Search results for "정부특례보증긴급대출 Banonpi 탤ㄹH 바넌피 선불유심 급전내구제 경상남도 연체자 긴급생활안정자금 후불폰유심매입문의 24시소액급전대출"
-
THST6416D-24-500-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-500 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply
Free Aus Post Shipping for $300 SpendTHST6416D-24-500-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-500 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply Compact and versatile Split Core Bipolar DC current sensor, +/-500 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output 64 x 16mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number THST6416D-24-500-RS485 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-500 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 500g Factory Pack Qty 6 Datasheet Product Datasheet
-
THST6416D-24-600-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-600 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply
Free Aus Post Shipping for $300 SpendTHST6416D-24-600-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-600 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply Compact and versatile Split Core Bipolar DC current sensor, +/-600 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output 64 x 16mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number THST6416D-24-600-RS485 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-600 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 500g Factory Pack Qty 6 Datasheet Product Datasheet
-
CWD2425, Solid State Relay, Single Phase 4-32VDC Control, 25A, 24-280VAC Load. High surge w/LED Indicator
Free Aus Post Shipping for $300 SpendCrydom CWD2425, Solid State Relay, Single Phase 4-32VDC Control, 25A, 24-280VAC Load. High surge w/LED Indicator Ratings from 25A to 125 Amp @ 24-280VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CSA/VDE Approved, CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriers AC & DC control types Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Crydom Part Number CWD2425 Switching Type Zero Crossing ROHS Yes (Details) Control Voltage 4-32VDC Load Current 25 Amp (rms) Surge Capability (16.6ms) 600 Amp (peak) Special Feature LED Status Indicator, High Surge Mounting Style Panel Mount Load Voltage Range 24-280VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 75g Factory Pack Qty 20 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here Equivalent CWD2450P for stocked equivalent App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
BH-300-2-24, Split Core Hall Effect DC Current Transducer, +/-300 Amp DC, 4-20mA Bipolar output, 31mm aperture, 24VDC supply
BH-300-2-24, Split Core Hall Effect DC Current Transducer, +/-300 Amp DC, 4-20mA Bipolar output, 31mm aperture, 24VDC supply Compact and versatile Split Core DC current sensor, +/-300 Amp DC, 4-20mA Bipolar Output Features ⌀31mm Aperture Split Core DC Bipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number BH-300-2-24 Technology DC Hall Effect Current Transducer with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) +/-300 Amp DC Response Time < 200mS Output Bipolar 4-20mA Analogue Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$435.00
$513.30 inclGST -
FTA-300-420-24, Hall Effect DC Current Transducer, 0-300 Amp , 4-20mA Unipolar Output, 24VDC supply, 21mm Aperture
FTA-300-420-24, Hall Effect DC Current Transducer, 0-300 Amp , 4-20mA Unipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, 0-300 Amp , 4-20mA Unipolar Output Features ⌀21mm Aperture DC Unipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- 0-10mA ~0-10A AC) 10uS Response (0-0-300A ~0-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-300-420-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) 0-300 Amp Response Time < 10uS Output Unipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
FTA-045-420B-24, Hall Effect DC Current Transducer, +/-45 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture
FTA-045-420B-24, Hall Effect DC Current Transducer, +/-45 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-20 Amp , 4-20mA Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- +/-20mA ~+/-20A AC) 10uS Response (0-+/-20A ~+/-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-015-420B-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-45 Amp Response Time < 120mS Output Bipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
FTA-030-420B-24, Hall Effect DC Current Transducer, +/-30 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture
FTA-030-420B-24, Hall Effect DC Current Transducer, +/-30 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-30 Amp , 4-20mA Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- +/-20mA ~+/-20A AC) 10uS Response (0-+/-20A ~+/-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-030-420B-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-30 Amp Response Time < 120mS Output Bipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
FTA-050-010-24, Hall Effect DC Current Transducer, +/-50 Amp , +/-10VDC Output, 24VDC supply, 21mm Aperture
FTA-050-010-24, Hall Effect DC Current Transducer, +/-50 Amp , +/-10VDC Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-50 Amp , +/-10VDC Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement +/-10VDC Instantaneous output 120mS Response (for 0- +/-10mA ~+/-10A AC) 10uS Response (0-+/-50A ~+/-100A AC) Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-050-010-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-50 Amp Response Time < 10uS Output Bipolar +/-10VDC Analogue Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
FTA-015-420B-24, DC Current Transducer, +/-15 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture
FTA-015-420B-24, DC Current Transducer, +/-15 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-20 Amp , 4-20mA Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- +/-20mA ~+/-20A AC) 10uS Response (0-+/-20A ~+/-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-015-420B-24 Technology DC Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-15 Amp Response Time < 120mS Output Bipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
FTA-300-420B-24, Hall Effect DC Current Transducer, +/-300 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture
FTA-300-420B-24, Hall Effect DC Current Transducer, +/-300 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-300 Amp , 4-20mA Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- +/-10mA ~+/-10A AC) 10uS Response (0-+/-300A ~+/-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-300-420B-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-300 Amp Response Time < 10uS Output Bipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
FTA-100-420-24, Hall Effect DC Current Transducer, 0-100 Amp , 4-20mA Unipolar Output, 24VDC supply, 21mm Aperture
FTA-100-420-24, Hall Effect DC Current Transducer, 0-100 Amp , 4-20mA Unipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, 0-100 Amp , 4-20mA Unipolar Output Features ⌀21mm Aperture DC Unipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- 0-10mA ~0-10A AC) 10uS Response (0-0-100A ~0-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-100-420-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) 0-100 Amp Response Time < 10uS Output Unipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
FTA-300-010-24, Hall Effect DC Current Transducer, +/-300 Amp , +/-10VDC Output, 24VDC supply, 21mm Aperture
FTA-300-010-24, Hall Effect DC Current Transducer, +/-300 Amp , +/-10VDC Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-300 Amp , +/-10VDC Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement +/-10VDC Instantaneous output 120mS Response (for 0- +/-10mA ~+/-10A AC) 10uS Response (0-+/-300A ~+/-100A AC) Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-300-010-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-300 Amp Response Time < 10uS Output Bipolar +/-10VDC Analogue Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST