Search results for "텔레@UPCOIN24*$코인믹싱코인전송대행"
-
RQS40L024DC0T, Quad Output Relay, 4 x 5 Amp C/O, 250VAC/30VDC Load, 24VDC Coil
Free Aus Post Shipping for $300 SpendRelequick RQS40L024DC0T Series Quad 4 x 5Amp Din Rail Mount AC/DC Relay, 24VDC Coil Features 4 x 5 Amp @ 250VAC or 30VDC DIN Rail Mount Changeover Contact Ultra slim package CE Compliant to IEC 60664 IP67 Suits SQB41D00T Socket Specification Relequick Part Number RQS40L024DC0T Switching Type 4 x 30VDC/250VAC C/O No of Pins 14 Approvals UL, CE Control Voltage 24VDC Load Current 4 x 5 Amp (rms) Special Feature LED Status Indicator Mounting Style DIN Rail Mount Load Voltage Range 0-250VAC, 0-30VDC Termination Style PCB or Socket Mount Unit Weight 38g Factory Pack Qty 20 Datasheet Relay Datasheet
-
BH-10-2-24, Split Core Hall Effect DC Current Transducer, +/-10 Amp DC, 4-20mA Bipolar output, 31mm aperture, 24VDC supply
BH-10-2-24, Split Core Hall Effect DC Current Transducer, +/-10 Amp DC, 4-20mA Bipolar output, 31mm aperture, 24VDC supply Compact and versatile Split Core DC current sensor, +/-10 Amp DC, 4-20mA Bipolar Output Features ⌀31mm Aperture Split Core DC Bipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number BH-10-2-24 Technology DC Hall Effect Current Transducer with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) +/-10 Amp DC Response Time < 200mS Output Bipolar 4-20mA Analogue Isolation 2.5kV (AC, 10Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 2% Termination Style Elevator Screw Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$425.00
$501.50 inclGST -
MT550-SSHFNAASS (DIN), Multifunction Power Transducer, Class 0.1, 4 Wire, 50-500V L-N, 5A AC Input 16-400Hz, 70-300VDC or 80-276VAC Aux Input, 2 Programmable analogue outputs, 2 Pulse Outputs, USB, Ethernet, RS485 Comms
Free Aus Post Shipping for $300 SpendIskra Doo MT550-SSHFNAASS (DIN), Multifunction Power Transducer, Class 0.1, 4 Wire, 50-500V L-N, 5A AC Input 16-400Hz, 70-300VDC or 80-276VAC Aux Input, 2 Programmable analogue outputs, 2 Pulse Outputs, USB, Ethernet, RS485 Comms Class 0.1 Active, Class 0.2 Reactive (EN 60688) RS485 Comms as standard Up to 4 I/O Modules (analogue output, Multiple break point, non-linear characterstics Automatic range of nominal current up to 12.5 A (Includes 5A/1A CT Input) and nominal voltage up to 600 V L-N Adjustable tariff clock, display of electric energy consumption in optional currency RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Measurements of energy in all 4 quadrants Average values of measurands per interval Certified ship version available The Power Transducer is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : Measurement of instantaneous values of more than 140 quantities (U, I, P, Q, S, PF, PA, f, f, MD, etc.). Accuracy Class 0.5s Active, Class 0.2 Reactive (EN 60688), Class 0.1 on Comms 32 Adjustable Alarms Input frequency 50/60 Hz or 400 Hz RS 232/RS485 communication up to 115,200 bit/s (Optional) or USB communication as standard MODBUS RTU communication protocol Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs) Universal Supply 24-300VDC or 40-276VAC Automatic range of nominal current up to 12.5 A and nominal voltage up to 600 V User-friendly PC MiQen software Optional Remote Display Support Specification Iskra Doo Part Number MT550-SSHFNAASS (DIN) Functions 3 Phase Power Transducer Supply Voltage 24-300VDC or 40-276VAC Nominal Measurement Range 500V L-N, 5 Amp Maximum Measurement Range 600V L-N, 12.5 Amp Alarm N/A Tariff Input N/A Output(s) 2 x Analogue Accuracy Class 0.2 (I,U,F,PF,θ,THD) Class 0.1(Active), Class 0.2 (Reactive) Battery Backup N/A Real Time Clock 1min/month (30ppm) Terminations EU Style Clamp Terminals Isolation 3.5kV Comms USB (standard) RS232 2400-115200 b/s (RS485 Optional) Weight 900g Enclosure Material UL94, Factory Pack Qty 1 EU Directives EN61010, EN60688,EN61326-1,60529,60068-2-1/-2/-6/-27/-30 Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20 Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet Software MiQen Setting Software
-
