FRV 8-02/AD240, 50 to 270VAC Voltage Monitoring Relay, Single Phase Over/Under Voltage Detection, 1 x CO SPDT 10 Amp Contact, Adjustable Timer Delay, Adjustable Upper and Lower Voltage Limits
Fastron FRV 8-02/AD240, 50 to 270VAC Voltage Monitoring Relay, Single Phase Over/Under Voltage Detection, 1 x CO SPDT 10 Amp Contact, Adjustable Timer Delay, Adjustable Upper and Lower Voltage Limits FRV 8 Series serves to monitor under/over voltage in switchboards, protection of devices in single phase 2 wire mains Features Upper and lower level of monitoring voltage Adjustable time delay eliminates short voltage peaks and failures in the main Supply is done from monitored voltage Faulty state is indicated by red LED and by opening of output relay contact Output contact 1 x Changeover / SPDT 10 A /250 V AC1 In case supply voltage falls below 60 %Un (U lower level) relay off immediately opens without delay 1-MODULE, DIN rail mounting Specification Technical Data FRV 8-02 Supply and measuring 50-270VAC Measured voltage 65-260VAC / 50 Hz Level Umax 112.5 % Un Level Umin 83 % Un Burden max. 2 VA Hysteresis 2 % Max. permanent overload 270 VAC/DC Time delay T1 max. 500 ms Time delay T2 adjustable 0.1-10 s Output Number of contacts 1 x changeover/ SPDT (AgNi / Silver Alloy) Rating 10 A / AC1 Breaking capacity 2500 VA / AC1, 240 W / DC Inrush current 10 A Switching voltage 250 V AC1 / 24 V DC Min. breaking capacity DC 500 mW Indication of state red LED Mechanical life 1 x 107 Electrical life (AC1) 1 x 105 Other information Operating temperature -20 ... +55 °C Storage temperature -30 ... +70 °C Electrical strength 4 kV (supply - output) Operating position any Mounting DIN rail EN 60715 Protection degree IP 40 from front panel / IP 10 terminals Overvoltage cathegory III. Pollution degree 2 Max. cable size (mm )2 solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5 Dimensions 90 x 17,6 x 64 mm Weight 69 g Standards EN 60255-6, EN 61010-1, RoHS, CE, CE Datasheet Product Datasheet Fastron Monitoring/Time Relays Catalogue For items in our catalogue which are not listed online please Contact Us for Possible Replacement Application Notes Relay in 3-phase main monitors size of phase voltage. It is possible to set two independent voltage levels and thus it is possible to set two independent voltage levels and monitor e.g. undervoltage and overvoltage independently. In normal state when voltage is within set levels, output relay is closed and red LED shines. In case voltage exceeds or falls below the set levels, output relay opens and red LED shines ( LED indicates faulty state – flashes when timing). In case supply voltage falls below 60 % Un (UOFF lower level)relay immediately opens without delay and faulty state is indicated by red LED.In case timing is in progress and faulty state is indicated, timing is immediately stopped.
$55.00
$64.90 inclGST -
FRV 8-04/265, 127 to 265VAC L-N Voltage Monitoring Relay, 3 Phase 4 Wire Over/Under Voltage Detection, 1 x CO SPDT 8 Amp Contact, Adjustable Timer Delay, Adjustable Upper and Lower Voltage Limits
Fastron FRV 8-04/265, 127 to 265VAC L-N Voltage Monitoring Relay, 3 Phase 4 Wire Over/Under Voltage Detection, 1 x CO SPDT 8 Amp Contact, Adjustable Timer Delay, Adjustable Upper and Lower Voltage Limits FRV 8 Series serves to monitor voltage, phase failure and sequence in switchboards, protection of devices in 3-phase 4 wire mains Features Upper and lower level of monitoring voltage Adjustable time delay eliminates short voltage peaks and failures in the main Supply is done from monitored voltage Faulty state is indicated by red LED and by opening of output relay contact Output contact 1 x Changeover / SPDT 10 A /250 V AC1 In case supply voltage falls below 60 %Un (U lower level) relay off immediately opens without delay FRV8-04/460 - supply from all phases which means that relay is functional also in case when one phase is faulty Variant FRV 8-04/265 - supply L1-N, means that relay monitors also failure of neutral wire 1-MODULE, DIN rail mounting Specification Technical Data FRV 8 Supply and measuring L1, L2, L3 (127,132,138,220,230,240,254,265VAC) Supply terminals L1, L2, L3 Supply/measured voltage 3 x 127-265 V (L-N) / 50 Hz Level Umax 105 - 125 % Un Level Umin 75 - 95 % Un Burden max. 2 VA Hysteresis 2 % Max. permanent overload AC 3 x 265 V Peak overload <1ms AC 3 x 265 V Time delay T1 max. 500 ms Time delay T2 adjustable 0.1-10 s Output Number of contacts 1 x changeover/ SPDT (AgNi / Silver Alloy) Rating 10 A / AC1 Breaking capacity 2500 VA / AC1, 240 W / DC Inrush current 10 A Switching voltage 250 V AC1 / 24 V DC Min. breaking capacity DC 500 mW Indication of state red LED Mechanical life 1 x 107 Electrical life (AC1) 1 x 105 Other information Operating temperature -20 ... +55 °C Storage temperature -30 ... +70 °C Electrical strength 4 kV (supply - output) Operating position any Mounting DIN rail EN 60715 Protection degree IP 40 from front panel / IP 10 terminals Overvoltage cathegory III. Pollution degree 2 Max. cable size (mm )2 solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5 Dimensions 90 x 17,6 x 64 mm Weight 69 g Standards EN 60255-6, EN 61010-1, RoHS, CE, CE Datasheet Product Datasheet Fastron Monitoring/Time Relays Catalogue For items in our catalogue which are not listed online please Contact Us for Possible Replacement Application Notes Relay in 3-phase main monitors size of phase voltage. It is possible to set two independent voltage levels and thus it is possible to set two independent voltage levels and monitor e.g. undervoltage and overvoltage independently. In normal state when voltage is within set levels, output relay is closed and red LED shines. In case voltage exceeds or falls below the set levels, output relay opens and red LED shines ( LED indicates faulty state – flashes when timing). In case supply voltage falls below 60 % Un (UOFF lower level)relay immediately opens without delay and faulty state is indicated by red LED.In case timing is in progress and faulty state is indicated, timing is immediately stopped.
$65.00
$76.70 inclGST -
HO 8-NSM-0000, O/L Hall Effect Current Sensor, 8 Amp, No Aperture, Surface Mount
LEM HO 8-NSM-0000 Series Open Loop AC/DC Hall Effect Sensor Features Open loop multi-range current transducer Multirange through PCB routing Voltage output Single power supply +5 V Overcurrent detect 2.93 × IP N (peak value) Galvanic separation between primary and secondary circuit Low power consumption Compact design for THT PCB mounting Factory calibrated Dedicated parameter settings available on request Advantages Low offset drift Over-drivable Vref Creepage / clearance > 8 mm Fast response Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box Solar inverter on DC side of the inverter (MPPT). Standards IEC 61800-1: 1997 IEC 61800-2: 2015 IEC 61800-3: 2004 IEC 61800-5-1: 2007 IEC 62109-1: 2010 UL 508: 2013. Application Domain Industrial. Specification LEM Part Number HO 8-NSM-0000 Technology Open Loop Hall Effect Aperture N/A ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 8 Amp Measurement Range +/-20 Amp Output 2.5 Vref Isolation 4.3 kV Bandwidth DC-250 kHz Mounting Style Surface Mount Operating Temperature Range -40°C / 105°C Accuracy 1% Termination Style PCB Surface Mount Unit Weight 34g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$11.35
$13.39 inclGST -
FRV 8-04/460, 220-460VAC L-L Voltage Monitoring Relay, 3 Phase Over/Under Voltage Detection, 1 x CO SPDT 8 Amp Contact, Adjustable Timer Delay, Adjustable Upper and Lower Voltage Limits
Fastron FRV 8-04/460, 220-460VAC L-L Voltage Monitoring Relay, 3 Phase Over/Under Voltage Detection, 1 x CO SPDT 8 Amp Contact, Adjustable Timer Delay, Adjustable Upper and Lower Voltage Limits FRV 8 Series serves to monitor voltage, phase failure and sequence in switchboards, protection of devices in 3-phase mains Features Upper and lower level of monitoring voltage Adjustable time delay eliminates short voltage peaks and failures in the main Supply is done from monitored voltage Faulty state is indicated by red LED and by opening of output relay contact Output contact 1 x Changeover / SPDT 10 A /250 V AC1 In case supply voltage falls below 60 %Un (U lower level) relay off immediately opens without delay FRV 8-04/460 - supply from all phases which means that relay is functional also in case when one phase is faulty Variant FRV 8-04/265 - supply L1-N, means that relay monitors also failure of neutral wire 1-MODULE, DIN rail mounting Specification Technical Data FRV 8 Supply and measuring L1, L2, L3 (220,230,240,380,400,415,440,460VAC) Supply terminals L1, L2, L3 Supply/measured voltage 3 x 220-460 V / 50 Hz Level Umax 105 - 125 % Un Level Umin 75 - 95 % Un Burden max. 2 VA Hysteresis 2 % Max. permanent overload AC 3 x 460 V Peak overload <1ms AC 3 x 500 V Time delay T1 max. 500 ms Time delay T2 adjustable 0.1-10 s Output Number of contacts 1 x changeover/ SPDT (AgNi / Silver Alloy) Rating 10 A / AC1 Breaking capacity 2500 VA / AC1, 240 W / DC Inrush current 10 A Switching voltage 250 V AC1 / 24 V DC Min. breaking capacity DC 500 mW Indication of state red LED Mechanical life 1 x 107 Electrical life (AC1) 1 x 105 Other information Operating temperature -20 ... +55 °C Storage temperature -30 ... +70 °C Electrical strength 4 kV (supply - output) Operating position any Mounting DIN rail EN 60715 Protection degree IP 40 from front panel / IP 10 terminals Overvoltage cathegory III. Pollution degree 2 Max. cable size (mm )2 solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5 Dimensions 90 x 17,6 x 64 mm Weight 69 g Standards EN 60255-6, EN 61010-1, RoHS, CE Datasheet Product Datasheet Fastron Monitoring/Time Relays Catalogue For items in our catalogue which are not listed online please Contact Us for Possible Replacement Application Notes Relay in 3-phase main monitors size of phase voltage. It is possible to set two independent voltage levels and thus it is possible to set two independent voltage levels and monitor e.g. undervoltage and overvoltage independently. In normal state when voltage is within set levels, output relay is closed and red LED shines. In case voltage exceeds or falls below the set levels, output relay opens and red LED shines ( LED indicates faulty state – flashes when timing). In case supply voltage falls below 60 % Un (UOFF lower level)relay immediately opens without delay and faulty state is indicated by red LED.In case timing is in progress and faulty state is indicated, timing is immediately stopped.
$65.00
$76.70 inclGST -
4410.0131 T12-211S-8, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 8 Amp, 1kA, Threaded neck type, Reset Type, Quick Connect Terminals, w/ Auxiliary Contact
Schurter, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 8 Amp, 1kA, Threaded neck type, Reset Type, Quick Connect Terminals, w/ Auxiliary Contacts 4410.0131 T12-211S-8 Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of Electrical Appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole with Auxiliary Contact- Motors Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect with Auxiliary Contact 1kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 500 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4410.0131 T12-211S-8 Functions 1 Pole Thermal Circuit Breaker with Aux Contact, Reset Type Nominal Voltage 240VAC @ 50Hz or 28VDC Nominal Current Range 8 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 4kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$58.70
$69.27 inclGST -
81921701, Position Detector, 3/2 Normally Closed, Lever, Roller, 1 ~ 116PSI (0.1 ~ 8 bar), Diameter 0.106" (2.70mm), Push-In Connection for Tubing 5/32" (4.00mm) Dia, Operating Force 18N Chassis Mount
81921701, Position Detector, 3/2 Normally Closed, Lever, Roller, 1 ~ 116PSI (0.1 ~ 8 bar), Diameter 0.106" (2.70mm), Push-In Connection for Tubing 5/32" (4.00mm) Diameter, Operating Force 18N Chassis Mount Position Detector 3/2 Normally Closed, Lever, Roller 1 ~ 116PSI (0.1 ~ 8 bar), Diameter 0.106" (2.70mm) Push-In Connection for Tubing 5/32" (4.00mm) Dia Operating Force 18N Chassis Mount Datasheet Product Datasheet
$89.00
$105.02 inclGST -
HO 8-NSM-0000 Kit 5P, Evaluation Kit 5pcs with PCB
Free Aus Post Shipping for $300 SpendLEM HO 8-NSM-0000 Kit 5P Series Open Loop AC/DC Hall Effect Sensor Features Open loop multi-range current transducer Multirange through PCB routing Voltage output Single power supply +5 V Overcurrent detect 2.93 × IP N (peak value) Galvanic separation between primary and secondary circuit Low power consumption Compact design for THT PCB mounting Factory calibrated Dedicated parameter settings available on request Advantages Low offset drift Over-drivable Vref Creepage / clearance > 8 mm Fast response Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box Solar inverter on DC side of the inverter (MPPT). Standards IEC 61800-1: 1997 IEC 61800-2: 2015 IEC 61800-3: 2004 IEC 61800-5-1: 2007 IEC 62109-1: 2010 UL 508: 2013. Application Domain Industrial. Specification LEM Part Number HO 8-NSM-0000 Technology Open Loop Hall Effect Aperture N/A ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 8 Amp Measurement Range +/-20 Amp Output 2.5 Vref Isolation 4.3 kV Bandwidth DC-250 kHz Mounting Style Surface Mount Operating Temperature Range -40°C / 105°C Accuracy 1% Termination Style PCB Surface Mount Unit Weight 34g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
VA6520, Infra Red Thermometer /Probe Range -50 ~ 20 Deg C / -20 Deg C (-58 Deg F to ~932 Deg F). TAMB Measurement 0~50 Deg C. Resolution 0.1 Deg C D:S Ratio 8:1. Up to 1.5m Distance. OL or -OL Overrange. Fixed Emissivity 0.95
Free Aus Post Shipping for $300 SpendVA6520, Infra Red Thermometer /Probe Range -50 ~ 20 Deg C / -20 Deg C (-58 Deg F to ~932 Deg F). TAMB Measurement 0~50 Deg C. Resolution 0.1 Deg C D:S Ratio 8:1. Up to 1.5m Distance. OL or -OL Overrange. Fixed Emissivity 0.95 Features Portable /Battery Powered 3 x AAA Range -50 ~ 20 Deg C +/-5 Deg C / -20 Deg C ~5 Reading Deg C 1.5% + 2 Deg C (-58 Deg F to ~932 Deg F) TAMB Measurement 0~50 Deg C Resolution 0.1 Deg C D:S Ratio 8:1 Up to 1.5m Distance OL or -OL Overrange Fixed Emissivity 0.95 1 second Response Time 8-14um Spectral Response 1mW laser Single Laser Measurement Datasheet Datasheet
-
FTCK-5-EGTD-3000-1/8N Vehicle Exhaust Sensor, Type K MIMS Class B, 1/8" NPT SS304 80mm x 50mm x 4.8mm Probe w/ 3000mm Screened Teflon/Braided SS cable, -20 to 600 Deg C
Free Aus Post Shipping for $300 SpendFastron FTCK-5-EGTD-3000-1/8N Vehicle Exhaust Sensor, Type K MIMS Class B, 1/8" NPT SS304 80mm x 50mm x 4.8mm Probe w/ 3000mm Screened Teflon/Braided SS cable, -20 to 600 Deg C 1/8" NPT Compression Fitting SS304 Durability Class A Accuracy Teflon SS Braided Cable Low Long Term Drift Rated for -20 to 600 Deg C Max 80mm x 50mm x 4.8mm MIMS Specification Fastron Part Number FTCK-5-EGTD-3000-1/8N Sensor Type Type K Thermocouple No of Wires 2 Probe Length 80 x 50mm Sheath Thickness 4.8mm Sheath Material SS304 Accuracy Class A Approvals N/A Cable length 3 Meters Cable Type Teflon/Braided Stainless Steel with Spring Bayonet Cap Temperature Range -20 to 600 Deg C Special Feature Quick Release Fitting, Strain Relief Spring Cable Mounting Style Quick Release Fitting Weight 300g Factory Pack Qty 1 Datasheet Datasheet
-
GO 8-SME/SP4, O/L Hall Effect Current Sensor, 8 Amp, SMD, 3.3V Supply
GO 8-SME/SP4, O/L Hall Effect Current Sensor with evaluation PCB, 8 Amp Features Hall effect measuring principle Galvanic separation between primary and secondary circuit Insulated test voltage 3000 V RMS Low power consumption Extremely low profile Single power supply +5 V Double overcurrent detection Fixed offset & sensitivity Response time 2 µs. Advantages Small size and space saving High immunity to external interference High insulation capability Industrial. Low electrical resistance (0.75 mΩ) No magnetic hysteresis Robust against external fields and cross-talk. Applications Appliances Small drives HVAC Solar E-Bikes Standards IEC 62109-1: 2010 IEC 60950-1: 2005 IEC 61800-5-1: 2007 UL 1577: 2014. Application Domains Industrial Specification LEM Part Number GO 8-SME/SP4 Technology Closed Loop Hall Effect ROHS Yes Supply Voltage 3.3 VDC Load Current (RMS + DC) 4 Amp Overload Capability +/-200 Amp Output 2.5 Vref Isolation 2.5 kV Bandwidth DC-300 kHz Mounting Style Surface Mount - SOIC 8 Pin Operating Temperature Range -40°C / 125°C Accuracy 2% Termination Style N/A Unit Weight 10g Factory Pack Quantity 150 Datasheet Product Datasheet
$4.90
$5.78 inclGST -
VA6512, Infra Red Thermometer /Probe Range -30 ~ 0 Deg C / 0 Deg C ~270 Reading Deg C . Resolution 0.1 Deg C D:S Ratio 6:1. Up to 1m Distance. OL or -OL Overrange. Fixed Emissivity 0.95, 8-14um Spectral Response. 1mW laser, Laser + Probe
Free Aus Post Shipping for $300 SpendVA6512, Infra Red Thermometer /Probe Range -30 ~ 0 Deg C / 0 Deg C ~270 Reading Deg C . Resolution 0.1 Deg C D:S Ratio 6:1. Up to 1m Distance. OL or -OL Overrange. Fixed Emissivity 0.95, 8-14um Spectral Response. 1mW laser, Laser + Probe Features Portable /Battery Powered 3 x AAA Range -30 ~ 0 Deg C +/-4 Deg C / 0 Deg C ~270 Reading Deg C 1.5% +/-2 Deg C (-22 Deg F to ~518 Deg F) Resolution 0.1 Deg C D:S Ratio 6:1 Up to 1m Distance OL or -OL Overrange Fixed Emissivity 0.95 1 second Response Time 8-14um Spectral Response 1mW laser Laser or Probe Measurement (-50 Deg C ~ -20 Deg C +/-1.5% +/-1 Deg C 0.1 Deg C Resolution/ -20 Deg C ~ 200 Deg C +/-1% +/- 1 Deg C 0.1 Deg C Resolution / 200 Deg C ~ 270 Deg C +/-2% +-4 Deg C 1 Deg C Resolution Datasheet Datasheet
-
FRV 8-06/460, 220-460VAC L-L Voltage Monitoring Relay, 3 Phase Over/Under Voltage Detection, 1 x CO SPDT 8 Amp Contact, Fixed 2s Timer Delay, Adjustable Upper and Lower Voltage Limits, Adjustable Asymmetry
Free Aus Post Shipping for $300 SpendFastron FRV 8-06/460, 220-460VAC L-L Voltage Monitoring Relay, 3 Phase Over/Under Voltage Detection, 1 x CO SPDT 8 Amp Contact, Fixed 2s Timer Delay, Adjustable Upper and Lower Voltage Limits, Adjustable Asymmetry FRV 8 Series serves to monitor voltage, phase failure and sequence in switchboards, protection of devices in 3-phase mains Features Upper and lower level of monitoring voltage Asymmetry Adjustable time delay eliminates short voltage peaks and failures in the main Supply is done from monitored voltage Faulty state is indicated by red LED and by opening of output relay contact Output contact 1 x Changeover / SPDT 10 A /250 V AC1 In case supply voltage falls below 60 %Un (U lower level) relay off immediately opens without delay FRV 8-04/460 - supply from all phases which means that relay is functional also in case when one phase is faulty Variant FRV 8-06/265 - supply L1-N, means that relay monitors also failure of neutral wire 1-MODULE, DIN rail mounting Specification Technical Data FRV 8 Supply and measuring L1, L2, L3 (220,230,240,380,400,415,440,460VAC) Supply terminals L1, L2, L3 Supply/measured voltage 3 x 220-460 V / 50 Hz Level Umax 105 - 125 % Un Level Umin 75 - 95 % Un Burden max. 2 VA Hysteresis 2 % Max. permanent overload AC 3 x 460 V Peak overload <1ms AC 3 x 500 V Time delay T1 max. 500 ms Time delay T2 adjustable 0.1-10 s Output Number of contacts 1 x changeover/ SPDT (AgNi / Silver Alloy) Rating 10 A / AC1 Breaking capacity 2500 VA / AC1, 240 W / DC Inrush current 10 A Switching voltage 250 V AC1 / 24 V DC Min. breaking capacity DC 500 mW Indication of state red LED Mechanical life 1 x 107 Electrical life (AC1) 1 x 105 Other information Operating temperature -20 ... +55 °C Storage temperature -30 ... +70 °C Electrical strength 4 kV (supply - output) Operating position any Mounting DIN rail EN 60715 Protection degree IP 40 from front panel / IP 10 terminals Overvoltage cathegory III. Pollution degree 2 Max. cable size (mm )2 solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5 Dimensions 90 x 17,6 x 64 mm Weight 69 g Standards EN 60255-6, EN 61010-1, RoHS, CE Datasheet Product Datasheet Fastron Monitoring/Time Relays Catalogue For items in our catalogue which are not listed online please Contact Us for Possible Replacement Application Notes Relay in 3-phase main monitors size of phase voltage. It is possible to set two independent voltage levels and thus it is possible to set two independent voltage levels and monitor e.g. undervoltage and overvoltage independently. In normal state when voltage is within set levels, output relay is closed and red LED shines. In case voltage exceeds or falls below the set levels, output relay opens and red LED shines ( LED indicates faulty state – flashes when timing). In case supply voltage falls below 60 % Un (UOFF lower level)relay immediately opens without delay and faulty state is indicated by red LED.In case timing is in progress and faulty state is indicated, timing is immediately stopped.