KW62B-With Plate, 130mm long water cooler block (Chiller) for Isolated Modules including IGBT & Diodes and SCR's
M7 Holes for Mounting to Plate.
Replacement to Semikron SKIW900/16
1000 Amp RMS Output using TT500N16KOF
1100 Amp RMS Output using MCC552-16
Copper with copper Binded inlet and outlet, sealed
Pressure Tested to 300 mbar
Nickel plated copper solid construction with aluminium mounting plate
Thermal Rating based on 25 Deg C max inlet water temperature.
Type No
Litres/min
Device
Rcw deg C/W
mbar
kg
KW62B
2
50 x 92
0.055
50
1.2
4
50 x 92
0.042
190
Datasheet
Product Datasheet
Fastron Electronics HF121-12/0.4-40-7%K, 40kVar 400VAC(0.95mH) 7% Detuned Reactor for Power Factor Correction Capacitor Banks, 0.95mH(400VAC) 1.526mH(525VAC)
Specification
Technical Features
HF121-12/0.4-40-7%K
Electrical
Voltage
400V/525V
Network Frequency
50/60Hz
Inductance (mH @ 400VAC)
0.95mH
Inductance (mH @ 525VAC)
1.526mH
Nominal Power
40kvar
Value of p%
7% (189Hz)
Type of Conductor
Aluminium/Copper(optional)
Tolerance L
5%
Linearity (5% L)
1.8 x In
Isolation Voltage
kV
Maximum Room Temperature
-10 to 45 Deg C
Internal isolation
Class F(155°C), Class H (180°C Optional)
Maximum Overload
Permanent
1.17 x In
Temporary
2 x In
Safety
Protection Thermostat
Opens at 90 °C
Degree Protection
IP00
Installation
Indoor
Standards
EN-60289, IEC60076
Weight
25kg
Datasheet
Product Datasheet
Installation Guide
HF121 Series Installation Guide
Fastron Electronics HF121-12/0.4-12.5-7%K, 12.5kVar 400VAC(3.06mH) 7% Detuned Reactor for Power Factor Correction Capacitor Banks, 3.06mH(400VAC) 4.914mH(525VAC)
Specification
Technical Features
HF121-12/0.4-12.5-7%K
Electrical
Voltage
400V/525V
Network Frequency
50/60Hz
Inductance (mH @ 400VAC)
3.06mH
Inductance (mH @ 525VAC)
4.914mH
Nominal Power
12.5kvar
Value of p%
7% (189Hz)
Type of Conductor
Aluminium/Copper(optional)
Tolerance L
5%
Linearity (5% L)
1.8 x In
Isolation Voltage
kV
Maximum Room Temperature
-10 to 45 Deg C
Internal isolation
Class F(155°C), Class H (180°C Optional)
Maximum Overload
Permanent
1.17 x In
Temporary
2 x In
Safety
Protection Thermostat
Opens at 90 °C
Degree Protection
IP00
Installation
Indoor
Standards
EN-60289, IEC60076
Weight
21kg
Datasheet
Product Datasheet
Installation Guide
HF121 Series Installation Guide
H81 Heatsink Profile 72mm x 150mm, Various Lengths cut to order, Milled or Raw Finish
Datasheet
Product Datasheet
Heatsink Data
New Heatsink Data Book
Old Heatsink databook with additional thermal data
H4 Heatsink Profile 33mm x 98mm, Various Lengths cut to order, Milled or Raw Finish
Datasheet
Product Datasheet
Heatsink Data
New Heatsink Data Book
Old Heatsink databook with additional thermal data
Trent HS211A, Panel Mount Heat Sink, 2.7 Deg C per Watt (Heatsink Only). Suitable for 44x 57mm SSR only.
Features
Panel Mount heat sink
Suitable for SSR Mounting
Pre drilled for single or Dual SSR
Panel Mount only
Spec
Fastron Part Number
HS211A
Mounting Type
Panel Mount Only
Suitable SSR Rating
25 Amp
Dimensions (without SSR)
L:80mm x W:50mm x D:50mm
Thermal Impedance
2.7°C/W
Load Current @ 40 Deg C
21 Amp
Load Current @ 50 Deg C
17 Amp
Unit Weight
120g
Factory Pack Qty
10
Datasheet
Product Datasheet
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
HF121-12/0.4-16.7-7%K, 16.7kVar 400VAC 7% Detuned Reactor for Power Factor Correction Capacitor Banks
Specification
Technical Features
HF121-12/0.4-16.7-7%K
Electrical
Voltage
400V/525V
Network Frequency
50/60Hz
Inductance (mH @ 400VAC)
3.678mH
Inductance (mH @ 525VAC)
Nominal Power
16.7kvar
Value of p%
7% (189Hz)
Type of Conductor
Aluminium/Copper(optional)
Tolerance L
5%
Linearity (5% L)
1.8 x In
Isolation Voltage
kV
Maximum Room Temperature
-10 to 45 Deg C
Internal isolation
Class F(155°C), Class H (180°C Optional)
Maximum Overload
Permanent
1.17 x In
Temporary
2 x In
Safety
Protection Thermostat
Opens at 90 °C
Degree Protection
IP00
Installation
Indoor
Standards
EN-60289, IEC60076
Weight
21kg
Datasheet
Product Datasheet
Installation Guide
HF121 Series Installation Guide
Fastron FTCR-16(21)-300-50, Type R Ceramic Thermocouple, 300mm Shaft, Recrystallised Allumina 1400ºC 21x50mm Support Tube, KNE(wire entry:M20x1.5, probe entry: G1/2'') Alminium Die Cast Terminal Head, 0.35 Wire Diameter
Class A Accuracy
50mm Support Tube
0.35mm Internal wire diameter
Low Long Term Drift
Rated for -50 to 1400 Deg C Max
Terminal Head Connection
300(50) or 450(50) Long x 16(21)mm Sheath
Ceramic Sheath with Recrystallaised Allumina
Flange Fitting included for mounting
Specification
Fastron Part Number
FTCR Series
Sensor Type
Type R Thermocouple
No of Wires
2
Probe Length
300mm or 450mm (Includes 50mm Support Tube)
Sheath Thickness
16(21)mm
Sheath Material
Ceramic & Recrystallasied Allumina
Accuracy
Class A
Approvals
CE, ANSI, ROHS
Cable Length
Terminal Head
Terminal Head Type
Die Cast Alloy Terminal Head, , KNE(wire entry:M20x1.5, probe entry: G1/2'')
Temperature Range
-50 to 1400 Deg C
Special Feature
Ceramic
Mounting Style
Flange Fitting Included
Weight
850g
Factory Pack Qty
1
Datasheet
Datasheet
Flange Datasheet
Fan Ring for mounting 120mm fans to H31, or P6Y114 Heatsink
Fan ring is required for optimum air flow 4-5m/s
Generall kept in stock. Otherwise 3-5 days delivery
F923 Series DC Current Transducer with Process Outputs & High and Low Sold State Alarm
Features
Isolated measurement of DC currents using internal Hall effect transducer.
Incorporates an integrated input level display and power supply.
Wide measurement range available
Choice of standard outputs
Wide range isolated DC input supply
DIN Rail mounting
Signal Conditioned DC measurement output
On board bar graph display
User adjustable zero offset and span controls
Zero insertion loss in current measurement path
Earth leakage via differential Ipn for nominal Input ‘01’
Applications
Process control
Transportation
Petrochemical
Industrial
Earth Leakage
Energy Monitoring/Measurement
Automation
Delivery
Delivery in 3-5 days for small qty. Otherwise 4-6 weeks
Specification
Oztherm Part Number
F923-X-XX-DC-XX
Functions
Single Phase DC Current Transducer
Supply Voltage
9-36VDC
Nominal Measurement Range
0-8 Amp (Sensor dependant)
Maximum Measurement Range
8 Amp
Alarm
C/O Relay 2Amp @ 40VDC, 2Amp @ 60VAC
Response Time
250mS
Accuracy @ 25 Deg C
Class 1
Bandwidth
DC - 1kHz
linearity
< 0.15%
Isolation
2.5kV
Comms
N/A
Weight
250g
Enclosure Size
79 x 60 x 85mm
Factory Pack Qty
1
EU Directives
N/A
Safety
Protection Class II
600V rms, installation category II
300V rms, installation category III
Pollution Degree 2 in compliance with SIST EN 61010-1:2002
Enclosure Material
Polyamide non combustable-self-extinguishability, complying with UL 94 V-0
Enclosure Protection
IP40
Shock Withstand
300g 8ms Pulse . 6 Shocks in each of 3 axes
Vibration Withstand
0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
F923 Series DC Current Transducer with Process Outputs & High and Low C/O Alarm
Features
Isolated measurement of DC currents using internal Hall effect transducer.
Incorporates an integrated input level display and power supply.
Wide measurement range available
Choice of standard outputs
Wide range isolated DC input supply
DIN Rail mounting
Signal Conditioned DC measurement output
On board bar graph display
User adjustable zero offset and span controls
Zero insertion loss in current measurement path
Earth leakage via differential Ipn for nominal Input ‘01’
Applications
Process control
Transportation
Petrochemical
Industrial
Earth Leakage
Energy Monitoring/Measurement
Automation
Delivery
Delivery in 3-5 days for small qty. Otherwise 4-6 weeks
Specification
Oztherm Part Number
F923-X-XX-DC-XX
Functions
Single Phase AC Current Transducer
Supply Voltage
9-36VDC
Nominal Measurement Range
0-8 Amp (Sensor dependant)
Maximum Measurement Range
8 Amp
Alarm
C/O Relay 4Amp @ 30VDC, 0.5Amp @ 150VAC
Response Time
250mS
Accuracy @ 25 Deg C
Class 1
Bandwidth
DC - 1kHz
linearity
< 0.15%
Isolation
2.5kV
Comms
N/A
Weight
250g
Enclosure Size
79 x 60 x 85mm
Factory Pack Qty
1
EU Directives
N/A
Safety
Protection Class II
600V rms, installation category II
300V rms, installation category III
Pollution Degree 2 in compliance with SIST EN 61010-1:2002
Enclosure Material
Polyamide non combustable-self-extinguishability, complying with UL 94 V-0
Enclosure Protection
IP40
Shock Withstand
300g 8ms Pulse . 6 Shocks in each of 3 axes
Vibration Withstand
0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
F921 DC Series Current Transducer 100mA to 400 Amp Range with Adjustable High and Low C/O Relay Alarm
Features
Isolated measurement of DC currents using a Hall effect transducer with external aperture.
Incorporates an integrated input level display and power supply.
Wide measurement range available
Choice of standard outputs
Wide range isolated DC input supply
DIN Rail mounting
Signal Conditioned DC measurement output
On board bar graph display
User adjustable zero offset and span controls
Zero insertion loss in current measurement path
Earth leakage via differential Ipn for nominal Input ‘01’
Applications
Process control
Transportation
Petrochemical
Industrial
Earth Leakage
Energy Monitoring/Measurement
Automation
Delivery
Delivery in 3-5 days for small qty. Otherwise 4-6 weeks
Specification
Oztherm Part Number
F921-X-XX-DC-XX-XX
Functions
Single Phase AC Current Transducer
Supply Voltage
9-36VDC
Nominal Measurement Range
0-400 Amp (Sensor dependant)
Maximum Measurement Range
2500 Amp with External Sensor
Alarm
C/O Relay 4Amp @ 30VDC, 0.5Amp @ 150VAC
Response Time
250mS
Accuracy @ 25 Deg C
Class 1
Bandwidth
DC - 1kHz
linearity
< 0.15%
Isolation
2.5kV
Comms
N/A
Weight
250g
Enclosure Size
79 x 60 x 85mm
Factory Pack Qty
1
EU Directives
N/A
Safety
Protection Class II
600V rms, installation category II
300V rms, installation category III
Pollution Degree 2 in compliance with SIST EN 61010-1:2002
Enclosure Material
Polyamide non combustable-self-extinguishability, complying with UL 94 V-0
Enclosure Protection
IP40
Shock Withstand
300g 8ms Pulse . 6 Shocks in each of 3 axes
Vibration Withstand
0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet