FTA-010-420-24, DC Current Transducer, 0-10 Amp , 4-20mA Unipolar Output, 24VDC supply, 21mm Aperture
FTA-010-420-24, DC Current Transducer, 0-10 Amp , 4-20mA Unipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, 0-10 Amp , 4-20mA Unipolar Output Features ⌀21mm Aperture DC Unipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- 0-10mA ~0-10A AC) 10uS Response (0-0-10A ~0-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-010-420-24 Technology DC Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) 0-10 Amp Response Time < 120mS Output Unipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
88974031, Millenium 3 Essential CB20-12I/8O R, 12 x On/Off inputs, Incl 6 analogue inputs, 8 x Static relay outputs incl 4 x PWM output, 24 VDC Supply, Green Display
Free Aus Post Shipping for $300 SpendCrouzet 88974031, Millenium 3 Essential CB20-12I/8O R, 12 x On/Off inputs, Incl 6 analogue inputs, 8 x Static relay outputs incl 4 x PWM output, 24 VDC Supply, Green Display Highly visible blue LCD with 4 lines of 18 characters and configurable backlighting More cost effective solution Allow the use of the entire library of specific functions blocs of the software workshop Extended temperature range (-20 °C →+70 °C) Analogue inputs 0-10 VDC, Potentiometer, NTC, LDR (0-20 mA/Pt100 with converters) Open to XN network communication extensions, digital I/O, analogue, Pt100 extensions HMI Screens Available Specification Crouzet Part Number 88974031 (CB20-12I/8O R) Analogue Inputs 0-10VDC (x6) Digital Inputs 12/24VDC (4.4mA @ 12VDC) (x16) Digital Outputs Relay, 5-30VDC,24-250VAC @ 10mA minimum (x10) PWM SSR Output 12-24VDC @ 500mA (x4) Expandable Yes LCD Display None Mounting Style DIN Rail Mount (124.6mm) Supply Voltage Range 24VDC (21.6 - 28.8VDC) Termination Style Screw Weight 350g Certification CE, UL, CSA, GL Factory Pack Qty 1 Over Voltage Category 3 in accordance with IEC/EN 60664-1 Pollution Degree 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Mechanical Resistance Immunity to vibrations IEC/EN 60068-2-6, test Fc Immunity to shock IEC/EN 60068-2-27, test Ea Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22 Datasheet Product Datasheet Selection Chart Software Crouzet Touch Soft V6.00.02.173 Software M3-soft-AC9-V3.1.2.0_ML Remote Control Software CVD_PC_V2_3_01_02 Crouzet Soft EVO EM4 1.12.01.14
-
FTA-300-420-24, Hall Effect DC Current Transducer, 0-300 Amp , 4-20mA Unipolar Output, 24VDC supply, 21mm Aperture
FTA-300-420-24, Hall Effect DC Current Transducer, 0-300 Amp , 4-20mA Unipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, 0-300 Amp , 4-20mA Unipolar Output Features ⌀21mm Aperture DC Unipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- 0-10mA ~0-10A AC) 10uS Response (0-0-300A ~0-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-300-420-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) 0-300 Amp Response Time < 10uS Output Unipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
FBS RK 24 ST-II, Slim Surge Protection Device For RS485, 2 Pole, 24VDC, 5kA per line @ Imax(8/20uS)(KA), -40 to +80 Deg C Operation; YD/T 1542, Nominal Discharge 5kA, Maximum Discharge 10kA, LPZ 1 -2 or higher, Slim 7mm Wide Module
FBS RK 24 ST-II, Slim Surge Protection Device For RS485, 2 Pole, 24VDC, 5kA per line @ Imax(8/20uS)(KA), -40 to +80 Deg C Operation; YD/T 1542, Nominal Discharge 5kA, Maximum Discharge 10kA, LPZ 1 -2 or higher, Slim 7mm Wide Module Application IT Systems Coarse and FIne Protection Industrial Control System Measurement System Device Control Specifications Trent part number FBS RK 24 ST-II Nominal Voltage 24VDC No of Poles 4 Category IEC / EN / VDE LPZ 0 -2 or higher Location of use IT Communications Line/signals Protection modes TX+/TX-/RX+/RX-/GND Additional Remote Contacts N/A Protective element MOV No Fault/Fault Indication N/A Surge discharge rating Per pole 5kA (8/20uS)9KA) Max, 10kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Weight 50g Standards IEC61643-21; GB 18802.21 ; YD/T 1542 Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$49.00
$57.82 inclGST -
88886516, Syr-Line Multirange Timer TMR 48 X, 11 Pin, Single Pole 5A CO (SPDT) Delay 0.02s - 300h, 12-240VDC, 24-240VAC, 48x48mm, Functions L, Li, G, Gi
Free Aus Post Shipping for $300 SpendCrouzet 88886516, Syr-Line Multirange Timer TMR 48 X, 11 Pin, Single Pole 5A CO (SPDT) Delay 0.02s - 300h, 12-240VDC, 24-240VAC, 48x48mm, Functions L, Li, G, Gi TMR 48 X Timers Syrline 48x48mm - 1 Relay 5A : Multi-Function Multi-range (0.02 s – 300 h) Multi-voltage (12-240VDC/24-240 V AC) 2 x CO relay outputs (Changeover) DIN Sized (48x48 mm) Housing Compact body (64.5 mm long) Water & Dust-proof (IP50) 11-Pin Multifunction Timers Include The Following : L, Li, G, Gi Specification Crouzet Part Number 88886516 Function Multifunction Timer L, Li, G, Gi Nominal Voltage 12 - 240VDC / 24 → 240 VAC Digital Output 2 x C/O (SPDT) (Changeover -Single Pole Double Throw), 250VAC/DC @ 5 Amp Min Breaking Current 10mA/12VDC Timing Ranges Selectable 0.02→300h Minimum Pulse Duration 30ms/100ms with load Repeatability 0.5% Reset Time 120ms Memory N/A Isolation 1kV Repetition Accuracy 0.5% Threshold Adjustment Range 10 → 100 % of the range Termination Style 11 Pin Base Weight 80g Certification CE, cULus,CCC, ROHS, Reach, WEEE Factory Pack Qty 1 Over Voltage Category 3 in accordance with IEC/EN 60664-1 Pollution Degree 2 in accordance with IEC/EN 61131-2 Protection rating IP50 (Front), IP40 (Rear) Mechanical Resistance Immunity to vibrations IEC/EN 60068-2-6, test Fc Immunity to shock IEC/EN 60068-2-27, test Ea Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22 Datasheet Product Datasheet
-
FTA-100-420-24, Hall Effect DC Current Transducer, 0-100 Amp , 4-20mA Unipolar Output, 24VDC supply, 21mm Aperture
FTA-100-420-24, Hall Effect DC Current Transducer, 0-100 Amp , 4-20mA Unipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, 0-100 Amp , 4-20mA Unipolar Output Features ⌀21mm Aperture DC Unipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- 0-10mA ~0-10A AC) 10uS Response (0-0-100A ~0-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-100-420-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) 0-100 Amp Response Time < 10uS Output Unipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
47A3D412(OBSOLETE) Temp Control Relay, PT100 Input Din Rail, 24-240VAC/DC, Relay output, Adjustable Setpoint -50 to 300 Deg C Range
Free Aus Post Shipping for $300 SpendGIC Controls 47A3D412 Temp Control Relay, PT100 Input Din Rail, 24-240VAC/DC, Relay output, Adjustable Setpoint -50 to 300 Deg C Range Feastures 3-digit display (0.5s response) CE/ROHS Approved Each unit needs just 17.5mm width Din Rail space EC Compliant Specification GIC Controls Part Number 47A3D412 Control Output Relay C/O 10 Amp Analogue Output 2 x 0-10V Input External PT100 Sensor (not supplied) Mounting Style 17.5 x 75mm Din Rail Mount Supply Voltage 24 - 240VAC/DC Termination Style Screw Weight 230g Factory Pack Qty 1 ROHS Yes CE Yes Datasheet Datasheet Alternative See FRW8-01
-
FTA-030-010-24, Hall Effect DC Current Transducer, +/-30 Amp , +/-10V Bipolar Output, 24VDC supply, 21mm Aperture
FTA-030-010-24, Hall Effect DC Current Transducer, +/-30 Amp , +/-10V Bipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-30 Amp , 4-20mA Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- +/-20mA ~+/-20A AC) 10uS Response (0-+/-20A ~+/-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-030-010-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-30 Amp Response Time < 120mS Output Bipolar +/-10V Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
FTA-300-420B-24, Hall Effect DC Current Transducer, +/-300 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture
FTA-300-420B-24, Hall Effect DC Current Transducer, +/-300 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-300 Amp , 4-20mA Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- +/-10mA ~+/-10A AC) 10uS Response (0-+/-300A ~+/-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-300-420B-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-300 Amp Response Time < 10uS Output Bipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
FRI8-05/A, Current Monitoring Relay AC 2-20 Amp, Adjustable Range, 9mm Aperture Universal 24-240VAC 24VDC
Free Aus Post Shipping for $300 SpendFastron FRI 8-05/A, Current Monitoring Relay AC 2-20 Amp, Adjustable Range, 9mm Aperture Universal 24-240VAC 24VDC FRI8-05/A Series serves to monitor AC currents 2,4,6,8,10,12,14,16,18,20 up to 20 Amp, and provides Relay alarm output with Over/Undercurrent selection by jumper. Can replace Crouzet 84871122 Features : ?? Current transformer is a part of the product. Inside this transformer there is a wire which senses the volume of flowing current Non Invasive measurement Galvanically separates monitored circuit Universal supply AC 24 - 240 V and DC 24 V Supply is galvanically separated from measuring current Current withstand up to 100 A Output contact: 1 x changeover/SPST 8 A Clamp terminals 1-phase, 1-MODULE, DIN rail mounting Applications : Heating bars in sliding rails Heating cables Indication of current flow Controlling of 1-phase motor consumption Specification Fastron Part Number FRI8-05/A Cable Aperture 9mm Voltage Range AC 24 - 240 V, DC 24 V (AC 50 - 60 Hz) Operating Range -15 %; ? % Current Range 1 - 20 A (AC 50 Hz) Current Trip Adjustment 2,4,6,8,10,12,14,16,18,20 Amp Setpoints Setting Accuracy 5 % Burden max. 1.5 VA Repeatability 1 % Temperature Drift 0.1%/??C Peak Overload (10s) 100 Amp Time delay T1 max. 500 ms Time delay T2 N/A Output SPDT Relay 8 Amp Number of contacts 1 x changeover/ SPDT (AgNi / Silver Alloy) Rating 8 A / AC1 Breaking capacity 2500 VA / AC1, 240 W / DC Inrush current 10 A Switching voltage 250 V AC1 / 24 V DC Min. breaking capacity DC 500 mW Indication of state red LED Mechanical life 1 x 107 Electrical life (AC1) 1 x 105 Other information ?? Operating temperature -20 ... ? ??C Storage temperature -30 ... ? ??C Electrical strength 4 kV (supply - output) Operating position any Mounting DIN rail EN 60715 Protection degree IP 40 from front panel / IP 10 terminals Overvoltage category III. Pollution degree 2 Max. cable size (mm )2 solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5 Dimensions 90 x 17,6 x 64 mm Weight 69 g Standards EN 60255-6, EN 61010-1, RoHS, CE Datasheet Product Datasheet Application Notes Monitoring relay FRI8-05/A serves to monitor current level in single phase AC circuits. Due to its fluent adjustment of release current, it is predestined for applications with necessity of current flow indication, and can be used as precedence relay. Output relay is off in normal state. In case the set current level is exceeded, it switches. Multi voltage supply is an advantage.
-
787302, E-STOP Safety Relay 24-240VAC/DC, 3 x NO Safety Contacts, 1 x NC Auxiliary Contact, PNOZ X2.8P C 24-240VAC/DC 3n/o 1n/c
Pilz 787302, E-STOP Safety Relay 24-240VAC/DC, 3 x NO Safety Contacts, 1 x NC Auxiliary Contact, PNOZ X2.8P C 24-240VAC/DC 3n/o 1n/c Safety Relay for Monitoring E-STOP Pushbuttons, safety gates and light barriers. Safety Features: Positive guides relay outputs, 3 x NO Safety Contacts, 1 x NC Auxiliary Contact Connection options for: E-Stop Pushbutton Safety Gate limit switch Reset button Light barriers LED Indicator for; Status channel 1/2 Supply Voltage Plug In connection terminals (cage clamp terminal or screw terminal) Redundant Circuit with in built monitoring Failsafe operation in case of component failure Correct Open/Close Operation is tested automatically in each on-off cycle Specification Pilz Part Number 787302, E-STOP Safety Relay PNOZ X2.8P C 24-240VAC/DC 3n/o 1n/c Function E-Stop Relay for E-stop, Gate or Lighting Supply Voltage 24 - 240 VAC/DC Relay Outputs 3 x NO Safety Contacts, 1 x NC Auxiliary Contact maximum Relay Current Safety Contacts 6 Amp, Auxiliary Contact 4 Amp Switch on Delay 340ms Delay on Energisation 10ms Termination Style Screw Weight 250g Certification UL Factory Pack Qty 1 Application Certification In accordance with EN 60947-5-1, EN 60204-1 and VDE 0113-1 Applications 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Datasheet Product Datasheet User Manual
$697.00
$822.46 inclGST -
84870700, Liquid Level Control Relay, 240VAC or 24VAC/DC Aux Supply, DPDT 5 Amp, 2 Level Control, With time delay adjustments, HNM 24-240V AC/DC
Crouzet 84870700, Liquid Level Control Relay, 240VAC or 24VAC/DC Aux Supply, DPDT 5 Amp, 2 Level Control, With time delay adjustments, HNM 24-240V AC/DC Level Switch, 110/240VAC or 24VAC/DC Aux Supply 2 x 5 Amp changeover/SPDT (AgNi / Silver Alloy) Relay Features : 1. one-level switch of conductive liquids 2. two-level switch of conductive liquids ! One-state device monitors one level, two-state device monitors two levels (switches on one level and switches off on another level) Choice of function PUMP UP, PUMP DOWN Adjustable time delay on the output (0.5 - 10 s) Sensitivity adjustable by a potentiometer (5-100 kÙ) Measuring frequency 10Hz prevents polarization of liquid and raising oxidation of measuring probes Galvanically separated supply voltage UNI 24.. 240 VAC/DC Output contact 1xchangeover/SPDT 8A/250V AC1 1-module type, mounting onto a DIN rail Specification Crouzet Part Number 84870210 Voltage Range 110/240VAC or 24VAC/DC Sensitivity (Input resistance) 50kOhm to 1MOhm Electrode Voltage 3.5 max Trip Adjustment Potentiometer Setting Accuracy 5 % Burden max. 12 VA Repeatability 1 % Temperature Drift 0.1%/°C Peak Overload (10s) 100 Amp Time delay T1 max. 400 ms Time delay T2 adjustable 0.1-10 s Control Type 1 or 2 Level Number of contacts 2 x changeover/ SPDT (AgNi / Silver Alloy) Rating 2 x 5 A / AC1 Breaking capacity 2500 VA / AC1, 250 W / DC Inrush current (3s) 10 A Switching voltage 250 V AC1 / 24 V DC Min. breaking capacity DC 500 mW Indication of state red LED Mechanical life 1 x 107 Electrical life (AC1) 1 x 105 Other information Operating temperature -20 ... +55 °C Storage temperature -30 ... +70 °C Electrical strength 4 kV (supply - output) Operating position any Mounting DIN rail EN 60715 Protection degree IP 40 from front panel / IP 10 terminals Overvoltage cathegory III. Pollution degree 2 Max. cable size (mm )2 solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5 Dimensions 90 x 17,6 x 64 mm Weight 109 g Standards EN 60255-6, EN 61010-1 Datasheet Product Datasheet Sensors for use with PLT Series Tank Level Sensors
$189.00