Search results for "���̺��볲������ �νν������� SSSREO �Ť�H���� �̷���ǰ ƯSA���ø�ī ĥ��ְ�����Ƽ �̷��� ���ø�ī ����ũ�ν��鳲��"
-
KS32/24-48D3N & F41F-1Z-C2-1, Slim Solid State Relay & Socket with Screw Terminals 24VDC Input, 3 Amp @ 48VDC
Keysolu KS32/24-48D3N & F41F-1Z-C2-1, Slim Solid State Relay & Socket with Screw Terminals 24VDC Input, 4 Amp @ 48VDC Features Multirange input 12-24VAC/DC Nominal Load Rating 6 Amp @ 30VDC/250VAC DIN Rail Mount Ultra slim package UL Listed (Keysolu make) CE Compliant to IEC 60664 IP67 Specification Fastron Part Number KS32/24-48D3N & F41F-1Z-C2-1 Switching Type 240VAC Control Input 24VDC+/-10% Current @ Rated Voltage 3 Amp Contact Arrangement 1 SPST Approvals UL,CE Dimensions 76.6 x 94.7 x 6.2 Ingress Protection IP20 Control Input Power 25mA Relay Type Keysolu KS32 24-24Z2 Termination Style Spring Terminals Unit Weight 60g Factory Pack Qty 100 Datasheet Relay Base Datasheet Relay Datasheet
$32.00
$37.76 inclGST -
EZ240D5R, Solid State Relay, 4-15VDC control, 5A, 24-280VAC Load, Random Crossing, Faston
Crydom EZ240D5R, Solid State Relay, 4-15VDC control, 5A, 24-280VAC Load, Random Crossing, Faston Features Ratings from 5A to 18 Amp @ 600 VAC Faston terminals for easy installation SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CSA/VDE Approved, CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriers AC & DC control types Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Crydom Part Number EZ240D5R Switching Type Zero Crossing ROHS Yes (Details) Control Voltage 4-15VDC Load Current 5 Amp (rms) Surge Capability 40 Amp (peak) Special Feature Faston terminals Mounting Style Panel Mount Load Voltage Range 24-280VAC EMC Compliant Level 3 Termination Style Faston Unit Weight 43g Factory Pack Qty 20 Datasheet Product Datasheet Equivalent Contact Us for Possible Replacement App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
$40.70
$48.03 inclGST -
DRSED, Din Rail Mount socket 5 Pin for ED series 5 Pin Relay Style SSR's
DRSED Din Rail Mount socket for ED series 5 Pin Relay Style SSR's Datasheet Product Datasheet Suitable SSR ED06C5
$16.70
$19.71 inclGST -
DR06D12, Solid State Relay, 4-32VDC control, 12 Amp 1-60VDC Output, Slimline, Din Rail Mount, LED status Indicator
Crydom DR06D12, Solid State Relay, 4-32VDC control, 12 Amp 1-60VDC Output, Slimline, Din Rail Mount, LED status Indicator Features Ratings from 3 Amp, 1-100VDC, 1-60VDC, 24-280VAC, 48-600VAC DIN Rail Mount SCR output for reliable AC switching, or Mosfet for DC Switching Ultra slim package UL/CSA/VDE Approved, CE Compliant to EN60950-1 EMC compliant to Level 3 Epoxy free design Spec Crydom Part Number DR06D12 Switching Type DC ROHS Yes (Details) Control Voltage 4-32VDC Load Current 12 Amp (rms) Surge Capability (10ms) 60 Amp (peak) Special Feature LED Status Indicator Mounting Style DIN Rail Mount Load Voltage Range 1-60VDC EMC Compliant Level 3 Termination Style Screw Unit Weight 38g Factory Pack Qty 20 Datasheet Product Datasheet Equivalent DRA1-CMX60D10 ED06C5 ED06D5 App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
$136.00
$160.48 inclGST -
HS053, Panel Mount Heatsink, 0.5 Deg C per Watt for up to three single phase, or one 3 phase Solid State Relay,
Free Aus Post Shipping for $300 SpendCrydom HS053, Panel Mount Heatsink, 0.5 Deg C per Watt for up to three single phase, or one 3 phase Solid State Relay, Features DIN Rail or Panel Mount heat sink types Suitable for SSR Mounting Pre drilled for 3 x single or 1 x 3 phase SSR Black anodised for professional look Spec Crydom Part Number HS053 Mounting Type Panel Mount Suitable SSR Rating 40/50 Amp Dimensions (without SSR) L:152.4mm x W:152.4mm x 88.9mm Thermal Impedance (°C/W) 0.5 Load Current @ 40 Deg C 82.5 Amp Load Current @ 50 Deg C 64 Amp Unit Weight 1510g Factory Pack Qty 10 Datasheet Product Datasheet Mounted Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
GN350DSZ, SSR 3 Phase 4-32VDC Control, 50A, 48-530VAC Load, LED Status Indicator, IP20 Cover
Crydom GN350DSZ, SSR 3 Phase 4-32VDC Control, 50A, 48-530VAC Load, LED Status Indicator, IP20 Cover Features Ratings from 25A to 50 Amp @ 70-480 VAC SCR output for heavy industrial loads Zero voltage or Instantaneous turn-on outputs UL/CE/ROHS Approved IP20 Cover Available AC & DC control types Direct bond copper substrate Direct power lead frame Epoxy free design Spec Crydom Part Number GN350DSZ Switching Type Zero Crossing ROHS/CE/UL Yes Control Voltage 4-32VDC Load Current 50 Amp (rms) per Phase Surge Capability 597 Amp (peak) Special Feature LED Status Indicator + IP20 Cover Mounting Style Panel Mount Load Voltage Range 48-530VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 315g Factory Pack Qty 10 Datasheet Product Datasheet Equivalent Contact Us App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
$518.33
$611.63 inclGST -
SSC1000-25-12, 8-16VDC Input, 1kV, 25Amp DC Output SSR
Free Aus Post Shipping for $300 SpendCrydom SSC1000-25-12, 8-16VDC Input, 1kV, 25Amp DC Output SSR Features Ratings from 20 Amp @ 1-1000VDC Mosfet output for reliable DC switching Multiple modules can be wired in parallel for higher currents UL/CSA/VDE Approved, CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriers Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Crydom Part Number SSC1000-25-12 Switching Type DC Load ROHS Yes (Details) Control Voltage 8-16VDC Load Current 25 Amp DC Surge Capability (10ms) 75 Amp DC Special Feature None Mounting Style Panel Mount Load Voltage Range 0 - 1000VDC EMC Compliant Level 3 Termination Style Screw Unit Weight 82g Factory Pack Qty 20 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
D2410-B, SSR 3-32VDC Control input, 10A 90-280VAC, Normally Closed
Free Aus Post Shipping for $300 SpendCrydom D2410-B, SSR 3-32VDC Control input, 10A 90-280VAC, Normally Closed Features Ratings from 25A to 125 Amp @ 24-280 VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CSA/VDE Approved, CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriers AC & DC control types Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Crydom Part Number D2410-B Switching Type Zero Crossing, Normally Closed ROHS Yes (Details) Control Voltage 3-32VDC Load Current 25 Amp (rms) Surge Capability 239 Amp (peak) Special Feature Normally Closed Mounting Style Panel Mount Load Voltage Range 24-280VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 75g Factory Pack Qty 20 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
DR2260A20V, Solid State Contactor SSR, Single Phase 90-280VAC Control, 20A, 48-600VAC Load, Din Rail Mount
Free Aus Post Shipping for $300 SpendCrydom DR2260A20V, Solid State Contactor SSR, Single Phase 90-280VAC Control, 20A, 48-600VAC Load, Din Rail Mount Features Ratings from 20A to 35 Amp @ 48-660 VAC Contactor Style for retrofit SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CSA/VDE Approved, CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriers AC & DC control types Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Crydom Part Number DR2260A20V Switching Type Zero Crossing ROHS Yes (Details) Control Voltage 90-280VAC Load Current (single unit) 20 Amp (rms) @ 40 Deg C Ambient, 16 Amp (rms) @ 50 Deg C Ambient Load Current (multiple units) 20 Amp (rms) @ 40 Deg C Ambient, 16 Amp (rms) @ 50 Deg C Ambient Surge Capability 286 Amp (peak) Special Feature Contactor Style Terminals Mounting Style DIN Rail Mount Load Voltage Range 48 - 660VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 298g Factory Pack Qty 20 Datasheet Product Datasheet Alternatives SSR Style CKRD4830 App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
MT550-SSHFNAASS (DIN), Multifunction Power Transducer, Class 0.1, 4 Wire, 50-500V L-N, 5A AC Input 16-400Hz, 70-300VDC or 80-276VAC Aux Input, 2 Programmable analogue outputs, 2 Pulse Outputs, USB, Ethernet, RS485 Comms
Free Aus Post Shipping for $300 SpendIskra Doo MT550-SSHFNAASS (DIN), Multifunction Power Transducer, Class 0.1, 4 Wire, 50-500V L-N, 5A AC Input 16-400Hz, 70-300VDC or 80-276VAC Aux Input, 2 Programmable analogue outputs, 2 Pulse Outputs, USB, Ethernet, RS485 Comms Class 0.1 Active, Class 0.2 Reactive (EN 60688) RS485 Comms as standard Up to 4 I/O Modules (analogue output, Multiple break point, non-linear characterstics Automatic range of nominal current up to 12.5 A (Includes 5A/1A CT Input) and nominal voltage up to 600 V L-N Adjustable tariff clock, display of electric energy consumption in optional currency RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Measurements of energy in all 4 quadrants Average values of measurands per interval Certified ship version available The Power Transducer is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : Measurement of instantaneous values of more than 140 quantities (U, I, P, Q, S, PF, PA, f, f, MD, etc.). Accuracy Class 0.5s Active, Class 0.2 Reactive (EN 60688), Class 0.1 on Comms 32 Adjustable Alarms Input frequency 50/60 Hz or 400 Hz RS 232/RS485 communication up to 115,200 bit/s (Optional) or USB communication as standard MODBUS RTU communication protocol Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs) Universal Supply 24-300VDC or 40-276VAC Automatic range of nominal current up to 12.5 A and nominal voltage up to 600 V User-friendly PC MiQen software Optional Remote Display Support Specification Iskra Doo Part Number MT550-SSHFNAASS (DIN) Functions 3 Phase Power Transducer Supply Voltage 24-300VDC or 40-276VAC Nominal Measurement Range 500V L-N, 5 Amp Maximum Measurement Range 600V L-N, 12.5 Amp Alarm N/A Tariff Input N/A Output(s) 2 x Analogue Accuracy Class 0.2 (I,U,F,PF,θ,THD) Class 0.1(Active), Class 0.2 (Reactive) Battery Backup N/A Real Time Clock 1min/month (30ppm) Terminations EU Style Clamp Terminals Isolation 3.5kV Comms USB (standard) RS232 2400-115200 b/s (RS485 Optional) Weight 900g Enclosure Material UL94, Factory Pack Qty 1 EU Directives EN61010, EN60688,EN61326-1,60529,60068-2-1/-2/-6/-27/-30 Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20 Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet Software MiQen Setting Software
-
MC774 S HEWNNN, Power Quality Analyser Class A, 32uS sampling, 16-400Hz, Time Sychronisation support, 80-276VAC or 70-300VDC Power Supply, Three Independent Comm Ports, GPS, IRIG-B, and NTP Time, Up to 20 Input and Outputs, Ethernet and USB Comms
Free Aus Post Shipping for $300 SpendIskra Doo MC774 S HEWNNN, Power Quality Analyser Class A, 32uS sampling, 16-400Hz, 140 Parameter Measurement, Time Sychronisation support, 80-276VAC or 70-300VDC Power Supply, Three Independent Comm Ports, GPS, IRIG-B, and NTP Time, Up to 20 Input and Outputs, Ethernet and USB Comms, 1 x Status and 1 x Relay Output Class A Instrument Automatic range of nominal current up to 12.5 A (Includes 5A/1A CT Input) and nominal voltage up to 1000rms V L-N 50/60Hz Adjustable tariff clock, display of electric energy consumption in optional currency Optional RS 232/RS 485 communication up to 115,200 bit/s or Ethernet communication The POwer Quality Analyser is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : Measurement of instantaneous values of more than 140 quantities (U, I, P, Q, S, PF, PA, f, f, MD, energy, energy price by tariffs, etc.). Accuracy class 0.5 or 0.2 (on demand) Measurement of 40 minimal and maximal values in different time periods Optional 32 adjustable alarms Optional wide frequency range from 16 Hz to 400 Hz Optional RS 232/RS 485 communication up to 115,200 bit/s or Ethernet communication Optional MODBUS and DNP3 communication protocol MMC memory card for setting and upgrading the meter Up to 20 inputs or outputs (analogue outputs, pulse outputs, alarm outputs, tariff inputs) 1 Status and 1 Relay Output Universal or AC power supply Graphic LCD 128 x 64 dots with illumination Automatic range of nominal current up to 5 A and nominal voltage up to 750 V Adjustable tariff clock, display of electric energy consumption in optional currency Multilingual support User-friendly PC MiQen software 128 samples in one period Measurement of THD on Current or Voltage from 0 to 400% Measure to the 65th Harmonic Specification Iskra Doo Part Number MC774 S HEWNNNT Functions Power Quality Analyser, Energy Meter, Power Transducer, Network Recorder/Analyser Supply Voltage 240VAC < 5VA Nominal Measurement Range 750Vrms L-N, 5 Amp 50/60Hz Maximum Measurement Range 1000Vrms L-N, 12.5 Amp 50/60Hz Alarm N/A (Optional 4 Relays, 32 Alarms, 4 Groups) Analogue Output N/A (Optional 4 x 20mA) Digital Input N/A (Optional 4 x 230VAC/DC,75..130VAC/DC..5..48VAC/DC) Pulse Output N/A (Optional) Pulse Input N/A (Optional) Bistable Switch/Latching Relay Alarm N/A (Optional) Status (Watchdog) Output N/A (Optional) Tariff Input N/A (Optional 4 x 230VAC/DC,75..130VAC/DC..5..48VAC/DC) Accuracy Class 0.5 (I,U,F,PF,θ,THD) (Class 0.2 Optional) Class 1(Active), Class 2 (Reactive) Battery Backup Supercap Real Time Clock 1min/month (30ppm) Internal Memory 8MB MMC up to 1GB Isolation 3.7kV Ethernet Yes (RJ45 10/100Mbit/s) USB Yes (2400-115200 b/s) RS232/RS485 Optional Weight 600g Certification UL, CSA, ROHS Factory Pack Qty 1 EU Directives Degree on electrical equipment designed for use within certain voltage limits URLRS 53/00 (Directive 73/23/EEC on low voltage): SIST EN 61010-1:2002 Safety Requirement for electrical equipment for measurement, control and laboratory use, part1 : general requirement Decree on electromagnetic Compatibility (EMC) URLRS 61/00 (Directive 89/336/EEC on electromagnetic compatibility): SIST EN 61036 item 4.5: 1998 Meters for active energy (class 1 and 2) Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP52 (IP00 for terminals) in compliance with SIST EN 60529:1997 Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22 Datasheet Product Datasheet User Manual
-
PF480D25, SSR SIP, 4-15VDC Control, 25A, 48-530VAC Load
Free Aus Post Shipping for $300 SpendCrydom PF480D25, SSR SIP, 4-15VDC Control, 25A, 48-530VAC Load Features Ratings up to 25 Amp @ 660VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CSA/VDE Approved, CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriers AC & DC control types Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Crydom Part Number PFE480D25 Switching Type Zero Crossing ROHS Yes (Details) Control Voltage 4-15VDC Load Current 25 Amp (rms) Surge Capability 250 Amp (peak) Special Feature None Mounting Style PCB Mount Load Voltage Range 48-480VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 25g Factory Pack Qty 20 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here Accessories Din Rail Holder App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement