FPT-80 1000/1A 5P20 2.5VA, Protection Class CT, 1000/5A, Class 5P20 2.5VA, 83 x 56mm Aperture
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2
Applications
Protection Relays
Safety Equipment
Fault Monitoring
Specification
Fastron Electronics Part Number
FPT-80 1000/1A 5P20 2.5VA
Technology
Protection Class Current Transformer
Ratio
1000/5
Aperture Size
83 x 56mm
VA Rating
2.5VA
Accuracy Class
Class 5P20
Output
1 Amp AC
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10 Deg C / 50 Deg C
Continuous Current (max)
1000Amp x 20
Termination Style
Screw
Stanbards
VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2
Unit Weight
1.2 kg
Factory Pack Qty
1
Datasheet
Product Installation Guide and Datasheet
Fastron FTM1-A200-V4-W0, Single Phase, Phase Angle/Burst Controller for Primary Control of Transformer (Phase Angle mode only), Voltage/Current/Power Limit Modes, For Single Phase Loads, 400VAC, 160 Amps @ 50 Deg C, Modbus RTU
Features
Phase Angle, Distributed Burst, and Time Proportional Burst Control Functions
Made in China, Low cost
Single Phase, Angle/Burst Controller
4-20mA/0-10V/0-5V input Proportional Control
Phase Angle or Burst switching
Digital Display and Controls
Modbus RTU
Applications
Electrical Ovens, Kilns, or Furnaces
HVAC Heaters
Controlled Power Applications
Electric Boilers
Brewery Heating
Industrial Light Dimming
Suitable for HVAC or Industrial Environments
Specification
Fastron Part Number
FTM1-A200-V4-W0
Rated Operating Temperature
50°C
SCR Configuration
3 Phase AC Switch
Control Voltage
4-20mA/0-10V/0-5V/POT
Load Current
160 Amps Per Phase @ 50 Deg C
Derating
2% per 1 Deg C (approx)
Control Range
0-100%
Alarms
1 x NO Relay Contacts
Special Feature
Internal Fuse, Current Limit, Power Limit
Comms
Modbus RTU
Mounting Style
Panel Mount
Switching Voltage Range
400VAC +/-10%
Supply Voltage
230VAC +/-10%
Dimensions
H:260mm W:94mm D:187mm
Soft Start
N/A
Termination Style
Screw
Unit Weight
2.5kg (4kg Packed)
Factory Pack Qty
1
Technical Docs
User Manual
Brochure
Video for How to Set Current/Voltage/Power limit
Fastron FTM1-A200-V2-W0, Single Phase, Phase Angle/Burst Controller for Primary Control of Transformer (Phase Angle mode only), Voltage/Current/Power Limit Modes, For Single Phase Loads, 230VAC, 160 Amps @ 50 Deg C, Modbus RTU
Features
Phase Angle, Distributed Burst, and Time Proportional Burst Control Functions
Made in China, Low cost
Single Phase, Angle/Burst Controller
4-20mA/0-10V/0-5V input Proportional Control
Phase Angle or Burst switching
Digital Display and Controls
Modbus RTU
Applications
Electrical Ovens, Kilns, or Furnaces
HVAC Heaters
Controlled Power Applications
Electric Boilers
Brewery Heating
Industrial Light Dimming
Suitable for HVAC or Industrial Environments
Specification
Fastron Part Number
FTM1-A200-V2-W0
Rated Operating Temperature
50°C
SCR Configuration
3 Phase AC Switch
Control Voltage
4-20mA/0-10V/0-5V/POT
Load Current
160 Amps Per Phase @ 50 Deg C
Derating
2% per 1 Deg C (approx)
Control Range
0-100%
Alarms
1 x NO Relay Contacts
Special Feature
Internal Fuse, Current Limit, Power Limit
Comms
Modbus RTU
Mounting Style
Panel Mount
Switching Voltage Range
230VAC +/-10%
Supply Voltage
230VAC +/-10%
Dimensions
H:260mm W:94mm D:187mm
Soft Start
N/A
Termination Style
Screw
Unit Weight
2.5kg (4kg Packed)
Factory Pack Qty
1
Technical Docs
User Manual
Brochure
Video for How to Set Current/Voltage/Power limit
Advanced Energy Thyro-A-1A-500-45-H-RLP3, Thyro-A-1A-Series Single Phase SCR Controller 45Amp 500VAC Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes
Features
Optional Profinet,Profibus,Ethernet,Modbus Comms
500VAC +10/-57% Voltage, Current or Power Control
Built in Fuse
Smallest footprint on the market
Single Phase Phase Angle & Burst Controller with SWITCH operation mode
SWITCH between Phase(VAR) or Burst(TAKT) control modes
Quick TAKT Mode (QTM), VT Mode (on request)
(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control
Removable Cover
Potentiometer Adjustment
USB Configuration/Bias Setting
Synchronisation Function (dASM Module Recommended)
Applications
Electrical Ovens, Kilns, or Furnaces
Primary Control of Transformer Loads in Phase or Burst Fire mode
AC Soft Starter (Combined with PLC)
Power Regulation Applications
Electric Boilers
Brewery Heating
Industrial Light Dimming
Suitable for extreme environments such as mining
Series Optional Features
For HRL
Current Control/Feedback
Programmable Relay Alarm Output
Load Monitoring
Analogue Output
For HRLP
As above with Power Control Feedback
Communication Options
Standard Thyro Bus Module
BasicBus Module
Specification
Advanced Energy Part Number
Thyro-A-1A-500-45-H-RLP3
Approvals
CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC
Control Accuracy
3% at rated voltage
Rated Operating Temperature
45°C
Temperature Derating
0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C
SCR Configuration
Single Phase AC Switch
Control Modes
Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request)
Control Input
4(0)-20mA, 0(1)-5V, 0(2)-10V, POT
Load Current
16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)
Control Range
0-100%
Options
Conformal Coating for Gas or High Humidity Environments
Mounting Style
Panel Mount
Supply Voltage Range
500VAC +10/-15% (-57% with 24VDC Aux Supply)
Soft Start
Via PLC input
Termination Style
Screw
Unit Weight
2.1 to 30kg
Factory Pack Qty
1
Technical Docs
Brochure
User Manual
Thyro A Series Quick Installation Guide
Setting Up Comms on Thyro A Series Controllers
Anybus Device Ethernet IP Setup Guide
Advanced Energy Thyro-A-1A-500-16-H3, Thyro-A-1A-Series Single Phase SCR Controller 16Amp 500VAC Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes
Features
Optional Profinet,Profibus,Ethernet,Modbus Comms
500VAC +10/-57% Voltage, Current or Power Control
Built in Fuse
Smallest footprint on the market
Single Phase Phase Angle & Burst Controller with SWITCH operation mode
SWITCH between Phase(VAR) or Burst(TAKT) control modes
Quick TAKT Mode (QTM), VT Mode (on request)
(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control
Removable Cover
Potentiometer Adjustment
USB Configuration/Bias Setting
Synchronisation Function (dASM Module Recommended)
Applications
Electrical Ovens, Kilns, or Furnaces
Primary Control of Transformer Loads in Phase or Burst Fire mode
AC Soft Starter (Combined with PLC)
Power Regulation Applications
Electric Boilers
Brewery Heating
Industrial Light Dimming
Suitable for extreme environments such as mining
Series Optional Features
For HRL
Current Control/Feedback
Programmable Relay Alarm Output
Load Monitoring
Analogue Output
For HRLP
As above with Power Control Feedback
Communication Options
Standard Thyro Bus Module
BasicBus Module
Specification
Advanced Energy Part Number
Thyro-A-1A-500-16-H3
Approvals
CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC
Control Accuracy
3% at rated voltage
Rated Operating Temperature
45°C
Temperature Derating
0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C
SCR Configuration
Single Phase AC Switch
Control Modes
Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request)
Control Input
4(0)-20mA, 0(1)-5V, 0(2)-10V, POT
Load Current
16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)
Control Range
0-100%
Options
Conformal Coating for Gas or High Humidity Environments
Mounting Style
Panel Mount
Supply Voltage Range
500VAC +10/-15% (-57% with 24VDC Aux Supply)
Soft Start
Via PLC input
Termination Style
Screw
Unit Weight
2.1 to 30kg
Factory Pack Qty
1
Technical Docs
Brochure
User Manual
Thyro A Series Quick Installation Guide
Setting Up Comms on Thyro A Series Controllers
Anybus Device Ethernet IP Setup Guide
Fastron FTM1-A80-V2-W0, Single Phase, Phase Angle/Burst Controller for Primary Control of Transformer (Phase Angle mode only), Voltage/Current/Power Limit Modes, For Single Phase Loads, 230VAC, 64 Amps @ 50 Deg C, Modbus RTU
Features
Phase Angle, Distributed Burst, and Time Proportional Burst Control Functions
Made in China, Low cost
Single Phase, Angle/Burst Controller
4-20mA/0-10V/0-5V input Proportional Control
Phase Angle or Burst switching
Digital Display and Controls
Modbus RTU
Applications
Electrical Ovens, Kilns, or Furnaces
HVAC Heaters
Controlled Power Applications
Electric Boilers
Brewery Heating
Industrial Light Dimming
Suitable for HVAC or Industrial Environments
Specification
Fastron Part Number
FTM1-A80-V2-W0
Rated Operating Temperature
50°C
SCR Configuration
3 Phase AC Switch
Control Voltage
4-20mA/0-10V/0-5V/POT
Load Current
64 Amps Per Phase @ 50 Deg C
Derating
2% per 1 Deg C (approx)
Control Range
0-100%
Alarms
1 x NO Relay Contacts
Special Feature
Internal Fuse, Current Limit, Power Limit
Comms
Modbus RTU
Mounting Style
Panel Mount
Switching Voltage Range
230VAC +/-10%
Supply Voltage
230VAC +/-10%
Dimensions
H:260mm W:94mm D:187mm
Soft Start
N/A
Termination Style
Screw
Unit Weight
2.5kg (4kg Packed)
Factory Pack Qty
1
Technical Docs
User Manual
Brochure
Video for How to Set Current/Voltage/Power limit
Crouzet 88981136 Crouzet em4 Ethernet Nano PLC Starter Kit, 16 x Inputs, 2 (PWM), 8 (Relay) Outputs, 24 V ac/dc, Ethernet Comms, Includes Software UBS key, and Ethernet Cable
Includes software and Ethernet Cable
Up to 104 I/Os - 16 DI (4 High Speed / 8 AI)
10 x DO (2 x Solid State 0.5Amp PWM, 2 Relays 6 Amp, and 6 Relays 8 Amp)
Optional Wireless Programming & Control with native 3G and Crouzet Virtual Display
Optional Modbus RTU Network (Master/Slave)
Local datalog management
Up to 1000 programing blocks with intuitive Crouzet Soft to go from simple to complex applications
HMI Screens Available
Specification
Crouzet Part Number
88981136 (em4 Ethernet)
Analogue Inputs
12 x 0 - 10VDC, (4 High Speed)
Digital Inputs
24VAC/DC @ 2.1mA (8 Standard and 4 High Speed)
Digital Outputs
Relay, 12 or 24VAC/DC, 250VAC @ 100mA minimum (2 x 6 Amp, 6 x 8 Amp)
PWM SSR Output
2
Expandable
Yes
Comms
Ethernet (RS485, Bluetooth,3G,Standard) and Wifi versions available
LCD Display
Yes
Mounting Style
DIN Rail Mount (124.6mm)
Supply Voltage Range
24VAC/DC (21.6 - 28.8VAC)
Termination Style
Screw
Weight
350g
Environmental
Reach, RoHS, Halogen free 1272/2008/CE
Certification
CE, cULus Listed
Factory Pack Qty
1
Over Voltage Category
3 in accordance with IEC/EN 60664-1
Pollution Degree
2 in accordance with IEC/EN 61131-2
Protection rating
IP40 (Front), IP20 (Rear)
Mechanical Resistance
Immunity to vibrations IEC/EN 60068-2-6, test Fc
Immunity to shock IEC/EN 60068-2-27, test Ea
Resistance to HF Interference
Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12
Conducted and radiated emissions
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Operating Temperature
-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22
Datasheet
Product Datasheet
Software
Crouzet Touch Soft V6.00.02.173
Software M3-soft-AC9-V3.1.2.0_ML
Remote Control Software CVD_PC_V2_3_01_02
Crouzet Soft EVO EM4 1.12.01.14
Advanced Energy Thyro-A-3A-400-100-H3, Three Phase SCR Controller 100 Amp 400VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control only
Features
400VAC +10/-57% Line to Line Voltage, Current or Power Control
Smallest footprint on the market
Built in Fuses
3 Phase, Phase Angle & Burst Controller with SWITCH operation mode
SWITCH between Phase(VAR) or Burst(TAKT) control modes
(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control
Removable Cover
USB Configuration/Bias Setting
Potentiometer Adjustments
Synchronisation Function for Multiple TAKT Sync
Applications
Electrical Ovens, Kilns, or Furnaces
Primary Control of Transformer Loads in Phase or Burst Fire mode
Resistive Loads up to 6:1 Hot/Cold Ratio
AC Soft Starter (VAR Mode Combined with PLC)
Power Regulation Applications
Electric Boilers
Brewery Heating
Industrial Light Dimming
Suitable for extreme environments such as mining
Series Optional Features
For HRL
Current Control/Feedback
Programmable Relay Alarm Output
Load Monitoring
Analogue Output
For HRLP
As above with Power Control Feedback
Communication Options
Standard Thyro Bus Module
BasicBus Module
Specification
Advanced Energy Part Number
Thyro-A-3A-400-100-H3
Approvals
CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC
Control Accuracy
3% at rated voltage
Rated Operating Temperature
45°C
Temperature Derating
0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C
SCR Configuration
Three Phase AC Switch
Control Modes
Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request)
Control Input
4(0)-20mA, 0(1)-5V, 0(2)-10V, POT
Load Current
16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)
Control Range
0-100%
Options
Conformal Coating for Gas or High Humidity Environments
Mounting Style
Panel Mount
Supply Voltage Range
400VAC +10/-57% (-57% with 24VDC Aux Supply)
Soft Start
Via PLC input
Termination Style
Screw
Unit Weight
2.1 to 74kg
Factory Pack Qty
1
Technical Docs
Brochure
User Manual
2 Leg Control Application Blog
Thyro A Series Quick Installation Guide
Setting Up Comms on Thyro A Series Controllers
Anybus Device Ethernet IP Setup Guide
E-GMTA-MVO(0.333V)A-RNGMTA-MAO(0.333V)A-RN, AC Current Transmitter with Alarm, 0.333V True RMS AC Input, 100-240VAC/DC Aux, 1 x Relay Alarm
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals, Currents up to 10 Amp, and Voltages up to 600VAC or DC, can be converted to insulated 4 to 20 mA DC output (for direct current output type) or 0-10V/0-5V (For Direct Voltage Type), or given alarm Setpoint.
Each unit needs just 50mm x 120mm depth DIN Rail cabinet space
Specification
Part Number
GMTA-MVO(0.333V)A-RN
Control Output
1 x SPST Alarms 3 Amp
Input
0.333V AC
Alarm Type
1 x SPST NO Relay 3 Amp
Over Range
x 1.2
Operating Temperature
0 - 60°C
Load Voltage
100-240VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Techsem MD1100-28-432F2, Single Diode Module, 1100 Amp, 2800V
Features
Diode for line frequency
Pressure Contact Technology
Electrically insulated base plate
Industrial standard package
Long-term stability
3600V Isolation
70mm Base Width
Applications
Power Converter
Line rectifying 50/60 Hz
Deep Cycle Applications
High Powered Rectifiers
DC Blocking Diodes
Flywheel Diodes
Specification
Techsem Part Number
MD1100-28-432F2
Vrrm
2800V
Diode Configuration
Single Diode Module
IF(av) @ 85 Deg C
1100 Amp
Package Size
W:70mm L:146mm D:90mm
Itsm
34 kA
VF(to)
0.7V
Tj(max)
125°C
rF
0.12mΩ
Terminals
M12 Screw
Hole Centres
80mm x 58mm(M6)
Gate Terminals
Spade (A 2.8 - 0.8 DIN 46244)
R th(j-c)
0.042°C/W
R th(c-h)
0.02°C/W
Weight
2.8kg
Mounting Torque
6 Nm (13 Nm Terminals)
Factory Pack Qty
2
Certification
UL Listed, ROHS
Techsem Headquarters
China
Datasheet
Product Datasheet
Alternatives
DZ1070N18K
Contact Us for Possible Replacement
Trent FGM6S-3P-630H 500A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type 75kA 500 Amp, 400/690VAC
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
Disconnect
75kA Short Circuit Rating @400VAC
Suitable for Main Incoming Breaker
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
AS/NZ 61009-1
Specification
Trent Part Number
FGM6S-3P-630H 500A
Functions
MCCB
Nominal Voltage
400/690VAC @ 50/60Hz
Nominal Current Range
500 Amps RMS
Trip Delay Time
< 50ms
Rated Impulse Voltage
8kV
Operating Temperature
-25 to 50 Deg C
Mechanical Operations
20,000 Ops
Insulation Voltage
800V
Short Circuit Current
75kA
Approvals
KEMA EUR, CE
Standards
IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1
Weight
6.9kg
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
LEM DVM 4000-UI, Digital Voltage Transducer, Vpn = 4000V, 24VDC Supply, 4-20mA Analogue Output, 12kV Isolation
Features
Bandwidth DC to 13kHz
4-20mA Unipolar Analogue Output
Closed loop transducer using Hall effect
Digital Transducer
Compact and versatile
Panel Mount
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Voltage overload capability
Low power consumption
Applications
Railway substation or locomotive
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Water Treatment Electronics
Specification
LEM Part Number
DVM 4000-UI
Technology
Closed Loop Hall Effect
Aperture
No Aperture
ROHS
Yes
Supply Voltage
24 VDC, Isolated
Primary Nominal Voltage (RMS + DC)
+/- 4000V
Measurement Range
+/- 6000V
Output
4 mA at 0V, to 20mA @Vpn
Isolation
12 kV
Bandwidth
DC-13 kHz
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
M5 Screw
Unit Weight
375g
Factory Pack Quantity
4
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition