Fastron FRI 8-03/1, Under/Over Current Monitoring Relay AC 0.1 - 1 A, Adjustable delay 0.5 - 10 s, 1 x CO 10 Amp, Universal 24-240VAC 24VDC Aux Supply
FRI 8 Series serves to monitor AC currents up to 16 Amp, and provides Relay alarm output with adjustable delay time 0.5 - 10s.
Features :
Suitable for Current Transformer Monitoring
Flexible adjustment by potentiometer, choise of
6 Models: 0.05 - 0.5 A; 0.1 - 1 A; 0.2 - 2 A; 0.5 - 5 A; 0.8 - 8 A; 1.6 - 16 A Adjustable delay 0.5 - 10 s to eliminate short current peaks
Possible to use current scanning from current transformer - up to 600 A Universal supply AC 24 - 240 V and DC 24 V
Supply is galvanically separated from measured current
Output contact: 1 x changeover 8 A
1-phase, 1-MODULE, DIN rail mounting
Applications :
Heating bars in sliding rails
Heating cables
Indication of current flow
Controlling of 1-phase motor consumption
Specification
Fastron Part Number
FRI 8-03/1
Voltage Range
AC 24 - 240 V, DC 24 V (AC 50 - 60 Hz)
Operating Range
-15 %; ? %
Current Range
0.1 - 1 A (AC 50 Hz)
Current Trip Adjustment
Potentiometer
Setting Accuracy
5 %
Burden
max. 1.5 VA
Repeatability
1 %
Temperature Drift
0.1%/??C
Peak Overload (10s)
1.1 x Ipn
Time delay T1
max. 500 ms
Time delay T2
adjustable 0.1-10 s
Output
??
Number of contacts
1x changeover/ SPDT (AgNi / Silver Alloy)
Rating
10 A / AC1
Breaking capacity
2500 VA / AC1, 240 W / DC
Inrush current
10 A
Switching voltage
250 V AC1 / 24 V DC
Min. breaking capacity DC
500 mW
Indication of state
red LED
Mechanical life
1 x 107
Electrical life (AC1)
1 x 105
Other information
??
Operating temperature
-20 ... ? ??C
Storage temperature
-30 ... ? ??C
Electrical strength
4 kV (supply - output)
Operating position
any
Mounting
DIN rail EN 60715
Protection degree
IP 40 from front panel / IP 10 terminals
Overvoltage cathegory
III.
Pollution degree
2
Max. cable size (mm )2
solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5
Dimensions
90 x 17,6 x 64 mm
Weight
69 g
Standards
EN 60255-6, EN 61010-1, RoHS, CE
Datasheet
Product Datasheet
Application Notes
Monitoring relay FRI serves to monitor current level in single phase AC circuits. Due to its fluent adjustment of release current, it is predestined for applications with necessity of current flow indication, and can be used as precedence relay. Output relay is off in normal state. In case the set current level is exceeded, it switches. Multivoltage supply is an advantage.
Fastron FDV-15-420-24, Battery DC Voltage Transducer, Din Rail Mount, 0-15VDC, 4-20mA output, 24VDC Supply Voltage, 150mS Response
150mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 5V DC output (for voltage output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Part Number
FDV-15-420-24
Analogue Output
4-20mA
Input
0-15VDC
Measurement Range
120%
Overload
150% Continuous
Operating Temperature
-30 - 70°C
Operating Voltage
24VDC +/-15%
Voltage Isolation (1 min)
2.5kV
Accuracy
1%
Response Time
150mS
Termination Style
Screw
Mounting Style
DIN Rail Mount
Safety
CE, UL94V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron FDV-50-V10-24, DC Voltage Transducer, Din Rail Mount, 0-50VDC, 0-10V output, 24VDC Supply Voltage, 150mS Response
150mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 5V DC output (for voltage output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Part Number
FDV-50-V10-24
Analogue Output
0-10V
Input
0 - 50VDC
Measurement Range
120%
Overload
150% Continuous
Operating Temperature
-30 - 70°C
Operating Voltage
24VDC +/-15%
Voltage Isolation (1 min)
2.5kV
Accuracy
1%
Response Time
150mS
Termination Style
Screw
Mounting Style
DIN Rail Mount
Safety
CE, UL94V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
BS1-ND105, Digital DC Voltmeter, 48x24mm, 85-265VAC, Range : 0-500VDC
3.5-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
UL/CE Approved
Each unit needs just 100.2 mm depth panel space
EC Compliant
Specification
Hanyoung Nux Part Number
BS1-ND105
Input
0-500VDC
Mounting Style
48 x 24mm Panel Mount
Supply Voltage
85 - 265VAC
Termination Style
Screw
Weight
250g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Datasheet
BS1 Series Instruction Manual
BS1 Series Wiring and Selection Tables
Free Software
Hanyoung Nux TCS Software
Hanyoung Nux TCS Software User Manual
VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
Fastron FC5-M-W-1-G-4-C PID Controller, 24VDC with 1 Alarm, RS485, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 72x72mm, Relay + SSR Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
FC5-M-W-1-G-4-C
Control Output
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)/ SSR 12VDC 40mA
Input
Multirange K,E,J,N,T,S,R,B Thermocouple, PT100/Cu20 RTD Input/Linear Current 4(0)-20mA/Linear Voltage 0-10(5)V
Option 1
1 Alarm, RS485 standard (Excludes 72x72mm with SSR/Relay output)
Comms
RS485 Modbus RTU 38400 Max Baud Rate
Mounting Style
72x72mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet & User Manual
Datasheet
User Manual
FC5 Communication Protocol
Fastron FDV-500-V05-24, DC Voltage Transducer, Din Rail Mount, 0-500VDC, 5V output, 24VDC Supply Voltage, 150mS Response
150mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 5V DC output (for voltage output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Part Number
FDV-500-V05-24
Analogue Output
5V
Input
0 - 500VDC
Measurement Range
120%
Overload
150% Continuous
Operating Temperature
-30 - 70°C
Operating Voltage
24VDC +/-15%
Accuracy
1%
Response Time
150mS
Voltage Isolation (1 min)
2.5kV
Termination Style
Screw
Mounting Style
DIN Rail Mount
Safety
CE, UL94V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Lumel SM61IoT-1100M0, Datalogger with Internal Web page, Universal 85-253VAC, 90-300VDC Supply, 2 Relays, Modbus, Email Alarm Feature TCP/RTU,MQTT,HTTP/TCP/UDP/FTP/RS485/RS232/USB Comms
MQTT protocol for IoT Applications
Internal Web page
1GB Flash Memory (Optional 8GB)
USB/RS232/RS485/Ethernet Comms as standard
Modbus TCP/RTU,MQTT,HTTP/TCP/UDP/FTP Protocols
Universal 85-253VAC, 90-300VDC Supply
Relays Alarms (Optional Digital Alarms)
Email Alarm Feature
Features :
Built in Web Page and FTP Server
2 RS485 Ports or 1 x RS485 and 1 x RS232 Ports
2 Relay Alarms
Real Time Clock
Simultaneous Interrogation of Data
Password Data Access
Email Alarm Function
Specification
Lumel Part Number
SM61IoT-1100E0
Functions
Communication Datalogger and Alarm Unit
Supply Voltage
90-300VDC or 85-253VAC
Protocols
TCP/RTU,MQTT,HTTP/TCP/UDP/FTP
Communication Ports
RS485/RS232,RS485,USB,Ethernet
RS485/RS232 Baud Rate
1200,2400,4800,9600,19200,38400,57600,115200 bit/s
USB Baud Rate
115200 bit/s
Ethernet Baud Rate
10,100 Mbit/s
Real Time Clock
1min/month (30ppm)
Isolation
3.5kV
Weight
250g
Language
English and Polish version
Factory Pack Qty
1
EU Directives
EN61000, EN61010
Safety
Protection Class II
Enclosure Material
PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0
Enclosure Protection
IP20
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
User Manual
Crouzet 88886016, Syr-Line Multirange Timer TMR 48 X, 11 Pin, Single Pole 5A CO (SPDT) Delay 0.02s - 300h, 12-240VDC, 24-240VAC, 48x48mm, Functions A1, A2, H1, H2, Q1, Q2, D-Di
TMR 48 X Timers Syrline 48x48mm - 1 Relay 5A :
Multi-Function
Mono Function
Multi-range (0.02 s – 300 h)
Multi-voltage (12-240VDC/24-240 V AC)
2 x CO relay outputs (Changeover)
DIN Sized (48x48 mm) Housing
Compact body (64.5 mm long)
Water & Dust-proof (IP50)
11-Pin
Multifunction Timers Include The Following :
A1, A2, H1, H2, Q1, Q2, D-Di
Specification
Crouzet Part Number
88886016
Function
Multifunction & Mono Function TimerA1, A2, H1, H2, Q1, Q2, D-Di
Nominal Voltage
12 - 240VDC / 24 → 240 VAC
Digital Output
2 x C/O (SPDT) (Changeover -Single Pole Double Throw), 250VAC/DC @ 5 Amp
Min Breaking Current
10mA/12VDC
Timing Ranges
Selectable 0.02→300h
Minimum Pulse Duration
30ms/100ms with load
Repeatability
0.5%
Reset Time
120ms
Memory
N/A
Isolation
1kV
Repetition Accuracy
0.5%
Threshold Adjustment Range
10 → 100 % of the range
Termination Style
11 Pin Base
Weight
80g
Certification
CE, cULus,CCC, ROHS, Reach, WEEE
Factory Pack Qty
1
Over Voltage Category
3 in accordance with IEC/EN 60664-1
Pollution Degree
2 in accordance with IEC/EN 61131-2
Protection rating
IP50 (Front), IP40 (Rear)
Mechanical Resistance
Immunity to vibrations IEC/EN 60068-2-6, test Fc
Immunity to shock IEC/EN 60068-2-27, test Ea
Resistance to HF Interference
Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12
Conducted and radiated emissions
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Operating Temperature
-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22
Datasheet
Product Datasheet
Crydom DRA-CN024D24, Slimline Relay & Socket, 15-30VDC Coil, 3.5 Amp 24VDC Load
Features
Output 3.5 Amp @ 24VDC
15-30VDC Control input
DIN Rail Mount
Ultra slim package
CE Compliant to IEC 60664
IP67
Specification
Crydom Part Number
DRA-CN024D24
Switching Type
24VDC 3.5 Amp SSR
Approvals
UL, CE
ROHS
Yes (Details)
Control Voltage
15-30VDC
Load Current
3.5 Amp (rms)
Special Feature
LED Status Indicator
Mounting Style
Socket Mount (F41F-1Z-C2-5 12-14VAC/DC)
Load Voltage Range
24VDC Load
EMC Compliant
Level 3
Termination Style
PCB or Socket Mount
Unit Weight
6g
Factory Pack Qty
20
Datasheet
Relay Datasheet
Crydom E53TP50C, Solid State Relay, 3 Phase 18-36VAC(24VAC) Control, 50A, 48-530VAC Load, LED Status Indicator, IP20
Features
Ratings from 25A to 50 Amp @ 70-480 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Approved
IP20 Cover Available
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
E53TP25C
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
18-36VAC (24VAC)
Load Current
25 Amp (rms) per Phase
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
Panel Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
315g
Factory Pack Qty
10
Datasheet
Product Datasheet
Equivalent
Contact Us for Possible Replacement
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
84874320 Crouzet C-Lynx Speed Monitoring/Control Relay With SPDT Contacts, 24 - 240 V AC/DC
Pick up this Crouzet HSV Control/Speed Monitoring Relay from the team at Fastron Electronics. Capable of controlling overspeed, operating rate, underspeed, and stopping, this is an industry-leading speed monitoring relay component.
Compatible with either NC or NO sensors, this monitoring/control relay also features adjustable energy monitoring capabilities.
For more information about this product, explore the description, specification and datasheet on this page. Alternatively, the Fastron Electronics team is always happy to assist you with all your technical support requirements. With more than 40 years of experience in energy monitoring and energy management, we are proud to offer the highest quality products, with free shipping available on all purchases over $300AUD.
Looking for an alternative product? Contact Fastron Electronics today to enquire about availability and pricing information. We would be more than happy to help you with your custom project.
Crouzet HSV Speed Monitoring/Control Relay With SP-NO/NC Contacts
DIN Rail Mount 35 mm HSV Part number 84874320 :
Control of overspeed, underspeed, operating rate, stopping
Measurement via discrete sensors - 3-wire PNP or NPN, Namur, voltage 0-30V or volt-free contact type
Works with either NO or NC sensors
Time between pulses adjustable from 0.05 s to 10 min.
Power-on inhibit time, adjustable from 0.6 to 60 s Inhibit time can be managed via an external contact
Specification
Crouzet Part Number
84874320 (Single Phase C-Lynx Speed Monitoring Relay With SPDT Contacts)
Function
Speed Control
Nominal Voltage
24 → 240 V AC/DC
Frequency of Measured Signal
1.5 m Hz minimum, 22 Hz maximum
Measurement Ranges
0,5 s - 1 s - 5 s - 10 s - 1 mn - 5 mn - 10 mn
Digital Output
1 x C/O Relays, 250VAC/DC @ 5 Amp
Min Breaking Current
10mA/5VDC
Inhibit Delay Timing Range
0.6 → 60s (0, +10% of full scale)
Delay on Pickup
50ms
Threshold Crossing Response
15ms
Reset Time (Memory Mode)
50ms
Reset Time (Power Break)
1500ms
Isolation
4kV
Repetition Accuracy
0.5%
Threshold Adjustment Range
10 → 100 % of the range
Termination Style
Screw
Weight
170g
Certification
UL, CSA, ROHS
Factory Pack Qty
1
Over Voltage Category
3 in accordance with IEC/EN 60664-1
Pollution Degree
2 in accordance with IEC/EN 61131-2
Protection rating
IP40 (Front), IP20 (Rear)
Mechanical Resistance
Immunity to vibrations IEC/EN 60068-2-6, test Fc
Immunity to shock IEC/EN 60068-2-27, test Ea
Resistance to HF Interference
Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12
Conducted and radiated emissions
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Operating Temperature
-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22
Datasheet
Product Datasheet
Fastron Electronics GA5-D-A6-D-N, 96x48mm 5 DIGIT DC Ammeter DC Voltmeter 4-20mA input, 22-60VAC/DC Supply
Adjustable Zero and Span Setting
Adjustable Display Scaling
Large 5 Digit 20.3mm (8 Inch) LED Display
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 96 x 48mm Panel Space
90mm Depth
Specification
Fastron Electronics Part Number
GA5-D-A6-D-N
Conditioner Output
N/A
Input
4-20mA
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
22-60VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
96 x 48mm Panel Mount (60mm depth)
Case Material
PC - UL 94 V0
Weight
320g
Factory Pack Qty
1
Datasheet
Product Datasheet
Application Notes
Panel Meters Blog Articles