MG73BQ 3 Phase 4 Wire or Single Phase Voltage Monitoring Relay With DPDT Contacts, Undervoltage, Selectable Overvoltage, 3 x 120-240 VAC
Free Aus Post Shipping for $300 SpendGIC Controls MG73BQ 3 Phase 4 Wire or Single Phase Voltage Monitoring Relay With DPDT Contacts, Undervoltage, Selectable Overvoltage, 3 x 120-240 VAC Relay control, on 3-phase networks : Overvoltage between phases, Undervoltage between phases Overvoltage between phases and neutral, Undervoltage between phases and neutral, Loss of neutral Multi-voltage Products Controls its own supply voltage True RMS measurement LED status indication 3-phase voltage controllers which monitor : Undervoltage, adjustable from -20 to -2 % of Un Overvoltage, adjustable from 2 to 20 % of Un Measurements are taken between neautral and Phases for MG73BQ MG73BQ and between Phases and Neutral for the H3USN Faults are signalled via LEDs, distinguishing the origin of the fault (one LED for the upper threshold, one LED for the lower threshold). Set the selector switch to the 3-phase network voltage Un. The position of this selector switch is only taken into account when the unit is powered up. If the switch position changes while the unit is operating, all the LEDs flash but the product continues to work normally with the voltage selected on energisation prior to the change of position. The LEDs return to their normal state if the switch is reset to its initial position defined before the last energisation. Specification GIC Controls Part Number MG73BQ (3 Phase 4 Wire/Single Phase Monitoring Relay With DPDT Contacts) Function Undervoltage/Overvoltage between phases Nominal Voltage 3 x 120 → 3 x 240 V ∿ Digital Outputs 2 x C/O Relays, 250VAC/DC @ 5 Amp Min Breaking Current 10mA/5VDC Timing Range 0.3 → 30s (0, +10%) Delay on Pickup 500ms Alarm Delay on Time (max) 200ms Reset Time 1500ms Fixed Hysteresis 2% of Un Maximum Measurement Cycle Time 150ms/True RMS Measurement Measurement Accuracy 1% Supply Voltage Range Same as Measurement 3 x 220 → 3 x 480 V ∿ Termination Style Screw Weight 170g Certification CE, UL, CSA, GL, ROHS Factory Pack Qty 1 Over Voltage Category 3 in accordance with IEC/EN 60664-1 Pollution Degree 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Mechanical Resistance Immunity to vibrations IEC/EN 60068-2-6, test Fc Immunity to shock IEC/EN 60068-2-27, test Ea Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22 Datasheet Product Datasheet
-
FTA-400-420-24, Hall Effect DC Current Transducer, 0-400 Amp , 4-20mA Unipolar Output, 24VDC supply, 21mm Aperture
FTA-400-420-24, Hall Effect DC Current Transducer, 0-400 Amp , 4-20mA Unipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, 0-400 Amp , 4-20mA Unipolar Output Features ⌀21mm Aperture DC Unipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- 0-10mA ~0-10A AC) 10uS Response (0-0-400A ~0-400A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-400-420-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) 0-400 Amp Response Time < 10uS Output Unipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Molex 4 Pin Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
H-300-2-24, Split Core Hall Effect DC Current Transducer, 0-300 Amp DC, 4-20mA unipolar output, 31mm aperture, 24VDC supply
Free Aus Post Shipping for $300 SpendH-300-2-24, Split Core Hall Effect DC Current Transducer, 0-300 Amp DC, 4-20mA unipolar output, 31mm aperture, 24VDC supply Compact and versatile Split Core DC current sensor, 0-300 Amp DC, 4-20mA Unipolar Output Features ⌀31mm Aperture DC Unipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number H-300-2-24 Technology DC Hall Effect Current Transducer with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-300 Amp Response Time < 200mS Output Unipolar 4-20mA Analogue Isolation 4kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
-
FTA-045-420B-24, Hall Effect DC Current Transducer, +/-45 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture
FTA-045-420B-24, Hall Effect DC Current Transducer, +/-45 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-20 Amp , 4-20mA Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- +/-20mA ~+/-20A AC) 10uS Response (0-+/-20A ~+/-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-015-420B-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-45 Amp Response Time < 120mS Output Bipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
THST6416D-24-2000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-2000 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply
Free Aus Post Shipping for $300 SpendTHST6416D-24-2000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-2000 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply Compact and versatile Split Core Bipolar DC current sensor, +/-1000 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output 64 x 16mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number THST6416D-24-2000-RS485 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-2000 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 500g Factory Pack Qty 6 Datasheet Product Datasheet
-
Xmer CT Split 125/50SC 300/5 Class 0.5 2.5VA, 55 x 85mm Aperture
Free Aus Post Shipping for $300 SpendXmer CT Split Xmer CT Split 125/50SC 300/5 Class 0.5 2.5VA, 55 x 85mm Aperture Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number Xmer CT Split 125/50SC 300/5 Class 0.5 2.5VA Technology Split Core AC Current Transformer Ratio 300/5 Aperture Size 55 x 85mm VA Rating 2.5VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 300Amp x 1.2 Termination Style Screw Unit Weight 1.25kg Factory Pack Qty 9 Datasheet Product Datasheet
-
Rish Xmer Splt Core 195/80 2500/5 Split Core CT Class 1 30VA, 85 x 172mm Aperture
Rish Xmer Splt Core Split Core 2500/5 Amp 195/80 Class 1, 30VA Series Current Transformer, 85 x 172mm Aperture Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Electronics Part Number Rish Xmer Split Core 2500/5 195/80 Technology Split Core AC Current Transformer Ratio 2500/5 Aperture Size 172 x 85mm VA Rating 30VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 40°C Continuous Current (max) Ipn x 1.2 Termination Style Screw Unit Weight 2kg Factory Pack Qty 9 Datasheet Product Datasheet
$383.00
$451.94 inclGST -
Rish Xmer 155/80 1500/5 Split Core CT Class 1 30VA, 85 x 125mm Aperture
Heavy Item - No Free ShippingRishabh Xmer CT Split 155/80 1500/5 Class 1 30VA Series Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number Rish Xmer 155/80 1500/5 SCCT Class 1 30VA Technology Split Core AC Current Transformer Ratio 1500/5 Aperture Size 85 x 125mm VA Rating 30VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 1500Amp x 1.2 Termination Style Screw Unit Weight 1000g Factory Pack Qty 9 Datasheet Product Datasheet
-
Thyro-ECO-A2A-400-125 E L3, Thyro-A-2A-ECO Series 2 Leg 3 Phase Burst(TAKT) Controller 125 Amp Rating, Voltage Control only, Most Economical Configuration, Suitable for Transformer Loads and Resistive Loads with 6:1-Hot Cold Ratio
Advanced Energy Thyro-ECO-A2A-400-125 E L3, Thyro-A-2A-ECO Series 2 Leg 3 Phase Burst(TAKT) Controller 125 Amp Rating, Voltage Control only, Most Economical Configuration, Suitable for Transformer Loads and Resistive Loads with 6:1-Hot Cold Ratio Features 230VAC +10/-57% Voltage Control Smallest footprint on the market 3 Phase, Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Fully enclosed IP20 Phase Angle(VAR), and Burst Fire(TAKT) switching Removable Cover USB Configuration/Bias Setting Synchronisation Function Digital Alarm Output Load Monitoring Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode AC Soft Starter (Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Special Features Economic Model Specification Advanced Energy Part Number Thyro-ECO-A2A-400-125 E L3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C SCR Configuration 3 Phase AC Switch Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 25 to 125 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-57% (-57% 24VDC Aux) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 10kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installtion Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$3,077.91
$3,631.93 inclGST