Advanced Energy Thyro-A-3A-400-16-H3, Three Phase SCR Controller 16 Amp 400VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control only
Features
400VAC +10/-57% Line to Line Voltage, Current or Power Control
Smallest footprint on the market
Built in Fuses
3 Phase, Phase Angle & Burst Controller with SWITCH operation mode
SWITCH between Phase(VAR) or Burst(TAKT) control modes
(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control
Removable Cover
USB Configuration/Bias Setting
Potentiometer Adjustments
Synchronisation Function for Multiple TAKT Sync
Applications
Electrical Ovens, Kilns, or Furnaces
Primary Control of Transformer Loads in Phase or Burst Fire mode
Resistive Loads up to 6:1 Hot/Cold Ratio
AC Soft Starter (VAR Mode Combined with PLC)
Power Regulation Applications
Electric Boilers
Brewery Heating
Industrial Light Dimming
Suitable for extreme environments such as mining
Series Optional Features
For HRL
Current Control/Feedback
Programmable Relay Alarm Output
Load Monitoring
Analogue Output
For HRLP
As above with Power Control Feedback
Communication Options
Standard Thyro Bus Module
BasicBus Module
Specification
Advanced Energy Part Number
Thyro-A-3A-400-16-H3
Approvals
CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC
Control Accuracy
3% at rated voltage
Rated Operating Temperature
45°C
Temperature Derating
0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C
SCR Configuration
Three Phase AC Switch
Control Modes
Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request)
Control Input
4(0)-20mA, 0(1)-5V, 0(2)-10V, POT
Load Current
16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)
Control Range
0-100%
Options
Conformal Coating for Gas or High Humidity Environments
Mounting Style
Panel Mount
Supply Voltage Range
400VAC +10/-57% (-57% with 24VDC Aux Supply)
Soft Start
Via PLC input
Termination Style
Screw
Unit Weight
2.1 to 74kg
Factory Pack Qty
1
Technical Docs
Brochure
User Manual
2 Leg Control Application Blog
Thyro A Series Quick Installation Guide
Setting Up Comms on Thyro A Series Controllers
Anybus Device Ethernet IP Setup Guide
Advanced Energy Thyro-A-2A-400-30-H3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 30Amp 400VAC +10/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control only
Features
400VAC +10/-57% Line to Line Voltage, Current or Power Control
Smallest footprint on the market
Built in Fuses
3 Phase, 2 Leg Economical Burst Controller Firing Mode
(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control
Removable Cover
USB Configuration/Bias Setting
Potentiometer Adjustment
Synchronisation Function
Applications
Electrical Ovens, Kilns, or Furnaces
Primary Control of Transformer Loads in Phase or Burst Fire mode
Resistive Loads up to 6:1 Hot/Cold Ratio
AC Soft Starter (Combined with PLC)
Power Regulation Applications
Electric Boilers
Brewery Heating
Industrial Light Dimming
Suitable for extreme environments such as mining
Series Optional Features
For HRL
Current Control/Feedback
Programmable Relay Alarm Output
Load Monitoring
Analogue Output
For HRLP
As above with Power Control Feedback
Communication Options
Standard Thyro Bus Module
BasicBus Module
Specification
Advanced Energy Part Number
Thyro-A-2A-400-30-H3
Approvals
CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC
Control Accuracy
3% at rated voltage
Rated Operating Temperature
45°C
Temperature Derating
0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C
SCR Configuration
Single Phase AC Switch
Control Modes
2 Leg Burst(TAKT) for low dissipation
Control Input
4(0)-20mA, 0(1)-5V, 0(2)-10V, POT
Load Current
16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)
Control Range
0-100%
Options
Conformal Coating for Gas or High Humidity Environments
Mounting Style
Panel Mount
Supply Voltage Range
400VAC +10/-57% (-57% with 24VDC Aux Supply)
Soft Start
Via PLC input
Termination Style
Screw
Unit Weight
2.1 to 74kg
Factory Pack Qty
1
Technical Docs
Brochure
User Manual
2 Leg Control Application Blog
Thyro A Series Quick Installation Guide
Setting Up Comms on Thyro A Series Controllers
Anybus Device Ethernet IP Setup Guide
Crouzet Automation 84872120, Single Phase Multi-Function Voltage Control Relay Under/Overvoltage Detection and Latching (Memory) Function- 35 mm HUL, 0.2-60 VAC/DC Measurement, 24/240 VAC/DC Supply
For under and overvoltage monitoring of Single phase AC or DC Voltages up to 600V
Features:
Control of AC and DC voltages
Automatic recognition of AC/DC
Measurement ranges from 0.2 V to 60 V
Choice between under and overvoltage
True RMS measurement
Selectable latching (memory) function
Specification
Crouzet Part Number
84872120 (Single Phase C-Lynx Voltage Monitoring Relay With DPDT Contacts)
Function
Undervoltage/Overvoltage
Nominal Voltage
1 x 0.2 - 60 VAC/DC
Digital Outputs
2 x C/O Relays, 250VAC/DC @ 8 Amp
Min Breaking Current
10mA/5VDC
Delay on Threshhold Crossing
0.1 → 3s (0, +10%)
Delay on Pickup
600ms
Alarm Delay on Time (max)
200ms
Reset Time
1500ms
Adjustable Hysteresis
5 - 50% of Threshhold
Maximum Measurement Cycle Time
30ms/True RMS Measurement
Measurement Accuracy
1%
Supply Voltage Range
Same as Measurement
Termination Style
Screw
Weight
170g
Certification
CE, UL, CSA, GL, ROHS
Factory Pack Qty
1
Over Voltage Category
3 in accordance with IEC/EN 60664-1
Pollution Degree
2 in accordance with IEC/EN 61131-2
Protection rating
IP40 (Front), IP20 (Rear)
Mechanical Resistance
Immunity to vibrations IEC/EN 60068-2-6, test Fc
Immunity to shock IEC/EN 60068-2-27, test Ea
Resistance to HF Interference
Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12
Conducted and radiated emissions
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Operating Temperature
-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22
Datasheet
Product Datasheet
Fastron Electronics FEFC205-50-T, 2 Stage EMI (RFI) Output Sine Wave Filter [Suitable For Inverter] for 3-phase 3 wire systems, 50 Amp, 400VAC
Suitable alternative to Schaffner FN3258(Input) or FN5020(Output) Series
3 phase Output Sine wave filter with high attenuation
400VAC +10%
Applications
VSD Drives or Controlled Rectifiers
For Industrial Applications
Suitable for use in equipment according to IEC/UL 60950
Medical Version Available
Specification
Fastron Part Number
FEFC205-50-T
Rated Voltage
400V
Rated Current
50A
Filter Stages
2 Stage (3 Phase 3 wire)
Operating Temperature
-25°C to 85°C
Filter Type
Excellent Attenuation for Sine Wave Output, Moderate Attenuation for input Line Filtering
Leakage Current
N/A
Mounting
Panel Mount - Case 32-7
Material
Metal
Termination Style
Screw
Weight
2.8kg
Factory Pack Qty
1
Protection Class
From front side IP 40 acc. to IEC 60529
Isolation
2.2kV
CE
Yes
Datasheet
Product Datasheet
FN500-5T0750G/0900P3 Phase 3 Wire, Variable Frequency Drive, 0.1 - 600 Hz, 75/90kW 150 Amp (Normal Duty)/176 Amp (Heavy Duty), 480VAC L-L, 570x340x320mm, RS485 Comms
Features
3 Phase 3 Wire VFD/VSD
2 x 4-20mA, 0-10V Proportional Input Control
8 x Digital Inputs
1 High Speed Digital Input
4 x Open Collector Outputs
1 x High Speed Open Collector Outputs
1 x C/O Relay Output
RS485
Fully enclosed IP20 (Optional IP40)
Small frame Size
Applications
Fan Motor Control
Production Lines
Transportation
Controlled Power Applications
Suitable for extreme environments such as mining
Specification
Fastron Part Number
FN500-5T0750G/0900P
Rated Operation Temperature
50°C (With Derating)
Configuration
3 Phase 3 Wire AC Variable Frequency Drive / Variable Frequnecy Drive
Control Voltage
4-20mA, 0-10V
Inputs
7 x DI / 1 x High Speed DI, 2 x Analogue
Load Current
150 Amp(Normal Duty) / 176 Amp(Heavy Duty) Per Phase
Control Range
0.1-600 Hz
Dimensions
530x340x320mm
Mounting Style
Panel Mount
Supply Voltage Range
320-480VAC L-L
Comms
RS485
Soft Start
0-6000s
Termination Style
Screw
Unit Weight
27kg
Factory Pack Qty
1
Datasheet
User Manual
LEM FRS 3000-SBI, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Bipolar Output
Features
Bandwidth DC to 1000kHz
Open loop transducer using Coreless Hall effect Technology
Compact and versatile
Panel mounting-Horizontal or Vertical
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
Low power consumption
Applications
Wind Turbines
Electrolyser
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications.
Specification
LEM Part Number
FRS 3000-SBI
Technology
Open Loop Coreless Hall Effect
Aperture
111.4 x 18.7mm Square
ROHS
Yes
Supply Voltage
+12...24VDC, Isolated
Load Current (RMS + DC)
3000 Amp
Measurement Range
+/-9000 Amp
Overload Rating
N/A
Output
4-20mA Bipolar
Isolation
5.3 kV
Bandwidth
DC-1000 kHz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-25°C / 85°C
Accuracy
1%
Termination Style
Molex 5045-04A
Unit Weight
1500g
Factory Pack Quantity
4
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Advanced Energy Thyro-A-2A-400-16-H3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 16Amp 400VAC +10/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control only
Features
400VAC +10/-57% Line to Line Voltage, Current or Power Control
Smallest footprint on the market
Built in Fuses
3 Phase, 2 Leg Economical Burst Controller Firing Mode
(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control
Removable Cover
USB Configuration/Bias Setting
Potentiometer Adjustment
Synchronisation Function
Applications
Electrical Ovens, Kilns, or Furnaces
Primary Control of Transformer Loads in Phase or Burst Fire mode
Resistive Loads up to 6:1 Hot/Cold Ratio
AC Soft Starter (Combined with PLC)
Power Regulation Applications
Electric Boilers
Brewery Heating
Industrial Light Dimming
Suitable for extreme environments such as mining
Series Optional Features
For HRL
Current Control/Feedback
Programmable Relay Alarm Output
Load Monitoring
Analogue Output
For HRLP
As above with Power Control Feedback
Communication Options
Standard Thyro Bus Module
BasicBus Module
Specification
Advanced Energy Part Number
Thyro-A-2A-400-16-H3
Approvals
CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC
Control Accuracy
3% at rated voltage
Rated Operating Temperature
45°C
Temperature Derating
0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C
SCR Configuration
Single Phase AC Switch
Control Modes
2 Leg Burst(TAKT) for low dissipation
Control Input
4(0)-20mA, 0(1)-5V, 0(2)-10V, POT
Load Current
16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)
Control Range
0-100%
Options
Conformal Coating for Gas or High Humidity Environments
Mounting Style
Panel Mount
Supply Voltage Range
400VAC +10/-57% (-57% with 24VDC Aux Supply)
Soft Start
Via PLC input
Termination Style
Screw
Unit Weight
2.1 to 74kg
Factory Pack Qty
1
Technical Docs
Brochure
User Manual
2 Leg Control Application Blog
Thyro A Series Quick Installation Guide
Setting Up Comms on Thyro A Series Controllers
Anybus Device Ethernet IP Setup Guide
ISKRA LETRIKA (MAHLE) 16.906.466 AMJ5710, AMJ5845 MAHLE DC Motor replacement Brush Set
MAHLE Part # MMX370
Specification
ISKRA (MAHLE) Part Number
16.906.466
ISKRA/LETRIKA/MAHLE
16.906.466
Voltage
12VDC
Rotation
Unidirectional
Unit Weight
0.5kg
Factory Pack Qty
1
Fastron FT-AV(0-150)-D-1, Signal Isolator/Conditioner, 0-150V AC input, 24VDC aux, 4-20mA Average RMS output
Non Adjustable, Fixed Input and output span
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Part Number
FT-AV(0-150)-D-1
Control Output
4-20mA Average RMS
Input
0-150VAC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
24VDC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics HF121-12/0.4-40-7%K, 40kVar 400VAC(0.95mH) 7% Detuned Reactor for Power Factor Correction Capacitor Banks, 0.95mH(400VAC) 1.526mH(525VAC)
Specification
Technical Features
HF121-12/0.4-40-7%K
Electrical
Voltage
400V/525V
Network Frequency
50/60Hz
Inductance (mH @ 400VAC)
0.95mH
Inductance (mH @ 525VAC)
1.526mH
Nominal Power
40kvar
Value of p%
7% (189Hz)
Type of Conductor
Aluminium/Copper(optional)
Tolerance L
5%
Linearity (5% L)
1.8 x In
Isolation Voltage
kV
Maximum Room Temperature
-10 to 45 Deg C
Internal isolation
Class F(155°C), Class H (180°C Optional)
Maximum Overload
Permanent
1.17 x In
Temporary
2 x In
Safety
Protection Thermostat
Opens at 90 °C
Degree Protection
IP00
Installation
Indoor
Standards
EN-60289, IEC60076
Weight
25kg
Datasheet
Product Datasheet
Installation Guide
HF121 Series Installation Guide
Shinko RAU-O Series Signal Conditioners
Universal Input (Thermocouple, RTD, DC Current, DC Voltage, Potentiometer) Signal Conditioner 100-240 VAC, 4-20mA output
4-digit display. Suit most industries including Temperature, Humidity, Pressure (0.25s response)
Tropicalised Version Available
UL/CSA Approved
Input signals can be converted to insulated 4 to 20 mA DC output (0.25s Response)
Each unit needs just 22.5mm width Din Rail space
EC Compliant (Details)
Specification
Shinko Part Number
RAU-O
Control Output
4-20mA Output
Input
Universal (TC, RTD, DC Amp, DC Volt, POT)
Special Function
3 Port Isolation for noisy environments
Option
RS485 Comms
Mounting Style
22.5 x 75mm Din Rail Mount
Supply Voltage
100 - 240VAC
Termination Style
Screw
Weight
230g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Datasheet
RA Series Brochure
RA Series User Manual
Delivery 2-3 weeks delivery if not in stock
Advanced Energy Thyro-A-2A-400-30-HRL3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 30Amp 400VAC +10/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit Option
Features
400VAC +10/-57% Line to Line Voltage, Current or Power Control
Smallest footprint on the market
Built in Fuses
3 Phase, 2 Leg Economical Burst Controller Firing Mode
(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control
Removable Cover
USB Configuration/Bias Setting
Potentiometer Adjustment
Synchronisation Function
Applications
Electrical Ovens, Kilns, or Furnaces
Primary Control of Transformer Loads in Phase or Burst Fire mode
Resistive Loads up to 6:1 Hot/Cold Ratio
AC Soft Starter (Combined with PLC)
Power Regulation Applications
Electric Boilers
Brewery Heating
Industrial Light Dimming
Suitable for extreme environments such as mining
Series Optional Features
For HRL
Current Control/Feedback
Programmable Relay Alarm Output
Load Monitoring
Analogue Output
For HRLP
As above with Power Control Feedback
Communication Options
Standard Thyro Bus Module
BasicBus Module
Specification
Advanced Energy Part Number
Thyro-A-2A-400-30-HRL3
Approvals
CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC
Control Accuracy
3% at rated voltage
Rated Operating Temperature
45°C
Temperature Derating
0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C
SCR Configuration
Single Phase AC Switch
Control Modes
2 Leg Burst(TAKT) for low dissipation
Control Input
4(0)-20mA, 0(1)-5V, 0(2)-10V, POT
Load Current
16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)
Control Range
0-100%
Options
Conformal Coating for Gas or High Humidity Environments
Mounting Style
Panel Mount
Supply Voltage Range
400VAC +10/-57% (-57% with 24VDC Aux Supply)
Soft Start
Via PLC input
Termination Style
Screw
Unit Weight
2.1 to 74kg
Factory Pack Qty
1
Technical Docs
Brochure
User Manual
2 Leg Control Application Blog
Thyro A Series Quick Installation Guide
Setting Up Comms on Thyro A Series Controllers
Anybus Device Ethernet IP Setup Guide