Search results for "텔레@bitcoinsyri!*xrp판매xrp매입sol판매처"
-
TSD 2 230VAC, Twilight Switch with Digital Time Clock, 230VAC +/-10% Power Supply, 8 Amp SPDT CO Relay
Free Aus Post Shipping for $300 SpendIskra Doo TSD 2 230VAC, Twilight Switch with Digital Time Clock, 230VAC +/-10% Power Supply, 8 Amp SPDT CO Relay TSD 2 Series serves to monitor Light levels (10 - 50,000 lx) based on ditigal time clock settings, and provides Relay alarm output with digital adjustable timing function. Features : Timer overide feature for times when light is not reqtuired in the dark Random Switching to Simulate Presence in House Used to control lights on the basis of ambient light intensity External sensor IP44 suitable for mounting on the wall (cover and holder of a sensor are a part of the package) Time Switch Control Red LED output indication 2-MODULE, DIN rail mounting Level of ambient intensity is monitored by an external sensor and output is switched according to set level on the device Control input for additional control, e.g. time switch, preswitch etc. Level of illumination adjustable in two ranges: 1 - 100 lx and 100 - 50000 lx Adjustable time delay to eliminate short term fluctuation in illumination Supply voltage AC 230 V or AC/DC 12 - 240 V Output contact: 1x changeover/ S Applications : Heating bars in sliding rails Heating cables Indication of current flow Controlling of 1-phase motor consumption Specification Iskra Doo Part Number TSD 2 230VAC Voltage Range AC 230 VAC Operating Range -15 %; +10 % Light intensity sensing range 10 - 50,000lx Time Adjustment Digital Menu Setting Accuracy +/-1s per day at 23°C Burden max. 12 VA Repeatability 1 % Temperature Drift 0.1%/°C Output SPDT Relay 8 Amp Number of contacts 1x changeover/ SPDT (AgNi / Silver Alloy) Rating 8 A / AC1 Breaking capacity 4000 VA / AC1, 384 W / DC Switching voltage 250 V AC1 / 24 V DC Min. breaking capacity DC 500 mW Indication of state red LED Mechanical life 1 x 107 Electrical life (AC1) 1 x 105 Operating temperature -20 ... +55 °C Storage temperature -30 ... +70 °C Electrical strength 4 kV (supply - output) Operating position any Mounting DIN rail EN 60715 Protection degree IP 40 from front panel / IP 10 terminals Overvoltage cathegory III. Pollution degree 2 Max. cable size (mm )2 solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5 Dimensions 90 x 17,6 x 64 mm Weight 109 g Standards EN 60255-6, EN 61010-1 Datasheet Product Datasheet
-
LV 25P/SP17, C/L Hall Effect Voltage Sensor 10mA@10-500V, 25mA out, X = 0.9%
Free Aus Post Shipping for $300 SpendLEM LV Series Closed Loop AC/DC Hall Effect Voltage Sensor Features Bandwidth DC to 25kHz Multi Range through pin selection Closed loop transducer using Hall effect Compact and versatile PCB Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number LV 25-P/SP17 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-12..15 VDC Bipolar, Isolated Primary Nominal Current (RMS + DC) 10 mA Measurement Range 10 - 700V (0 -14mA) Output 25 mA Isolation 2.5 kV Bandwidth DC-25 kHz Mounting Style PCB Mount Operating Temperature Range -40°C / 90°C Accuracy 0.9% Termination Style Through Hole PCB Unit Weight 22g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
BH-200-2-24, Split Core Hall Effect DC Current Transducer, +/-200 Amp DC, 4-20mA Bipolar output, 31mm aperture, 24VDC supply
BH-200-2-24, Split Core Hall Effect DC Current Transducer, +/-200 Amp DC, 4-20mA Bipolar output, 31mm aperture, 24VDC supply Compact and versatile Split Core DC current sensor, +/-200 Amp DC, 4-20mA Bipolar Output Features ⌀31mm Aperture Split Core DC Bipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number BH-200-2-24 Technology DC Hall Effect Current Transducer with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) +/-200 Amp DC Response Time < 200mS Output Bipolar 4-20mA Analogue Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$435.00
$513.30 inclGST -
H-300-2-24, Split Core Hall Effect DC Current Transducer, 0-300 Amp DC, 4-20mA unipolar output, 31mm aperture, 24VDC supply
Free Aus Post Shipping for $300 SpendH-300-2-24, Split Core Hall Effect DC Current Transducer, 0-300 Amp DC, 4-20mA unipolar output, 31mm aperture, 24VDC supply Compact and versatile Split Core DC current sensor, 0-300 Amp DC, 4-20mA Unipolar Output Features ⌀31mm Aperture DC Unipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number H-300-2-24 Technology DC Hall Effect Current Transducer with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-300 Amp Response Time < 200mS Output Unipolar 4-20mA Analogue Isolation 4kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
-
LTC 1000-TF C/L Hall Effect Current Sensor, 1000 Amp, 200mA Output, +/-15..24V, Panel Mount, w/ busbar & feet, X = 0.4%
Free Aus Post Shipping for $300 SpendLEM LTC 1000-TF Open Loop AC/DC Hall Effect Sensor Features Bipolar and insulated current measurement up tp 3000 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Railway Equipment Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LTC 1000-TF Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 1000 Amp Measurement Range +/- 3000 Amp Output 200 mA Isolation 13.4 kV Bandwidth DC-100 kHz Mounting Style Busbar Mount and Panel Mount (with feet) Operating Temperature Range -10°C / 85°C Accuracy 0.4% Termination Style Faston 45° 6.3 x 0.8mm and M5 threaded studs Unit Weight 1270g Factory Pack Quantity 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition Accessories For Feet Kit or Busbar Kit see datasheet or LEM accessories for more details
-
LTC 200-S/SP1, C/L Hall Effect Current Sensor, 200 Amp, 200mA Output, +/-15..24V, Panel Mount, w/ busbar, X = 0.5%, ø27.5mm
Free Aus Post Shipping for $300 SpendLEM LTC Series Open Loop AC/DC Hall Effect Sensor Features Bipolar and insulated current measurement up tp 400 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Railway Equipment Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LTC 200-S/SP1 Technology Closed Loop Hall Effect Aperture ø27.5mm ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 200 Amp Measurement Range +/- 400 Amp Output 200 mA Isolation 12 kV Bandwidth DC-100 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 0.5% Termination Style Faston 45° 6.3 x 0.8mm and M4 threaded studs Unit Weight 300g Factory Pack Quantity 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition Accessories For Feet Kit or Busbar Kit see datasheet or LEM accessories for more details
-
AKR 5 B420L, Split Core AC Current Sensor, selectable 2, 5 Amp, True RMS 4-20mA output, 21.7mm sqr aperture
Free Aus Post Shipping for $300 SpendLEM AKR 5 B420L Series True RMS Solid Core AC Current Sensor with Process Outputs Compact and versatile Split Core AC current sensor, selectable 2 or 5 Amp True RMS. Choice of output types: 4-20 mA, 0-5 V or 0-10 V Features Split Core True RMS output 4-20mA current output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for busbar/cable up to 21.7mm sqr High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number AK 50 B420L, Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage 24VDC Loop Powered Nominal Current (RMS + DC) 2, 5 Amp Selectable Maximum Measurement Current (Peak) 3.4, 10.1 Amp Output 4-20mA True RMS Aperture 21.7mm sqr Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
DK 100 C5, Hall Effect DC Current Transducer, 50, 75, 100A DC, 0-5V unipolar output, 20-50VDC supply
Free Aus Post Shipping for $300 SpendLEM DK 100 C5, Hall Effect DC Current Transducer, 50, 75, 100A DC, 0-5V unipolar output, 20-50VDC supply Compact and versatile Split Core DC current sensor, selectable 50, 75, 100 Amp DC. Choice of output types: 0-20mA, 4-20 mA, 0-5 V or 0-10 V Features ⌀19.1mm Aperture DC Unipolar Measurement 0-5V voltage output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number DK 100 C5 Technology DC Current Transformer with Process Output ROHS Yes Supply Voltage 20-50VDC Nominal Current (RMS + DC) 50,75,100 Amp Selectable Response Time < 100ms Output 0-5V Analogue Isolation 3kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 2% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
HXN 25-P Hall Effect Current Sensor, 25 Amp, +/-4V output, no aperture, +/-15V Supply, PCB Mount, X = 1%
Free Aus Post Shipping for $300 SpendLEM HXN 25-P Series Open Loop AC/DC Hall Effect Sensor Features Open loop current transducer Voltage output Single supply +5 V Galvanic separation between primary and secondary circuit For PCB mounting No Aperture Advantages Small size and space saving Same package for wide primary current range High immunity to external interference Fast response High insulation capability Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box Solar inverter on DC side of the inverter (MPPT). Standards EN 50178: 1997 IEC 61010-1: 2010 IEC 61326-1: 2012 UL 508: 2010 Application Domain Industrial. Specification LEM Part Number HXN 25-P Technology Open Loop Hall Effect Aperture None ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 25 Amp Measurement Range +/-60 Amp Output 2.5 Vref Isolation 3 kV Bandwidth DC-50 kHz Mounting Style PCB Mount Operating Temperature Range -40°C / 105°C Accuracy 1.35% Termination Style PCB Through Hole Unit Weight 8g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
LTC 200-SF/SP2, C/L Hall Effect Current Sensor, 200 Amp, 200mA Out, +/-15..24VDC, Panel Mount, X = 0.5%, ø27.5mm
Free Aus Post Shipping for $300 SpendLEM LTC 200-SF/SP2, C/L Hall Effect Current Sensor, 200 Amp, 200mA Out, +/-15..24VDC, Panel Mount, X = 0.5%, ø27.5mm Features Bipolar and insulated current measurement up tp 400 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Railway Equipment Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LTC 200-SF Technology Closed Loop Hall Effect Aperture ø27.5mm ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 200 Amp Measurement Range +/- 400 Amp Output 200 mA Isolation 12 kV Bandwidth DC-100 kHz Mounting Style Panel Mount (with feet) Operating Temperature Range -10°C / 85°C Accuracy 0.5% Termination Style Faston 45° 6.3 x 0.8mm and M5 threaded studs Unit Weight 300g Factory Pack Quantity 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition Accessories For Feet Kit or Busbar Kit see datasheet or LEM accessories for more details
-
LTC 350-T C/L Hall Effect Current Sensor, 350 Amp, 175mA Output, +/-15..24V, Panel Mount, w/ busbar, X = 0.3%
Free Aus Post Shipping for $300 SpendLEM LTC 350-T Open Loop AC/DC Hall Effect Sensor Features Bipolar and insulated current measurement up tp 1200 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 With Busbar Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Railway Equipment Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LTC 350-T Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 350 Amp Measurement Range +/- 1200 Amp Output 175 mA Isolation 12 kV Bandwidth DC-100 kHz Mounting Style Busbar Mount Operating Temperature Range -10°C / 85°C Accuracy 0.5% Termination Style Faston 45° Nickel Plated Unit Weight 650g Factory Pack Quantity 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition Accessories For Feet Fixing kit see Part # 93.34.43.100.0