Rishabh Rish SIGMA 75 CTR5+5/5.CL0.5.10VA Summation Current Transformer
Features
DIN Rail Mounting Clip Included
Built In Sealable Terminal Covers
Mounting Feet Supplied
Narrow Width (30mm)
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
Rish SIGMA 75 CTR5+5/5.CL0.5.10VA
Technology
AC Current Transformer
Ratio
5+5/5
VA Rating
10VA Class 0.5
Accuracy Class
Class 0.5
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
8 Amp
Termination Style
Screw
Unit Weight
500g
Factory Pack Qty
5
Datasheet
Product Datasheet
F135-4-75D, Panel Mount 3 Phase Solid State Contactor, 75 Amp per Phase, 70-480VAC Switching, 4-32VDC Control Contactor Style Modules
Ratings from 13A to 240 Amp per phase @ 30-480 VAC
Thermal Overload Detection (via Bimetal Thermal Switch)
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Optional Fuses(Loose), Varistors(mounted) or 240VAC Snubber(mounted)
Specification
Part Number
F135-4-75D
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
3-32VDC
Load Current
75 Amp (rms) per Phase @ 50 Deg C
Special Feature
N/A
Mounting Style
Panel Mount
Load Voltage Range
70-480VAC
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Screw Terminals
Factory Pack Qty
1
Dimensions and Fuse Kits
Part Number
Approximate Dimensions
Weight
Panel Mount Fuse Kits
DIN Rail Mount Fuse Kits
F135-4-13A(D)
L:115 x W:125 x D:95mm (Figure 1)
0.75kg
20-30 Amp 660VAC Fuse Kit
Trent 25 Amp Cartridge Fuse
F135-4-25A(D)
L:155 x W:125 x D:185mm (Figure 5)
3.2kg
20-50 Amp 660VAC Fuse Kit
Trent 40 Amp Cartridge Fuse
F135-4-50A(D)
L:255 x W:125 x D:185mm (Figure 6)
4.5kg
20-50 Amp 660VAC Fuse Kit
Trent 63 Amp Cartridge Fuse
F135-4-75A(D)
L:255 x W:125 x D:185mm (Figure 6)
4.5kg
80-120 Amp 660VAC Fuse Kit
Trent 80 Amp Cartridge Fuse
F135-4-90A(D)
L:255 x W:125 x D:185mm (Figure 6)
4.5kg
80-120 Amp 660VAC Fuse Kit
Trent 125 Amp Cartridge Fuse
F135-4-120A(D)
L:255 x W:125 x D:195mm (Figure 6)
4.5kg
80-120 Amp 660VAC Fuse Kit
N/A
F135-4-180A(D)
L:335 x W:125 x D:195mm (Figure 7)
5.5kg
120-180 Amp 660VAC Fuse Kit
N/A
F135-4-240A(D)
L:335 x W:125 x D:195mm (Figure 8)
6.8kg
210-240 Amp 660VAC Fuse Kit
N/A
??
If you need??a fan Control Relay you can find it here in our store.
Datasheet
F115_135 Series Datasheet
Current Transducer, AT-DV7-D-1, AC Voltage Transducer, 600VDC, 22-60VAC/DC Aux, 4-20mA output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) or 0-10V/0-5V (For Direct Voltage Type)
Each unit needs just 50mm x 120mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
AT-DV7-D-1
Control Output
4-20mA
Input
0-600VDC
Over Range
x 1.2
Operating Temperature
0 - 60°C
Load Voltage
22-60VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
F135-4-50D, Panel Mount 3 Phase Solid State Contactor, 50 Amp per Phase, 70-480VAC Switching, 4-32VDC Control Contactor Style Modules
Ratings from 13A to 240 Amp per phase @ 30-480 VAC
Thermal Overload Detection (via Bimetal Thermal Switch)
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Optional Fuses(Loose), Varistors(mounted) or 240VAC Snubber(mounted)
Specification
Part Number
F135-4-50D
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
3-32VDC
Load Current
50 Amp (rms) per Phase @ 50 Deg C
Special Feature
N/A
Mounting Style
Panel Mount
Load Voltage Range
70-480VAC
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Screw Terminals
Factory Pack Qty
1
Dimensions and Fuse Kits
Part Number
Approximate Dimensions
Weight
Panel Mount Fuse Kits
DIN Rail Mount Fuse Kits
F135-4-13A(D)
L:115 x W:125 x D:95mm (Figure 1)
0.75kg
20-30 Amp 660VAC Fuse Kit
Trent 25 Amp Cartridge Fuse
F135-4-25A(D)
L:155 x W:125 x D:185mm (Figure 5)
3.2kg
20-50 Amp 660VAC Fuse Kit
Trent 40 Amp Cartridge Fuse
F135-4-50A(D)
L:255 x W:125 x D:185mm (Figure 6)
4.5kg
20-50 Amp 660VAC Fuse Kit
Trent 63 Amp Cartridge Fuse
F135-4-75A(D)
L:255 x W:125 x D:185mm (Figure 6)
4.5kg
80-120 Amp 660VAC Fuse Kit
Trent 80 Amp Cartridge Fuse
F135-4-90A(D)
L:255 x W:125 x D:185mm (Figure 6)
4.5kg
80-120 Amp 660VAC Fuse Kit
Trent 125 Amp Cartridge Fuse
F135-4-120A(D)
L:255 x W:125 x D:195mm (Figure 6)
4.5kg
80-120 Amp 660VAC Fuse Kit
N/A
F135-4-180A(D)
L:335 x W:125 x D:195mm (Figure 7)
5.5kg
120-180 Amp 660VAC Fuse Kit
N/A
F135-4-240A(D)
L:335 x W:125 x D:195mm (Figure 8)
6.8kg
210-240 Amp 660VAC Fuse Kit
N/A
??
If you need??a fan Control Relay you can find it here in our store.
Datasheet
F115_135 Series Datasheet
Fastron FYCF-3, Three Phase Voltage Control SCR Trigger Module, 4-20mA,2-10V,1-5V,5K POT Input, 200-450VAC, 12VDC Aux Supply. Can Replace Semikron Semi-PCM 2
4-20mA,2-10V, 1-5V or 10K POT Proportional Phase Control Input
Suitable for SCR Blocks up to 3000 Amp
Instantaneous turn-on output
CE Approval (Pending)
Can Replace Semikron Semi-PCM 2 SKPC200 for most applications
Specification
Fastron part Number
FYCF-3
Switching Type
Phase Angle (Random Crossing)
Control Voltage
4-20mA,2-10V,1-5V,10K POT Proportional Input
Load Current
Based on SCR Stack
Special Feature
3 Phase Proportional Controller + SSR/3 Phase Voltage Regulator
Mounting Style
Panel Mount
Load Voltage Range
200-450VAC +10%
Termination Style
Barrier Strip Screw
Dimensions
105 x 90 x 40mm
Unit Weight
400g
Factory Pack Qty
20
Datasheet and User Manual
FYCF-3
Fastron Electronics Fast ONE SVG 35kvar-400V-4W, 35kVar Static Var Generator(SVG)/Inverter for Reactive Power Correction, 3 Phase 4 Wire, Wall Mounted
For Automatic Switching of Power Factor Correction Capacitors according to changing site conditions.
Features
Automatic Power Factor Correction up to Cos φ = 0.99
Overtemperature Alarm
Optional RS485 Comms
IEC 654-1, UL Approved
3 Year Fastron Electronics Warranty
Modular Construction for Rack or Wall Mount Installtions
Perfect for Residential Applications
Stack multiple modules for larger Power Factor Correction Requirements
Specification
Fastron Part Number
Fast ONE SVG 35kvar-400V-4W
Mounting
Wall Mounted
Function
Reactive Power Correction
Configuration
4 Wire
Nominal Voltage (Un)
400VAC Line to Line 50Hz
Switch Delay Time
Instant Correction/Inverter Based
Desired Power Factor
0.99 IND - 0.99 CAP
LCD Display Accuracy
Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1
Phase Angle Error
+/- 1% at I > 3% of range
Comms
RS485 (Optional)
Termination Style
Screw
Dimensions
486x183x550mm
Weight
45kg
Certification
EN 61000-6-4:2007+A1:2011
EN 61000-6-2:2005
EN 61000-3-2:2014
EN 61000-3-3:2013+A1:2019
Factory Pack Qty
1
Material of housing
PC/ABS Unflammable, according to UL 94 V-0, & Stainless Steel Painted RAL 1013
Enclosure protection
IP21
Safety
According to EN 61 010-1, installation category III Pollution degree 2
Operating Temperature
-20...55 °C
Datasheet
User Manual
Datasheet
SI01-5H55H00000000(SI-101-4-2-H)
, Signal Isolator/Conditioner, 0-10V input, 85-300VAC/DC aux, 4-20mA output, Fixed zero and span, Fixed zero and span
Fixed Zero and Span Setting
150mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
SI01-5H55H00000000
Control Output
4-20mA
Input
0-10V
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
85-300VAC/DC
Span Adjustment Range
Fixed
Zero Adjustment Range
Fixed
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics GA5-D-V7-D-N, 96x48mm 5 DIGIT Digital Ammeter 0-600VDC input, 100-240VAC/DC Supply
Adjustable Zero and Span Setting
Adjustable Display Scaling
Large 5 Digit 20.3mm (8 Inch) LED Display
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 96 x 48mm Panel Space
60mm Depth
Specification
Fastron Electronics Part Number
GA5-D-V7-D-N
Conditioner Output
N/A
Input
0-600VDC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
22-60VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
96 x 48mm Panel Mount (60mm depth)
Case Material
PC - UL 94 V0
Weight
320g
Factory Pack Qty
1
Datasheet
Product Datasheet
Application Notes
Panel Meters Blog Articles
Fastron FY3 Series, Phase/Burst Controller for Primary Control of Transformer (Phase angle mode only), Voltage/Current/Power Limit Modes, For 3 Wire or 4 Wire Loads, 400VAC, 50 Amps per Phase @ 50 Deg C, Modbus RTU
Features
Phase Angle, Distributed Burst, and Time Proportional Burst Control Functions
Made in China, Low cost
3 Phase, or Single Phase, Angle/Burst Controller
4-20mA/0-10V/1-5V input Proportional Control
Fully enclosed IP20
Phase Angle or Burst switching
Aluminium Frame
Removable Cover
Modbus RTU
Applications
Electrical Ovens, Kilns, or Furnaces
HVAC Heaters
Controlled Power Applications
Electric Boilers
Brewery Heating
Industrial Light Dimming
Suitable for HVAC or Industrial Environments
Specification
Fastron Part Number
FY3 Series
Rated Operating Temperature
50°C
SCR Configuration
3 Phase AC Switch
Control Voltage
4-20mA/0-10V/0-5V
Load Current
50-500 Amps Per Phase @ 50 Deg C
Derating
2% per 1 Deg C (approx)
Control Range
0-100%
Alarms
1 x NO Relay Contacts
Special Feature
Internal Fuse, Current Limit, Power Limit
Comms
Modbus RTU
Mounting Style
Panel Mount
Switching Voltage Range
400VAC +/-10%
Supply Voltage
230VAC +/-10%
Soft Start
N/A
Termination Style
Screw
Unit Weight
4kg (6kg Packed)
Factory Pack Qty
1
Technical Docs
Brochure
User Guide
Modbus Protocol Guide
Modbus Register Map
Video for How to Set Current/Voltage/Power limit
LEM ART-B22-D125-SP3 + AI-PMUL, Single Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 12.5cm Diameter
The universal Rogowski coil integrator AI-PMUL complements LEM’s flexible clip-around coil ART and ARU range. The design is based on digital processing to give combined dynamic range, accuracy and versatility of use. It offers a wide range of output signals both RMS and instantaneous. AI-PMUL is DIN rail mounted and can be stacked for multiphase application without spacing thanks to its low power dissipation.
Input signal
Accuracy Class 1 (IEC 61869-2) [1].
Linearity error ≤ 0.10 %. Protection degree IP2X.
35 mm DIN rail mounted.
Push-in terminals.
4 selectable true RMS output signals: 0…20 mA, 4…20 mA, 0…5 V, 0…10 V.
2 selectable instantaneous output signals: 225 mV, 333 mV.
6 selectable sensitivities depending on Rogowski coil: 22.5, 70, 80, 85, 100, 120 mV/kA at 50 Hz.
12 selectable ranges: 100, 200, 300, 400, 500, 600, 800, 1000, 1500, 2000, 4000, 5000 A.
Ambient operating temperature −25...+70 °C.
Advantages
Compact design for DIN rail assembly
High accuracy Class 1 (IEC 61869-2)
Setup by user via Select / Edit buttons
Clear status indication via bi-color led
Applications
MV/LV substations on LV side: Transformer Condition Monitoring
Power metering: current measurement for active power calculation
Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation
Power quality monitoring: electrical loads and distribution system equipment
Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault
Remote Terminal Units (RTU)
Phasor Measurement Units (PMU)
Standards
IEC 61010-1: 2010
UL
EMC: IEC 61326-1:2012
Options
Cross Power Plug-in: side contacts to stack up to 3 Integrator modules and use only one power supply.
Specification
LEM Part Number
AI-PMUL + ART-B22-D125-SP3
Function
Single Phase AC Current Measurement
Measuring Range
Selectable 5000,4000,2000,1500,1000,800,600,500,400,300,200,100Amp
Sensitivity
Selectable 22.5,70,80,85,100,120mV/kA @ 50 Hz
Output
Selectable; Signal Conditioned True RMS 0-20mA, True RMS 4-20mA, True RMS 5V, True RMS 10V or 225mV, 333mV Direct Output (1 Amp output coming soon)
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
10-32VDC
Accuracy
1% from 25 to 5000 Amp
Current Consumption
100mA (max)
Dimensions
100mm x 78mm x 15mm (Integrator), 12.5cm Diameter (Coils)
Mounting
Din Rail Mount
Integrator to Coil cable
3M Twisted and Screened
Integrator to Meter cable
User Supplied Shielded cable 1.5mm sqr, up to 6m long
Operating Temperature
-25°C - 70°C
Storage Temperature
-45°C to 80°C
Isolation (50Hz, 1 min)
1.5kV
True RMS Response Time
160-190ms
Termination Style
Push-in for 1.5mm sqr wire
Weight
58g
Factory Pack Qty
1
Certifications
UL, ROHS
Datasheet
AI-PMUL Datasheet
ART Series Datasheet
Application Notes
User Notice
1) The Rogowski coil can measure any primary current as there is no saturation effect.
2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts)
3) Frequency bandwidth and phase shift modelling schematic can be provided on request.
4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer)
5) Considering a primary conductor of at least ⌀ 15 mm, perpendicular and in contact with the Rogowski coil.
6) Considering an external conductor of at least ⌀ 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.
Iskra Doo K08M-10-24VAC Miniature Contactor 240/400/500/690V, with 24VAC Control Voltage, 4 Pole 4 x NO, Nominal Current = 15.5 Amps
Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity.
Features :
High contact reliability at low voltages
High electrical and mechanical endurance and high switching capacity
Four and Three-pole contactors
Optional auxiliary contacts
Ratings from 6 Amp to 1000 Amp
UL, CSA Approved
Advantages :
Saves costs of expensive replacement
Long electrical life
Reduces watt losses during “ON” condition, saves energy
High safety
No risk of dangerous voltage
Less maintenance and downtime
Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz
Specification
Iskra Doo Part Number
K08M-10-24VAC
Functions
4 Pole Contactor 4 x NO
Nominal Voltage
230/400/500/690VAC @ 50/60Hz
Current Carrying Capacity as per UL
15.5 Amp Continuous @ 55 Deg C
Auxiliary Contacts
Optional
Trip Delay Time
2-10ms
Electrical Life
200,000 Ops
Operating Temperature
-25 to 40 Deg C
Mechanical Operations
10.000,000 Ops
Control Voltage
24VAC
Power Dissipation
0.36W
Approvals
UL, CSA, CE
Standards
IEC/EN 60947-4-1, AS/NZ 61009-1
Weight
200g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Contactor Catalogue
Iskra Contactor Catalogue