Fastron FC5-H-1U-1-G-2-C PID Controller, 100-240VAC with 1 Alarm, RS485, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 48x96mm, 0-10V Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
FC5-H-1U-1-G-2-C
Control Output
0-10V
Input
Multirange K,E,J,N,T,S,R,B Thermocouple, PT100/Cu20 RTD Input/Linear Current 4(0)-20mA/Linear Voltage 0-10(5)V
Option 1
1 Alarm, RS485 standard (Excludes 48x96mm with SSR/Relay output)
Mounting Style
48x96mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet & User Manual
Datasheet
User Manual
FC5 Communication Protocol
Northern Design XD-R420-2, Current Transducer, True RMS, Ipn = Selectable 5,10,15,20,25,30 Amp, 4-20mA out,16-36VDC Loop powered
Features
Ipn = Selectable 5,10,15,20,25,30 Amp
True RMS Output
4-20mA Current Output
Din Rail Mounting
16-36VDC Loop Powered
Isolated plastic case recognised according to UL94-V0
Advantages
Large aperture for cable up to ⌀ 16mm
High isolation between primary and secondary circuits
Easy installation
Applications
Current Measurement
Energy Management
Earth Leakage Measurement
Motor Control
Actuators
Lamp Failure
Specification
Northern Design Part Number
XD-R420-2
Technology
AC Current Transformer
Protection Class
IP50
Supply Voltage
16-36VDC Loop Powered (10mA)
Load Current (RMS)
Selectable 5,10,15,20,25,30 Amp
Output
4-20mA (True RMS)
Isolation
4kV (AC, 50Hz, 1 min)
Bandwidth
55 - 65Hz
Mounting Style
Din Rail Mount
Operating Temperature Range
-10°C / 65°C
Accuracy
Class 1
Termination Style
Screw
Unit Weight
180g
Factory Pack Qty
6
Datasheet
Product Brochure
Product Manual
Application Notes
Fastron FC5-S-R-1-G-4-C PID Controller, 24VDC with 1 Alarm, RS485, K,E,J,N,T,S,R,B Thermocouple, Pt100 or Cu20, Optional Linear Current/Voltage, 48x48mm,Relay Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
FC5-S-R-2-T/R-2
Control Output
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Input
Multirange Type,K,E,J,N,T,S,R,B, Pt100, Cu50/(Optional)Linear Current 4(0)-20mA/(Optional)Linear Voltage 0-10(5)V
Option 1
1 Alarm, RS485 standard (Excludes 48x48mm with SSR/Relay output)
Mounting Style
48 x 48mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet
Datasheet
User Manual
Modbus Protocol
FC5 Communication Protocol
FPT-135 3000/1A 5P20 15VA Protection Class CT, 3000/1A, Class 5P20 15VA, 135 x 81mm Aperture
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2
Applications
Protection Relays
Safety Equipment
Fault Monitoring
??
Specification
Fastron Electronics Part Number
FPT-135 3000/1A 5P20 15VA
Technology
Protection Class Current Transformer
Ratio
3000/5
Aperture Size
81 x 135mm
VA Rating
15VA
Accuracy Class
Class 5P20
Output
1 Amp AC (?%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10??C / 50??C
Continuous Current (max)
3000Amp x 1.3
Termination Style
Screw
Stanbards
VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2
Unit Weight
7kg
Factory Pack Qty
1
??
Datasheet
Product Installation Guide and Datasheet
??
FPT-135 800/1A 5P20 10VA Protection Class CT, 800/1A, Class 5P20 10VA, 135 x 81mm Aperture
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2
Applications
Protection Relays
Safety Equipment
Fault Monitoring
Specification
Fastron Electronics Part Number
FPT-135 800/1A 5P20 15VA
Technology
Protection Class Current Transformer
Ratio
800/5
Aperture Size
81 x 135mm
VA Rating
10VA
Accuracy Class
Class 5P20
Output
1 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10DegC / 50DegC
Continuous Current (max)
800Amp x 1.3
Termination Style
Screw
Stanbards
VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2
Unit Weight
7kg
Factory Pack Qty
1
??
Datasheet
Product Installation Guide and Datasheet
??
Fastron Electronics SCT-F16-20-1A, 20/1Amp Measurement, Class 1 Split Core Current Transformer
Features
Quick Release Split Core System
Cable Mount
1 Amp Output
Self Powered
Rated System Voltage 0.60/3kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F16-20-1A
Technology
Split Core AC Current Transformer
Ratio
20/1A
Aperture Size
ø 15 mm
VA Rating
1VA
Accuracy Class
Class 1
Output
1 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
20Amp x 1.2
Termination Style
0.5M Flying leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
GMTA-DV7D-AA, DC Voltage Transmitter with Dual Output and separate scale, 0-600VDC Input, 20-60VAC/DC Aux, 2 x 4-20mA Outputs
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals, Currents up to 10 Amp, and Voltages up to 600VAC or DC, can be converted to insulated 4 to 20 mA DC output (for direct current output type) or 0-10V/0-5V (For Direct Voltage Type)
Each unit needs just 50mm x 120mm depth DIN Rail cabinet space
Specification
Part Number
GMTA-DV7D-AA
Control Output
2 x 4-20mA Analogue Outputs
Input
0-600VDC
Alarm Type
2 x SPDT CO Relay 3 Amp (2 Independent Alarms)
Over Range
x 1.2
Operating Temperature
0 - 60°C
Load Voltage
20-60VAC/DC
Span Adjustment Range
+/-100%
Zero Adjustment Range
+/-100%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
250g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron FC5-S-1U-2-G-4 PID Controller, 24VDC with 2 x Relay Alarms, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 48x48mm,0-10V Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
FC5-S-1U-2-G-4
Control Output
0-10V
Input
Multirange K,E,J,N,T,S,R,B Thermocouple, PT100/Cu20 RTD Input/Linear Current 4(0)-20mA/Linear Voltage 0-10(5)V
Option 1
2 x Relay Alarms standard (Excludes 48x48mm with SSR/Relay output)
Mounting Style
48 x 48mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet
Datasheet
User Manual
Modbus Protocol
FC5 Communication Protocol
Fastron FC5-L-1A-2-G-4 PID Controller, 24VDC with 2 x Relay Alarms, E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 96x96mm,4-20mA Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Fastron Part Number
FC5-L-1A-2-G-4
Control Output
4-20mA
Input
Multirange Type,K,E,J, Pt100, Cu50/(Optional)Linear Current 4(0)-20mA/(Optional)Linear Voltage 0-10(5)V
Option 1
2 x Relay Alarms standard (Excludes 96x96mm with SSR/Relay output)
Mounting Style
96x96mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet & User Manual
Datasheet
User Manual
FC5 Communication Protocol
Fastron FC5-L-1U-1-G-4-C PID Controller, 24VDC with 1 Alarm, RS485, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 96x96mm,0-10V Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
FC5-L-1U-1-G-4-C
Control Output
0-10V
Input
Multirange Type K, J, E,S,T,R, Pt100, Cu50/Linear Current 4(0)-20mA/Linear Voltage 0-10(5)V
Option 1
1 Alarm, RS485 standard (Excludes 96x96mm with SSR/Relay output)
Mounting Style
96x96mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet & User Manual
Datasheet
User Manual
FC5 Communication Protocol