TCD-H-3-PT HEATING Temp Controller, 48x96mm 230VAC, C/O Relay output, PT100 RTD Input. Encoder Control,amp; Digital Display, 0-999 Deg C
Pushbutton Encoder Setpoint
3-digit display (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated ON/OFF Relay, output, Optional cooling or time proprtional versions output available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
TCD-H-3-PT
Control Output
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Input
Pt100 RTD
Control Mode
Time Proportional Control
Control Range
0- 999 Deg C
Mounting Style
48x96mm Panel Mount
Supply Voltage
230VAC
Termination Style
Screw
Sampling Time
50ms
Weight
270g
Factory Pack Qty
1
Â
Datasheet
TCD/TCR/FC5 Datasheet
TCD/TCR User Manual
TCD-H-1-PT HEATING Temp Controller, 48x96mm 230VAC, C/O Relay output, PT100 RTD Input. Encoder Control,amp; Digital Display, 0-999 Deg C
Pushbutton Encoder Setpoint
3-digit display (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated ON/OFF Relay, output, Optional cooling or time proprtional versions output available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
TCD-H-1-PT
Control Output
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Input
Pt100 RTD
Control Mode
Heating ON/OFF Control
Control Range
0- 999 Deg C
Mounting Style
48x96mm Panel Mount
Supply Voltage
230VAC
Termination Style
Screw
Sampling Time
50ms
Weight
270g
Factory Pack Qty
1
Â
Datasheet
TCD/TCR/FC5 Datasheet
TCD/TCR User Manual
Fastron FRI8-01/2, Current Monitoring Relay AC 0.2 - 2A, Adjustable delay 0.5 - 10 s, 1 x CO 10 Amp, Universal 24-240VAC 24VDC Aux Supply
FRI 8 Series serves to monitor AC currents up to 16 Amp, and provides Relay alarm output with adjustable delay time 0.5 - 10s.
Features :
Suitable for Current Transformer Monitoring
Flexible adjustment by potentiometer, choise of
6 Models: 0.05 - 0.5 A; 0.1 - 1 A; 0.2 - 2 A; 0.5 - 5 A; 0.8 - 8 A; 1.6 - 16 A Adjustable delay 0.5 - 10 s to eliminate short current peaks
Possible to use current scanning from current transformer - up to 600 A Universal supply AC 24 - 240 V and DC 24 V
Supply is galvanically separated from measured current
Output contact: 1 x changeover 8 A
1-phase, 1-MODULE, DIN rail mounting
Applications :
Heating bars in sliding rails
Heating cables
Indication of current flow
Controlling of 1-phase motor consumption
Specification
Fastron Part Number
FRI 8-01/2
Voltage Range
AC 24 - 240 V, DC 24 V (AC 50 - 60 Hz)
Operating Range
-15 %; ? %
Current Range
0.1 - 2 A (AC 50 Hz)
Current Trip Adjustment
Potentiometer
Setting Accuracy
5 %
Burden
max. 1.5 VA
Repeatability
1 %
Temperature Drift
0.1%/??C
Peak Overload (10s)
1.1 x Ipn
Time delay T1
max. 500 ms
Time delay T2
adjustable 0.1-10 s
Output
??
Number of contacts
1x changeover/ SPDT (AgNi / Silver Alloy)
Rating
10 A / AC1
Breaking capacity
2500 VA / AC1, 240 W / DC
Inrush current
10 A
Switching voltage
250 V AC1 / 24 V DC
Min. breaking capacity DC
500 mW
Indication of state
red LED
Mechanical life
1 x 107
Electrical life (AC1)
1 x 105
Other information
??
Operating temperature
-20 ... ? ??C
Storage temperature
-30 ... ? ??C
Electrical strength
4 kV (supply - output)
Operating position
any
Mounting
DIN rail EN 60715
Protection degree
IP 40 from front panel / IP 10 terminals
Overvoltage cathegory
III.
Pollution degree
2
Max. cable size (mm )2
solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5
Dimensions
90 x 17,6 x 64 mm
Weight
69 g
Standards
EN 60255-6, EN 61010-1, RoHS, CE
Datasheet
Product Datasheet
Application Notes
Monitoring relay FRI serves to monitor current level in single phase AC circuits. Due to its fluent adjustment of release current, it is predestined for applications with necessity of current flow indication, and can be used as precedence relay. Output relay is off in normal state. In case the set current level is exceeded, it switches. Multivoltage supply is an advantage.
Fastron FPC1-25-20C-24VAC/DC, Two Pole 2 x SPST NO Modular Contactor 230VAC 25 Amp, 24VAC/DC 50/60Hz Coil Voltage, Hum Free
Features
25 Amp (rms) @ 230VAC
DIN Rail Mount
Slim package
CE Compliant to IEC 60664
IP20
Specification
Fastron Part Number
FPC1-25-20C-24VAC/DC
Switching Type
2 x SPST NO
Approvals
CE
Coil Voltage
230VAC 50/60Hz
Load Rating
25 Amp
Special Feature
Hum Free
Mounting Style
DIN Rail Mount
Load Voltage Range
24VAC/DCÂ 50/60Hz
Isolation
4kV
Termination Style
Screw
Unit Weight
295g
Factory Pack Qty
20
Â
Datasheet
Datasheet
Auxiliary Contacts Selection Guide
RCS-4800-XXXX Three-Phase Flexible Current Sensor System (Rogowski Coils):
Contact Us for Possible Replacement for specific Ratings
The RCS-4800 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 0.333 volt.
A 9 to 36 VDC power supply is required to operate these coils. The RCS-4800 comes with an integrator which includes flexible strain relief cables.
Included is an 12 inch circumference rope CT with Integrator, and 8 feet of twisted pair (600V) output leads.
Magnelab Coils come with 10 year warranty
Specification
Magnelab Part Number
RCS-4800-XXXX
Function
AC Current Measurement
Nominal Measurement Current (Ipn)
500-5000 Amp RMS (please specify with order)
Measurement Range
10% - 130% if Ipn
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
9 - 36VDC
Accuracy
1% from 25 to 5000 Amp
Phase Angle
< 0.5 Degrees
Coil Diameter (⌀)
12 Inch
Coil Circumference
36 Inch
Integrator to Coil Cable
8 Feet Shielded
Maximum Voltage
600V (on bare conductor)
Operating Temperature
-15°C to 65°C
Storage Temperature
-45°C to 80°C
Power Consumption
< 2VA
Overload
20,000 Amp (continuous)
Termination Style
Screw
Weight
1200g
Certification
CE
Factory Pack Qty
1
Certifications
UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1
Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010
CE
ROHS
Datasheet
Product Datasheet
Application Notes
RCS/RCT Series Installation Guide
AFP0RE16RS, Expansion for FP0R Series Progammable Logic Controller (PLC) 8 x On/Off inputs, 8 x Relay Outputs, 24VDC
Allow the expansion of outrouts for AFP0 Series , Expansion for Progammable Logic Controller (PLC) 8 x On/Off inputs, 8 x Relay Outputs, 24VDC.Â
Datasheet
Datasheet
Crydom M505015F, Bridge, single phase, half controlled, 480VAC input, 50 Amp, with freewheeling diode
Features
Package with DCB ceramic base plate
Isolation voltage 2500 V∼
Planar glass passivated chips
Low forward voltage drop
UL registered, E 148688
Applications
Heat and temperature control for industrial furnaces and chemical processes
Lighting control
Motor control
Power converter
Advantages
Easy to mount with two screws
Space and weight savings
Improved temperature and power cycling capability
High power density
Spec
Crydom Part Number
M505015F
AC Line voltage
480V
Device Configuration
Single Phase Half Controlled Rectifier Bridge
DC Output @ 100 Deg C
100 Amp
Package Size
W:57.5mm L:44mm D:34.6mm
Itsm
600 A
VF(to)
1.7V
Tj(max)
125°C
rF
N/A
Terminals
M5 (1.5Nm)
Hole Centres
41.2mm (M5)
Gate Terminals
N/A
R th(j-c)
0.7°C/W
R th(c-h)
N/A
Weight
106g
Isolation
2.5kV
Factory Pack Qty
10
Certification
UL Listed
Crydom Headquarters
USA
Â
Datasheet
Product Datasheet
Alternatives
M5010012F
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Fastron Electronics SCT-F50-400, 0.333V, 400Amp measurement Split Core CT's
Features
Quick Release Split Core System
Cable Mount
0.333V Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Â
Specification
Fastron Part Number
SCT-F50-400
Technology
Split Core AC Current Transformer
Ratio
400/0.333V
Aperture Size
ø 50 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333V (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
400Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
400g
Factory Pack Qty
9
Â
Datasheet
Product Datasheet
Stocked Split Core CT's Listing
Application Notes
Installation Guide
Types of Current Transformers - Blog
Cable Losses and CT's
High Accuracy or High Burden Requirements for CT's
Fastron Electronics SCT-F24-200, 200 Amp, 0.333v Class 1 Series Current Transformer
Features
Quick Release Split Core System
Cable Mount
0.333v Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Â
Specification
Fastron Part Number
SCT-F24-200
Technology
Split Core AC Current Transformer
Ratio
200/0.333v
Aperture Size
ø 24 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333v (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
200Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
100g
Factory Pack Qty
9
Â
Datasheet
Product Datasheet
Application Notes
Installation Guide
BR6-FNCP4, Temp Controller, 48x24mm, 100-240VAC, TH-540N or NTC Input, 4-20mA Output
Â
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
CE Approved
Each unit needs just 60 mm depth panel space
EC Compliant
Specification
Hanyoung Nux Part Number
BR6-FNCP4
Control Output 1 (Heat)
4-20mA
Control Output 2 (Cool)
N/A
Input
TH-540N or NTC Input
Alarm
N/A
Option 1
N/A
Mounting Style
48 x 24mm Panel Mount
Supply Voltage
85Â - 265VAC
Termination Style
Screw
Weight
200g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Â
Datasheet
BR6 Series Instruction Manual
Free Software
Hanyoung Nux TCS Software
Hanyoung Nux TCS Software User Manual
VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
Eastron Europe Electronics ESCT-TA24-250A/100mA + HY-2.0, 250A/100mA Measurement, Class 1 Split Core CT's
Features
Quick Release Split Core System
Cable Mount
100mAmp Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads with HY-2.0 Connector
Applications
Eastron Modular Metering Equipment
Energy Monitoring
Load Balancing
Power Quality Measurements
Specification
Eastron Europe Part Number
ESCT-TA24-250A/100mA + HY-2.0
Technology
Split Core AC Current Transformer
Ratio
250/100mA
Aperture Size
ø 24 mm
VA Rating
1VA
Accuracy Class
Class 1
Output
100mA (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
250Amp x 1.2
Termination Style
0.9M Flying leads with HY-2.0 Connector
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
CRJ-31 Connector User Guide