RCS-1800-1000 Three-Phase Flexible Current Sensor System (Rogowski Coils):
The RCS-1800 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 0.333 volt.
A 9 to 36 VDC power supply is required to operate these coils. The RCS-1800 comes with an integrator which includes flexible strain relief cables.
Included is an 12 inch circumference rope CT with Integrator, and 8 feet of twisted pair (600V) output leads.
Magnelab Coils come with 10 year warranty
Suitable Alternative to Solar Edge CTRC-07500-1000
Specification
Magnelab Part Number
RCS-1800-1000
Function
AC Current Measurement
Nominal Measurement Current (Ipn)
1000 Amp RMS
Measurement Range
10% - 130% if Ipn
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
9 - 36VDC
Accuracy
1% from 25 to 1000 Amp
Phase Angle
< 0.5 Degrees
Coil Diameter (⌀)
6 Inch
Coil Circumference
18 Inch
Integrator to Coil Cable
8 Feet Shielded
Maximum Voltage
600V (on bare conductor)
Operating Temperature
-15°C to 65°C
Storage Temperature
-45°C to 80°C
Power Consumption
< 2VA
Overload
20,000 Amp (continuous)
Termination Style
Screw
Weight
1200g
Certification
CE
Factory Pack Qty
1
Certifications
UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1
Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010
CE
ROHS
Datasheet
Product Datasheet
Application Notes
RCS/RCT Series Installation Guide
RCS-3605-VAR, 5 Amp Output, Class 1 Three Phase 500/1000/2500/5000\10000\25000\50000 Amp AC Measurement 12 Inch Diameter Rogowski Coils with Integrator Flexible Current Sensor System (Rogowski Coils):
The RCS-3605 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 5 Amp.
A 24VDC Power Supply is included to operate these coils. The RCS-3605 comes with 5 Amp integrator..
Included is an 36 inch circumference rope CT with Integrator, and power supply.
Magnelab Coils come with 10 year warranty
Specification
Magnelab Part Number
RCS-3605-VAR
Function
AC Current Measurement
Nominal Measurement Current (Ipn)
500/1000/2500/5000\10000\25000\50000 Amp RMS Selectable
Measurement Range
10% - 130% if Ipn
Output Range
0-5 Amp
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
24VDC
Accuracy
1% from 25 to 5000 Amp
Phase Angle
< 0.5 Degrees
Coil Diameter (⌀)
12 Inch
Coil Circumference
36 Inch
Integrator to Coil Cable
8 Feet Shielded
Maximum Voltage
600V (on bare conductor)
Operating Temperature
-15°C to 65°C
Storage Temperature
-45°C to 80°C
Power Consumption
< 2VA
Overload
20,000 Amp (continuous)
Termination Style
Screw
Weight
3500g
Certification
CE
Factory Pack Qty
1
Certifications
UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1
Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010
CE
ROHS
Datasheet
Product Datasheet
Application Notes
RCS-VAR Series Installation Guide
Gigavac Contactor HX21CAB, Contactor SPST-NO 350 AMP, 1500VDC, 24VDC Coil, 38cm Flying leads, with SPST-NO Auxiliary Contact Continuous Duty, IP67, IP69
Features
Hermetically Sealed (Patented)
UL1604 for Class I & II Div 2 and Class III for use in hazardous locations
IP67 IP69
SAE J1171 External ignition protection
ISO8846 Protection against ignition around flammable gasses
CE Approved
High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power
Ideal for battery powered systems or where low power is needed
PWM option provides additional drive control flexibility
Built in Coils suppression for all DC Coils
Flexible package for installation
Integrated safety cover
Specification
Gigavac Part Number
HX21CAB
Main Contact Type
SPST-NO
Auxiliary Contact Type
SPST-NO
Coil Voltage
24VDC
Load Current
350+ Amp
Mechanical Life @ 0 Amp
1,000,000 Operations
Dielectric at Sea Level (leakage <1mA)
4.3kV rms
Control Input Terminals
38cm Flying Leads
Aux Contact Terminals
38cm Flying Leads
Special Feature
N/A
Mounting Style
Panel Mount (M5)
Load Voltage Range
1500VDC
Standards
UL1604, IP67, IP69
Termination Style
M8
Unit Weight
440g
Factory Pack Qty
1
Datasheet
Product Datasheet
FPT-100 1500/5A 5P20 5VA, Protection Class CT, 1500/5A, Class 5P20 15VA, 103 x 64mm Aperture
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2
Applications
Protection Relays
Safety Equipment
Fault Monitoring
Specification
Fastron Electronics Part Number
FPT-100 1500/5A 5P20 5VA
Technology
Protection Class Current Transformer
Ratio
1500/5
Aperture Size
103 x 64mm
VA Rating
15VA
Accuracy Class
Class 5P20
Output
5 Amp AC
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10 Deg C / 50 Deg C
Continuous Current (max)
1500Amp x 1.3
Termination Style
Screw
Stanbards
VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2
Unit Weight
1.5 kg
Factory Pack Qty
1
Datasheet
Product Installation Guide and Datasheet
Fastron H31/110M-B + D53TP50D, Three Phase Solid State Relay with Heatsink 3.5-32VDC Control, 3 x 34Amp, 48-530VAC Load
Features
Ratings from 25 to 120 Amp @ 70-480 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
IP20 Cover Included
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Fastron Part Number
H31/110M-B + D53TP50D
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
3.5-32VDC
Load Current
3 x 34 Amp (rms)
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
Panel Mount
Dimensions
L:110 x W:125 x D:180mm
Load Voltage Range
70-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
2kg
Factory Pack Qty
10
Datasheet
Product Datasheet
H31 Datasheet
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Westcode-IXYS-Littlefuse W3270NC160, Diode PUK, 2670 Amp @ 85 Deg C, 2200V, 74/26
Features
Very low forward voltage drop
Very low leakage current
International standard package
74/26 Package
Press Mounted
Double or Single Sided Cooling
Applications
Replaces ABB # 5SDA 24F2303
Power Supplies
Rectifier for drives applications
Controlled Rectifiers
AC Switch
Battery Chargers
Phase Controllers
Water Cooled AC switches
Power Factor Correction
Specification
Westcode Part Number
W3270NC160,
Vrrm
1600V
SCR Configuration
Diode Capsule PUK
IF(av) @ 100 Deg C
2670 Amp
Package Size
ø74 x 26mm
Itsm
27.6 kA
VF(to)
0.818V
Tj(max)
175°C
rF
0.108mΩ
Gate Terminals
N/A
R th(j-k) (double sided cooled 180°sin)
0.022°C/W
R th(c-h) (double sided cooled)
Weight
510g
Clamping Force
19 - 26kN
Factory Pack Qty
2
Certification
ROHS
Westcode-IXYS-Littlefuse Headquarters
USA
Datasheet
Product Datasheet
Alternatives
Contact Us for Possible Replacement
Heatsink
Heatsink Profiles
Secure Meters DPM96P360-2, 96mm x 96mm LCD Digital Power Factor Meter, 3 Phase 0-500VAC, 0-6 Amp Inputs, 0.5% Accuracy, 40 to 300VAC/DC Supply, IP54 (Optional IP65)
Features
LCD Dual Display
250mS Response Time
PC 94 UL V0
Each unit needs just 96 x 96mm Panel Space
52mm Depth
CE Approved
ROHS and REACH
Specification
Secure Part Number
DPM96P360-2
Frequency Range
45-65 Hz
Accuracy
0.5%
Input
5/6 Amp 3 Phase CT inputs, 100-500VAC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Supply Voltage
40-300VAC/DC
Termination Style
Screw
Mounting Style
96 x 96mm Panel Mount
Case Material
PC - UL 94 V0
Standards
IEC / EN 61010-1; IEC / EN 61010-2-030, IEC / EN 62053-21
Protection Degree
IP54 (IP65 Optional)
Weight
450g
Factory Pack Qty
1
Datasheet
Product Datasheet
Manual
DPM Series User Manual
Application Notes
Panel Meters Blog Articles
RTR Energia REG12DPR1400000 PR-14D.12 8/10/12 Step Automatic Reactive Power Controller, 3 Phase
Isolated Switching of Power Factor Correction Contactors
Cos ϕ Setting 0.80 to 0.95 CAP
Single CT Sensing
1A/5A Programmable Primary and secondary CT Ratio
Backlit LCD Display
Various Program Combinations
IP40
Up to 12 steps
Measurement System - Automatic/Manual
230VAC Aux Supply
Overvoltage and Under/Overcompensation management
Overtemperature alarm
Specification
RTR Energia Part Number
PR-14D.12
Function
Reactive Power Correction
Nominal Voltage (Un)
90-550V L to L, 11-300V L-N
Supply Voltage
90-550V L to L, 15VA (max) 45-65Hz
Relay Rating
250VAC/6Amp NO
Switch Delay Time
1s - 999s User Adjustable
Fan Alarm
1 x 250VAC/6Amp NO
Temperature Alarm
1 x 250VAC/6Amp NO
Re-connection Delay Time
1s - 999s User Adjustable
Desired Power Factor
0.85 IND - 0.95 CAP
Number of Output Relays
14 (12 steps, fan and temperature alarm)
Smallest Capacitor Current
50mA
CT Input Range
0.05 - 5.5 Amp
LCD Display Accuracy
Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1
Phase Angle Error
+/- 1% at I > 3% of range
Comms
RS485 Target PFC (Optional)
Termination Style
Screw
Weight
700g
Certification
IEC 654-1
Factory Pack Qty
1
Material of housing
PC/ABS Unflammable, according to UL 94 V-0
Enclosure protection
IP40 for case, IP20 for terminals
Safety
According to EN 61 010-1, installation category III Pollution degree 2
Operating Temperature
0...60 °C
Datasheet
Product Datasheet/User Manual
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
FPT-135 5000/5A 5P35 5VA Protection Class CT, 5000/5A, Class 5P35 5VA, 135 x 81mm Aperture
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2
Applications
Protection Relays
Safety Equipment
Fault Monitoring
??
Specification
Fastron Electronics Part Number
FPT-135 5000/5A 5P35 5VA
Technology
Protection Class Current Transformer
Ratio
5000/5
Aperture Size
81 x 135mm
VA Rating
5VA
Accuracy Class
Class 5P35
Output
5 Amp AC (?%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10??C / 50??C
Continuous Current (max)
5000Amp x 1.3
Termination Style
Screw
Stanbards
VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2
Unit Weight
7kg
Factory Pack Qty
1
??
Datasheet
Product Installation Guide and Datasheet
??
FPT-135 1200/5A 5P35 5VA Protection Class CT, 1200/5A, Class 5P35 5VA, 135 x 81mm Aperture
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2
Applications
Protection Relays
Safety Equipment
Fault Monitoring
??
Specification
Fastron Electronics Part Number
FPT-135 1200/5A 5P35 5VA
Technology
Protection Class Current Transformer
Ratio
1200/5
Aperture Size
81 x 135mm
VA Rating
5VA
Accuracy Class
Class 5P35
Output
5 Amp AC (?%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10??C / 50??C
Continuous Current (max)
1200Amp x 1.3
Termination Style
Screw
Stanbards
VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2
Unit Weight
7kg
Factory Pack Qty
1
??
Datasheet
Product Installation Guide and Datasheet
??
FPT-135 1000/5A 5P35 5VA Protection Class CT, 1000/5A, Class 5P35 5VA, 135 x 81mm Aperture
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2
Applications
Protection Relays
Safety Equipment
Fault Monitoring
??
Specification
Fastron Electronics Part Number
FPT-135 1000/5A 5P35 5VA
Technology
Protection Class Current Transformer
Ratio
1000/5
Aperture Size
81 x 135mm
VA Rating
5VA
Accuracy Class
Class 5P35
Output
5 Amp AC (?%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10??C / 50??C
Continuous Current (max)
1000Amp x 1.3
Termination Style
Screw
Stanbards
VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2
Unit Weight
7kg
Factory Pack Qty
1
??
Datasheet
Product Installation Guide and Datasheet
??