Search results for "탤레@todaytarㅡㅣ졸피댐dc시안화칼륨결제방법"
-
BA1-ND21-2, Indicator, 48x24mm, 5VDC, 4-20mA Input, 0-100.0 Display Range
BA1-ND21-2, Indicator, 48x24mm, 5VDC, 4-20mA Input, 0-100.0 Display Range 3.5-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) UL/CE Approved Each unit needs just 40 mm depth panel space EC Compliant Specification Hanyoung Nux Part Number BA1-ND21-2 Control Output 1 (Heat) N/A Control Output 2 (Cool) N/A Input 4-20mA (0-100.0) Alarm N/A Option 1 N/A Mounting Style 48 x 24mm Panel Mount Supply Voltage 5VDC Termination Style Screw Weight 250g Factory Pack Qty 1 ROHS Yes UL Yes CE Yes Datasheet BA1 Series Instruction Manual Free Software Hanyoung Nux TCS Software Hanyoung Nux TCS Software User Manual VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
$69.50
$82.01 inclGST -
DCBM LEM DC kWh Meter, Class B, DIN Rail Mount, 1000VDC, with 400 or 600 Amp Shunt, IP Enabled, OCMF, DHCP Protocols, PTB Approved for Billing Purposes
Free Aus Post Shipping for $300 SpendDCBM LEM DC kWh Meter, Class B, DIN Rail Mount, 1000VDC, with 400 or 600 Amp Shunt, IP Enabled, OCMF, DHCP Protocols. PTB Germany Approved, or MID Approved for Billing 0-400/600 Amp Shunt Measurement Options (Included) Bi-Directional DC Measurement Voltage Measurement Range 150V to 1150V Backlit LCD 12VDC to 24VDC Supply Voltage Meter Operating Temperature -25°C to 70°C Sensor Operating temperature -40°C to 85°C Busbar Operating temperature 105°C max IP Enabled with DHCP 12 - 24VDC Supply Accuracy Class B The meter is intended for measuring, and monitoring DC electrical power and in particular EV charger networks. The meter records DC power according to the principle of fast sampling of voltage and current signals and is approved for billing purposes. A built-in microprocessor calculates measurands. Features : Measurement of DC kWh Power Graphic LCD with illumination Specification LEM Part Number DCBM400, DCBM600 Functions DC Energy Meter Supply Voltage 12-24VDC Nominal Measurement Range 150VDC to 1000VDC Maximum Measurement Range 150 - 1150VDC Nominal Current Input Shunt Provided IP Conficguration Fixed or DHCP Accuracy Class B Mounting Din Rail Mount Real Time Clock NTP Time Sync over HTTPS/REST Dimensions 96 x 96 x 82mm (2 DIN) Pulse Output Optional Isolation 1000VDC Reinforced (4.4kV Vrms Isolation test), PD2, OVC2, Impulse Withstand Voltage 1.2/50uS at 8kV, Altitude = 2000m Comms HTTPS/REST, Ethernet IP, OCMF/SAFE Signed Data Weight 5/6kg Certification PTB, VDE-AR-E-2418-3-100 Factory Pack Qty 1 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20 Operating Temperature -25 →+70°C (Meter), -40 →+85 °C (Busbar 105°C ) Datasheet Product Datasheet Leaflet
-
DTS 1 UNI V2, Dual Digital Time Switch with Daily Weekly, Monthly, and Yearly program, Universal 12-240VAC/DC Power Supply/Control, 1 x 16 Amp SPST CO Relay
Free Aus Post Shipping for $300 SpendIskra Two Pole DTS 1 UNI V2, Dual Digital Time Switch with Daily Weekly, Monthly, and Yearly program, Universal 12-240VAC/DC Power Supply/Control, 1 x 16 Amp SPST CO Relay DTS 2 UNI V2 24-240 V AC/DC - 2 Relay 16A : Multi-range (1 Min - Yearly) Multi-voltage 12 →240 V AC/DC LED status indicator Possibility of external load connection in parallel to the control input Specification Iskra Part Number DTS 1 UNI V2 Function Daily, Monthly, Yearly Time Switch Nominal Voltage 24 → 240 V AC/DC Digital Output 1 x C/O (SPST) (Changeover -Single Pole), 250VAC/DC @ 16 Amp Min Breaking Current 10mA/12VDC Timing Ranges Minutes, Hours, Days, Weeks, Months Minimum Pulse Duration 30ms/100ms with load Repeatability 0.5% Reset Time 120ms Isolation 4kV Repetition Accuracy 0.5% Threshold Adjustment Range 10 → 100 % of the range Termination Style Screw Weight 80g Factory Pack Qty 1 Over Voltage Category 3 in accordance with IEC/EN 60664-1 Pollution Degree 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Mechanical Resistance Immunity to vibrations IEC/EN 60068-2-6, test Fc Immunity to shock IEC/EN 60068-2-27, test Ea Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22 Datasheet User Manual
-
DTS 3 UNI, Digital Time Switch with Daily Weekly, Monthly, and Yearly program, Universal 12-240VAC/DC Power Supply/Control, 16 Amp SPST CO Relay
Free Aus Post Shipping for $300 SpendIskra Single Pole Time Switch with SP-NO/NC Contacts DTS 3 UNI 24-240 V AC/DC - 1 Relay 16A : Multi-range (1 Min - Yearly) Multi-voltage 12 →240 V AC/DC LED status indicator Possibility of external load connection in parallel to the control input Specification Iskra Part Number DTS 3 UNI Function Yearly Time Switch Nominal Voltage 24 → 240 V AC/DC Digital Output 1 x C/O (SPST) (Changeover -Single Pole), 250VAC/DC @ 16 Amp Min Breaking Current 10mA/12VDC Timing Ranges Minutes, Hours, Days, Weeks, Months Minimum Pulse Duration 30ms/100ms with load Repeatability 0.5% Reset Time 120ms Isolation 4kV Repetition Accuracy 0.5% Threshold Adjustment Range 10 → 100 % of the range Termination Style Screw Weight 80g Factory Pack Qty 1 Over Voltage Category 3 in accordance with IEC/EN 60664-1 Pollution Degree 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Mechanical Resistance Immunity to vibrations IEC/EN 60068-2-6, test Fc Immunity to shock IEC/EN 60068-2-27, test Ea Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22 Datasheet Product Datasheet Catalogue
-
DTS 2 UNI V1, Dual Digital Time Switch with Daily Weekly and Monthly Program, Universal 12-240VAC/DC Power Supply/Control, 2 x 16 Amp SPST CO Relays
Free Aus Post Shipping for $300 SpendIskra Single Pole DTS 2 UNI V1, Dual Digital Time Switch with Daily Weekly and Monthly Program, Universal 12-240VAC/DC Power Supply/Control, 2 x 16 Amp SPST CO Relays DTS 2 UNI V1 24-240 V AC/DC - 2 Relay 16A : Multi-range (1 Min - Monthly) Multi-voltage 12 →240 V AC/DC LED status indicator Possibility of external load connection in parallel to the control input Specification Iskra Part Number DTS 2 UNI V1 Function Dual Weekly Time Switch Nominal Voltage 24 → 240 V AC/DC Digital Output 2 x C/O (SPST) (Changeover -Single Pole), 250VAC/DC @ 16 Amp Min Breaking Current 10mA/12VDC Timing Ranges Minutes, Hours, Days, Weeks Minimum Pulse Duration 30ms/100ms with load Repeatability 0.5% Reset Time 120ms Isolation 4kV Repetition Accuracy 0.5% Threshold Adjustment Range 10 → 100 % of the range Termination Style Screw Weight 80g Factory Pack Qty 1 Over Voltage Category 3 in accordance with IEC/EN 60664-1 Pollution Degree 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Mechanical Resistance Immunity to vibrations IEC/EN 60068-2-6, test Fc Immunity to shock IEC/EN 60068-2-27, test Ea Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22 Datasheet Product Datasheet Catalogue