Crydom HS201DR + D1D40, Din Rail Mount DC Solid State Relay, with Heatsink 3-32VDC control, 25A @ 40 Deg C, 100VDC Load
Features
Ratings from 7A to 100 Amp @ 1-500VDC
Mosfet output for equal load sharing
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Part Number
HS201DR + D1D40
Switching Type
DC Switching
ROHS/CE/UL
Yes
Control Voltage
3.5 - 32VDC
Load Current
25 Amp DC @ 40 Deg C
Surge Capability
106 Amp DC
Special Feature
LED Status Indicator
Mounting Style
Panel Mount
Reccomended Load Voltage
1-72 VDC
Max Load Voltage
100 VDC
Termination Style
Screw Terminals
Dimensions
L:97mm x W:45mm x D:142.8mm
Unit Weight
415g
Factory Pack Qty
10
Datasheet
HS201DR
Series 1 DC
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
A53TP50D + HS212, Solid State Relay, and Heatsink Assembly, 3 Phase 90-280VAC Control, 20 Amp per phase @ 40 Deg C, 48-530VAC Load, LED Status Indicator
Features
Ratings from 25A to 50 Amp @ 70-530 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Approved
IP20 Cover Available
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
A53TP50D + HS212
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
4-32VDC
Load Current
3 x 20 Amp (rms) per Phase
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
Panel Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
315g
Factory Pack Qty
10
Datasheet
HS103DR
D53TP Series
3 Phase SSR and Heatsink Mounted
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
ACXP06R-MB (BLR-CX Plus 12R-MB), CX-Plus Power Factor Regulator, 12/13 Step, 1 Phase Measurement, 3 Phase Control, 110-480V 50/60HZ, Modbus RTU Comms, Step Time Recording, Alarm Recording, RS485 Modbus
Single CT Sensing
Isolated Switching of Power Factor Correction Contactors
Cos ϕ Setting 0.85 to 0.95 CAP
Auto CT Secondary Selection
Backlit LCD Display
Various Program Combinations
IP41
Up to 13 steps
Measurement System - Automatic/Manual
90-550VAC Aux/Measurement Supply
Configurable Alarms
Dual Password Protection
Programmable Fan Control
Programmable 1A/5A CT Ratio
Specification
Beluk Part Number
ACXP12R-MB (BLR-CX Plus 12R-MB) / 3ACXP12R-BEL-G-MB
Function
Reactive Power Correction
Nominal Voltage (Un)
110-480VAC Line to Line
Supply Voltage
90-300VAC (L-N), 15VA 45-65Hz
Relay Rating
250VAC/10Amp
Switch Delay Time
1s - 1200s User Adjustable
Alarm
1 x Relay as above
Temperature/Fan Alarm
1 x Relay as above (Can be used as 13th Step)
Re-connection Delay Time
50 - 1200s User Adjustable
Desired Power Factor
0.80 IND - 0.80 CAP
Number of Output Relays
6
Smallest Capacitor Current
10mA
CT Input Range
5mA - 6 Amp
LCD Display Accuracy
Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1
Phase Angle Error
+/- 1% at I > 3% of range
Comms
RS485 Modbus
Termination Style
Screw
Weight
700g
Certification
IEC 654-1
Factory Pack Qty
1
Material of housing
PC/ABS Unflammable, according to UL 94 V-0
Enclosure protection
IP50 for case, IP20 for terminals
Safety
According to EN 61 010-1, installation category III Pollution degree 2
Operating Temperature
-20...60 °C
Datasheet
User Manual
Modbus user Manual
Comparison of CX and CX Plus Controllers
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
Quick Start Guide(Blog)
Crydom HS301DR + D1D20, Din Rail Mount DC Solid State Relay, with Heatsink 3-32VDC control, 18A @ 40 Deg C, 100VDC Load
Ratings from 7 to 100 Amp @1-500VDC
Mosfet output for equal load sharing
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Part Number
HS301DR + D1D20
Switching Type
DC Switching
ROHS/CE/UL
Yes
Control Voltage
3.5-32VDC
Load Current
18 Amp DC @ 40 Deg C
Surge Capability
29 Amp DC
Special Feature
N/A
Mounting Style
Din Rail or Panel Mount
Recommended Voltage Range
1-72VDC
Max DC Voltage
100VDC
Termination Style
Screw Terminals
Dimensions
L:81mm x W:45mm x D:73.4mm
Unit Weight
296g
Factory Pack Qty
20
Datasheet
HS301DR
Series 1 DC
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Fastron H31/110M + D53TP50D, Three Phase Solid State Relay with Heatsink 3.5-32VDC Control, 3 x 34Amp, 48-530VAC Load
Features
Ratings from 25 to 120 Amp @ 48-533 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
IP20 Cover Included
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Fastron Part Number
H31/110M + D53TP50D
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
3-32VDC
Load Current
3 x 34 Amp (rms)
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
Panel Mount
Dimensions
L:110 x W:125 x D:180mm
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
2kg
Factory Pack Qty
10
Datasheet
Product Datasheet
H31 Datasheet
Equivalent
Contact Us for Possible Replacement
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
D53TP50D + HS212F, Solid State Relay, and Heatsink Assembly, 3 Phase 3-32VDC Control, 36 Amp per phase @ 40 Deg C, 48-530VAC Load, LED Status Indicator
Features
Ratings from 25A to 50 Amp @ 70-530 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Approved
IP20 Cover Available
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
D53TP50D + HS212DR-F
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
3-32VDC
Load Current
3 x 36 Amp (rms) per Phase
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
Din Rail Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
315g
Factory Pack Qty
10
Datasheet
HS212 Datasheet
D53TP Series
3 Phase SSR and Heatsink Mounted
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
PMG500-S, Single Phase Diode Rectifier Bridge, Switchable, 2 Amp 450VDC Output, 500VAC, Uin max 500VAC rms
Features
Low forward voltage drop
CE Certified
Applications
Heat and temperature control for industrial furnaces and chemical processes
Lighting control
Motor control
Power converter
Advantages
Easy to mount with two screws
Space and weight savings
Improved temperature and power cycling capability
High power density
Specification
Part Number
PMG500-S
AC Line voltage
500VAC
Device Configuration
Single Phase Diode Rectifier Bridge
DC Output @ 85 Deg C
2 Amp DC
Package Size
Itsm
20 Amp
VF(to)
0.85V
Tj(max)
150°C
rF
11mΩ
Terminals
M5 (5Nm)
Switching Terminals
screw
Weight
70g
Factory Pack Qty
10
Datasheet
Datasheet
Crydom HS201DR +D5D10, Din Rail Mount DC Solid State Relay, with Heatsink 3-32VDC control, 7.8A @ 40 Deg C, 500VDC Load
Features
Ratings from 7A to 100 Amp @ 1-500VDC
Mosfet output for equal load sharing
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Part Number
HS201DR +D5D10
Switching Type
DC Switching
ROHS/CE/UL
Yes
Control Voltage
3.5 - 32VDC
Load Current
7.8 Amp DC @ 40 Deg C
Surge Capability
29 Amp DC
Special Feature
LED Status Indicator
Mounting Style
Panel Mount
Reccomended Load Voltage
1-385 VDC
Max Load Voltage
500 VDC
Termination Style
Screw Terminals
Dimensions
L:81mm x W:45mm x D:115mm
Unit Weight
415g
Factory Pack Qty
10
Datasheet
HS201DR
Series 1 DC
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Fastron Electronics SCT-F24-250, 250 Amp, 0.333v Class 1 Series Current Transformer
Features
Quick Release Split Core System
Cable Mount
0.333v Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F24-250
Technology
Split Core AC Current Transformer
Ratio
250/0.333v
Aperture Size
ø 24 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333v (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
250Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
VX3-UMNA-A4T, Temp Controller/Indicator, 48x96mm, 100-240VAC, Multirange Input, 4-20mA PV Retransmission Output, 3 Alarms, Can replace Shinko JIR301M
Multirange Input (Programmable)
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP65 (front panel only)
UL/CE Approved
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 60 mm depth panel space
EC Compliant
Specification
Hanyoung Nux Part Number
VX3-UMNA-A4T
Control Output 1 (Heat)
Relay
Control Output 2 (Cool)
4-20mA PV Retransmission
Input
Multirange Type K/J/E/T/R/B/S/L/N/U/W/PLII/PT100/JPT100/4-20mA/0-20mA/1-5V/0-5V/0-10V/0-50mV/0-100mV. Note for Direct Current Input please use 250 Ohm Resistor in Parallel to the input terminals.
Alarm
4 x Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 1
2nd Alarm Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 2
N/A
Mounting Style
48 x 96mm Panel Mount
Supply Voltage
85 - 265VAC
Termination Style
Screw
Weight
350g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Datasheet
VX Series Brochure
VX Series Instruction Manual
Free Software
Hanyoung Nux TCS Software
Hanyoung Nux TCS Software User Manual
VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
Fastron Electronics GT-DVO(0-50V)D-1, DC Voltage Transducer, 0-50VDC input, 22-60VAC/DC aux, 4-20mA output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GT-DVO(0-50V)D-1
Control Output
4-20mA
Input
0 - 50VDC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
22 - 60VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet