H71/110M + FTH2553ZD3, 4-32VDC Control, 3 x 13Amp, 48-530VAC Load, LED Status Indicator, Three Phase Solid State Relay 4-32VDC Control, 3 x 13Amp, 48-530VAC Load, with IP20 Cover
Ratings from 25A to 120 Amp @ 70-530 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Approved
IP20 Cover Available
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Includes IP20 Cover
Specification
Fastron Part Number
H71/110M + FTH2553ZD3
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
4-32VDC
Load Current
3 x 13 Amp (rms) per Phase @ 50 Deg C
Surge Capability
350 Amp (peak)
Special Feature
LED Status Indicator, with IP20 Cover
Mounting Style
Panel Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
650g
Factory Pack Qty
10
Datasheet
H71 Datasheet
FTH Series
Product Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Crydom DR48D06, Solid State Relay, 4-32VDC control, 6 Amp 48-600V AC Output, Slimline, Din Rail Mount, LED status Indicator
Features
Ratings from 6A to 12 Amp @ 48 - 600VAC
DIN Rail Mount
SCR output for reliable AC switching
Ultra slim package
UL/CSA/VDE Approved, CE Compliant to EN60950-1
EMC compliant to Level 3
Epoxy free design
Spec
Crydom Part Number
DR48D06
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
4-32VDC
Load Current
6 Amp (rms)
Surge Capability (10ms)
410 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
DIN Rail Mount
Load Voltage Range
48 - 600VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
38g
Factory Pack Qty
20
Datasheet
Product Datasheet
Equivalent
DRA1-CMX60D10
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
FTH2553ZA4 + HS212, Solid State Relay, and Heatsink Assembly, 3 Phase 90-280VAC Control, 20 Amp per phase @ 40 Deg C, 48-530VAC Load, LED Status Indicator, with IP20 Cover
Features
Ratings from 25A to 50 Amp @ 70-530 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Approved
IP20 Cover Available
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Fastron Part Number
FTH2553ZA4 + HS212
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
90-280VAC
Load Current
3 x 20 Amp (rms) per Phase
Surge Capability
350 Amp (peak)
Special Feature
LED Status Indicator, with IP20 Cover
Mounting Style
Panel Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
315g
Factory Pack Qty
10
Datasheet
HS103DR
D53TP Series
3 Phase SSR and Heatsink Mounted
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
FTH6053ZD3 + HS212F, Solid State Relay, and Heatsink Assembly, 3 Phase 3-32VDC Control, 36 Amp per phase @ 40 Deg C, 48-530VAC Load, LED Status Indicator, with IP20 Cover
Features
Ratings from 25A to 50 Amp @ 70-530 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Approved
IP20 Cover Available
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Fastron Part Number
FTH6053ZD3 + HS212F
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
3-32VDC
Load Current
3 x 36 Amp (rms) per Phase
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator, with IP20 Cover
Mounting Style
Din Rail Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
1.2kg
Factory Pack Qty
10
Datasheet
HS103DR
Product Datasheet
3 Phase SSR and Heatsink Mounted
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
FTH6053ZA4 + HS212DR, Solid State Relay, and Heatsink Assembly, 3 Phase 90-280VAC Control, 20 Amp per phase @ 40 Deg C, 48-530VAC Load, LED Status Indicator, with IP20 Cover
Features
Ratings from 20A to 36 Amp @ 70-530 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Approved
IP20 Cover Available
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Fastron Part Number
FTH6053ZA4 + HS212DR
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
90-280VAC
Load Current
3 x 20 Amp (rms) per Phase
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator, with IP20 Cover
Mounting Style
Din Rail Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
1.2kg
Factory Pack Qty
10
Datasheet
HS212 Datasheet
D53TP Series
3 Phase SSR and Heatsink Mounted
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crydom CMRD6045, Solid State Relay, Single Phase 3.5-32VDC Control, 45A, 48-660VAC Load, Din Rail
Features
• Ratings from 35A to 65Amp @ 48-660 VAC
• SCR output for heavy industrial loads
• Zero voltage or instantaneous turn-on outputs
• UL/CSA/VDE Approved, CE Compliant to EN60950-1
• Improved SEMS screw and washer
• Redesigned housing with anti-rotation barriers
• AC & DC control types
• Direct bond copper substrate
• EMC compliant to Level 3
• Direct power lead frame
• Epoxy free design
Spec
Crydom Part Number
CMRD6045
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
4-32VDC
Load Current
45 Amp (rms)
Surge Capability
625 Amp (peak)
Special Feature
None
Mounting Style
DIN Rail Mount
Load Voltage Range
48 - 660VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
500g
Factory Pack Qty
20
Datasheet
Product Datasheet
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
FTH2553ZD3 + HS212, Solid State Relay, and Heatsink Assembly, 3 Phase 4-32VDC Control, 20 Amp per phase @ 40 Deg C, 48-530VAC Load, LED Status Indicator, with IP20 Cover
Features
Ratings from 25A to 50 Amp @ 70-530 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Approved
IP20 Cover Available
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Fastron Part Number
FTH2553ZD3 + HS212DR
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
4-32VDC
Load Current
3 x 20 Amp (rms) per Phase
Surge Capability
350 Amp (peak)
Special Feature
LED Status Indicator, with IP20 Cover
Mounting Style
Panel Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
315g
Factory Pack Qty
10
Datasheet
HS212 Datasheet
D53TP Series
3 Phase SSR and Heatsink Mounted
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
FTH6053ZA4 + HS212, Solid State Relay, and Heatsink Assembly, 3 Phase 90-280VAC Control, 20 Amp per phase @ 40 Deg C, 48-530VAC Load, LED Status Indicator, with IP20 Cover
Features
Ratings from 25A to 50 Amp @ 70-530 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Approved
IP20 Cover Available
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Fastron Part Number
FTH6053ZA4 + HS212
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
90-280VAC
Load Current
3 x 20 Amp (rms) per Phase
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator, with IP20 Cover
Mounting Style
Din Rail Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
1.2kg
Factory Pack Qty
10
Datasheet
HS103DR
D53TP Series
3 Phase SSR and Heatsink Mounted
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crydom CMD2450, Solid State Relay, Single Phase 3-32VDC Control, 50A, 24-280VAC Load
Features
Ratings from 25A to 90 Amp @ 24-280 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
CMD2450
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
3-32VDC
Load Current
40 Amp (rms)
Surge Capability
597 Amp (peak)
Special Feature
None
Mounting Style
Panel Mount
Load Voltage Range
24-280VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent
D2440
HD4850
CY9008
CWD2450P
HD6050
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Fastron FTH2553ZA4 + HS103DR, Three Phase Solid State Relay 90-280VAC Control, 3 x 21Amp, 48-530VAC Load, LED Status Indicator, with IP20 Cover
Ratings from 25A to 50 Amp @ 70-530 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Approved
IP20 Cover Available
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Includes IP20 Cover
Specification
Crydom Part Number
HS103DR + FTH2553ZA4
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
90-280VAC
Load Current
3 x 18 Amp (rms) per Phase
Surge Capability
350 Amp (peak)
Special Feature
LED Status Indicator, with IP20 Cover
Mounting Style
Din Rail Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
900g
Factory Pack Qty
10
Datasheet
HS103DR
D53TP Series
FTH6053ZD3 + HS212DR-F, Solid State Relay, and Heatsink Assembly, 3 Phase 4-32VDC Control, 36 Amp per phase @ 40 Deg C, 48-530VAC Load, LED Status Indicator, with IP20 Cover
Features
Ratings from 25A to 50 Amp @ 70-530 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Approved
IP20 Cover Available
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Fastron Part Number
FTH6053ZD3 + HS212DR-F
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
4-32VDC
Load Current
3 x 36 Amp (rms) per Phase
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator, with IP20 Cover
Mounting Style
Din Rail Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
1.2kg
Factory Pack Qty
10
Datasheet
HS212 Datasheet
D53TP Series
3 Phase SSR and Heatsink Mounted
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crydom HS211 + D5D10, Din Rail Mount DC Solid State Relay, with Heatsink 3-32VDC control, 7.5A @ 40 Deg C, 500VDC Load
Features
Ratings from 7 to 100 Amp @1-500VDC
SCR output
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Panel Mount
Din Rail Mount
Spec
Part Number
HS211 + D5D10
Switching Type
DC Switching
ROHS/CE/UL
Yes
Control Voltage
3.5-32VDC
Load Current
7.5 Amp (rms) @ 40 Deg C
Surge Capability
29 Amp (peak)
Special Feature
N/A
Mounting Style
Din Rail or Panel Mount
Recommended Voltage Range
1-385VDC
Max DC Voltage
500V
Termination Style
Screw Terminals
Dimensions
L:81mm x W:45mm x D:73.4mm
Unit Weight
296g
Factory Pack Qty
20
Datasheet
HS211
Series 1 DC
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies