Search results for "텔레@coinsp24:「휴대폰결제테더구매tron현금화"
-
FP050080P/1a G2, 500/1 Amp Split Core CT, Class 0.5, 2.5VA Clip On AC Current Transformer, 53 x 83.5mm Aperture, Dimension 127 x 156 x 36mm
FP050080P/1A, 500/1 Amp Split Core CT, Class 0.5, 2.5VA Clip On AC Current Transformer, 53 x 83.5mm Aperture, Dimension 127 x 156 x 36mm Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FP050080P/1A Technology Split Core AC Clip On Current Transformer Ratio 500/1 Aperture Size 53 x 83.5mm VA Rating 2.5VA Accuracy Class Class 0.5 Output 1 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 500Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$112.00
$132.16 inclGST -
FP063080P/1a G2, 630/1 Amp Split Core CT, Class 0.5 3VA Clip On AC Current Transformer, 53 x 83.5mm Aperture, Dimension 127 x 156 x 36mm
FP063080P/1A, 630/1 Amp Split Core CT, Class 0.5 3VA Clip On AC Current Transformer, 53 x 83.5mm Aperture, Dimension 127 x 156 x 36mm Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FP063080P/1A Technology Split Core AC Clip On Current Transformer Ratio 630/1 Aperture Size 53 x 83.5mm VA Rating 3VA Accuracy Class Class 1 Output 1 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 630Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$112.00
$132.16 inclGST -
FP020080P/1a G2, 200/1 Amp Split Core CT, Class 1, 1.5VA Clip On AC Current Transformer, 53 x 83.5mm Aperture, Dimension 127 x 156 x 36mm
FP020080P/1A, 200/1 Amp Split Core CT, Class 1, 1.5VA Clip On AC Current Transformer, 53 x 83.5mm Aperture, Dimension 127 x 156 x 36mm Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FP020080P/1A Technology Split Core AC Clip On Current Transformer Ratio 200/1 Aperture Size 53 x 83.5mm VA Rating 1.5VA Accuracy Class Class 1 Output 1 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 200Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$112.00
$132.16 inclGST -
FP010080P/40mA G2, 100/40mA Split Core CT, Class 1, Series Clip On Current Transformer
FP010080P/40mA, 100/40mA Split Core CT, Class 1, Series Clip On Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FP010080P/40mA Technology Split Core AC Clip On Current Transformer Ratio 100/40mA Aperture Size 53 x 83.5mm VA Rating 1.5VA Accuracy Class Class 1 Output 40mA Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 100Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$112.00
$132.16 inclGST -
FP080080P G2, 800/5 Amp Split Core CT, Class 0.5, 2.5VA Clip On AC Current Transformer, 53 x 83.5mm Aperture, Dimension 127 x 156 x 36mm
FP080080P G2, 800/5 Amp Split Core CT, Class 0.5, 2.5VA Clip On AC Current Transformer, 53 x 83.5mm Aperture, Dimension 127 x 156 x 36mm Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FP080080P Technology Split Core AC Clip On Current Transformer Ratio 800/5 Aperture Size 53 x 83.5mm VA Rating 2.5VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 800Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$102.00
$120.36 inclGST -
FP160125P G2, 1600/5 Amp Split Core CT, Class 0.5, 7.5VA, 83 x 123.5mm Aperture, Dimensions 157 x 198 x 36mm
FP160125P G2, 1600/5 Amp Split Core CT, Class 0.5, 7.5VA Series Clip On Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Electronics Part Number FP160125P G2 Technology Split Core AC Clip On Current Transformer Ratio 1600/5 Aperture Size 85 x 120mm VA Rating 7.5VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 1500Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$137.00
$161.66 inclGST -
FP160160P G2, 1600/5 Amp Split Core CT, Class 0.5, 15VA, 83 x 163.5mm Aperture, Dimensions 197 x 245 x 57mm
FP160160P G2, 1600/5 Amp Split Core CT, Class 0.5, 15VA, 83 x 163.5mm Aperture, Dimensions 197 x 245 x 57mm Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Electronics Part Number FP160160P G2 Technology Split Core AC Clip On Current Transformer Ratio 1600/5 Aperture Size 83 x 163.5mm VA Rating 15VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 1600Amp x 1.2 Certifications CE Termination Style Screw Unit Weight 3.5kg Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$265.00
$312.70 inclGST -
MSD403R18M M18, Rectifier Diode 400 Amp, 1800V, M18 x 1.5, Anode stud
Free Aus Post Shipping for $300 SpendMSD403R18M M18, Rectifier Diode 400 Amp, 1800V, M18 x 1.5, Anode stud Features Full blocking capability over wide temperature range Hermetic metal case with glass insulator Threaded stud Applications Power Supplies Uncontrolled Rectifiers Oil Cooled Circuits Battery Chargers Specification MS Power Part Number MSD403R18M M18 Vrrm 1800V Diode Configuration Anode Stud IF(av) @ 100 Deg C 480 Amp IF(av) @ 120 Deg C 400 Amp Itsm 9.2 kA VF(to) 0.85V Tj(max) 180°C rF 0.51mΩ Termination Style (Tail) 10.6mm Round Lug Termination Style (Stud) M18 x 1.5 Tail Length to Stud 200mm R th(j-c) 0.13°C/W R th(c-h) 0.04°C/W Weight 250g Mounting Torque 26 Nm Factory Pack Qty 8 Country Of Origin China MS Power Headquarters Germany Datasheet
Free Aus Post Shipping for $300 Spend$119.00
$140.42 inclGST -
MSD403N18M M18, Rectifier Diode 400 Amp, 1800V, M18 x 1.5, Cathode stud
Free Aus Post Shipping for $300 SpendMSD403N18M M18, Rectifier Diode 400 Amp, 1800V, M18 x 1.5, Cathode stud Features Full blocking capability over wide temperature range Hermetic metal case with glass insulator Threaded stud Applications Power Supplies Uncontrolled Rectifiers Oil Cooled Circuits Battery Chargers Specification MS Power Part Number MSD403N18M M18 Vrrm 1800V Diode Configuration Cathode Stud IF(av) @ 100 Deg C 480 Amp IF(av) @ 120 Deg C 400 Amp Itsm 9.2 kA VF(to) 0.85V Tj(max) 180°C rF 0.51mΩ Termination Style (Tail) 10.6mm Round Lug Termination Style (Stud) M18 x 1.5 Tail Length to Stud 200mm R th(j-c) 0.13°C/W R th(c-h) 0.04°C/W Weight 250g Mounting Torque 26 Nm Factory Pack Qty 8 Country Of Origin China MS Power Headquarters Germany Datasheet Product Datasheet
Free Aus Post Shipping for $300 Spend$119.00
$140.42 inclGST -
F922 Series AC Average RMS or DC Current Transducer, 9-36VDC Supply, 0-8 Amp, 4 Output types available
F922 Series AC Average RMS or DC Current Transducer, 9-36VDC Supply, 0-8 Amp, 4 Output types available Features Isolated measurement of AC or DC currents using internal Hall effect transducer. Incorporates an integrated input level display and power supply. Wide measurement range available Choice of standard outputs Wide range isolated DC input supply DIN Rail mounting Signal Conditioned AC or DC measurement output On board bar graph display User adjustable zero offset and span controls Zero insertion loss in current measurement path Earth leakage via differential Ipn for nominal Input ‘01’ Applications Process control Transportation Petrochemical Industrial Earth Leakage Energy Monitoring/Measurement Automation Delivery Delivery in 3-5 days for small qty. Otherwise 4-6 weeks Specification Oztherm Part Number F922-X-XX-XX Functions Single Phase AC or DC Current Transducer Supply Voltage 9-36VDC Nominal Measurement Range 0-8 Amp (Sensor dependant) Maximum Measurement Range 8 Amp Alarm C/O Relay 4Amp @ 30VDC, 0.5Amp @ 150VAC Response Time 250mS Accuracy @ 25 Deg C Class 1 Bandwidth DC - 1kHz linearity < 0.15% Isolation 2.5kV Comms N/A Weight 250g Enclosure Size 79 x 60 x 85mm Factory Pack Qty 1 EU Directives N/A Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material Polyamide non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP40 Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet
$535.00 - $568.00
-
F920-A-XX-XX-XX Series AC/DC Current Transducer/Conditioner and Bipolar Power Supply, 9-36VDC Powered
F920-A-XX-XX-XX - Signal Conditioner and +/-15VDC Bipolar Power Supply with Adjustable High and Low C/O Relay Alarm. +/- 4V Bipolar Input, For External LEM Hall Effect Sensor Features Isolated measurement of AC or DC currents using a Hall effect transducer with external aperture. Incorporates an integrated input level display and power supply. Wide measurement range available Choice of standard outputs Wide range isolated DC input supply DIN Rail mounting Signal Conditioned AC Average RMS or DC measurement output On board bar graph display User adjustable zero offset and span controls Zero insertion loss in current measurement path Earth leakage via differential Ipn for nominal Input ‘01’ Applications Process control Transportation Petrochemical Industrial Earth Leakage Energy Monitoring/Measurement Automation Delivery Delivery in 3-5 days for small qty, Otherwise 4-6 weeks Datasheet Datasheet
$409.00 - $439.00
-
F921-A-XX-XX-XX, Series AC/DC Signal Conditioner and Bipolar Power Supply with High and Low Alarm
F921-A-XX-XX-XX Signal Conditioner and +/-15VDC Bipolar Power Supply with Adjustable High and Low C/O Relay Alarm. +/- 4V Bipolar Input, For External LEM Hall Effect Sensor Features Isolated measurement of AC or DC currents using a Hall effect transducer with external aperture Incorporates an integrated input level display and power supply Wide measurement range available Choice of standard outputs Wide range isolated DC input supply DIN Rail mounting Signal Conditioned AC Average RMS or DC measurement output On board bar graph display User adjustable zero offset and span controls Zero insertion loss in current measurement path Earth leakage via differential Ipn for nominal Input ‘01’ Applications Process control Transportation Petrochemical Industrial Earth Leakage Energy Monitoring/Measurement Automation Delivery Delivery in 3-5 days for small qty, Otherwise 4-6 weeks Specification Oztherm Part Number F921-X-XX-DC-XX-XX Functions Single Phase AC Current Transducer Supply Voltage 9-36VDC Nominal Measurement Range 0-20000 Amp (Sensor dependant) Maximum Measurement Range 0-20000 Amp with External Sensor Alarm C/O Relay 4Amp @ 30VDC, 0.5Amp @ 150VAC Response Time 250mS Accuracy @ 25 Deg C Class 1 Bandwidth DC - 1kHz linearity < 0.15% Isolation 2.5kV Comms N/A Weight 250g Enclosure Size 79 x 60 x 85mm Factory Pack Qty 1 EU Directives N/A Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material Polyamide non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP40 Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet
$595.00
$702.10 inclGST