Fastron Electronics SCT-F10-5, 5 Amp, 0.333v Class 1 Series Current Transformer, Equivalent to SCT-0400-10 (CE Approval, No UL approval)
Features
Quick Release Split Core System
Cable Mount
0.333v Output
Self Powered
Rated System Voltage 0.60/3kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F10-5
Technology
Split Core AC Current Transformer
Ratio
5/0.333v
Aperture Size
ø 8 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333v (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
5Amp x 1.2
Termination Style
0.5M Flying Leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
UL Approved Version
SCT-0400-05
Fastron Electronics SCT-F36-5, 0.333V, 5Amp measurement Split Core CT's Class 1, 36mm Aperture
Features
Quick Release Split Core System
Cable Mount
0.333V Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F36-5
Technology
Split Core AC Current Transformer
Ratio
5/0.333V
Aperture Size
ø 35 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333V (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
5Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
400g
Factory Pack Qty
9
Datasheet
Product Datasheet
Stocked Split Core CT's Listing
Application Notes
Installation Guide
Types of Current Transformers - Blog
Cable Losses and CT's
High Accuracy or High Burden Requirements for CT's
Xmer CT Split 93/30SC 150/5 Class 1 1.75VA, 23 x 33mm Aperture
Features
Quick Release Split Core System
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
Xmer CT Split 93/30SC 150/5 Class 1 1.75VA
Technology
Split Core AC Current Transformer
Ratio
150/5
Aperture Size
23 x 33mm
VA Rating
1.75VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
150Amp x 1.2
Termination Style
Screw
Unit Weight
600g
Factory Pack Qty
9
Datasheet
Product Datasheet
Rish Xmer 74-20 (45) 100/5 Class 0.2S, 1.5VA, 21mm Aperture
Features
High Accuravcy Class 0.2S
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
Rish Xmer 74-20 (45) 100/5 Class 0.2S
Technology
AC Current Transformer
Ratio
800/5
Aperture Size
21x11mm
VA Rating
1.5VA
Accuracy Class
Class 0.2S
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-25°C / 40°C
Continuous Current (max)
Ipn x 1.2
Termination Style
Screw
Unit Weight
500g
Factory Pack Qty
9
Datasheet
Product Datasheet
Rishabh Xmer CT Split 155/80 1200/5 Class 1 30VA Series Current Transformer
Features
Quick Release Split Core System
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
Rish Xmer 155/80 1200/5 SCCT Class 1 30VA
Technology
Split Core AC Current Transformer
Ratio
1200/5
Aperture Size
85 x 125mm
VA Rating
30VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
1200Amp x 1.2
Termination Style
Screw
Unit Weight
1000g
Factory Pack Qty
9
Datasheet
Product Datasheet
Hobut CTSC CLIP 100/5 Series Current Transformer
Features
Low Price Point
Split Core
1m Flying Leads
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Flame Retardent UL94V0
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Site Measurements
Specification
Hobut Part Number
CTSC CLIP 100/5
Technology
Split Core AC Current Transformer
Ratio
100/5
Aperture Size
⌀ 40mm
VA Rating
1VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount
Operating Temperature Range
-30°C / 80°C
Continuous Current (max)
100Amp x 1.2
Termination Style
Screw
Unit Weight
800g
Factory Pack Qty
9
Datasheet
Product Datasheet
TRB-BG25, Toggle KeySwitch 2 Pos Latched Black 1NO + 1NC, IEC60947-5-1
Toggle Switches are used to Toggle between 2 or 3 Digital or Analogue Input Signals or to simply turn off control signals. Widely used for Rugged Industrial Applications Including Critical Machinery requiring safe and reliable repetitive operation by the user.
Features :
600V Insulation Rating
240VAC @ 3 Amp
22mm Cutout
Standards :
IP40
IEC60947-5-1
CE
Specification
TRENT Part Number
TRB-BG25
Functions
2 Pole, 3 Position Toggle Switch
Switch Type
Latching 1 x NO, 1 x NC
Nominal Voltage
240VAC @ 50/60Hz
Rated Impulse Voltage
6kV
Nominal Current Range AC
3 Amp @240VAC
Rated Insulation Voltage
600VAC
Humidity
35-85%
Approvals
CE
Standards
IEC60947-5-1, IP20 (IP40 Installed)
Weight
65g
Enclosure Material
UL94V0
Factory Pack Qty
1
TRENT(Fastron) Head Office
Australia
Datasheet
Product Datasheet
Crouzet Automation 84872141, Single Phase Voltage Control Relay Under/Over Voltage Detection - 17.5 mm MUS, 15-600VAC/DC Measurement, 24-48VAC/DC Supply, 1 x C/O Relays, 250VAC/DC @ 5 Amp
, Replaces DSR2 Series
For under and over voltage monitoring of Single phase AC or DC Voltages 65 to 260V
Features:
Control of AC and DC voltages
Automatic recognition of AC/DC
Measurement ranges from 15 V to 600 VAC/DC
Choice between under and over voltage
True RMS measurement
Selectable latching (memory) function
Specification
Crouzet Part Number
84872141 (Single Phase MUS Voltage Monitoring Relay With Non-Latching SPDT Contacts)
Function
Undervoltage/Overvoltage
Supply Voltage
24-48VAC/DC
Measurement Voltage
1 x 15 - 600 VAC/DC
Digital Outputs
1 x C/O Relays, 250VAC/DC @ 5 Amp
Min Breaking Current
10mA/5VDC
Delay on Threshhold Crossing
0.1 → 3s (0, +10%)
Delay on Pickup
600ms
Alarm Delay on Time (max)
200ms
Reset Time
1500ms
Adjustable Hysteresis
5 - 50% of Threshhold
Maximum Measurement Cycle Time
30ms/True RMS Measurement
Measurement Accuracy
1%
Supply Voltage Range
Same as Measurement
Termination Style
Screw
Weight
170g
Certification
CE, UL, CSA, GL, ROHS
Factory Pack Qty
1
Over Voltage Category
3 in accordance with IEC/EN 60664-1
Pollution Degree
2 in accordance with IEC/EN 61131-2
Protection rating
IP40 (Front), IP20 (Rear)
Mechanical Resistance
Immunity to vibrations IEC/EN 60068-2-6, test Fc
Immunity to shock IEC/EN 60068-2-27, test Ea
Resistance to HF Interference
Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12
Conducted and radiated emissions
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Operating Temperature
-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22
Datasheet
Product Datasheet
Cross
Replaces DSR2 Series
Rishabh Rish SIGMA 75 CTR5+5/5.CL1.15VA Summation Current Transformer
Features
DIN Rail Mounting Clip Included
Built In Sealable Terminal Covers
Mounting Feet Supplied
Narrow Width (30mm)
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
Rish SIGMA 75 CTR5+5/5.CL1.10VA
Technology
AC Current Transformer
Ratio
5+5/5
VA Rating
10VA Class 1
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
8 Amp
Termination Style
Screw
Unit Weight
500g
Factory Pack Qty
5
Datasheet
Product Datasheet
FTA-005-010-24, DC Current Transducer, +/-5 Amp , +/-10VDC Output, 24VDC supply, 21mm Aperture
Compact and versatile Split Core DC current sensor, +/-5 Amp , +/-10VDC Bipolar Output
Features
⌀21mm Aperture
DC Bipolar Measurement
+/-10VDC Instantaneous output
120mS Response (for 0- +/-10mA ~+/-10A AC) 10uS Response (0-+/-5A ~+/-100A AC)
Busbar, or panel mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Kit available
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
FTA-005-010-24
Technology
DC Current Transducer with Instant Output
Yes
Supply Voltage
24VDC
Nominal Current (RMS + DC)
+/-5 Amp
Response Time
< 1uS
Output
Bipolar +/-10VDC Analogue
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Aperture
20mm
Mounting Style
Panel Mount
Operating Temperature Range
-10°C / 85°C
Accuracy
1%
Termination Style
4 Pin Plug (Included)
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet
FP250160P G2, 2500/5 Amp Split Core CT, Class 0.5 15VA Series Clip On Current Transformer
Features
Quick Release Split Core System
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Electronics Part Number
FP250160P G2
Technology
Split Core AC Clip On Current Transformer
Ratio
2500/5
Aperture Size
83 x 163.5mm
VA Rating
15VA
Accuracy Class
Class 0.5
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
2500Amp x 1.2
Termination Style
Screw
Approvals
CE
Unit Weight
1150g
Factory Pack Qty
1
Datasheet
Product Datasheet
Installation Guide
Hobut CT105F-160/5-2.5/1 Class 1, 2.5VA 160 Amp, 5 Amp Output, 3 Phase Current Transformer, With Feet Mount
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Narrow Width (45mm)
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Hobut Part Number
CT105F-160/5-2.5/1
Technology
AC Current Transformer
Ratio
160/5
Aperture Size
21 x 25mm
VA Rating
2.5VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
160Amp x 1.2
Termination Style
Screw
Unit Weight
450g
Factory Pack Qty
9
Datasheet
Product Datasheet