Fastron Electronics FESCT-055-300-5-IP65, 300Amp Measurement, 5 Amp Output Split Core CT's, Class 1, w/10M Flying leads, ø 55mm Aperture
Features
Quick Release Split Core System
10m Flying Leads
ø 55mm
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.60/3kV
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurement, 5 Amp Outputs
Specification
Fastron Electronics Part Number
FESCT-055-300-5-IP65
Technology
Split Core AC Current Transformer
Ratio
300/5A
Aperture Size
ø 55mm
VA Rating
2.5VA
Accuracy Class
Class 1
Output
5 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Dimensions
180x138x52mm
Mounting Style
Panel Mount
Operating Temperature Range
-35°C / 55°C
Continuous Current (max)
300Amp x 1.2
Termination Style
10M Twisted Pair 0.34mm^2
Unit Weight
2000g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
FP050080P, 500/5 Amp Split Core CT, Class 0.5 2.5VA Series Clip On Current Transformer
Features
Quick Release Split Core System
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
FP050080P
Technology
Split Core AC Clip On Current Transformer
Ratio
500/5
Aperture Size
50 x 80mm
VA Rating
2.5VA
Accuracy Class
Class 0.5
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10°C / 50°C
Continuous Current (max)
500Amp x 1.2
Termination Style
Screw
Approvals
CE
Unit Weight
1150g
Factory Pack Qty
1
Datasheet
Product Datasheet
Installation Guide
TRI-22-G240, 22mm LED Indicator GREEN 240VAC, Plastic, IP65, IEC60947-5-1
LED indicator Series will activate while the contacts are connected to the rated voltage. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation and visual Indication by the user.
Features :
240VAC or 24VAC/DC (400VAC Special Orders)
LED Illumination
Ø 22.5mm Cutout
Long Life
Replacement Beads Available
Standards :
IP65
IEC60947-5-1
CE
Specification
TRENT Part Number
TRI-22-G240
Functions
LED Indicator Only
Nominal Voltage
230VAC @ 50/60Hz
Impulse Voltage Wear Resistance
6kV
Illumination Type
Green LED
Short Circuit Protection (Fuse)
Recommend 10A gG Fuse
Mechanical Compression Force at Closing
20N
Mechanical Compression Force at Closing
8N
Humidity
35-85%
Approvals
CE
Standards
IP65, IEC60947-5-1
Weight
Enclosure Material
UL94V0
Factory Pack Qty
1
TRENT(Fastron) Head Office
Australia
Datasheet
Product Datasheet
Crydom ED24E5, EMR plug in Solid State Relay, 18-36VAC control, 5 Amp 24-280VAC output
Features
Ratings 5 Amp @ 24-280VAC
Plug in EMR relay style
Motor controller rated
SCR output for reliable AC switching
Multiple modules can be wired in parallel for higher currents
UL/CSA/VDE Approved, CE Compliant to EN60950-1
EMC compliant to Level 3
Epoxy free design
Spec
Crydom Part Number
ED24E5
Switching Type
DC Load
ROHS
Yes (Details)
Control Voltage
18-36VAC
Load Current
5 Amp DC
Surge Capability (10ms)
60 Amp DC
Special Feature
Plug in EMR style
Mounting Style
EMR Base
Load Voltage Range
24-280VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
38g
Factory Pack Qty
10
Datasheet
Product Datasheet
Socket
DRSED
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Rishabh CT 250/5 Class 0.5 5VA 50/21 (30) Series Current Transformer
Features
DIN Rail Mounting Clip Included
Built In Sealable Terminal Covers
Mounting Feet Supplied
Narrow Width (45mm)
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
CT 250/5 Class 0.5 5VA 50/21 (30)
Technology
AC Current Transformer
Ratio
250/5
Aperture Size
⌀ 21mm or 20x10mm Busbar
VA Rating
5VA
Accuracy Class
Class 0.5
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
250Amp x 1.2
Termination Style
Screw
Unit Weight
300g
Factory Pack Qty
9
Datasheet
Product Datasheet
Crydom ED06E5, EMR plug in Solid State Relay, 18-36VAC control, 5 Amp 1-48V DC output
Features
Ratings 5 Amp @ 60/80VDC
Plug in EMR relay style
Motor controller rated
Mosfet output for reliable DC switching
Multiple modules can be wired in parallel for higher currents
UL/CSA/VDE Approved, CE Compliant to EN60950-1
EMC compliant to Level 3
Epoxy free design
Spec
Crydom Part Number
ED06E5
Switching Type
DC Load
ROHS
Yes (Details)
Control Voltage
18-36VAC
Load Current
5 Amp DC
Surge Capability (10ms)
60 Amp DC
Special Feature
Plug in EMR style
Mounting Style
EMR Base
Load Voltage Range
1 - 48VDC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
11g
Factory Pack Qty
20
Datasheet
Product Datasheet
Socket
DRSED
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Xmer CT Split 93/30SC 100/5 Class 1 1.5VA, 23 x 33mm Aperture
Features
Quick Release Split Core System
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
Xmer CT Split 93/30SC 100/5 Class 1 1.5VA
Technology
Split Core AC Current Transformer
Ratio
100/5
Aperture Size
23 x 33mm
VA Rating
1.5VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
100Amp x 1.2
Termination Style
Screw
Unit Weight
600g
Factory Pack Qty
9
Datasheet
Product Datasheet
Fastron Electronics AM5H-A-A-V6-D-NAN, 96x48mm Digital Voltmeter 0-300VAC with 4-20mA output, 22-60VAC/DC supply, Digital Panel Meter & Transmitter, 5 Digit
Adjustable Zero and Span Setting
Adjustable Display Scaling
Large 5 Digit 20.3mm (8 Inch) LED Display
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 96 x 48mm Panel Space
90mm Depth
Specification
Fastron Electronics Part Number
AM5H-A-A-V6-D-NAN
Conditioner Output
4-20mA (Average RMS)
Input
0 - 300VAC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
22-60VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Display Type
5 Digit RED LED
Mounting Style
96 x 48mm Panel Mount
Case Material
PC - UL 94 V0
Weight
320g
Factory Pack Qty
1
Datasheet
Product Datasheet
User Manual
Application Notes
Panel Meters Blog Articles
Xmer CT Split 105/50SC 250/5 Class 1 3.75VA, 43 x 55mm Aperture
Features
Quick Release Split Core System
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
Xmer CT Split 105/50SC 250/5 Class 1 3.75VA
Technology
Split Core AC Current Transformer
Ratio
250/5
Aperture Size
43 x 55mm
VA Rating
3.755VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
250Amp x 1.2
Termination Style
Screw
Unit Weight
800g
Factory Pack Qty
9
Datasheet
Product Datasheet
TRI-22-Y24, 22mm LED Indicator AMBER 24VAC/DC, Plastic, IP65, IEC60947-5-1
LED indicator Series will activate while the contacts are connected to the rated voltage. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation and visual Indication by the user.
Features :
24VAC/DC or 24VAC/DC (400VAC Special Orders)
LED Illumination
Ø 22.5mm Cutout
Long Life
Replacement Beads Available
Standards :
IP65
IEC60947-5-1
CE
Specification
TRENT Part Number
TRI-22-Y24
Functions
LED Indicator Only
Nominal Voltage
230VAC @ 50/60Hz
Impulse Voltage Wear Resistance
6kV
Illumination Type
Amber LED
Short Circuit Protection (Fuse)
Recommend 10A gG Fuse
Mechanical Compression Force at Closing
20N
Mechanical Compression Force at Closing
8N
Humidity
35-85%
Approvals
CE
Standards
IP65, IEC60947-5-1
Weight
Enclosure Material
UL94V0
Factory Pack Qty
1
TRENT(Fastron) Head Office
Australia
Datasheet
Product Datasheet
Rishabh 3PH105-21(40) 125, Class 1, 1.5VA 125 Amp, 5 Amp Output, 3 Phase Current Transformer, Panel Mount, Busbar Mount
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
3PH105-21(40) 125
Technology
AC Current Transformer
Ratio
125/5
Aperture Size
20 x 24mm
VA Rating
1.5VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
125Amp x 1.2
Termination Style
Screw
Unit Weight
1000g
Factory Pack Qty
9
Datasheet
Product Datasheet