LEM HOYS 560-S-0100 Series Closed Loop AC/DC Hall Effect Sensor
Features
Open loop multi-range current transducer
Voltage output
Single supply +5 V
Overcurrent detect 2.93 × IPN (peak value)
Galvanic separation between primary and secondary circuit
Low power consumption
For busbar mounting
Aperture: 21.5 × 13 mm
Factory calibrated ● Mating JST connector:
housing PAP-05V-S
contact SPHD-00xT-P0.5.
Advantages
Low offset drift
Over-drivable Vref
Creepage / clearance > 10.5 mm
Fast response
Low profile 2 mm pitch connector for 22 to 28 AWG wire.
Applications
AC variable speed and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Combiner box
Solar inverter on DC side of the inverter (MPPT).
Standards
IEC 61800-2: 2015
IEC 61800-3: 2004
IEC 61800-5-1: 2007 ● IEC 62109-1: 2010 ● UL 508: 2013.
Application Domain
Industrial.
Specification
LEM Part Number
HOYS 560-S-0100
Technology
Open Loop Hall Effect
Aperture
21.5 x 13mm
ROHS
Yes
Supply Voltage
5 VDC
Load Current (RMS + DC)
560 Amp
Measurement Range
+/-1400 Amp
Output
2.5 Vref
Isolation
5.4 kV
Bandwidth
DC-180 kHz
Mounting Style
Busbar Mount
Operating Temperature Range
-40°C / 105°C
Accuracy
1%
Termination Style
JST B05B-PASK or equivalent
Unit Weight
101g
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM LES 15-NP, C/L Multi Range Hall Effect Current Sensor, 15 Amp, 2.5V ref in ref Out, PCB Mount, X = 2.25%, 4.3kV Isolation
Features
Closed loop current transducer
Voltage output
4.3kV Isolation
Frequency bandwidth 300kHz
Single supply + 5 V
Galvanic isolation between primary and secondary
Low power consumption
Compact design for PCB mounting
Vref IN Vref OUT
Multirange through PCB routing
Advantages
LTS footprint compatible
Zero insertion losses
Very good linearity
Very good dv/dt immunity
High immunity to external interference
Current overload capability
Optimised response time
Applications
AC variable speed and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Solar inverters
Standards
IEC 61800-1: 1997
IEC 61800-2: 2015
IEC 61800-3: 2004
IEC 61800-5-1: 2007
IEC 62109-1: 2010
IEC 62477-1: 2012
UL 508:2013.
Application Domain
Industrial
Specification
LEM Part Number
LES 15-NP
Technology
Closed Loop Multirange Hall Effect
Aperture
No Aperture
ROHS
Yes
Supply Voltage
5 VDC
Load Current (RMS + DC)
15 Amp
Measurement Range
+/-51 Amp
Output
2.5 Vref
Isolation
4.3 kV
Bandwidth
DC-300 kHz
Mounting Style
PCB Mount
Operating Temperature Range
-40°C / 105°C
Accuracy
2.25%
Termination Style
PCB
Unit Weight
10g
Factory Packaging
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Alternatives
LTS 15-NP
Iskra Doo TSD 2 230VAC, Twilight Switch with Digital Time Clock, 230VAC +/-10% Power Supply, 8 Amp SPDT CO Relay
TSD 2 Series serves to monitor Light levels (10 - 50,000 lx) based on ditigal time clock settings, and provides Relay alarm output with digital adjustable timing function.
Features :
Timer overide feature for times when light is not reqtuired in the dark
Random Switching to Simulate Presence in House
Used to control lights on the basis of ambient light intensity
External sensor IP44 suitable for mounting on the wall (cover and holder of a sensor are a part of the package)
Time Switch Control
Red LED output indication
2-MODULE, DIN rail mounting Level of ambient intensity is monitored by an external sensor and output is switched according to set level on the device
Control input for additional control, e.g. time switch, preswitch etc.
Level of illumination adjustable in two ranges: 1 - 100 lx and 100 - 50000 lx Adjustable time delay to eliminate short term fluctuation in illumination
Supply voltage AC 230 V or AC/DC 12 - 240 V
Output contact: 1x changeover/ S
Applications :
Heating bars in sliding rails
Heating cables
Indication of current flow
Controlling of 1-phase motor consumption
Specification
Iskra Doo Part Number
TSD 2 230VAC
Voltage Range
AC 230 VAC
Operating Range
-15 %; +10 %
Light intensity sensing range
10 - 50,000lx
Time Adjustment
Digital Menu
Setting Accuracy
+/-1s per day at 23°C
Burden
max. 12 VA
Repeatability
1 %
Temperature Drift
0.1%/°C
Output
SPDT Relay 8 Amp
Number of contacts
1x changeover/ SPDT (AgNi / Silver Alloy)
Rating
8 A / AC1
Breaking capacity
4000 VA / AC1, 384 W / DC
Switching voltage
250 V AC1 / 24 V DC
Min. breaking capacity DC
500 mW
Indication of state
red LED
Mechanical life
1 x 107
Electrical life (AC1)
1 x 105
Operating temperature
-20 ... +55 °C
Storage temperature
-30 ... +70 °C
Electrical strength
4 kV (supply - output)
Operating position
any
Mounting
DIN rail EN 60715
Protection degree
IP 40 from front panel / IP 10 terminals
Overvoltage cathegory
III.
Pollution degree
2
Max. cable size (mm )2
solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5
Dimensions
90 x 17,6 x 64 mm
Weight
109 g
Standards
EN 60255-6, EN 61010-1
Datasheet
Product Datasheet
LEM LV Series Closed Loop AC/DC Hall Effect Voltage Sensor
Features
Bandwidth DC to 25kHz
Multi Range through pin selection
Closed loop transducer using Hall effect
Compact and versatile
PCB Mount
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Voltage overload capability
Low power consumption
Applications
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Water Treatment Electronics
Specification
LEM Part Number
LV 25-P/SP17
Technology
Closed Loop Hall Effect
Aperture
No Aperture
ROHS
Yes
Supply Voltage
+/-12..15 VDC Bipolar, Isolated
Primary Nominal Current (RMS + DC)
10 mA
Measurement Range
10 - 700V (0 -14mA)
Output
25 mA
Isolation
2.5 kV
Bandwidth
DC-25 kHz
Mounting Style
PCB Mount
Operating Temperature Range
-40°C / 90°C
Accuracy
0.9%
Termination Style
Through Hole PCB
Unit Weight
22g
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM LT 2005-T C/L Hall Effect Current Sensor, Ipn = 2000 Amp, Isn = 400mA, +/-24VDC Supply, X = 0.3%, Busbar mount
Features
Bipolar and insulated current measurement up tp 3000 Amp
Current output
Bandwidth DC to 100kHz
Closed loop (compensated) current transducer
Panel mounting
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low offset drift over temperature
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Applications
Windmill Inverters
Test and Measurement
Substations
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Application Domain
Industrial
Standards
EN 50178:1997
IEC61010-1:2010
UL 508:2010
Specification
LEM Part Number
LT 2005-T
Technology
Closed Loop Hall Effect
Aperture
No Aperture
ROHS
Yes
Supply Voltage
+/- 15 VDC to +/- 24 VDC Bipolar, Isolated
Load Current (RMS + DC)
2000 Amp
Measurement Range
+/- 3000 Amp
Output
400 mA
Isolation
6 kV
Bandwidth
DC-100 kHz
Mounting Style
Busbar Mount
Operating Temperature Range
-10°C / 85°C
Accuracy
0.3%
Termination Style
M5 theaded studs
Unit Weight
4.4kg
Factory Pack Quantity
4
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
H-300-2-24, Split Core Hall Effect DC Current Transducer, 0-300 Amp DC, 4-20mA unipolar output, 31mm aperture, 24VDC supply
Compact and versatile Split Core DC current sensor, 0-300 Amp DC, 4-20mA Unipolar Output
Features
⌀31mm Aperture
DC Unipolar Measurement
4-20mA analogue output
Busbar, or DIN Rail Mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Kit available
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
H-300-2-24
Technology
DC Hall Effect Current Transducer with Process Output
ROHS
Yes
Supply Voltage
24VDC
Nominal Current (DC)
0-300 Amp
Response Time
< 200mS
Output
Unipolar 4-20mA Analogue
Isolation
4kV (AC, 50Hz, 1 min)
Bandwidth
DC
Mounting Style
DIN Rail Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Elevator Screw
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet
LEM LTC 350-T Open Loop AC/DC Hall Effect Sensor
Features
Bipolar and insulated current measurement up tp 1200 Amp
Current output
Bandwidth DC to 100kHz
Closed loop (compensated) current transducer
Panel mounting
Insulated plastic case recognized according to UL 94-V0
With Busbar
Advantages
Very good linearity
High accuracy
Low offset drift over temperature
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Applications
Railway Equipment
Windmill Inverters
Test and Measurement
Substations
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Application Domain
Industrial
Standards
EN 50178:1997
IEC61010-1:2010
UL 508:2010
Specification
LEM Part Number
LTC 350-T
Technology
Closed Loop Hall Effect
Aperture
No Aperture
ROHS
Yes
Supply Voltage
+/- 15 VDC to +/- 24 VDC Bipolar, Isolated
Load Current (RMS + DC)
350 Amp
Measurement Range
+/- 1200 Amp
Output
175 mA
Isolation
12 kV
Bandwidth
DC-100 kHz
Mounting Style
Busbar Mount
Operating Temperature Range
-10°C / 85°C
Accuracy
0.5%
Termination Style
Faston 45° Nickel Plated
Unit Weight
650g
Factory Pack Quantity
6
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Accessories