Rishabh Rish Xmer 86-50 (45) 1200/5 Class 1 30VA Series Current Transformer
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
Rish Xmer 86-50 (45) 1200/5 Class 1
Technology
AC Current Transformer
Ratio
1200/5
Aperture Size
⌀ 46mm or 51 x 12mm Busbar
VA Rating
30VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
1200Amp x 1.2
Termination Style
Screw
Unit Weight
0.9kg
Factory Pack Qty
9
Datasheet
Product Datasheet
Varsi-Raycap V680E40, 680VAC, 895VDC, E40 Package, 1130W Metal Oxide Varistor (MOV), Equivalent to Epcos SIOV-B40K680 Features
Features
High Energy Absorption Rating
Industry Standard Package
Wide Operating Range 35 - 1100VAC
High Peak Current Capability (70kA)
UL/CSA/ROHS/ISO9001:2015 Approved
Panel Mount
Screw Terminals
APPLICATION AREAS:
1. Railways and trams: For the protection of electrical equipment, power electronics (IGBT, thyristors...) in systems with alternating, direct or combined AC + DC power supply, especially in power supply of AC/DC, DC/AC, DC/DC converters. They may be used in systems with main and auxiliary power supply for example: automatic control and regulation systems, cooling systems, warming systems, ventilation systems, and combination systems (electromechanical, electropneumatic and other systems).
2. Wind powerplants For protection of automatic control and regulation in power electronics (IGTB, tyristors...), as well as the protection of sensitive electronic systems (e. g. AC/DC, DC/AC, DC/DC converters, drive systems) from direct or indirect lightning strikes.
3. Photovoltaic systems For protection of photopanels, automatic control electronics with sensitive electronic components, and DC/AC converters (inverters) from direct or indirect lightning strikes. Depending on the application, both serial and parallel connections are possible. With serial connection the required voltage is achieved. With parallel connection higher current absorption is achieved in the modules.
Specification
Varsi-Raycap Part Number
V680E40
Operating Voltage AC (50-60Hz)
680V
Operating Voltage DC
895V
Average Power Dissipation
1.4W
Permissable Peak Current
40kA
Energy Absorption(2ms)
1130W(max)
Tolerance(Vn)
+/- 10%
Termination Style
Screw
Weight
73g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CSA
Yes
Datasheet
Product Datasheet
Application Notes
Technical Blog MOV Article
GDT/MOV/TVS Tester
SPD Tester
Varsi-Raycap V385E40, 385VAC, 505VDC, E40 Package, 815W Metal Oxide Varistor (MOV), Equivalent to Epcos TDK SIOV-B40K385
Features
High Energy Absorption Rating
Industry Standard Package
Wide Operating Range 35 - 1100VAC
High Peak Current Capability (70kA)
UL/CSA/ROHS/ISO9001:2015 Approved
Panel Mount
Screw Terminals
APPLICATION AREAS:
1. Railways and trams: For the protection of electrical equipment, power electronics (IGBT, thyristors...) in systems with alternating, direct or combined AC + DC power supply, especially in power supply of AC/DC, DC/AC, DC/DC converters. They may be used in systems with main and auxiliary power supply for example: automatic control and regulation systems, cooling systems, warming systems, ventilation systems, and combination systems (electromechanical, electropneumatic and other systems).
2. Wind powerplants For protection of automatic control and regulation in power electronics (IGTB, tyristors...), as well as the protection of sensitive electronic systems (e. g. AC/DC, DC/AC, DC/DC converters, drive systems) from direct or indirect lightning strikes.
3. Photovoltaic systems For protection of photopanels, automatic control electronics with sensitive electronic components, and DC/AC converters (inverters) from direct or indirect lightning strikes. Depending on the application, both serial and parallel connections are possible. With serial connection the required voltage is achieved. With parallel connection higher current absorption is achieved in the modules.
Specification
Varsi-Raycap Part Number
V385E40
Operating Voltage AC (50-60Hz)
385V
Operating Voltage DC
505V
Average Power Dissipation
1.4W
Permissable Peak Current
40kA
Energy Absorption(2ms)
815W(max)
Tolerance(Vn)
+/- 10%
Termination Style
Screw
Weight
65g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CSA
Yes
Datasheet
Product Datasheet
Application Notes
Technical Blog MOV Article
GDT/MOV/TVS Tester
SPD Tester
Trent 35AF Series 690V, 35 Amp, aR Semiconductor I²t Fuse BS88 Style
Features
Equivalent to Mersen 6.9 URS 17/32 L075887, Bussmann 35ET, ETI BS17UQ/63/35A/690V
British Standard Fuse Links Package
Wide Range of I²t
Ratings up to 1000 Amp
Busbar or Standoff Mounting
IEC Standard 60269.1 AND 4
690 V Voltage Rating complying with IEC 33
Applications
Protection of High Powered Semiconductors according to I²t
Short Circuit Protection
DC or AC Motor I²t Protection
Battery Fuse
Specification
Trent Part Number
35AF
Fuse Type
I²t aR Class
Nominal Voltage
690VAC @ 50Hz
I²t Rating (IP < 30IN)
510 A²/s
I²t Rating (IP > 30IN)
725 A²/s
Nominal Current (RMS + DC)
35 Amp
Tested Breaking Capacity
200kA @ 690VAC
Dimensions
17 x 49mm
Hole Centers
60.9 - 65.6mm
Mounting Style
Busbar or Panel Mount with Standoff
Operating Temperature Range
-40°C / 125°C
Watt Loss
9.6W
Termination Style
M6
Unit Weight
61g
Factory Pack Qty
10
Datasheet
Product Datasheet
Cross Reference Chart
Crydom HS501DR + HD4850, Panel or Din Rail Mount Solid State Relay 3-32VDC Control Input, 90-530VAC Output, 10 Amps
Features
Ratings from 25A to 125 Amp @48-530 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Part Number
HS501DR + HD4850
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
3-32VDC
Load Current
10 Amp (rms) @ 40 Deg C
Surge Capability
597 Amp (peak)
Special Feature
N/A
Mounting Style
Panel Mount
Load Voltage Range
48-530VAC
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Screw Terminals
Dimensions
L:79.9mm x W:45mm x D:40.3mm
Unit Weight
296g
Factory Pack Qty
20
Datasheet
HS501DR
Series 1 HD
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crydom HS501DR + MCBC4825CF, Single Phase Proportional Burst Controller with Heatsink, 10 Cycles, 0-10VDC Input, 90-530VAC, 9 Amps
Features
Proportional Phase Control Input
Ratings from 25A to 90 Amp @ 380-530 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Part Number
HS501DR + MCBC4825CF
Switching Type
Burst Fire (Zero Crossing)
ROHS/CE/UL
Yes
Control Voltage
0-10V Proportional Input
Load Current
9 Amp (rms) @ 40 Deg C
Surge Capability
239 Amp (peak)
Special Feature
Proportional Controller + SSR
Mounting Style
DIN Rail or Panel Mount
Load Voltage Range
380-530VAC
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Screw Terminals
Dimensions
L:79.9mm x W:45mm x D:40.3mm
Unit Weight
296g
Factory Pack Qty
20
Datasheet
HS501DR
MCBC Series
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
HS501DR + RS1API420MA280025R, Single Phase Proportional Phase Controller with Heatsink, 4-20mA Input, 240V, 10 Amps
4-20mA Proportional Phase Control Input
Ratings from 25A to 80 Amp @ 180-280 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Includes Plastic IP20 Terminal Cover
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Specification
Part Number
HS501DR + RS1API420MA280025R
Switching Type
Phase Angle (Random Crossing)
ROHS/CE/UL
Yes
Control Voltage
4-20mA Proportional Input
Load Current
10 Amp (rms) @ 40 Deg C
Surge Capability
500 Amp (peak)
Special Feature
Proportional Controller + SSR
Mounting Style
Din Rail or Panel Mount
Load Voltage Range
180-280VAC
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Screw Terminals
Dimensions
L:79.9mm x W:45mm x D:40.3mm
Unit Weight
296g
Factory Pack Qty
20
Datasheet
HS501DR
RS1A Series
Product Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent Parts
Crydom HS501DR + H12D4840DE, Panel or slide on Din Rail Dual Solid State Relay, 3-32VDC Control, LED Status 1200V Transient, 24-530VAC Output, 2 x 5Amps
Features
Ratings from 25A to 40 Amp @48-530 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Part Number
HS501DR + H12D4840DE
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
4-32VDC
Load Current
2 x 5 Amp (rms) @ 40 Deg C
Surge Capability
597 Amp (peak)
Special Feature
Dual SSR
Mounting Style
Din Rail or Panel Mount
Load Voltage Range
48-530VAC
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Faston Terminals
Dimensions
L:79.9mm x W:45mm x D:40.3mm
Unit Weight
296g
Factory Pack Qty
20
Datasheet
HS501DR
H12D Series
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crydom HS211 + D2440, Panel or slide on Din Rail Solid State Relay, 3-32VDC Control Input, LED Status, 24-280VAC Output, 25 Amps
Features
Ratings from 25A to 125 Amp @24-280 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Panel Mount
Din Rail Mount
Spec
Part Number
HS211R + D2440
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
3-32VDC
Load Current
25 Amp (rms) @ 40 Deg C
Surge Capability
597 Amp (peak)
Special Feature
N/A
Mounting Style
Din Rail or Panel Mount
Load Voltage Range
24-280VAC
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Screw Terminals
Dimensions
L:81mm x W:45mm x D:73.4mm
Unit Weight
296g
Factory Pack Qty
20
Datasheet
HS211
Series 1 AC
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crydom HS211 + D2450-10, Panel or slide on Din Rail Solid State Relay 3-32VDC Control Input, LED Status, Random Cross, 24-280VAC Output, 25 Amps
Features
Ratings from 25A to 125 Amp @24-280 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Panel Mount
Din Rail Mount
Spec
Part Number
HS211 + D2450-10
Switching Type
Random Crossing
ROHS/CE/UL
Yes
Control Voltage
3-32VDC
Load Current
25 Amp (rms) @ 40 Deg C
Surge Capability
597 Amp (peak)
Special Feature
N/A
Mounting Style
Panel Mount
Load Voltage Range
24-280VAC
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Screw Terminals
Dimensions
L:81mm x W:45mm x D:73.4mm
Unit Weight
296g
Factory Pack Qty
20
Datasheet
HS211
D2450-10
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crydom HS211 + HD4850-10, Panel or slide on Din Rail Solid State Relay Random Crossing, 3-32VDC Control Input, 90-530VAC Output, 23 Amps
Features
Ratings from 25A to 125 Amp @48-530 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Panel Mount
Din Rail Mount
Spec
Part Number
HS211 + HD4850-10
Switching Type
Random Crossing
ROHS/CE/UL
Yes
Control Voltage
3-32VDC
Load Current
23 Amp (rms) @ 40 Deg C
Surge Capability
597 Amp (peak)
Special Feature
N/A
Mounting Style
Din Rail or Panel Mount
Load Voltage Range
48-530VAC
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Screw Terminals
Dimensions
L:81mm x W:45mm x D:73.4mm
Unit Weight
296g
Factory Pack Qty
20
Datasheet
HS211
HD4850-10
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crydom HS211 + HA4850E, Panel or slide on Din Rail Solid State Relay 24VAC Control Input, 90-530VAC Output, 25 Amps
Features
Ratings from 25A to 125 Amp @48-530 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Panel Mount
Din Rail Mount
Spec
Part Number
HS211 + HA4850E
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
18-36VAC
Load Current
25 Amp (rms) @ 40 Deg C
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
Din Rail or Panel Mount
Load Voltage Range
48-530VAC
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Screw Terminals
Dimensions
L:81mm x W:45mm x D:73.4mm
Unit Weight
296g
Factory Pack Qty
20
Datasheet
HS211
Series 1 HD
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies