Eastron SDM630MCT-1L-TCP 3 Phase DIN Rail Mount kWh Meter with Easyclick, 240VAC aux, Class 1, 100mA RJ12 CT Connect, w/RS485 Modbus RTU Comms
100mA RJ12 CT 4 x 3 Phase Connect
100mA RJ12 12 x Single Phase RJ12 CT with adapter
RS 485 communication up to 38,400 bit/s as standard
True RMS values of currents and voltages
Easyclick CT system reduces installation costs
Dual Metering System Reduces Cost and saves space
Â
The meter is intended for measuring, and monitoring 1 x three phase or 3 x single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals.
Â
Features :
System Accuracy Class B/Class1
Measurement of Active and Reactive Power
Modbus RTU communication up to 38,400 bit/s communication
Graphic LCD with illumination
Specification
Eastron Europe Part Number
SDM630MCT-1L
Functions
Quad Three Phase Energy Meter/ 12 x Single Phase Energy Meter
Supply Voltage
230V L-N +/-15% < 5VA
Nominal Measurement Range
415V L-L 230V L-N, 1/5 Amp +/-15%
Maximum Measurement Range
480V L-L 230V L-N, 1/5 Amp
Nominal CT Current Input
100mA via RJ12 Easyclick CT's
Pulse Output
N/A
Tariff Input
N/A
System Accuracy
Class 1 (I,U,F,kW,kWh) Class 2 (Reactive)
Mounting
Din Rail
Real Time Clock
1min/month (30ppm)
Internal Memory
N/A
Dimensions
72mm x 100mm x 66mm (4 modules wide)
Isolation
4kV
RS485
2400-38400 b/s (400ms Response Time)
Weight
700g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Safety
IP51(Indoor)
Enclosure Material
Noryl with fire protection to UL94-V-O. Self extinguishing
Enclosure Size
DIN 42880 4 Modules
Operating Temperature
-20 →+70 °C
Â
Documents
Product Datasheet
User Manual
Modbus Protocol
Suitable RJ12 CT's
Three Phase J12 Connected CT's
Split Core Single Phase CT's for RJ12 Connected Meters
Modbus Utility
EEM Meter Setting Software Utility
Shinko BCR2R1016 Series Digital Indicating Controllers
• Program control, converter function are standard features
• 5-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
• Drip-proof / Dust-proof IP66 (front panel only)
• 9-step pattern (for SV and time) is a standard feature
• UL/CSA Approved
• Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
• Each unit needs just 60 mm depth panel space
• EC Compliant (Details)
Specification
Shinko Part Number
BCR2R1000
Control Output
SSR 12VDC +/-15%, 40mA with (short circuit protected)
Input
Multirange (refer to datasheet)
Option 1
2nd Alarm Relay
Option 2
RS485 Comms
Mounting Style
48 x 96mm Panel Mount
Load Voltage Range
24VAC/DC
Termination Style
Screw
Weight
170g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Datasheet
BC Series Brochure
BC Series User Manual
BC Series RS485 Comms Manual
Shinko Product Guide
Fine Tuning Adjustments
Shinko JCL33AR/M1 Series Digital Indicating Controllers
• Program control, converter function are standard features
• 5-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
• Drip-proof / Dust-proof IP66 (front panel only)
• 9-step pattern (for SV and time) is a standard feature
• UL/CSA Approved
• Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
• Each unit needs just 24 x 48mm panel space
• EC Compliant (Details)
Specification
Shinko Part Number
JCL33AR/M1
Control Output
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Input
Multirange (refer to datasheet)
Alarm
1 x Relay Alarm (3A/1A)& 1 x Open Collector(100mA)
Option
None
Mounting Style
24 x 48mm Panel Mount
Supply Voltage
24VAC/DC
Termination Style
Screw
Weight
120g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Â
Datasheet
Download Datasheet
Download Manual
Delivery in 2-3 weeks if not in stock.
Fastron Electronics SCT-F36-400-5A, 5 Amp, 400Amp measurement Split Core CT's
Features
Quick Release Split Core System
Cable Mount
5 Amp Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Â
Specification
Fastron Part Number
SCT-F36-400-5A
Technology
Split Core AC Current Transformer
Ratio
400/5 Amp
Aperture Size
ø 35 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
5 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
400Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
400g
Factory Pack Qty
9
Â
Datasheet
Product Datasheet
Stocked Split Core CT's Listing
Application Notes
Installation Guide
Types of Current Transformers - Blog
Cable Losses and CT's
High Accuracy or High Burden Requirements for CT's
Shinko BCD2R1006 Series Digital Indicating Controllers
• Program control, converter function are standard features
• 5-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
• Drip-proof / Dust-proof IP66 (front panel only)
• 9-step pattern (for SV and time) is a standard feature
• UL/CSA Approved
• Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
• Each unit needs just 60 mm depth panel space
• EC Compliant (Details)
Specification
Shinko Part Number
BCD2R1006
Control Output
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Input
Multirange (refer to datasheet)
Option 1
None
Option 2
RS485
Mounting Style
96 x 96mm Panel Mount
Load Voltage Range
24VAC/DC
Termination Style
Screw
Weight
170g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Datasheet
BC Series Brochure
BC Series User Manual
BC Series RS485 Comms Manual
Shinko Product Guide
Fine Tuning Adjustments
Hanyoung Nux UP18RD-8NA-C, Inductive Proximity Sensor M18 Cylindrical Unshielded, 8mm Sensing Distance (0-6.4mm Set), 12-24VDC NPN Output, Normally Open NO, Connector TypeUP18RD-8NA-C, Inductive Proximity Sensor M18 Cylindrical Unshielded, 8mm Sensing Distance (0-6.4mm Set), 12-24VDC NPN Output, Normally Open NO, Connector Type
200HZ Response
12-24VDC Operating voltage
200mA Maximum Output
Built in reverse power, surge, overcurrent protection
50 Meg Ohm Insulation residtance
Specification
Hanyoung Nux Part NumberFastron NArt Number
UP18RD-8NA-C
Sensor Type
Inductive Proximity Sensor M18 Cylindrical Unshielded
No of Wires
3
Material
Stainless Steel Body / Face PBT / Cable Holder Polyester Elastomer
Shielded
NO
Sensing Distance
4mm (0-3.2mm Set)
Frequency Response
200Hz
Output Type
12-24VDC NPN Normally Open
Sensor Thread Size
M18
Standard Target
Ferrous Metal 8 x 8 x 1mm
Approvals
CE
Residual Voltage
1.5V
Current Consumption
6mA
Ambient Operating Temperature
-25 to 70 Deg C
Insulation Resistance
50 Meg Ohm (500V dc in Megohms) between all terminals and case
Dielectric Strength
1500Vac 1 min at 50/60Hz Between all terminals and case
Shock Resistance
500m/s^2, 3 times in each direction
Vibration Resistance
10-55Hz Double amplitude: 1.5mm, 2 hours in each direction X,Y,Z)
Termination
Cable Type (stdnard 2M cabel length), connector cable type, connector type
Colour
NPN:Green, NPN:Navy
Protection Class
IP67
Approvals
CE
Weight
130g
Factory NAck Qty
1
Datasheet
Product Datasheet
Product Datasheet
VFD4A2MS43ANSAA, 3 Phase Variable Frequency Drive, 460VAC, 1.5kW, 3.2 Amp (Normal Duty)/3.5 Amp (Heavy Duty), 460VAC L-L, 0.1-599 Hz, 142x72x143mm
Features
3 Phase VFD/VSD
4-20mA, 0-5V, 0-10V Proportional Input Control
7 x Digital Input
2 x STO Inputs
Fully enclosed IP20 (Optional IP40)
Small frame Size
Applications
Fan Motor Control
Production Lines
Transportation
Controlled Power Applications
Suitable for extreme environments such as mining
Â
Specification
Delta Part Number
VFD4A2MS43ANSAA
Rated Operation Temperature
50°C (With Derating)
Configuration
3 Phase ACÂ Drive
Control Voltage
4-20mA, 0-20mA, 0-10V
Digital Inputs
7 x Mix / 2 x STO
Load Current
3.2 Amp(Normal Duty) / 3.5 Amp(Heavy Duty) Per Phase
Control Range
0.1-599 Hz
Dimensions
207x109x154mm
Mounting Style
Panel Mount
Supply Voltage Range
323-528VAC
Soft Start
0-6000s
Termination Style
Screw
Unit Weight
2.5kg
Factory Pack Qty
1
Datasheet
MS300 Brochure
User Manual
Â
Eastron SDM630MCT-2L-TCP, Dual 3 Phase DIN Rail Mount kWh Meter with Easyclick, 2 x 3 Phase or 6 x Single Phase, 240VAC aux, Class 1, 100mA RJ12 CT Connect, w/RS485 Modbus RTU Comms
100mA RJ12 CT 2 x 3 Phase Connect
100mA RJ12 6 x Single Phase RJ12 CT with adapter
RS 485 communication up to 38,400 bit/s as standard
True RMS values of currents and voltages
Easyclick CT system reduces installation costs
Dual Metering System Reduces Cost and saves space
Â
The meter is intended for measuring, and monitoring 2 x three phase or 6 x single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals.
Â
Features :
System Accuracy Class B/Class1
Measurement of Active and Reactive Power
Modbus RTU communication up to 38,400 bit/s communication
Graphic LCD with illumination
Specification
Eastron Europe Part Number
SDM630MCT-2L-TCP
Functions
Dual Three Phase Energy Meter/ 6 x Single Phase Energy Meter
Supply Voltage
230V L-N +/-15% < 5VA
Nominal Measurement Range
415V L-L 230V L-N, 1/5 Amp +/-15%
Maximum Measurement Range
480V L-L 230V L-N, 1/5 Amp
Nominal CT Current Input
100mA via RJ12 Easyclick CT's
Pulse Output
N/A
Tariff Input
N/A
Accuracy
Class 1 (I,U,F,kW,kWh) Class 2 (Reactive)
Mounting
Din Rail
Real Time Clock
1min/month (30ppm)
Internal Memory
N/A
Dimensions
72mm x 100mm x 66mm (4 modules wide)
Isolation
4kV
RS485
2400-38400 b/s (400ms Response Time)
Weight
600g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Safety
IP51(Indoor)
Enclosure Material
Noryl with fire protection to UL94-V-O. Self extinguishing
Enclosure Size
DIN 42880 4 Modules
Operating Temperature
-20 →+70 °C
Â
Documents
Product Datasheet
User Manual
Modbus Protocol
Suitable RJ12 CT's
Three Phase J12 Connected CT's
Split Core Single Phase CT's for RJ12 Connected Meters
Modbus Utility
EEM Meter Setting Software Utility
Crydom HS211 + A2450EG, Panel or slide on Din Rail Solid State Relay, 24VAC Control Input, LED Status, 24-280VAC Output, 25 Amps
Features
Ratings from 25A to 125 Amp @24-280 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Panel Mount
Din Rail Mount
Spec
Part Number
HS211 + A2450EG
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
18-36VAC
Load Current
25 Amp (rms) @ 40 Deg C
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
Din Rail or Panel Mount
Load Voltage Range
24-280VAC
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Screw Terminals
Dimensions
L:81mm x W:45mm x D:73.4mm
Unit Weight
296g
Factory Pack Qty
20
Â
Datasheet
HS211
A2450E-G
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies