Fastron Electronics G2R-4P-220VAC, 4-Pole, 63A Dual Power Automatic Transfer Switch (ATS)
Austomatic Trasnfer Switches are designed to meet the requirements of heavy duty applications where backup power is used and required to operate continuously.
Features :
High contact reliability at low voltages
High electrical and mechanical endurance and high switching capacity
Two, Four and Three-pole versions
Ratings from 6 Amp to 63 Amp, 220/400VAC
CE Approved
Advantages :
Saves costs of expensive replacement
Long electrical life
High safety
No risk of dangerous voltage
Less maintenance and downtime
Specification
Fastron Electronics Part Number
G2R-4P-220VAC
Functions
4 Pole Automatic Transfer Switch (ATS)
Nominal Voltage
220/230VAC @ 50/60Hz
Current Carrying Capacity
63 Amp Continuous @ 55 Deg C
Main Contacts
4 x NO
Trip Delay Time
<50ms
Electrical Life
200,000 Ops
Operating Temperature
-5 to 40 Deg C
Mechanical Operations
8000 Ops
Approvals
CE
Weight
500g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Catalogue
Fastron Electronics G2R-63 II-220VAC, 2-Pole, 63A Dual Power Automatic Transfer Switch (ATS)
Austomatic Trasnfer Switches are designed to meet the requirements of heavy duty applications where backup power is used and required to operate continuously.
Features :
High contact reliability at low voltages
High electrical and mechanical endurance and high switching capacity
Two, Four and Three-pole versions
Ratings from 6 Amp to 63 Amp, 220/400VAC
CE Approved
Advantages :
Saves costs of expensive replacement
Long electrical life
High safety
No risk of dangerous voltage
Less maintenance and downtime
Specification
Fastron Electronics Part Number
G2R-63 II-220VAC
Functions
2 Pole Automatic Transfer Switch (ATS)
Nominal Voltage
220/230VAC @ 50/60Hz
Current Carrying Capacity
63 Amp Continuous @ 55 Deg C
Main Contacts
2 x NO
Trip Delay Time
<50ms
Electrical Life
200,000 Ops
Operating Temperature
-5 to 40 Deg C
Mechanical Operations
8000 Ops
Approvals
CE
Weight
500g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Catalogue
Fastron Electronics W2R-2P 32A 220V, 2-Pole, 32A Dual Power Automatic Transfer Switch (ATS) with Indicator and Status Outputs
Austomatic Trasnfer Switches are designed to meet the requirements of heavy duty applications where backup power is used and required to operate continuously.
Features :
High contact reliability at low voltages
High electrical and mechanical endurance and high switching capacity
Two, Four and Three-pole versions
Ratings from 6 Amp to 63 Amp, 220/400VAC
CE Approved
Advantages :
Saves costs of expensive replacement
Long electrical life
High safety
No risk of dangerous voltage
Less maintenance and downtime
Specification
Fastron Electronics Part Number
W2R-2P 32A 220V
Functions
2 Pole Automatic Transfer Switch (ATS) withj indicator and status outputs
Nominal Voltage
220/230VAC @ 50/60Hz
Current Carrying Capacity
63 Amp Continuous @ 55 Deg C
Main Contacts
2 x NO
Trip Delay Time
<50ms
Electrical Life
200,000 Ops
Operating Temperature
-5 to 40 Deg C
Mechanical Operations
8000 Ops
Approvals
CE
Weight
500g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
FP075080P G2, 750/5 Amp Split Core CT, Class 1, 2.5VA Series Clip On Current Transformer
Features
Quick Release Split Core System
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
FP075080P G2
Technology
Split Core AC Clip On Current Transformer
Ratio
750/5
Aperture Size
53 x 83.5mm
VA Rating
2.5VA
Accuracy Class
Class 0.5
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10°C / 50°C
Continuous Current (max)
750Amp x 1.2
Termination Style
Screw
Approvals
CE
Unit Weight
1150g
Factory Pack Qty
1
Datasheet
Product Datasheet
Installation Guide
FP020080P G2, 200/5 Amp Split Core CT, Class 1 2VA Series Clip On Current Transformer
Features
Quick Release Split Core System
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
FP020080P G2
Technology
Split Core AC Clip On Current Transformer
Ratio
200/5
Aperture Size
53 x 83.5mm
VA Rating
1.5VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10°C / 50°C
Continuous Current (max)
200Amp x 1.2
Termination Style
Screw
Approvals
CE
Unit Weight
1150g
Factory Pack Qty
1
Datasheet
Product Datasheet
Installation Guide
FP020030P G2, 200/5 Amp Split Core CT, Class 1 1.5VA Series Clip On Current Transformer
Features
Quick Release Split Core System
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
FP020030P G2
Technology
Split Core AC Clip On Current Transformer
Ratio
200/5
Aperture Size
25 x 36.5mm
VA Rating
1.5VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10°C / 50°C
Continuous Current (max)
200Amp x 1.2
Termination Style
Screw
Approvals
CE
Unit Weight
1150g
Factory Pack Qty
1
Datasheet
Product Datasheet
Installation Guide
FP015030P G2, 150/5 Amp Split Core CT, Class 1, 1VA Series Clip On Current Transformer
Features
Quick Release Split Core System
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
FP015030P G2
Technology
Split Core AC Clip On Current Transformer
Ratio
150/5
Aperture Size
25 x 36.5mm
VA Rating
1VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10°C / 50°C
Continuous Current (max)
150Amp x 1.2
Termination Style
Screw
Approvals
CE
Unit Weight
1150g
Factory Pack Qty
1
Datasheet
Product Datasheet
Installation Guide
FP010030P G2, 100/5 Amp Split Core CT, Class 1, 1VA Clip On AC Current Transformer, 25 x 36.5mm Aperture, Dimension 97 x 109 x 34mm
Features
Quick Release Split Core System
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
FP010030P G2
Technology
Split Core AC Clip On Current Transformer
Ratio
100/5
Aperture Size
25 x 36.5mm
VA Rating
1VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10°C / 50°C
Continuous Current (max)
100Amp x 1.2
Termination Style
Screw
Approvals
CE
Unit Weight
1150g
Factory Pack Qty
1
Datasheet
Product Datasheet
Installation Guide
FP050125P, 500/5 Amp Split Core CT, Class 0.5 2.5VA Series Clip On Current Transformer
Features
Quick Release Split Core System
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Electronics Part Number
FP050125P
Technology
Split Core AC Clip On Current Transformer
Ratio
500/5
Aperture Size
85 x 120mm
VA Rating
2.5VA
Accuracy Class
Class 0.5
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10°C / 50°C
Continuous Current (max)
500Amp x 1.2
Termination Style
Screw
Approvals
CE
Unit Weight
1150g
Factory Pack Qty
1
Datasheet
Product Datasheet
Installation Guide
FP400160P G2, 4000/5 Amp Split Core CT, Class 0.5 15VA Series Clip On Current Transformer
Features
Quick Release Split Core System
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Electronics Part Number
FP400160P G2
Technology
Split Core AC Clip On Current Transformer
Ratio
4000/5
Aperture Size
83 x 163.5mm
VA Rating
15VA
Accuracy Class
Class 0.5
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10°C / 50°C
Continuous Current (max)
4000Amp x 1.2
Termination Style
Screw
Approvals
CE
Unit Weight
1150g
Factory Pack Qty
1
Datasheet
Product Datasheet
Installation Guide
Fastron FP030030P G2, 300/5 Amp Split Core CT, Class 0.5 2.5VA AC Clip On Current Transformer, 25 x 36.5mm Aperture, Dimension 97 x 109 x 34mm
Features
Quick Release Split Core System
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
FP030030P G2
Technology
Split Core AC Clip On Current Transformer
Ratio
300/5
Aperture Size
25 x 36.5mm
VA Rating
1.5VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10°C / 50°C
Continuous Current (max)
300Amp x 1.2
Termination Style
Screw
Approvals
CE
Unit Weight
1150g
Factory Pack Qty
1
Datasheet
Product Datasheet
Installation Guide
FP063080P G2, 630/5 Amp Split Core CT, Class 1 3VA Series Clip On Current Transformer
Features
Quick Release Split Core System
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
FP063080P G2
Technology
Split Core AC Clip On Current Transformer
Ratio
630/5
Aperture Size
53 x 83.5mm
VA Rating
3VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10°C / 50°C
Continuous Current (max)
630Amp x 1.2
Termination Style
Screw
Approvals
CE
Unit Weight
1150g
Factory Pack Qty
1
Datasheet
Product Datasheet
Installation Guide