GT-DVO(0-100V)D-1, DC Voltage Transducer, 0-100VDC input, 22-60VAC/DC aux, 4-20mA output
Fastron Electronics GT-DVO(0-100V)D-1, DC Voltage Transducer, 0-100VDC input, 22-60VAC/DC aux, 4-20mA output Adjustable Zero and Span Setting 250mS Response Time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space Specification Fastron Electronics Part Number GTD-DVO(0-100V)D-1 Control Output 4-20mA Input 0 - 100VDC Over Range x 1.5 Operating Temperature 0 - 60°C Load Voltage 22 - 60VDC Span Adjustment Range +/-10% Zero Adjustment Range +/-5% Termination Style Screw Mounting Style DIN Rail Mount Case Material PC - UL 94 V0 Weight 170g Factory Pack Qty 1  Datasheet Product Datasheet
$219.00
$258.42 inclGST -
GT-DVO(5-15V)A-1, DC Voltage Transducer, 5-15VDC input, 100 - 240VAC/DC aux, 4-20mA output
Free Aus Post Shipping for $300 SpendFastron Electronics GT-DVO(5-15V)A-1, Signal Isolator/DC Voltage Transducer, 5-15VDC input for Battery Voltage Monitoring, 100 - 240VAC/DC aux, 4-20mA output Adjustable Zero and Span Setting 250mS Response Time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space Specification Fastron Electronics Part Number GT-DVO(5-15V)A-1 Control Output 4-20mA Input 5-15VDC Over Range x 1.5 Operating Temperature 0 - 60°C Load Voltage 100 - 240VAC/DC Span Adjustment Range +/-10% Zero Adjustment Range +/-5% Termination Style Screw Mounting Style DIN Rail Mount Case Material PC - UL 94 V0 Weight 170g Factory Pack Qty 1  Datasheet Product Datasheet
Free Aus Post Shipping for $300 Spend$219.00
$258.42 inclGST -
SCT-F36-250, 0.333V, 250Amp Measurement, Class 1 Split Core CT's Class 1, 35mm Aperture
Fastron Electronics SCT-F36-250, 0.333V, 250Amp measurement Split Core CT's Class 1, 36mm Aperture Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F36-250 Technology Split Core AC Current Transformer Ratio 250/0.333V Aperture Size ø 35 mm VA Rating N/A Accuracy Class Class 1 Output 0.333V (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 250Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$66.50
$78.47 inclGST -
FPT-135 800/1A 5P35 5VA, Protection Class CT, 800/1A, Class 5P35 5VA, 135 x 81mm Aperture
Heavy Item - No Free ShippingFPT-135 800/1A 5P35 5VA Protection Class CT, 800/1A, Class 5P35 5VA, 135 x 81mm Aperture Features Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2 Applications Protection Relays Safety Equipment Fault Monitoring ?? Specification Fastron Electronics Part Number FPT-135 800/1A 5P35 5VA Technology Protection Class Current Transformer Ratio 800/5 Aperture Size 81 x 135mm VA Rating 5VA Accuracy Class Class 5P35 Output 1 Amp AC (?%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10??C / 50??C Continuous Current (max) 800Amp x 1.3 Termination Style Screw Stanbards VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2 Unit Weight 7kg Factory Pack Qty 1 ?? Datasheet Product Installation Guide and Datasheet ??
Heavy Item - No Free Shipping$505.00
$595.90 inclGST -
TTH-32-SA3-3, Relative Humidity Sensor and Transmitter, 500 x 6mm w/3M Cable
Free Aus Post Shipping for $300 SpendFastron TTH-32-SA3-3, Relative Humidity Sensor and Transmitter, 500 x 6mm w/3M Cable 1 x 4-20mA Output 2 Wire Humidity Measurement for RH 0 to 100 % Long Term Stability <2% RH per year 300 x 6mm with 3M Cable 20 Second Response Time 12-30VDC Supply 150mA max Thin Film Capacitor Sensing Elements Specification Fastron Part Number TTH-32-SA3-3 Sensor Type Thin Film Capacitor (Humidity) No of Wires 2 Shaft Length 500mm Shaft Thickness 6mm Approvals CE, ROHS Cable length 1 Meter Temperature Range 0 to 100 Deg C Mounting Style Through Hole Weight 45g Factory Pack Qty 1 Datasheet Datasheet Installation Guide Wiring Diagram
Free Aus Post Shipping for $300 Spend$279.00
$329.22 inclGST -
SCT-F16-100-5A, 100/5Amp Measurement, Class 1 Split Core CT's
Fastron Electronics SCT-F16-100-5A, 5 Amp Output, 100Amp measurement Split Core Current Transformer Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.5M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements  Specification Fastron Part Number SCT-F16-100-5A Technology Split Core AC Current Transformer Ratio 100/5A Aperture Size ø 15 mm VA Rating 1VA Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 100Amp x 1.2 Termination Style 0.5M Flying leads Unit Weight 100g Factory Pack Qty 9  Datasheet Product Datasheet Application Notes Installation Guide
$45.00
$53.10 inclGST -
TSFFNCR-100, 100 Deg C, NC Thermal Switch 10 Deg C Hysteresis, +/-2% Tolerance, Fixed Flange Mount, with 90 Deg Raised Terminals
100 Deg C Normally Closed Thermal Switch 10 Deg C Hysteresis, +/-2% Tolerance, Fixed Flange Mount, with 90 Deg Raised Terminals, KSD302, R20 Datasheet Product Datasheet
$8.50
$10.03 inclGST -
DR24D06, Solid State Relay, 4-32VDC control, 6 Amp 24-280VAC Output, Slimline, Din Rail Mount, LED status Indicator
Crydom DR24D06, Solid State Relay, 4-32VDC control, 6 Amp 24-280VAC Output, Slimline, Din Rail Mount, LED status Indicator Features Ratings from 3 Amp, 6 Amp, 12 Amp 1-100VDC, 1-60VDC, 24-280VAC, 48-600VAC DIN Rail Mount SCR output for reliable AC switching, or Mosfet for DC Switching Ultra slim package UL/CSA/VDE Approved, CE Compliant to EN60950-1 EMC compliant to Level 3 Epoxy free design Spec Crydom Part Number DR24D06 Switching Type DC ROHS Yes (Details) Control Voltage 4-32VDC Load Current 6 Amp (rms) Surge Capability (10ms) 285 Amp (rms) Special Feature LED Status Indicator Mounting Style DIN Rail Mount Load Voltage Range 24-280VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 50g Factory Pack Qty 20 Â Datasheet Product Datasheet Equivalent Similar part ks32-60-24z2-f41f-1z-c2-4Â App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
$109.00
$128.62 inclGST -
TSFFNCR-110, 110 Deg C, NC Thermal Switch 10 Deg C Hysteresis, +/-2% Tolerance, Fixed Flange Mount, with 90 Deg Raised Terminals
110 Deg C Normally Closed, Thermal Switch 10 Deg C Hysteresis, +/-2% Tolerance, Fixed Flange Mount, with 90 Deg Raised Terminals, KSD301, R20 Datasheet Product Datasheet
$8.50
$10.03 inclGST -
PMP2490WP, Phase/Burst control, 240VAC, 90 Amp, Selectable 0-5V,0-10V,4-20mA input, w/Overvoltage Protection
Crydom PMP2490WP, Phase/Burst control, 240VAC, 90 Amp, Selectable 0-5V,0-10V,4-20mA input, w/Overvoltage Protection Features Selectable Proportional Phase or Burst Control Input Ratings from 25A to 90 Amp @ 170-600 VAC SCR output for heavy industrial loads Zero voltage or Instantaneous turn-on outputs UL/CE/ROHS Compliant Direct bond copper substrate Direct power lead frame Epoxy free design Spec Crydom Part Number PMP2490WP Switching Type Phase Angle or Burst (Selectable) ROHS/CE/UL Yes Control Voltage 0 - 10V/0 - 5V/4 - 20mA Proportional Input (Selectable) Note Requires DC Power Supply for 0-5V/0-10V input modes Load Current 90 Amp (rms) Surge Capability 1290Amp (peak) Special Feature Proportional Controller + SSR Mounting Style Panel Mount Load Voltage Range 170-280VAC Dielectric Strength 4kV Termination Style Terminal Plug Unit Weight 160g Factory Pack Qty 20 Â Datasheet Product Datasheet PMP24 Installation/Wiring Guide Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here Equivalent FTY220D80P Contact Us for Possible Replacement PMP24 Installation/Wiring Guide Heatsink SSR and Heatsink Assemblies App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement
$272.00
$320.96 inclGST -
TSFFNCR-155, 155 Deg C, NC Thermal Switch 10 Deg C Hysteresis, +/-2% Tolerance, Fixed Flange Mount, with 90 Degree Raised Terminals
155 Deg C, NC Thermal Switch 10 Deg C Hysteresis, +/-2% Tolerance, Fixed Flange Mount, with 90 Degree Raised Terminals Datasheet Product Datasheet
$10.50
$12.39 inclGST -
TC5-H-1A-2-T/R-2 PID Controller, 100-240VAC with 2 3 Amp Relay Alarms, K,E,J Thermocouple, Pt100 or Cu20, Optional Linear Current/Voltage, 48x96mm,4-20mA Output
Fastron TC5-H-1A-2-T/R-2 PID Controller, 100-240VAC with 2 3 Amp Relay Alarms, K,E,J Thermocouple, Pt100 or Cu20, Optional Linear Current/Voltage, 48x96mm,4-20mA Output 4-digit displays (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available Each unit needs just 75 mm depth panel space Now available will full Multirange input (K,E,J Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 96x48mm,4-20mA Output) Specification Fastron Part Number TC5-H-1A-2-T/R-2 Control Output 4-20mA Input Multirange Type,K,E,J, Pt100, Cu50/(Optional)Linear Current 4(0)-20mA/(Optional)Linear Voltage 0-10(5)V Option 1 2 3 Amp Relay Alarms standard (Excludes 48x96mm with SSR/Relay output) Mounting Style 96x48mm Panel Mount Supply Voltage 100 - 240VAC +/-10% Termination Style Screw Sampling Time 100ms Weight 150-270g Factory Pack Qty 10 Datasheet TC5 Datasheet and User Manual
$137.00
$161.66 inclGST