384-C-CE-CL05, RS485 PM5330 ACCUVIM-EL (+ BACnet) DIRIS A-30/ DIRIS A-60 PM 5560 ACCUVIM-EL (+ Profibus) DIRIS A-30/ DIRIS A-60 DM6200H ACCUVIM-EL (+ IEC 61850) PM2220 ACCUVIM-II R +Ethernet PM2230 / DM2120 (LED) PM 5350
$725.00
$855.50 inclGST -
MC740 S SUENC, Panel Mount Measuring Center 3 Phase, Class 0.5 50-500V L-L 50/60Hz Measurement, Universal 20-300VDC or 48-276VAC 40-70Hz Supply, Ethernet & USB Comms, w/ Supercap
Free Aus Post Shipping for $300 SpendIskra Doo MC740 S SUENC Series 3 Phase Measuring Center Smart Power Meter Automatic range of nominal current up to 12.5 A (Includes 5A/1A CT Input) and nominal voltage up to 750 V L-N Adjustable tariff clock, display of electric energy consumption in optional currency Optional RS 232/RS 485 communication up to 115,200 bit/s or Ethernet communication Usage The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : Measurement of instantaneous values of more than 140 quantities (U, I, P, Q, S, PF, PA, f, f, MD, energy, energy price by tariffs, etc.). Accuracy class 0.5 or 0.2 (on demand) Measurement of 40 minimal and maximal values in different time periods 32 adjustable alarms Wide frequency range from 16 Hz to 400 Hz RS 232/RS 485 communication up to 115,200 bit/s or Ethernet communication MODBUS and DNP3 communication protocol MMC memory card for setting and upgrading the meter Up to 4 inputs or outputs (analogue outputs, pulse outputs, alarm outputs, tariff inputs) Universal or AC power supply Graphic LCD 128 x 64 dots with illumination Automatic range of nominal current up to 5 A and nominal voltage up to 750 V Adjustable tariff clock, display of electric energy consumption in optional currency Multilingual support User-friendly PC MiQen software 128 samples in one period Measurement of THD on Current or Voltage from 0 to 400% Specification Iskra Doo Part Number MC740 S SUENC Functions Power Quality Meter, Energy Meter, Power Transducer, Network Analyser Supply Voltage Universal 48-240VAC 40-70Hz, 20-300VDC, < 5VA Nominal Measurement Range 50-500V L-N, 5 Amp 50/60Hz Maximum Measurement Range 750V L-N, 12.5 Amp Alarm N/A (Optional 4 Relays, 32 Alarms, 4 Groups) Analogue Output N/A (Optional 4 x 20mA) Digital Input N/A (Optional 4 x 230VAC/DC,75..130VAC/DC..5..48VAC/DC) Pulse Output N/A (Optional) Pulse Input N/A (Optional) Bistable Switch/Latching Relay Alarm N/A (Optional) Status (Watchdog) Output N/A (Optional) Tariff Input N/A (Optional 4 x 230VAC/DC,75..130VAC/DC..5..48VAC/DC) Accuracy Class 0.5 (I,U,F,PF,θ,THD) (Class 0.2 Optional) Class 1(Active), Class 2 (Reactive) Battery Backup Supercap Real Time Clock 1min/month (30ppm) Internal Memory 8MB MMC up to 2GB Isolation 3.7kV Ethernet RJ45 10/100Mbit/s USB Yes (2400-115200 b/s) RS232/RS485 N/A (optional 2400-115200 b/s) Weight 600g Certification UL, CSA, ROHS Factory Pack Qty 1 EU Directives Degree on electrical equipment designed for use within certain voltage limits URLRS 53/00 (Directive 73/23/EEC on low voltage): SIST EN 61010-1:2002 Safety Requirement for electrical equipment for measurement, control and laboratory use, part1 : general requirement Decree on electromagnetic Compatibility (EMC) URLRS 61/00 (Directive 89/336/EEC on electromagnetic compatibility): SIST EN 61036 item 4.5: 1998 Meters for active energy (class 1 and 2) Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP52 (IP00 for terminals) in compliance with SIST EN 60529:1997 Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22 Datasheet Product Datasheet User Manual
-
DVL 50 UI, Digital Voltage Transducer 50V Input, 4-20mA output, +/- 15V…24VDC, 8.5kV Isolation
LEM DVL 50 UI, Digital Voltage Transducer 50V Input, 4-20mA output, +/- 15V…24VDC, 8.5kV Isolation Features Bandwidth DC to 14kHz Multi Range through pin selection Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 50 UI Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 50V Measurement Range +/- 75V Output 4 - 20mA Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style M5 Screw Unit Weight 270g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$661.00
$779.98 inclGST -
E500R-51D2, Panel Mount Network Recorder & 1000A/140mm Rogowski Coils, with Harmonics (15th), Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Logging Memory, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty
Secure E500R-51D2, Panel Mount Network Recorder & 1000A/140mm Rogowski Coils, with Harmonics (15th), Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Logging Memory, TFT Touch Screen Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty Automatic range of nominal current up to 6 A (Includes 5A/1A CT Input) and nominal voltage up to 500 V L-L, 300V L-N Dual Loggers, configurable for Instant or accumulated energy RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Measurements of energy in all 4 quadrants Average values of measurands per interval RS 485 communication up to 38400 bit/s as standard Optional Protocol Modules Modbus TCP, BACNet IP, Profinet, SCADA EC61850 Optional Modules for Analogue outputs and Relay Alarms The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : Measurement of instantaneous values and accumulated energy. Includes Harmonics to the 15th Accuracy class 0.5S Dual Internal Loggers Measurement of 20 minimal and maximal values in different time periods RS 232/RS 485 communication up to 38400 bit/s MODBUS communication protocol Optional Protocol Modules Modbus TCP, BACNet IP, Profinet, SCADA EC61850 Configurable 2 x Tariff Inputs or 2 x Pulse Outputs, or Alarm Outputs Universal or AC/DC power supply Graphic Colour TFT 320 x 240 pixels (53x70mm) Automatic range of nominal current up to 6 A and nominal voltage up to 500 V Multilingual support User-friendly Free ECon Configuration software Specification Secure Part Number E500R-51D2 Functions Power Quality Meter, Energy Meter Rogowski Coil Rating/Size 1000A/140mm Supply Voltage Universal 35..300V DC, 85..300VAC Nominal Measurement Range 240V L-N, 100mV/kA @ 50 Hz, 415V L-L Maximum Measurement Range 300V L-N, 100mV/kA @ 50 Hz, 500V L-L Alarm Optional Module 2 Relay/Pulse Outputs Tariff/Digital Inputs TOU Tarriff Clock Accuracy Class 0.5S (I,U,F,PF,θ,THD) Class 1(Active), Class 2 (Reactive) Analogue Output Optional Module 2 x Programmable Analogue Outputs Internal Memory 2 x 8MB Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV RS232/RS485 N/A Optional CT Termination Ring Terminals Weight 600g Certification CE, CSA, ROHS Warranty 10 Years from dispatch from Secure Warehouse Factory Pack Qty 1 EU Directives Degree on electrical equipment designed for use within certain voltage limits URLRS 53/00 (Directive 73/23/EEC on low voltage): SIST EN 61010-1:2002 Safety Requirement for electrical equipment for measurement, control and laboratory use, part1 : general requirement Decree on electromagnetic Compatibility (EMC) URLRS 61/00 (Directive 89/336/EEC on electromagnetic compatibility): SIST EN 61036 item 4.5: 1998 Meters for active energy (class 1 and 2) Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP52 (IP00 for terminals) in compliance with SIST EN 60529:1997 Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C Datasheet Product Datasheet Cross Reference The Following meters are close equivalents to Elite 500 Series. For further details please contact Fastron Sales Team Elite 500_400_300_100 series competition replacement for Schneider Siemens Accuenergy (RS485 +DNP3 default) Socomec Selec PM 5000 series PAC 2000 series ACCUVIM-CL + DNP3.0 DIRIS A-20 Selec MFM376 PM 5100 PAC 3200 ACCUVIM-CL + DNP3.0 DIRIS A-20 MFM384, CL-1, RS485 PM 5300 ACCUVIM-IIR DIRIS A-20 MFM383A PM 5500 PAC 4200 ACCUVIM-IIR(+ BACnet) DIRIS A-20 MFM384. RS485 PM 6463 Siemens 7KMPAC4200 ACCUVIM-IIR (+ Profibus) DIRIS A-30/ DIRIS - A60 (PQ Feature) MFM384-C-CE-CL05, RS485 PM 5650 ACCUVIM-IIR (+ IEC 61850) DIRIS A-30 + Profibus MFM384-C-CE-CL05, RS485 PM 5760 ACCUVIM-EL DIRIS A-30 +Ethernet MFM384-C-CE-CL05, RS485 PM5330 ACCUVIM-EL (+ BACnet) DIRIS A-30/ DIRIS A-60 PM 5560 ACCUVIM-EL (+ Profibus) DIRIS A-30/ DIRIS A-60 DM6200H ACCUVIM-EL (+ IEC 61850) PM2220 ACCUVIM-II R +Ethernet PM2230 / DM2120 (LED) PM 5350
$1,437.00
$1,695.66 inclGST -
LPSR 50-NP, C/L Multi Range Hall Effect Current Sensor, 50 Amp, 2.5V ref in ref Out, PCB Mount
Free Aus Post Shipping for $300 SpendLEM LKSR 50-NP Closed Loop AC/DC Hall Effect Sensor Features Closed loop current transducer Voltage output 4.3kV Isolation Frequency bandwidth 300kHz Single supply + 5 V Galvanic isolation between primary and secondary Low power consumption Compact design for PCB mounting Overcurrent detection 4 x Ipn Advantages CKSR footprint compatible Very good dv/dt immunity Low foot-print Low offset drift Reference pin with two modes REF IN and REF OUT Extended measuring range for unipolar measurement. High creepage / clearance distances Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Solar Inverter Standards EN 50178: 1997 IEC 61800-2: 2015 IEC 61800-3: 2004 IEC 61800-5-1: 2007 IEC 62109-1: 2010 UL 508: 2013 IEC 62477-1: 2012 Application Domain Industrial Specification LEM Part Number LPSR 50-NP Technology Closed Loop Hall Effect Aperture None ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 50 Amp Measurement Range +/- 150Amp Output 2.5 Vref Isolation 4.3 kV Bandwidth DC-300 kHz Mounting Style PCB Mount Operating Temperature Range -40°C / 105°C Accuracy 0.75% Termination Style PCB Unit Weight 10g Factory Packaging 25 Datasheet Datasheet Application Notes LEM Applications Manual 3rd Edition Alternatives LKSR 25-NP