LEM PCM 10-P/SP1 Series Closed Loop Bipolar DC Hall Effect Sensor for Point System Monitoring, Bipolar 4-20mA Output
Features
Closed loop sensor using Hall Effect
Panel mounting
Split core design for easy installation
Insulated plastic case to UL 94-V0 Water resistant design rated to IP 67
Reverse polarity protected
2M flying leads
Advantages
Very good linearity
Excellent accuracy
Current overload capability
No insertion losses.
Non - contact measurement (does not need a safety case)
Applications
Railway equipment
Points condition monitoring
Signal light indication
Battery supplied applications Uninterruptable Power Supplies (UPS).
Specification
LEM Part Number
PCM 10-P/SP1
Technology
Closed Loop Hall Effect
ROHS
Yes
Supply Voltage
24V
Aperture
ø15.6mm
Load Current (RMS + DC)
10 Amp
Measuring Range
+/- 20 Amp
Overload Capacity (Ampere Turns)
30000 Amp
Output
4-20mA
Standards
EN 50121-59EMC),EN 50155(temperature and humidity),EN61010-1/2 (safety)
Bandwidth
DC-1000Hz
Mounting Style
Panel Mount
Operating Temperature Range
-25°C / 70°C (55°C Continuous)
Accuracy
0.5%
Termination Style
Switchcraft EN3L4M connector with 2M Flying Leads
Unit Weight
120g
Factory Pack Qty
4
Datasheet
Product Datasheet
Application Notes
FAQ
LEM HOYL 200-S-0100 Series Closed Loop AC/DC Hall Effect Sensor
Features
Open loop multi-range current transducer
Voltage output
Single supply +5 V
Overcurrent detect 2.93 × IPN (peak value)
Galvanic separation between primary and secondary circuit
Low power consumption
For busbar mounting
Aperture: 40 × 13 mm
Factory calibrated ? Mating JST connector:
housing PAP-05V-S
contact SPHD-00xT-P0.5.
Advantages
Low offset drift
Over-drivable Vref
Creepage / clearance > 10.5 mm
Fast response
Low profile 2 mm pitch connector for 22 to 28 AWG wire.
Applications
AC variable speed and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Combiner box
Solar inverter on DC side of the inverter (MPPT).
Standards
IEC 61800-2: 2015
IEC 61800-3: 2004
IEC 61800-5-1: 2007 ? IEC 62109-1: 2010 ? UL 508: 2013.
Application Domain
Industrial.
Specification
LEM Part Number
HOYL 200-S-0100
Technology
Open Loop Hall Effect
Aperture
40 x 13mm
ROHS
Yes
Supply Voltage
5 VDC
Load Current (RMS + DC)
200 Amp
Measurement Range
+/-500 Amp
Output
2.5 Vref
Isolation
8 kV
Bandwidth
DC-140 kHz
Mounting Style
Busbar Mount
Operating Temperature Range
-40°C / 105°C
Accuracy
1%
Termination Style
JST B05B-PASK or equivalent
Unit Weight
232g
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM HOYL 800-S-0100 Series Closed Loop AC/DC Hall Effect Sensor
Features
Open loop multi-range current transducer
Voltage output
Single supply +5 V
Overcurrent detect 2.93 × IPN (peak value)
Galvanic separation between primary and secondary circuit
Low power consumption
For busbar mounting
Aperture: 40 × 13 mm
Factory calibrated ? Mating JST connector:
housing PAP-05V-S
contact SPHD-00xT-P0.5.
Advantages
Low offset drift
Over-drivable Vref
Creepage / clearance > 10.5 mm
Fast response
Low profile 2 mm pitch connector for 22 to 28 AWG wire.
Applications
AC variable speed and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Combiner box
Solar inverter on DC side of the inverter (MPPT).
Standards
IEC 61800-2: 2015
IEC 61800-3: 2004
IEC 61800-5-1: 2007 ? IEC 62109-1: 2010 ? UL 508: 2013.
Application Domain
Industrial.
Specification
LEM Part Number
HOYL 800-S-0100
Technology
Open Loop Hall Effect
Aperture
40 x 13mm
ROHS
Yes
Supply Voltage
5 VDC
Load Current (RMS + DC)
800 Amp
Measurement Range
+/-2000 Amp
Output
2.5 Vref
Isolation
8 kV
Bandwidth
DC-140 kHz
Mounting Style
Busbar Mount
Operating Temperature Range
-40°C / 105°C
Accuracy
1%
Termination Style
JST B05B-PASK or equivalent
Unit Weight
232g
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM HOYS 200-S-0100 Series Closed Loop AC/DC Hall Effect Sensor
Features
Open loop multi-range current transducer
Voltage output
Single supply +5 V
Overcurrent detect 2.93 × IPN (peak value)
Galvanic separation between primary and secondary circuit
Low power consumption
For busbar mounting
Aperture: 21.5 × 13 mm
Factory calibrated ? Mating JST connector:
housing PAP-05V-S
contact SPHD-00xT-P0.5.
Advantages
Low offset drift
Over-drivable Vref
Creepage / clearance > 10.5 mm
Fast response
Low profile 2 mm pitch connector for 22 to 28 AWG wire.
Applications
AC variable speed and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Combiner box
Solar inverter on DC side of the inverter (MPPT).
Standards
IEC 61800-2: 2015
IEC 61800-3: 2004
IEC 61800-5-1: 2007 ? IEC 62109-1: 2010 ? UL 508: 2013.
Application Domain
Industrial.
Specification
LEM Part Number
HOYS 200-S-0100
Technology
Open Loop Hall Effect
Aperture
21.5 x 13mm
ROHS
Yes
Supply Voltage
5 VDC
Load Current (RMS + DC)
200 Amp
Measurement Range
+/-500 Amp
Output
2.5 Vref
Isolation
5.4 kV
Bandwidth
DC-180 kHz
Mounting Style
Busbar Mount
Operating Temperature Range
-40°C / 105°C
Accuracy
1%
Termination Style
JST B05B-PASK or equivalent
Unit Weight
101g
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
SI4P22242045080 Electrolytic Capacitor, Snap In, ø45 x 80mm 420V 2200uF +/-20% 105°C
Characteristics and utility
2200uF, 450V0.0kvar 20kvar
Electrolytic
Connector type - 4 Pin snap in
Indoor mounting
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
LeClanche Part Number
SI4P22242045080
Technology
Electrolytic
Dimensions
ø45 x 80mm
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
420V
Operating Temperature Range
-40 to 105 °C
Capacitance
2200uF
Tolerance On Capacitance
+/- 20%
Lifetime
5000 Hours @ 105 °C
Termination Style
4 Pin Snap In Version
Unit Weight
0.25kg
Factory Pack Quantity
200
Datasheet
Product Datasheet
Fastron GFIN/100M-DR, GFIN Heatsink 100mm long with DIN Rail Clip 1.1 Deg C per Watt
DIN Rail or Panel Mount heat sink types
Suitable for SSR Mounting
Pre drilled for single or 3 phase SSR
Raw Finish
Specification
Fastron Part Number
GFIN/100M-DR
Mounting Type
Din Rail
Suitable SSR Rating
60/75 Amp
Dimensions (without SSR)
L:100mm x W:67mm x 88.5mm
Thermal Impedance
1.1°C/W
Load Current @ 40 Deg C
52.5 Amp
Load Current @ 50 Deg C
45 Amp
Unit Weight
700g
Factory Pack Qty
10
Datasheet
Product Datasheet
Product Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
SSR
Crydom HD6050, Solid State Relay, Single Phase 3-32VDC Control, 50A, 48-660VAC Load
Features
Ratings from 25A to 125 Amp @ 24-600 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
HD6050
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
3-32VDC
Load Current
50 Amp (rms)
Surge Capability
597 Amp (peak)
Special Feature
None
Mounting Style
Panel Mount
Load Voltage Range
48-660VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent
CY9008
CWD4890H
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Vishay VSKJ91/14, Dual Diode Module, Common Anode, 91 Amp, 1400V
Features
Thyristor for line frequency
Solder - Solder Bonded
Electrically insulated base plate
Industrial standard package
3600V Isolation
22mm Base Width
Applications
Power Converter
Line rectifying 50/60 Hz
Controlled Rectifiers
Softstart AC motor control
AC power control
Lighting and temperature control
Specification
Vishay Part Number
VSKJ91/16
Vrrm
1600V
Diode Configuration
Common Anode Dual Thyristor Module
IF(av) @ 85 Deg C
95 Amp
Package Size
W:22mm L:93mm D:30mm TO-240AA
Itsm
2 kA
VF(to)
0.97V
Tj(max)
125°C
rF
2.76mΩ
I(gt) @ 25 Deg C
150mA
Terminals
M5 Screw
Hole Centres
80mm (M6)
Gate Terminals
Spade (A 2.8 - 0.8 DIN 46244)
R th(j-c)
0.22°C/W
R th(c-h)
0.1°C/W
Weight
95g
Mounting Torque
4 Nm (3 Nm Terminals)
Factory Pack Qty
10
Certification
UL Listed, ROHS
Country of Origin
India
Datasheet
Product Datasheet
88980140, Crouzet Touch Software Version 6. Comes on USB stick
Crouzet Touch Soft V6.00.02.173
Software M3-soft-AC9-V3.1.2.0_ML
Remote Control Software CVD_PC_V2_3_01_02
Crouzet Soft EVO EM4 1.12.01.14
Crydom CWU4850P, Solid State Relay, Single Phase 20-48VDC or 20-280VAC Control, 50A, 48-530VAC Load, High Surge Rating w/status LED + Overvoltage Protection
Features
Ratings from 25A to 125 Amp @48-600VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
CWU4850P
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
20-48VDC or 20-280VAC
Load Current
50 Amp (rms)
Surge Capability
850 Amp (peak)
Special Feature
LED Status Indicator, High Surge, Internal Over Voltage Protection
Mounting Style
Panel Mount
Load Voltage Range
48-660VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent
See CWA2450P, CWD2450P, CWA4890P CWD4890H for stocked equivalent (no overvoltage protection).
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Westcode-IXYS-Littlefuse MCC162-18io1, 162 Amp, 1800V, Dual Thyristor Module
Features
Package with DCB ceramic
Electrically insulated base plate
Improved temperature and power cycling
Planar passivated chips
Very low forward voltage drop
Very low leakage current
3600V Isolation
Industrial standard package
20mm Base Width
Applications
Power Supplies
Rectifier for drives applications
Uncontrolled Rectifiers
Rectifiers for UPS
Battery Chargers
For single and three phase bridge configurations
Field supply for DC motors
Input rectifiers for PWM inverter
Specification
Westcode-IXYS-Littlefuse Part Number
MCC162-18io1
Vrrm
1800V
Diode Configuration
Dual Thyristor Module
IF(av) @ 85 Deg C
181 Amp
Package Size
TO-240AA W:20mm L:93mm D:30mm
Itsm
6 kA
VF(to)
0.88V
Tj(max)
125°C
rF
1.15mΩ
Terminals
M5 Screw
Hole Centres
80mm (M6)
Gate Trigger Current
N/A
R th(j-c)
0.155°C/W
R th(c-h)
0.07°C/W
Weight
150g
Mounting Torque
2.5 Nm (5 Nm Terminals)
Factory Pack Qty
10
Certification
UL Listed, ROHS
IXYS Headquarters
United States
Datasheet
Product Datasheet
Alternatives
See TT162N16KOF for Infineon Pressure Contact Alternative
Oztherm F940-A-60VAC-C1, AC Average RMS Voltage Transducer, 9-36VDC Supply, 0-60Volt, 4-20mA Measurement Output
Made to order, Delivery typically within 2 weeks