Search results for "����ٸ������� �νν������� SSSREO �Ť�H���� ��ǰ����� �̷�����Ʈ��õ ĥ��ְ�����Ƽ �̷��� ���ø�ī �����÷���"
-
DR2260A20V, Solid State Contactor SSR, Single Phase 90-280VAC Control, 20A, 48-600VAC Load, Din Rail Mount
Free Aus Post Shipping for $300 SpendCrydom DR2260A20V, Solid State Contactor SSR, Single Phase 90-280VAC Control, 20A, 48-600VAC Load, Din Rail Mount Features Ratings from 20A to 35 Amp @ 48-660 VAC Contactor Style for retrofit SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CSA/VDE Approved, CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriers AC & DC control types Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Crydom Part Number DR2260A20V Switching Type Zero Crossing ROHS Yes (Details) Control Voltage 90-280VAC Load Current (single unit) 20 Amp (rms) @ 40 Deg C Ambient, 16 Amp (rms) @ 50 Deg C Ambient Load Current (multiple units) 20 Amp (rms) @ 40 Deg C Ambient, 16 Amp (rms) @ 50 Deg C Ambient Surge Capability 286 Amp (peak) Special Feature Contactor Style Terminals Mounting Style DIN Rail Mount Load Voltage Range 48 - 660VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 298g Factory Pack Qty 20 Datasheet Product Datasheet Alternatives SSR Style CKRD4830 App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
Thyro S 1S Series Single Phase SCR Controller 16 - 1500Amp 500VAC Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes
Advanced Energy Thyro S 1S Series Single Phase SCR Power Controller, Phase(VAR), Burst(TAKT), Quick TAKT(QTM), SWITCH Operating Modes. Compatible Replacement for Erutotherm Features Optional Profinet,Profibus,Ethernet,Modbus Comms 500VAC +10/-57% Voltage, Current or Power Control Built in Fuse Smallest footprint on the market Single Phase Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes Quick TAKT Mode (QTM), VT Mode (on request) (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover Potentiometer Adjustment USB Configuration/Bias Setting Synchronisation Function (dASM Module Recommended) Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode AC Soft Starter (Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro S 1S 500VAC Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Single Phase AC Switch Control Modes Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request) Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 500VAC +10/-15% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 30kg Factory Pack Qty 1 Technical Docs Brochure User Manual Thyro A Series Quick Installtion Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$932.50 - $2,882.00
-
HS501DR + HA4850, Panel or Din Rail Mount Solid State Relay, 90-280VAC Control Input, 90-530VAC Output, 10 Amps
Free Aus Post Shipping for $300 SpendCrydom HS501DR + HA4850, Panel or Din Rail Mount Solid State Relay, 90-280VAC Control Input, 90-530VAC Output, 10 Amps Features Ratings from 25A to 125 Amp @48-530 VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CE/ROHS Compliant Direct bond copper substrate Direct power lead frame Epoxy free design Spec Part Number HS501DR + HA4850 Switching Type Zero Crossing ROHS/CE/UL Yes Control Voltage 90-280VAC Load Current 10 Amp (rms) @ 40 Deg C Surge Capability 597 Amp (peak) Special Feature LED Status Indicator Mounting Style Din Rail or Panel Mount Load Voltage Range 48-530VAC Max Non Repetitive Peak Voltage 600 Vp Termination Style Screw Terminals Dimensions L:79.9mm x W:45mm x D:40.3mm Unit Weight 296g Factory Pack Qty 20 Datasheet HS501DR Series 1 HD Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
HD4890, Solid State Relay, Single Phase 3-32VDC Control, 90A, 48-530VAC Load
Free Aus Post Shipping for $300 SpendCrydom HD4890, Solid State Relay, Single Phase 3-32VDC Control, 90A, 48-530VAC Load Features Ratings from 25A to 125 Amp @ 48-533VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CSA/VDE Approved, CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriers AC & DC control types Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Crydom Part Number HD4890 Switching Type Zero Crossing ROHS Yes (Details) Control Voltage 3-32VDC Load Current 90 Amp (rms) Surge Capability 1145 Amp (peak) Special Feature None Mounting Style Panel Mount Load Voltage Range 48-530VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 75g Factory Pack Qty 20 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
D2425, SSR Single Phase 3-32VDC Control, 25A, 24-280VAC Load
Free Aus Post Shipping for $300 SpendCrydom D2425, SSR Single Phase 3-32VDC Control, 25A, 24-280VAC Load Features Ratings from 25A to 125 Amp @ 24-280 VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CSA/VDE Approved, CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriers AC & DC control types Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Crydom Part Number D2425T Switching Type Zero Crossing ROHS Yes (Details) Control Voltage 3-32VDC Load Current 25 Amp (rms) Surge Capability 239 Amp (peak) Special Feature N/A Mounting Style Panel Mount Load Voltage Range 24-280VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 75g Factory Pack Qty 20 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here Equivalent D2450 HD4850 CY9008 CWD2450P HD6050 App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
HS122DR, Din Rail Mount Heatsink, 1.2 Deg C per Watt For 1 or 2 single phase Solid State Relay,
Free Aus Post Shipping for $300 SpendCrydom HS122DR, Din Rail Mount Heatsink for Solid State Relays, 1.2°C/W Features DIN Rail or Panel Mount heat sink types Suitable for SSR Mounting Pre drilled for 1 pr 2 single phase SSR Black anodised for professional look Spec Crydom Part Number HS122DR Mounting Type Din Rail Suitable SSR Rating 50 Amp Dimensions (without SSR) L:97mm x W:90mm x 86.5mm Thermal Impedance 1.2°C/W Load Current @ 40 Deg C 45 Amp Load Current @ 50 Deg C 37.5 Amp Unit Weight 437g Factory Pack Qty 10 Datasheet Product Datasheet App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
MC774 S HEWNNN, Power Quality Analyser Class A, 32uS sampling, 16-400Hz, Time Sychronisation support, 80-276VAC or 70-300VDC Power Supply, Three Independent Comm Ports, GPS, IRIG-B, and NTP Time, Up to 20 Input and Outputs, Ethernet and USB Comms
Free Aus Post Shipping for $300 SpendIskra Doo MC774 S HEWNNN, Power Quality Analyser Class A, 32uS sampling, 16-400Hz, 140 Parameter Measurement, Time Sychronisation support, 80-276VAC or 70-300VDC Power Supply, Three Independent Comm Ports, GPS, IRIG-B, and NTP Time, Up to 20 Input and Outputs, Ethernet and USB Comms, 1 x Status and 1 x Relay Output Class A Instrument Automatic range of nominal current up to 12.5 A (Includes 5A/1A CT Input) and nominal voltage up to 1000rms V L-N 50/60Hz Adjustable tariff clock, display of electric energy consumption in optional currency Optional RS 232/RS 485 communication up to 115,200 bit/s or Ethernet communication The POwer Quality Analyser is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : Measurement of instantaneous values of more than 140 quantities (U, I, P, Q, S, PF, PA, f, f, MD, energy, energy price by tariffs, etc.). Accuracy class 0.5 or 0.2 (on demand) Measurement of 40 minimal and maximal values in different time periods Optional 32 adjustable alarms Optional wide frequency range from 16 Hz to 400 Hz Optional RS 232/RS 485 communication up to 115,200 bit/s or Ethernet communication Optional MODBUS and DNP3 communication protocol MMC memory card for setting and upgrading the meter Up to 20 inputs or outputs (analogue outputs, pulse outputs, alarm outputs, tariff inputs) 1 Status and 1 Relay Output Universal or AC power supply Graphic LCD 128 x 64 dots with illumination Automatic range of nominal current up to 5 A and nominal voltage up to 750 V Adjustable tariff clock, display of electric energy consumption in optional currency Multilingual support User-friendly PC MiQen software 128 samples in one period Measurement of THD on Current or Voltage from 0 to 400% Measure to the 65th Harmonic Specification Iskra Doo Part Number MC774 S HEWNNNT Functions Power Quality Analyser, Energy Meter, Power Transducer, Network Recorder/Analyser Supply Voltage 240VAC < 5VA Nominal Measurement Range 750Vrms L-N, 5 Amp 50/60Hz Maximum Measurement Range 1000Vrms L-N, 12.5 Amp 50/60Hz Alarm N/A (Optional 4 Relays, 32 Alarms, 4 Groups) Analogue Output N/A (Optional 4 x 20mA) Digital Input N/A (Optional 4 x 230VAC/DC,75..130VAC/DC..5..48VAC/DC) Pulse Output N/A (Optional) Pulse Input N/A (Optional) Bistable Switch/Latching Relay Alarm N/A (Optional) Status (Watchdog) Output N/A (Optional) Tariff Input N/A (Optional 4 x 230VAC/DC,75..130VAC/DC..5..48VAC/DC) Accuracy Class 0.5 (I,U,F,PF,θ,THD) (Class 0.2 Optional) Class 1(Active), Class 2 (Reactive) Battery Backup Supercap Real Time Clock 1min/month (30ppm) Internal Memory 8MB MMC up to 1GB Isolation 3.7kV Ethernet Yes (RJ45 10/100Mbit/s) USB Yes (2400-115200 b/s) RS232/RS485 Optional Weight 600g Certification UL, CSA, ROHS Factory Pack Qty 1 EU Directives Degree on electrical equipment designed for use within certain voltage limits URLRS 53/00 (Directive 73/23/EEC on low voltage): SIST EN 61010-1:2002 Safety Requirement for electrical equipment for measurement, control and laboratory use, part1 : general requirement Decree on electromagnetic Compatibility (EMC) URLRS 61/00 (Directive 89/336/EEC on electromagnetic compatibility): SIST EN 61036 item 4.5: 1998 Meters for active energy (class 1 and 2) Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP52 (IP00 for terminals) in compliance with SIST EN 60529:1997 Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22 Datasheet Product Datasheet User Manual
-
D1D60, 3-32VDC Input, 100V, 60Amp DC Output Solid State Relay
Free Aus Post Shipping for $300 SpendCrydom D1D60, 3-32VDC Input, 100V, 60Amp DC Output Solid State Relay Features Ratings from 7A to 100 Amp @ 100-500VDC Mosfet output for reliable DC switching Multiple modules can be wired in parallel for higher currents UL/CSA/VDE Approved, CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriers Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Crydom Part Number D1D60 Switching Type DC Load ROHS Yes (Details) Control Voltage 3.5-32VDC Load Current 60 Amp DC Surge Capability (10ms) 180 Amp DC Special Feature None Mounting Style Panel Mount Load Voltage Range 0 - 100VDC EMC Compliant Level 3 Termination Style Screw Unit Weight 75g Factory Pack Qty 20 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
PF480D25, SSR SIP, 4-15VDC Control, 25A, 48-530VAC Load
Free Aus Post Shipping for $300 SpendCrydom PF480D25, SSR SIP, 4-15VDC Control, 25A, 48-530VAC Load Features Ratings up to 25 Amp @ 660VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CSA/VDE Approved, CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriers AC & DC control types Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Crydom Part Number PFE480D25 Switching Type Zero Crossing ROHS Yes (Details) Control Voltage 4-15VDC Load Current 25 Amp (rms) Surge Capability 250 Amp (peak) Special Feature None Mounting Style PCB Mount Load Voltage Range 48-480VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 25g Factory Pack Qty 20 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here Accessories Din Rail Holder App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement
-
CMRD6055, Solid State Relay, Single Phase 3.5-32VDC Control, 55A, 48-660VAC Load, Din Rail
Free Aus Post Shipping for $300 SpendCrydom CMRD6055, Solid State Relay, Single Phase 3.5-32VDC Control, 55A, 48-660VAC Load, Din Rail Features • Ratings from 35A to 65Amp @ 48-660 VAC • SCR output for heavy industrial loads • Zero voltage or instantaneous turn-on outputs • UL/CSA/VDE Approved, CE Compliant to EN60950-1 • Improved SEMS screw and washer • Redesigned housing with anti-rotation barriers • AC & DC control types • Direct bond copper substrate • EMC compliant to Level 3 • Direct power lead frame • Epoxy free design Spec Crydom Part Number CMRD6055 Switching Type Zero Crossing ROHS Yes (Details) Control Voltage 4-32VDC Load Current 55 Amp (rms) Surge Capability 710 Amp (peak) Special Feature None Mounting Style DIN Rail Mount Load Voltage Range 48 - 660VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 500g Factory Pack Qty 20 Datasheet Product Datasheet App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
HDC200D160, 3.5-32VDC Input, 7-150V, 160Amp DC Output Solid State Relay
Free Aus Post Shipping for $300 SpendCrydom HDC200D160, 3.5-32VDC Input, 7-150V, 160Amp DC Output Solid State Relay Features Ratings from 100A to 160 Amp @ 7-150VDC Mosfet output for reliable DC switching Multiple modules can be wired in parallel for higher currents UL/CSA/VDE Approved, CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriers Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Crydom Part Number HDC200D160 Switching Type DC Load ROHS Yes (Details) Control Voltage 3.5-32VDC Load Current 160 Amp DC Surge Capability (10ms) 470 Amp DC Special Feature High Current Stud Terminals Mounting Style Panel Mount Load Voltage Range 7 - 150VDC EMC Compliant Level 3 Termination Style Screw Unit Weight 345g Factory Pack Qty 20 Datasheet Product Datasheet App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
DR2260A35U, Solid State Relay 4-32VDC Control, 35A, 48-600VAC Load, Din Rail Mount, w/status LED
Free Aus Post Shipping for $300 SpendCrydom DR2260A35U, Solid State Relay 4-32VDC Control, 35A, 48-600VAC Load, Din Rail Mount, w/status LED Features Ratings from 20 Amp up to 35 Amp @ 600 VAC Mosfet output for heavy industrial loads UL/CSA/VDE Approved, CE Compliant to EN60950-1 Din Rail Mount with bonded Heat sink Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Crydom Part Number DR2260D35U Switching Type Zero Crossing ROHS Yes (Details) Control Voltage 4 - 32VDC Load Current (single unit) 35 Amp (rms) @ 45 Deg C Ambient, 28 Amp (rms) @ 50 Deg C Ambient Load Current (multiple units) 25 Amp (rms) @ 40 Deg C Ambient, 20 Amp (rms) @ 50 Deg C Ambient Surge Capability 1290 Amp RMS Special Feature None Mounting Style DIN Rail Mount Load Voltage Range 48-600VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 298g Factory Pack Qty 20 Datasheet Product Datasheet App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies