Crouzet 88974161, Millenium 3 Essential XD26-16I/10O R Programmable Logic Controllers, Blue Display
Highly visible blue LCD with 4 lines of 18 characters and configurable backlighting
More cost effective solution
Allow the use of the entire library of specific functions blocs of the software workshop
Extended temperature range (-20 °C →+70 °C)
Analogue inputs 0-10 VDC, Potentiometer, NTC, LDR (0-20 mA/Pt100 with converters)
Open to XN network communication extensions, digital I/O, analogue, Pt100 extensions
HMI Screens Available
Specification
Crouzet Part Number
88974161 (XD26-16I/10O R)
Analogue Inputs
0-10VDC (x6)
Digital Inputs
12/24VDC (4.4mA @ 12VDC) (x16)
Digital Outputs
Relay, 5-30VDC,24-250VAC @ 10mA minimum (x10)
PWM SSR Output
12-24VDC @ 500mA (x4)
Expandable
Yes
LCD Display
Blue
Mounting Style
DIN Rail Mount (124.6mm)
Supply Voltage Range
24VDC (21.6 - 28.8VDC)
Termination Style
Screw
Weight
350g
Certification
CE, UL, CSA, GL
Factory Pack Qty
1
Over Voltage Category
3 in accordance with IEC/EN 60664-1
Pollution Degree
2 in accordance with IEC/EN 61131-2
Protection rating
IP40 (Front), IP20 (Rear)
Mechanical Resistance
Immunity to vibrations IEC/EN 60068-2-6, test Fc
Immunity to shock IEC/EN 60068-2-27, test Ea
Resistance to HF Interference
Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12
Conducted and radiated emissions
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Operating Temperature
-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22
Datasheet
Product Datasheet
Selection Chart
Software
Crouzet Touch Soft V6.00.02.173
Software M3-soft-AC9-V3.1.2.0_ML
Remote Control Software CVD_PC_V2_3_01_02
Crouzet Soft EVO EM4 1.12.01.14
Crouzet 88974142, Millenium 3 Essential PLC XD10-6I/4O S, 6 x On/Off inputs, Incl 4 analogue inputs, 4 Solid State outputs incl 1 x PWM output, 24 VDC, EXPANDABLE
Highly visible blue LCD with 4 lines of 18 characters and configurable backlighting
Allow the use of the entire library of specific functions blocs of the software workshop
Extended temperature range (-20 °C →+70 °C)
Analogue inputs 0-10 VDC, Potentiometer, NTC, LDR (0-20 mA/Pt100 with converters)
Open to XN network communication extensions, digital I/O, analogue, Pt100 extensions
HMI Screens Available
Specification
Crouzet Part Number
88974142 (XD10-6I/4O S)
Analogue Inputs
0-10VDC (x4)
Digital Inputs
12/24VDC (4.4mA @ 12VDC) (x6)
Digital Outputs
4 x SSR 12/24VDC @ 500mA (x4)
PWM SSR Output
12-24VDC @ 500mA (x1)
Expandable
Yes
LCD Display
Yes
Mounting Style
DIN Rail Mount (71.2mm)
Supply Voltage Range
24VDC (21.6 - 28.8VDC)
Termination Style
Screw
Weight
250g
Certification
CE, UL, CSA, GL
Factory Pack Qty
1
Over Voltage Category
3 in accordance with IEC/EN 60664-1
Pollution Degree
2 in accordance with IEC/EN 61131-2
Protection rating
IP40 (Front), IP20 (Rear)
Mechanical Resistance
Immunity to vibrations IEC/EN 60068-2-6, test Fc
Immunity to shock IEC/EN 60068-2-27, test Ea
Resistance to HF Interference
Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12
Conducted and radiated emissions
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Operating Temperature
-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22
Datasheet
XD10-6I/4O Brochure
XD10-6I/4O Datasheet
Software
Crouzet Touch Soft V6.00.02.173
Software M3-soft-AC9-V3.1.2.0_ML
Remote Control Software CVD_PC_V2_3_01_02
Crouzet Soft EVO EM4 1.12.01.14
LEM LF 1010-S, C/L Hall Effect Sensor, 1000 Amp, +/-200mA Output, 40.5mm Aperture, +/-15..24V Supply, Panel Mount
Features
Bipolar and insulated current measurement up tp 2700 Amp
Current output
Bandwidth DC to 100kHz
Closed loop (compensated) current transducer
Panel mounting
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low offset drift over temperature
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Applications
Windmill Inverters
Test and Measurement
Substations
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Application Domain
Industrial
Standards
EN 50178:1997
IEC61010-1:2010
UL 508:2010
Specification
LEM Part Number
LF 1010-S
Technology
Closed Loop Hall Effect
Aperture
ø40.5mm
ROHS
Yes
Supply Voltage
+/- 15 VDC to +/- 24 VDC Bipolar, Isolated
Load Current (RMS + DC)
1000 Amp
Measurement Range
+/- 2700 Amp
Output
200 mA
Isolation
3.8 kV
Bandwidth
DC-200 kHz
Mounting Style
Panel Mount
Operating Temperature Range
-10°C / 85°C
Accuracy
0.2%
Termination Style
Molex 6410
Unit Weight
503g
Factory Pack Quantity
9
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Crydom DR48D06, Solid State Relay, 4-32VDC control, 6 Amp 48-600V AC Output, Slimline, Din Rail Mount, LED status Indicator
Features
Ratings from 6A to 12 Amp @ 48 - 600VAC
DIN Rail Mount
SCR output for reliable AC switching
Ultra slim package
UL/CSA/VDE Approved, CE Compliant to EN60950-1
EMC compliant to Level 3
Epoxy free design
Spec
Crydom Part Number
DR48D06
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
4-32VDC
Load Current
6 Amp (rms)
Surge Capability (10ms)
410 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
DIN Rail Mount
Load Voltage Range
48 - 600VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
38g
Factory Pack Qty
20
Datasheet
Product Datasheet
Equivalent
DRA1-CMX60D10
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crouzet 88975111, Millenium EVO Ethernet, Smart Relay with Display, 24 I/O, 24VDC, 8 Configurable Analogue/Digital Inputs, 4 x High Speed 15kHz Inputs, 4 x Std Digital Inputs, 2 x 6 Amp Relay, 6 x 8 Amp Relay
Up to 44 I/Os - 16 DI (4 HighSpeed / 8 AI) - 8 DO
Wireless programming & Control with bluetooth Interface and Crouzet Virtual Display
Modbus RTU Network (Slave)
Local datalog management
Up to 1000 programing blocks with intuitive Crouzet Soft to go from simple to complex applications
HMI Screens Available
Specification
Crouzet Part Number
88975111 (Millenium EVO)
Analogue Inputs
0 - 10VDC, 0-V Power Supply or Voltmeter
Digital Inputs
24VDC @ 2.1mA (8 Standard and 4 High Speed)
Digital Outputs
Relay, 24VDC, 250VAC @ 100mA minimum (2 x 6 Amp, 6 x 8 Amp)
PWM SSR Output
None
Expandable
Yes
Comms
Ethernet. (RS485, Bluetooth). Standard and Wifi versions available
LCD Display
Yes
Mounting Style
DIN Rail Mount (124.6mm)
Supply Voltage Range
24VAC (21.6 - 28.8VAC)
Termination Style
Screw
Weight
350g
Environmental
Reach, RoHS, Halogen free 1272/2008/CE
Certification
CE, cULus Listed
Factory Pack Qty
1
Over Voltage Category
3 in accordance with IEC/EN 60664-1
Pollution Degree
2 in accordance with IEC/EN 61131-2
Protection rating
IP40 (Front), IP20 (Rear)
Mechanical Resistance
Immunity to vibrations IEC/EN 60068-2-6, test Fc
Immunity to shock IEC/EN 60068-2-27, test Ea
Resistance to HF Interference
Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12
Conducted and radiated emissions
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Operating Temperature
-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22
Datasheet
Product Datasheet
Launching Note
Software
Crouzet Touch Soft V6.00.02.173
Software M3-soft-AC9-V3.1.2.0_ML
Remote Control Software CVD_PC_V2_3_01_02
Crouzet Soft EVO EM4 1.12.01.14
Powersem PSCH85/16 Single Phase Half Controlled Rectifier Bridge with Freewheeling Diode
Features
Package with DCB ceramic base plate
Isolation voltage 3000 V∼
Planar glass passivated chips
Low forward voltage drop
Leads suitable for PC board soldering
UL registered, E 148688
Applications
Heat and temperature control for industrial furnaces and chemical processes
Lighting control
Motor control
Power converter
Advantages
Easy to mount with two screws
Space and weight savings
Improved temperature and power cycling capability
High power density
Specification
Powersem Part Number
PSCH85/16
AC Line voltage
533V
Device Configuration
Single Phase Half Controlled Bridge w/ Freewheeling
DC Output @ 85 Deg C
82 Amp
Package Size
W:67mm L:50mm D:30mm
Itsm
1150 A
VF(to)
0.85V
Tj(max)
125°C
rF
11mΩ
Terminals
M5 (1.5Nm)
Hole Centres
50mm (M5)
Gate Terminals
M3 (5Nm)
R th(j-c)
0.65°C/W
R th(c-h)
0.15°C/W
Weight
220g
Isolation
3kV
Factory Pack Qty
10
Certification
UL Listed
Powersem Headquarters
Germany
Datasheet
Product Datasheet
Alternatives
See PSCH125/16 for higher rated equivalent
LEM DHAB S/133 Series O/L Automotive AC/DC Current Transducer, Multirange
Features
Open Loop Transducer using Hall Effect
Low Voltage Application
Unipolar +5V Power Supply
Primary Current Measuring Range up to +/-75A, and +/-750A for Channel 2
Maximum RMS primary admissable current: defined by busbar to have T° < +150°C
Operating Temperature Range: -40°C < T° < +125°C
Output Voltage: Full ratio-metric (in sensitivity and offset)
Dual Channel Sensor for Wider Measurement Range and Redundancy
Advantages
Good Accuracy for High and Low Current Range
Good Linearity
Low Thermal Offset Drift
Low Thermal Sensitivity Drift
Hermetic Package
Automotive Applications
Battery Pack Monitoring
Hybrid Vehicles
EV and Utility Vehicles
Specification
LEM Part Number
DHAB S/133
Technology
Multirange Open Loop Hall Effect
ROHS
Yes
Supply Voltage
5 VDC
Load Current Channel 1 (RMS)
+/-75 Amp
Load Current Channel 2 (RMS)
+/-750 Amp
Output
0.25 - 4.75V (2.5Vref)
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth(-3dB)
DC - 1.1kHz
Mounting Style
Panel Mount/Cable Mount
Aperture
⌀22.5mm
Operating Temperature Range
-40°C - 70°C
CH1 Accuracy @ 25 Deg C
0.15%(0A),0.7%(37A),1.3%(75A)
Ch2 Accuracy @ 25 Deg C
1.4%(0A),7%(375A),10%(750A)
Termination Style
TYCO 1-1456426-5
Unit Weight
100g
Factory Pack Qty
6
Datasheet
Product Datasheet
Rishabh Rish Xmer 86-50 (45) 1200/5 Class 1 30VA Series Current Transformer
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
Rish Xmer 86-50 (45) 1200/5 Class 1
Technology
AC Current Transformer
Ratio
1200/5
Aperture Size
⌀ 46mm or 51 x 12mm Busbar
VA Rating
30VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
1200Amp x 1.2
Termination Style
Screw
Unit Weight
0.9kg
Factory Pack Qty
9
Datasheet
Product Datasheet
Rishabh Rish Xmer 140-100H (45) 2500/5 Class 1 Series Current Transformer
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
Rish Xmer 140-100H (45) 2500/5 Class 1
Technology
AC Current Transformer
Ratio
2500/5
Aperture Size
⌀ 86mm or 101 x 31mm Busbar
VA Rating
45VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
2500Amp x 1.2
Termination Style
Screw
Unit Weight
1.2kg
Factory Pack Qty
9
Datasheet
Product Datasheet
Varsi-Raycap V680E40, 680VAC, 895VDC, E40 Package, 1130W Metal Oxide Varistor (MOV), Equivalent to Epcos SIOV-B40K680 Features
Features
High Energy Absorption Rating
Industry Standard Package
Wide Operating Range 35 - 1100VAC
High Peak Current Capability (70kA)
UL/CSA/ROHS/ISO9001:2015 Approved
Panel Mount
Screw Terminals
APPLICATION AREAS:
1. Railways and trams: For the protection of electrical equipment, power electronics (IGBT, thyristors...) in systems with alternating, direct or combined AC + DC power supply, especially in power supply of AC/DC, DC/AC, DC/DC converters. They may be used in systems with main and auxiliary power supply for example: automatic control and regulation systems, cooling systems, warming systems, ventilation systems, and combination systems (electromechanical, electropneumatic and other systems).
2. Wind powerplants For protection of automatic control and regulation in power electronics (IGTB, tyristors...), as well as the protection of sensitive electronic systems (e. g. AC/DC, DC/AC, DC/DC converters, drive systems) from direct or indirect lightning strikes.
3. Photovoltaic systems For protection of photopanels, automatic control electronics with sensitive electronic components, and DC/AC converters (inverters) from direct or indirect lightning strikes. Depending on the application, both serial and parallel connections are possible. With serial connection the required voltage is achieved. With parallel connection higher current absorption is achieved in the modules.
Specification
Varsi-Raycap Part Number
V680E40
Operating Voltage AC (50-60Hz)
680V
Operating Voltage DC
895V
Average Power Dissipation
1.4W
Permissable Peak Current
40kA
Energy Absorption(2ms)
1130W(max)
Tolerance(Vn)
+/- 10%
Termination Style
Screw
Weight
73g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CSA
Yes
Datasheet
Product Datasheet
Application Notes
Technical Blog MOV Article
GDT/MOV/TVS Tester
SPD Tester