DK 200 B10, Split Core Hall Effect DC Current Transducer, 100, 150, 200A DC, 0-10V unipolar output, 20-50VDC supply
Free Aus Post Shipping for $300 SpendLEM DK 200 B10, Split Core Hall Effect DC Current Transducer, 100, 150, 200A DC, 0-10V unipolar output, 20-50VDC supply Compact and versatile Split Core DC current sensor, selectable 100, 150, 200 Amp DC. Choice of output types: 4-20 mA, 0-5 V or 0-10 V Features Split Core DC Unipolar Measurement 0-10V Voltage output Busbar or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for busbar/cable up to 21.7mm sqr High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number DK 200 B10 Technology DC Current Transformer with Process Output ROHS Yes Supply Voltage 20-20VDC Nominal Current (RMS + DC) 100,150,200 Amp Selectable Response Time < 100ms Output 0-10V Analogue Isolation 3kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 2% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
DK 300 B10, Split Core Hall Effect DC Current Transducer, Multirange 150, 225, 300A DC, 0-10V unipolar output, 20-50VDC supply
LEM DK 300 B10, Split Core Hall Effect DC Current Transducer, Multirange 150, 225, 300A DC, 0-10V unipolar output, 20-50VDC supply Compact and versatile Split Core DC current sensor, selectable 150, 225, 300 Amp DC. Choice of output types: 4-20 mA, 0-5 V or 0-10 V Features Split Core DC Unipolar Measurement 0-10V Voltage output Busbar or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for busbar/cable up to 21.7mm sqr High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number DK 300 B10 Technology DC Current Transformer with Process Output ROHS Yes Supply Voltage 20-20VDC Nominal Current (RMS + DC) 150,225,300 Amp Selectable Response Time < 100ms Output 0-10V Analogue Isolation 3kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 2% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$1,080.00
$1,274.40 inclGST -
DK 100 B020, Split Core Hall Effect DC Current Transducer, 50, 75, 100A DC, 0-20mA unipolar output, 20-50VDC supply
Free Aus Post Shipping for $300 SpendLEM DK 100 B020, Split Core Hall Effect DC Current Transducer, 50, 75, 100A DC, 0-20mA unipolar output, 20-50VDC supply Compact and versatile Split Core DC current sensor, selectable 50, 75, 100 Amp DC. Choice of output types: 0-20mA, 4-20 mA, 0-5 V or 0-10 V Features Split Core DC Unipolar Measurement 0-20mA voltage output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for busbar/cable up to 21.7mm sqr High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number DK 200 B420 Technology DC Current Transformer with Process Output ROHS Yes Supply Voltage 20-50VDC Nominal Current (RMS + DC) 50,75,100 Amp Selectable Response Time < 100ms Output 0-20mA Analogue Isolation 3kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 2% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
MX11BCC, DC Contactor, Milspec SPST-NO, 150 AMP, 12-48VDC, 12VDC Coil, 122cm Flying leads, IP67, IP69K, 1 x SPST-NC Auxiliary Contact
Free Aus Post Shipping for $300 spendGigavac MX11BCC, DC Contactor, Milspec SPST-NO, 150 AMP, 12-48VDC, 12VDC Coil, 122cm Flying leads, IP67, IP69K, 1 x SPST-NC Auxiliary Contact Features Hermetically Sealed (Patented) rated to 175 Deg C UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 & IP69K Milspec MIL-R-6106 ISO8846 Protection against ignition around flammable gasses CE Approved High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power Ideal for battery powered systems or where low power is needed PWM option provides additional drive control flexibility Built in Coils suppression for all DC Coils Flexible package for installation Chassi level power terminals Salt Fog MIL-STD-810 Specification Gigavac Part Number MX11BCC Main Contact Type SPST-NO Auxiliary Contact Type SPST-NC Coil Voltage 12VDC Load Current 150 Amp Mechanical Life @ 0 Amp 300,000 Cycles Dielectric at Sea Level (leakage <1mA) 1.5kV rms Control Input Terminals 122cm Flying Leads Aux Contact Terminals N/A Special Feature Hermetically Sealed rated to 175 Deg C Mounting Style Panel Mount (M5) Load Voltage Range 12-48VDC Standards MIL-R-6106, IP67, IP69K, ROHS Termination Style M8 Unit Weight 500g Factory Pack Qty 1 Datasheet Product Datasheet
-
E50.N10-703NT0, 70uF 2kVDC, DC Link, H:100mm x D:85mm, Imax = 55 Amp, M12 Mounting Stud, M6 Terminals
Electronicon E50.N10-703NT0, 70uF 2kVDC, DC Link, H:100mm x D:85mm, Imax = 55 Amp, M12 Mounting Stud, M6 Terminals Characteristics and utility 70uF, 2kVDC0.0kvar 20kvar DC Link Film Capacitor Connector type - Stud inserts Indoor mounting Standards IEC 60831-1/2 EN 60831-1/2 Specification Electronicon Part Number E50.N10-703NT0, 70uF 2kVDC Technology DC Link Dimensions H:100mm x D:85mm Standards IEC 60831-1/2, EN 60831-1/2 Voltage 2kVDC Inom 55 Amps Capacitance 70uF Tolerance On Capacitance +/- 10% Lifetime 200,000 Hours Termination Style M6 Screw Inserts Unit Weight 0.7kg Factory Pack Quantity 2 Datasheet Product Catalogue
$255.00
$300.90 inclGST -
M850-LDD, DC kWh Meter 96x96mm, 800VDC, 75mV Shunt Connected, RS485, Lockable,100-240VAC or 100-420VDC
Free Aus Post Shipping for $300 SpendHOBUT M850-LDD, DC kWh Meter 96x96mm, 800VDC, 75mV Shunt Connected, RS485, Lockable,100-240VAC or 100-420VDC 0-10 Amp direct connect, or 50,75mV Shunt Backlit LCD Lockable Optional RS485 communication up to 19,200 bit/s Universal Supply 100-440VAC, or 100-420VDC Accuracy class 1 The meter is intended for measuring, and monitoring DC electrical power networks. The meter records DC power according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands. Features : Measurement of DC kWh Power Optional Pulse Output Graphic LCD with illumination Specification HOBUT Part Number M850-LDD Functions DC Energy Meter Supply Voltage 100-440VAC, or 100-420VDC 0.5VA Nominal Measurement Range 15-150VDC or 30-300VDC, or 80-800VDC Maximum Measurement Range 15-800VDC Nominal Current Input 1A-10A or 50mV/75mV Shunt Infra Red Output N/A Tariff Input N/A (Optional) Accuracy Class 1 (I,U) Mounting Panle Mount Real Time Clock 1min/month (30ppm) Dimensions 96 x 96 x 82mm (2 DIN) Pulse Output Optional Isolation 4kV RS485 Optional Weight 500g Certification CE Factory Pack Qty 1 Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP52 (IP00 for terminals) in compliance with SIST EN 60529:1997 Operating Temperature -20 →+60 °C Datasheet Product Datasheet
-
KNG3047 2295uF 700VDC, DC Link, 120Amp, RRN327/20, H:220mm x D:116mm, M12 Mounting Stud, M6 Terminals
Free Aus Post Shipping for $300 SpendIskra Doo KNG3047 2295uF 700VDC, DC Link, 120Amp, RRN327/20, H:220mm x D:116mm, M12 Mounting Stud, M6 Terminals, MOQ = 50pcs Characteristics and utility 2295uF, 700VDC0.0kvar 20kvar DC Link Film Capacitor Connector type - Stud inserts Indoor mounting Standards IEC 60831-1/2 EN 60831-1/2 Specification Iskra Doo Part Number KNG3047 2295uF 700VDC Technology DC Link Dimensions H:220mm x D:116mm Standards IEC 60831-1/2, EN 60831-1/2 Voltage 700VDC Inom 120 Amps Capacitance 2295uF Tolerance On Capacitance +/- 10% Lifetime 120,000 Hours Termination Style M6 Screw Inserts Unit Weight 3.1kg Factory Pack Quantity 200 Datasheet Product Datasheet
-
E50.R23-225NT1 2190uF 900VDC, DC Link, 90Amp, H:230mm x D:116mm, M12 Mounting Stud, M6 Terminals
E50.R23-225NT1 2190uF 900VDC, DC Link, 90Amp, H:230mm x D:116mm, M12 Mounting Stud, M6 Terminals Characteristics and utility 2190uF, 900VDC0.0kvar 20kvar DC Link Film Capacitor Connector type - Stud inserts Indoor mounting Standards IEC 60831-1/2 EN 60831-1/2 Specification Electronicon Part Number E50.R23-225NT1 2190uF 900VDC Technology DC Link Dimensions H:230mm x D:116mm Standards IEC 60831-1/2, EN 60831-1/2 Voltage 900VDC Inom 80 Amps Capacitance 2190uF Tolerance On Capacitance +/- 10% Lifetime 200,000 Hours Termination Style M6 Screw Inserts Unit Weight 2.6kg Factory Pack Quantity 30 Datasheet Product Catalogue
$523.00
$617.14 inclGST -
MX11CCC, DC Contactor Milspec SPST-NO, 150 AMP, 12-48VDC, 24VDC Coil, 122cm Flying leads, IP67, IP69K, 1 x SPST-NC Auxiliary Contact
Free Aus Post Shipping for $300 spendGigavac MX11CCC, DC Contactor Milspec SPST-NO, 150 AMP, 12-48VDC, 24VDC Coil, 122cm Flying leads, IP67, IP69K, 1 x SPST-NC Auxiliary Contact Features Hermetically Sealed (Patented) rated to 175 Deg C UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 & IP69K Milspec MIL-R-6106 ISO8846 Protection against ignition around flammable gasses CE Approved High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power Ideal for battery powered systems or where low power is needed PWM option provides additional drive control flexibility Built in Coils suppression for all DC Coils Flexible package for installation Chassi level power terminals Salt Fog MIL-STD-810 Specification Gigavac Part Number MX11CCC Main Contact Type SPST-NO Auxiliary Contact Type SPST-NC Coil Voltage 24VDC Load Current 150 Amp Mechanical Life @ 0 Amp 300,000 Cycles Dielectric at Sea Level (leakage <1mA) 1.5kV rms Control Input Terminals 122cm Flying Leads Aux Contact Terminals N/A Special Feature Hermetically Sealed rated to 175 Deg C Mounting Style Panel Mount (M5) Load Voltage Range 12-48VDC Standards MIL-R-6106, IP67, IP69K, ROHS Termination Style M8 Unit Weight 500g Factory Pack Qty 1 Datasheet Product Datasheet
-
MX11CCB, DC Contactor, Milspec SPST-NC, 150 AMP, 12-48VDC, 24VDC Coil, 122cm Flying leads, IP67, IP69K, 1 x SPST-NO Auxiliary Contact
Free Aus Post Shipping for $300 spendGigavac MX11CCB, DC Contactor Military Grade SPST-NC, 150 AMP, 12-48VDC, 24VDC Coil, 122cm Flying leads, IP67, IP69K, 1 x SPST-NO Auxiliary Contact Features Hermetically Sealed (Patented) rated to 175 Deg C UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 & IP69K Milspec MIL-R-6106 ISO8846 Protection against ignition around flammable gasses CE Approved High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power Ideal for battery powered systems or where low power is needed PWM option provides additional drive control flexibility Built in Coils suppression for all DC Coils Flexible package for installation Chassi level power terminals Salt Fog MIL-STD-810 Specification Gigavac Part Number MX11CCB Main Contact Type SPST-NO Auxiliary Contact Type SPST-NO Coil Voltage 24VDC Load Current 150 Amp Mechanical Life @ 0 Amp 300,000 Cycles Dielectric at Sea Level (leakage <1mA) 1.5kV rms Control Input Terminals 122cm Flying Leads Aux Contact Terminals N/A Special Feature Hermetically Sealed rated to 175 Deg C Mounting Style Panel Mount (M5) Load Voltage Range 12-48VDC Standards MIL-R-6106, IP67, IP69K, ROHS Termination Style M8 Unit Weight 500g Factory Pack Qty 1 Datasheet Product Datasheet
-
KNG3047, DC Link 970uF 10% 1000VDC, 80Amp, RRN445_18, H:165mm x D:116mm, M12 Mounting Stud, M6 Terminals, MOQ = 200pcs
Free Aus Post Shipping for $300 SpendIskra Doo KNG3047 970uF 1000VDC, DC Link Capacitor, 80 Amp, MOQ = 200pcs Characteristics and utility 970uF, 1000VDC0.0kvar 20kvar DC Link Film Capacitor Connector type - Stud inserts Indoor mounting Standards IEC 60831-1/2 EN 60831-1/2 Specification Iskra Doo Part Number KNG3047 970uF 1000VDC Technology DC Link Dimensions H:165mm x D:116mm Standards IEC 60831-1/2, EN 60831-1/2 Voltage 1000VDC Inom 80 Amps Capacitance 970uF Tolerance On Capacitance +/- 10% Lifetime 120,000 Hours Termination Style M6 Screw Inserts Unit Weight 2.4kg Factory Pack Quantity 200 Datasheet Product Datasheet
-
E50.N18-624NT0 620uF 900VDC, DC Link, 60Amp, H:181mm x D:85mm, M12 Mounting Stud, M6 Terminals
Electronicon E50.N18-624NT0 620uF 900VDC, DC Link, 60Amp, H:181mm x D:85mm, M12 Mounting Stud, M6 Terminals Characteristics and utility 620uF, 900VDC0.0kvar 20kvar DC Link Film Capacitor Connector type - Stud inserts Indoor mounting Standards IEC 60831-1/2 EN 60831-1/2 Specification Electronicon Part Number E50.N18-624NT0 620uF 900VDC Technology DC Link Dimensions H:181mm x D:85mm Standards IEC 60831-1/2, EN 60831-1/2 Voltage 900VDC Inom 60 Amps Capacitance 60uF Tolerance On Capacitance +/- 10% Lifetime 200,000 Hours Termination Style M6 Screw Inserts Unit Weight 2.5kg Factory Pack Quantity 2 Datasheet Product Catalogue Product Datasheet
$274.60
$324.03 inclGST