FPT-135 1000/5A 5P20 15VA Protection Class CT, 1000/5A, Class 5P20 15VA, 135 x 81mm Aperture
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2
Applications
Protection Relays
Safety Equipment
Fault Monitoring
??
Specification
Fastron Electronics Part Number
FPT-135 1000/5A 5P20 15VA
Technology
Protection Class Current Transformer
Ratio
1000/5
Aperture Size
81 x 135mm
VA Rating
15VA
Accuracy Class
Class 5P20
Output
5 Amp AC (?%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10??C / 50??C
Continuous Current (max)
1000Amp x 1.3
Termination Style
Screw
Stanbards
VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2
Unit Weight
3kg
Factory Pack Qty
1
??
Datasheet
Product Installation Guide and Datasheet
??
Beluk BLR-CX12R, Power Factor Regulator (Beluk BLR-CX 12RL), 12 Step, 110-480V 50/60HZ
Single CT Sensing
Isolated Switching of Power Factor Correction Contactors
Cos ϕ Setting 0.85 to 0.95 CAP
Auto CT Secondary Selection
Backlit LCD Display
Various Program Combinations
IP41
Up to 12 steps
Measurement System - Automatic/Manual
230VAC Aux Supply
Configurable Alarms
Dual Password Protection
Programmable Fan Control
Programmable 1A/5A CT Ratio
Specification
Beluk Part Number
BLR-CX12R
Function
Reactive Power Correction
Nominal Voltage (Un)
110-480VAC Line to Line
Supply Voltage
90-300VAC (L-N), 15VA 45-65Hz
Relay Rating
250VAC/10Amp
Switch Delay Time
1s - 1200s User Adjustable
Alarm
1 x Relay as above
Temperature Alarm
1 x Relay as above
Re-connection Delay Time
50 - 1200s User Adjustable
Desired Power Factor
0.80 IND - 0.80 CAP
Number of Output Relays
12
Smallest Capacitor Current
10mA
CT Input Range
0 - 6 Amp
LCD Display Accuracy
Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1
Phase Angle Error
+/- 1% at I > 3% of range
Comms
N/A
Termination Style
Screw
Weight
700g
Certification
IEC 654-1
Factory Pack Qty
1
Material of housing
PC/ABS Unflammable, according to UL 94 V-0
Enclosure protection
IP50 for case, IP20 for terminals
Safety
According to EN 61 010-1, installation category III Pollution degree 2
Operating Temperature
-20...60 °C
Datasheet
User Manual
Modbus RS485 User Manual
Quick Setup Guide
Comparison of CX and CX Plus Controllers
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
Quick Start Guide(Blog)
Crouzet 88974142, Millenium 3 Essential PLC XD10-6I/4O S, 6 x On/Off inputs, Incl 4 analogue inputs, 4 Solid State outputs incl 1 x PWM output, 24 VDC, EXPANDABLE
Highly visible blue LCD with 4 lines of 18 characters and configurable backlighting
Allow the use of the entire library of specific functions blocs of the software workshop
Extended temperature range (-20 °C →+70 °C)
Analogue inputs 0-10 VDC, Potentiometer, NTC, LDR (0-20 mA/Pt100 with converters)
Open to XN network communication extensions, digital I/O, analogue, Pt100 extensions
HMI Screens Available
Specification
Crouzet Part Number
88974142 (XD10-6I/4O S)
Analogue Inputs
0-10VDC (x4)
Digital Inputs
12/24VDC (4.4mA @ 12VDC) (x6)
Digital Outputs
4 x SSR 12/24VDC @ 500mA (x4)
PWM SSR Output
12-24VDC @ 500mA (x1)
Expandable
Yes
LCD Display
Yes
Mounting Style
DIN Rail Mount (71.2mm)
Supply Voltage Range
24VDC (21.6 - 28.8VDC)
Termination Style
Screw
Weight
250g
Certification
CE, UL, CSA, GL
Factory Pack Qty
1
Over Voltage Category
3 in accordance with IEC/EN 60664-1
Pollution Degree
2 in accordance with IEC/EN 61131-2
Protection rating
IP40 (Front), IP20 (Rear)
Mechanical Resistance
Immunity to vibrations IEC/EN 60068-2-6, test Fc
Immunity to shock IEC/EN 60068-2-27, test Ea
Resistance to HF Interference
Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12
Conducted and radiated emissions
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Operating Temperature
-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22
Datasheet
XD10-6I/4O Brochure
XD10-6I/4O Datasheet
Software
Crouzet Touch Soft V6.00.02.173
Software M3-soft-AC9-V3.1.2.0_ML
Remote Control Software CVD_PC_V2_3_01_02
Crouzet Soft EVO EM4 1.12.01.14
Fastron FTM1-A40-V4-W0, Single Phase, Phase Angle/Burst Controller for Primary Control of Transformer (Phase Angle mode only), Voltage/Current/Power Limit Modes, For Single Phase Loads, 400VAC, 32 Amps @ 50 Deg C, Modbus RTU
Features
Phase Angle, Distributed Burst, and Time Proportional Burst Control Functions
Made in China, Low cost
Single Phase, Angle/Burst Controller
4-20mA/0-10V/0-5V input Proportional Control
Phase Angle or Burst switching
Digital Display and Controls
Modbus RTU
Applications
Electrical Ovens, Kilns, or Furnaces
HVAC Heaters
Controlled Power Applications
Electric Boilers
Brewery Heating
Industrial Light Dimming
Suitable for HVAC or Industrial Environments
Specification
Fastron Part Number
FTM1-A40-V4-W0
Rated Operating Temperature
50°C
SCR Configuration
3 Phase AC Switch
Control Voltage
4-20mA/0-10V/0-5V/POT
Load Current
32 Amps Per Phase @ 50 Deg C
Derating
2% per 1 Deg C (approx)
Control Range
0-100%
Alarms
1 x NO Relay Contacts
Special Feature
Internal Fuse, Current Limit, Power Limit
Comms
Modbus RTU
Mounting Style
Panel Mount
Switching Voltage Range
400VAC +/-10%
Supply Voltage
230VAC +/-10%
Dimensions
H:260mm W:94mm D:187mm
Soft Start
N/A
Termination Style
Screw
Unit Weight
2.5kg (4kg Packed)
Factory Pack Qty
1
Technical Docs
User Manual
Brochure
Video for How to Set Current/Voltage/Power limit
FPT-80 800/1A 5P20 7.5VA, Protection Class CT, 800/1A, Class 5P20 7.5VA, 83 x 56mm Aperture
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2
Applications
Protection Relays
Safety Equipment
Fault Monitoring
Specification
Fastron Electronics Part Number
FPT-80 800/1A 5P20 7.5VA
Technology
Protection Class Current Transformer
Ratio
800/1
Aperture Size
83 x 56mm
VA Rating
7.5VA
Accuracy Class
Class 5P20
Output
1 Amp AC
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10 Deg C / 50 Deg C
Continuous Current (max)
800Amp x 20
Termination Style
Screw
Stanbards
VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2
Unit Weight
1.5 kg
Factory Pack Qty
1
Datasheet
Product Installation Guide and Datasheet
LEM AHR 2000 B420, Hall Effect Current Transducer, 2000A, 4-20mA True RMS output, 20-50VDC supply
Compact and versatile transducers for high AC and DC currents from 500 to 2000A True RMS with signal conditioning. Choice of output types: 4-20 mA, 0-5 V or 0-10 V, Bandwidth: DC 20..6000 Hz
Features
Split Core
VFD and SCR waveforms current measurement
True RMS output
4-20mA current output
Busbar mounting
Eliminates insertion loss
Isolated plastic case recognised according to UL94-V0
Advantages
Large aperture for cable or busbar up to 104 x 40mm
High isolation between primary and secondary circuits
Easy installation
Applications
-AC Power Supplies or Motors
True RMS sensing - the most accurate way to monitor power supply or input power
-VFD Controlled Loads
VFD output indicates how the motor and attached load are operating
-SCR Controlled Loads
Accurate measurement of phase angle fired or burst fired(time proportional) SCR's and switch mode rectifiers. Current measurement gives faster response than temperature measurement.
-Renewable Energy Installations or Backup Batteries
Continuous condition monitoring allowing automatic failure detection and prediction
-Application Domain
Energy and Automation
Specification
LEM Part Number
AHR 2000 B420
Technology
Open Loop Hall Effect
ROHS
Yes
Supply Voltage
20 - 50V
Nominal Current (RMS + DC)
2000 Amp
Maximum Measurement Current (Peak)
3000 Amp
Output
4-20mA
Isolation
5.8kV (AC, 50Hz, 1 min)
Bandwidth
20-6000Hz
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
SFKC 2.5/4-ST-5.08-RF(Phoenix Contact)
Unit Weight
650g
Factory Pack Qty
6
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Fastron Electronics FESCT-055-200-1-IP65, 200Amp Measurement, 1 Amp Output Split Core CT's, Class 1, w/10M Flying leads, ø 55mm Aperture
Features
Quick Release Split Core System
10m Flying Leads
ø 55mm
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.60/3kV
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurement, 1 Amp Outputs
Specification
Fastron Electronics Part Number
FESCT-055-200-1-IP65
Technology
Split Core AC Current Transformer
Ratio
200/5A
Aperture Size
ø 55mm
VA Rating
2.5VA
Accuracy Class
Class 1
Output
1 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Dimensions
180x138x52mm
Mounting Style
Panel Mount
Operating Temperature Range
-35°C / 55°C
Continuous Current (max)
200Amp x 1.2
Termination Style
10M Twisted Pair 0.34mm^2
Unit Weight
2000g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Fastron FTM1-A05-V2-W0, Single Phase, Phase Angle/Burst Controller for Primary Control of Transformer (Phase Angle mode only), Voltage/Current/Power Limit Modes, For Single Phase Loads, 230VAC, 4 Amps @ 50 Deg C, Modbus RTU
Features
Phase Angle, and Burst Control Functions
Made in China, Low cost
Single Phase, Angle/Burst Controller
4-20mA/0-10V/0-5V input Proportional Control
Phase Angle or Burst switching
Digital Display and Controls
Modbus RTU
Applications
Electrical Ovens, Kilns, or Furnaces
HVAC Heaters
Controlled Power Applications
Electric Boilers
Brewery Heating
Industrial Light Dimming
Suitable for HVAC or Industrial Environments
Specification
Fastron Part Number
FTM1-A05-V2-W0
Rated Operating Temperature
50°C
SCR Configuration
3 Phase AC Switch
Control Voltage
4-20mA/0-10V/0-5V/POT
Load Current
4 Amps Per Phase @ 50 Deg C
Derating
2% per 1 Deg C (approx)
Control Range
0-100%
Alarms
1 x NO Relay Contacts
Special Feature
Internal Fuse, Current Limit, Power Limit
Comms
Modbus RTU
Mounting Style
Panel Mount
Switching Voltage Range
230VAC +/-10%
Supply Voltage
230VAC +/-10%
Dimensions
H:260mm W:94mm D:187mm
Soft Start
N/A
Termination Style
Screw
Unit Weight
2.5kg (4kg Packed)
Factory Pack Qty
1
Technical Docs
User Manual
Brochure
Video for How to Set Current/Voltage/Power limit
F921 DC Series Current Transducer 100mA to 400 Amp Range with Adjustable High and Low C/O Relay Alarm
Features
Isolated measurement of DC currents using a Hall effect transducer with external aperture.
Incorporates an integrated input level display and power supply.
Wide measurement range available
Choice of standard outputs
Wide range isolated DC input supply
DIN Rail mounting
Signal Conditioned DC measurement output
On board bar graph display
User adjustable zero offset and span controls
Zero insertion loss in current measurement path
Earth leakage via differential Ipn for nominal Input ‘01’
Applications
Process control
Transportation
Petrochemical
Industrial
Earth Leakage
Energy Monitoring/Measurement
Automation
Delivery
Delivery in 3-5 days for small qty. Otherwise 4-6 weeks
Specification
Oztherm Part Number
F921-X-XX-DC-XX-XX
Functions
Single Phase AC Current Transducer
Supply Voltage
9-36VDC
Nominal Measurement Range
0-400 Amp (Sensor dependant)
Maximum Measurement Range
2500 Amp with External Sensor
Alarm
C/O Relay 4Amp @ 30VDC, 0.5Amp @ 150VAC
Response Time
250mS
Accuracy @ 25 Deg C
Class 1
Bandwidth
DC - 1kHz
linearity
< 0.15%
Isolation
2.5kV
Comms
N/A
Weight
250g
Enclosure Size
79 x 60 x 85mm
Factory Pack Qty
1
EU Directives
N/A
Safety
Protection Class II
600V rms, installation category II
300V rms, installation category III
Pollution Degree 2 in compliance with SIST EN 61010-1:2002
Enclosure Material
Polyamide non combustable-self-extinguishability, complying with UL 94 V-0
Enclosure Protection
IP40
Shock Withstand
300g 8ms Pulse . 6 Shocks in each of 3 axes
Vibration Withstand
0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
Shinko RAU-O Series Signal Conditioners
Universal Input (Thermocouple, RTD, DC Current, DC Voltage, Potentiometer) Signal Conditioner 100-240 VAC, 4-20mA output
4-digit display. Suit most industries including Temperature, Humidity, Pressure (0.25s response)
Tropicalised Version Available
UL/CSA Approved
Input signals can be converted to insulated 4 to 20 mA DC output (0.25s Response)
Each unit needs just 22.5mm width Din Rail space
EC Compliant (Details)
Specification
Shinko Part Number
RAU-O
Control Output
4-20mA Output
Input
Universal (TC, RTD, DC Amp, DC Volt, POT)
Special Function
3 Port Isolation for noisy environments
Option
RS485 Comms
Mounting Style
22.5 x 75mm Din Rail Mount
Supply Voltage
100 - 240VAC
Termination Style
Screw
Weight
230g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Datasheet
RA Series Brochure
RA Series User Manual
Delivery 2-3 weeks delivery if not in stock
FPT-50 200/5A 5P20 1.5VA, Protection Class CT, 200/5A, Class 5P20 1.5VA, 52.3 x 32.2mm Aperture
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2
Applications
Protection Relays
Safety Equipment
Fault Monitoring
Specification
Fastron Electronics Part Number
FPT-50 200/5A 5P20 1.5VA
Technology
Protection Class Current Transformer
Ratio
200/5
Aperture Size
52.3 x 32.2mm
VA Rating
1.5VA
Accuracy Class
Class 5P20
Output
5 Amp AC
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10 Deg C / 50 Deg C
Continuous Current (max)
200Amp x 20
Termination Style
Screw
Stanbards
VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2
Unit Weight
1.2 kg
Factory Pack Qty
1
Datasheet
Product Installation Guide and Datasheet
FPT-80 500/1A 5P20 5VA, Protection Class CT, 600/5A, Class 5P20 2.5VA, 83 x 56mm Aperture
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2
Applications
Protection Relays
Safety Equipment
Fault Monitoring
Specification
Fastron Electronics Part Number
FPT-80 500/1A 5P20 5VA
Technology
Protection Class Current Transformer
Ratio
500/1
Aperture Size
83 x 56mm
VA Rating
5VA
Accuracy Class
Class 5P20
Output
1 Amp AC
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10 Deg C / 50 Deg C
Continuous Current (max)
500Amp x 20
Termination Style
Screw
Stanbards
VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2
Unit Weight
1.5 kg
Factory Pack Qty
1
Datasheet
Product Installation Guide and Datasheet