Search results for "tg탤 banonpi 당일급전가전내구제 바넌피유심내구제 경기도기초수급자비대면소액대출 정부특례보증긴급대출 선불폰유심개통방법"
-
T2 Protec T2-350-3+0-R, Uc = 350VAC SPD, 20kA (8/20uS). For 277VAC systems, 3 Pole + 0, DIN Rail Mount, Protection Modes L-PEN, Class II, Type 2, Type 1CA, Open Type 1 SPD Listed, with Remote Contact
Protec Protec T2 Protec T2-350-3+0-R, Uc = 350VAC Surge Protection Device (SPD) for AC Applications, 20kA (10/350uS), Varistor Voltage. For 277VAC systems, 3 Pole + 0, DIN Rail Mount, Protection Modes L-PEN, Class II, Type 2, Type 1CA, Open Type 1 SPD Listed, with Remote Contact Specifications Raycap part number T2 Protec T2-350-3+0-R Nominal Voltage Un 277VAC systems (for Uc = 350VAC ) No of Poles 3 Category IEC / EN / VDE Type 2/Open Type 1CA SPD Listed Location of use Sub Distribution Boards Protection modes L-PEN Additional Remote Contacts YES Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 20kA(8/20uS) 50kA Max Internal protection and safety Thermal disconnector in each MOV Standards IEC/EN 61643-11 Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$144.00
$169.92 inclGST -
Elite E500C-5402, Panel Mount Network Recorder with Harmonics (31st) & PQ Parameters, Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty
Secure Elite E500C-5402, Panel Mount Network Recorder with Harmonics (31st) & PQ Parameters, Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty Automatic range of nominal current up to 6 A (Includes 5A/1A CT Input) and nominal voltage up to 500 V L-L, 300V L-N Configurable 2 x Tariff Inputs or 2 x Pulse Outputs, or Alarm Outputs Dual Loggers, configurable for Instant or accumulated energy Configurable 2 x Tariff Inputs or 2 x Pulse Outputs, or Alarm Outputs RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Measurements of energy in all 4 quadrants Average values of measurands per interval RS 485 communication up to 38400 bit/s as standard Optional Protocol Modules Modbus TCP, BACNet IP, Profinet, SCADA EC61850 Optional Modules for Analogue outputs and Relay Alarms The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : Measurement of instantaneous values and accumulated energy. Includes Harmonics to the 31st Accuracy class 0.5S Dual Internal Loggers Measurement of 20 minimal and maximal values in different time periods RS 232/RS 485 communication up to 38400 bit/s or Ethernet communication MODBUS communication protocol Optional Protocol Modules Modbus TCP, BACNet IP, Profinet, SCADA EC61850 Configurable 2 x Tariff Inputs or 2 x Pulse Outputs, or Alarm Outputs Universal or AC/DC power supply Graphic Colour TFT 320 x 240 pixels (53x70mm) Automatic range of nominal current up to 6 A and nominal voltage up to 500 V Multilingual support User-friendly Free ECon Configuration software Specification Secure Part Number E500C-5202 Functions Power Quality Meter (31st Hamonic), Energy Meter, Network Recorder Supply Voltage Universal 35..300V DC, 85..300VAC Nominal Measurement Range 240V L-N, 1/5 Amp, 415V L-L 1/5 Amp Maximum Measurement Range 300V L-N, 1/5 Amp, 500V L-L 1/5 Amp Alarm Optional Module 2 Relay/Pulse Outputs Tariff/Digital Inputs TOU Tarriff Clock Accuracy Class 0.5S (I,U,F,PF,θ,THD) Class 1(Active), Class 2 (Reactive) Analogue Output Optional Module 2 x Programmable Analogue Outputs Internal Memory 2 x 8MB Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV RS232/RS485 N/A Optional CT Termination Ring Terminals Weight 600g Certification CE, CSA, ROHS Warranty 10 Years from dispatch from Secure Warehouse Factory Pack Qty 1 EU Directives Degree on electrical equipment designed for use within certain voltage limits URLRS 53/00 (Directive 73/23/EEC on low voltage): SIST EN 61010-1:2002 Safety Requirement for electrical equipment for measurement, control and laboratory use, part1 : general requirement Decree on electromagnetic Compatibility (EMC) URLRS 61/00 (Directive 89/336/EEC on electromagnetic compatibility): SIST EN 61036 item 4.5: 1998 Meters for active energy (class 1 and 2) Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP52 (IP00 for terminals) in compliance with SIST EN 60529:1997 Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C Datasheet Product Datasheet Cross Reference The Following meters are close equivalents to Elite 500 Series. For further details please contact Fastron Sales Team Elite 500_400_300_100 series competition replacement for Schneider Siemens Accuenergy (RS485 +DNP3 default) Socomec Selec PM 5000 series PAC 2000 series ACCUVIM-CL + DNP3.0 DIRIS A-20 Selec MFM376 PM 5100 PAC 3200 ACCUVIM-CL + DNP3.0 DIRIS A-20 MFM384, CL-1, RS485 PM 5300 ACCUVIM-IIR DIRIS A-20 MFM383A PM 5500 PAC 4200 ACCUVIM-IIR(+ BACnet) DIRIS A-20 MFM384. RS485 PM 6463 Siemens 7KMPAC4200 ACCUVIM-IIR (+ Profibus) DIRIS A-30/ DIRIS - A60 (PQ Feature) MFM384-C-CE-CL05, RS485 PM 5650 ACCUVIM-IIR (+ IEC 61850) DIRIS A-30 + Profibus MFM384-C-CE-CL05, RS485 PM 5760 ACCUVIM-EL DIRIS A-30 +Ethernet MFM384-C-CE-CL05, RS485 PM5330 ACCUVIM-EL (+ BACnet) DIRIS A-30/ DIRIS A-60 PM 5560 ACCUVIM-EL (+ Profibus) DIRIS A-30/ DIRIS A-60 DM6200H ACCUVIM-EL (+ IEC 61850) PM2220 ACCUVIM-II R +Ethernet PM2230 / DM2120 (LED) PM 5350
$725.00
$855.50 inclGST -
24870-702-01, Thyristor(SCR) PUK For Allen Bradley Softstarter , 58/26
Westcode-IXYS-Littlefuse 24870-702-01, Thyristor(SCR) PUK For Allen Bradley Softstarter , 58/26 Features Very low forward voltage drop Very low leakage current International standard package 58/26 Package Press Mounted Double or Single Sided Cooling Applications Power Supplies Rectifier for drives applications Uncontrolled Rectifiers Rectifiers for UPS Battery Chargers Field Supply for DC Motors Water Cooled Rectifiers DC Substation Blocking Diode Large Generators Specification Westcode Part Number 24870-702-01 Vrrm N/A Diode Configuration Thyristor Capsule (PUK) IF(av) @ 84 Deg C N/A Package Size ø58 x 26mm Itsm N/A Gate Terminals Faston Weight 600g Factory Pack Qty 6 Certification ROHS Westcode Headquarters UK Datasheet Heatsink Heatsink Profiles
$559.00
$659.62 inclGST -
SKiiP 22NAB126V10, 4 IGBT Trench 4 H Bridge with Chopper, 22Amp, 1200V
Semikron SKiiP 22NAB126V10, 4 IGBT Trench 4 H Bridge with Chopper, 22Amp, 1200V Features IGBT & Diode Rectifier with Chopper/Brake Pressure Contact Technology Electrically insulated base plate Press Mounted Style 2500V Isolation 61mm Base Width Applications Frequency Converter Line rectifying 50/60 Hz Deep Cycle Applications Controlled Rectifiers Inverter Drives Specification Semikron Part Number SKiiP 22NAB126V10 Vces 1200V Transistor Configuration H Bridge IGBT Module (4 Trench with Chopper) Ic(nom) @ 80 Deg C 22 Amp Package Size W:58.5mm L:51.5mm D:16mm Terminals Press Fit Mounting 1 x M12 Weight 100g Mounting Torque 5 Nm (4 Nm Terminals) Factory Pack Qty 10 Certification UL Listed, ROHS Semikron Headquarters Germany Datasheet Product Datasheet Alternatives No Alternative
$165.00
$194.70 inclGST -
2SP0320T2A0-12, Scale IGBT Driver for Various Individual, parallel, multilevel inverter topologies, 1200V IGBT Modules
Free Aus Post Shipping for $300 SpendPower Integrations 2SP0320T2A0-12, Scale IGBT Driver for Various Individual, parallel, multilevel inverter topologies, 1200V IGBT Modules Features Scale Driver Core ASIC based Plug and Play 1200V Rated UL approved Specifications Power Module Manufacturer Power Integrations Status Archived Product Type Driver Technology SCALE-1 Interface Standard Transformer Product Series 2SP0320T2A0 Power Module Part Number Any Power Module Package Any Channels 2 Voltage Class Value 1200V Output Power per Channel Value 3.00 UL Compliant compliant ROHS No Switching Frequency Value 100.00kHz Datasheet Product Datasheet
-
Thyro-A-1A-230-280-H3, Thyro-A-1A-Series Single Phase SCR Controller 280Amp 230VAC +10%/-57%, Voltage Control, Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes, Rating_280 Amp
Thyro-A-1A-230-280-H3, Thyro-A-1A-Series Single Phase SCR Controller 280Amp 230VAC +10%/-57%, Voltage Control, Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes, Rating_280 Amp Features Optional Profinet, Profibus, Ethernet, Modbus Comms 230VAC +10%/-57%, Voltage Control, +10/-57% Voltage, Current or Power Control Built in Fuse Smallest footprint on the market Single Phase Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes Quick TAKT Mode (QTM), VT Mode (on request) (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover Potentiometer Adjustment USB Configuration/Bias Setting Synchronisation Function (dASM Module Recommended) Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode AC Soft Starter (Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro-A-1A-230-280-H3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Single Phase AC Switch Control Modes Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request) Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1230 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 230VAC +10%/-57%, Voltage Control, +10/-15% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 30kg Factory Pack Qty 1 Technical Docs Brochure User Manual Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$2,483.80
$2,930.88 inclGST -
N1114LC160, Thyristor(SCR) PUK 756 Amp, 1600V, 58/26, T720N16TOF, Thyristor(SCR) PUK 720 Amp, 1600V, 58/26, See B1115LC180 or B1230LC160 for drop in replacement
Free Aus Post Shipping for $300 SpendWestcode-IXYS-Littlefuse N1114LC160, Thyristor(SCR) PUK 756 Amp, 1600V, 58/26, T720N16TOF, Thyristor(SCR) PUK 720 Amp, 1600V, 58/26, See B1115LC180 or B1230LC160 for drop in replacement Features Very low forward voltage drop Very low leakage current International standard package 58/26 Package Press Mounted Double or Single Sided Cooling Applications Power Supplies Rectifier for drives applications Uncontrolled Rectifiers Rectifiers for UPS Battery Chargers Field Supply for DC Motors Water Cooled Rectifiers DC Substation Blocking Diode Large Generators Specification Westcode Part Number N1114LC160 Vrrm 1600V Diode Configuration Thyristor Capsule (PUK) IF(av) @ 84 Deg C 756 Amp Package Size ø58 x 26mm Itsm 12.7 kA VF(to) 1V Tj(max) 125°C rF 0.349mΩ Gate Terminals Faston R th(j-k) (double sided cooled 180°sin) 0.018°C/W R th(c-h) (double sided cooled) Weight 340g Clamping Force 10 - 20kN Factory Pack Qty 6 Certification ROHS Westcode Headquarters UK Datasheet Product Datasheet Alternatives T720N16TOF Heatsink Heatsink Profiles
-
BSM100GB170DN2, IGBT Dual, 100Amp, 1700V. OBSOLETE. CLEARANCE PRICE
Free Aus Post Shipping for $300 SpendInfineon BSM100GB170DN2 IGBT Dual Module Features IGBT for Low Frequency Inverter Pressure Contact Technology Electrically insulated base plate Wide Temperature Range Medium Switching Speed 4000V Isolation 61mm Base Width Applications Frequency Converter Line rectifying 50/60 Hz Deep Cycle Applications Controlled Rectifiers Softstart AC motor control Low Frequency Inverter Drives Specification Infineon Part Number BSM100GB170DN2 Vces 1700V Transistor Configuration Dual IGBT Module (Half Bridge) Ic(nom) @ 80 Deg C 100 Amp Package Size W:61.4mm L:106.4mm D:30mm V(isol) 4.0 kV Vf @ 25 Deg C 2.3 - 2.8V Tj(max) 150°C Td(on) @ 25 Deg C 0.9uS Td(off) @ 25 Deg C 1.2uS I(ces) @ 25 Deg C 1mA Rcc 0.65mOhm Terminals M6 Screw Hole Centres 93 x 48mm(M6) Gate Terminals Spade (A 2.8 - 0.5mm) R th(j-c) 0.26°C/W R th(c-h) N/A Weight 400g Mounting Torque 4 Nm (4 Nm Terminals) Factory Pack Qty 10 Certification UL Listed, ROHS Infineon Headquarters Germany Datasheet Product Datasheet Alternatives , Obsolete. See BSM100GB170DN2 for posible replacement part or Contact Us for Possible Replacement for alternative
-
MC774 S HEWNNN, Power Quality Analyser Class A, 32uS sampling, 16-400Hz, Time Sychronisation support, 80-276VAC or 70-300VDC Power Supply, Three Independent Comm Ports, GPS, IRIG-B, and NTP Time, Up to 20 Input and Outputs, Ethernet and USB Comms
Free Aus Post Shipping for $300 SpendIskra Doo MC774 S HEWNNN, Power Quality Analyser Class A, 32uS sampling, 16-400Hz, 140 Parameter Measurement, Time Sychronisation support, 80-276VAC or 70-300VDC Power Supply, Three Independent Comm Ports, GPS, IRIG-B, and NTP Time, Up to 20 Input and Outputs, Ethernet and USB Comms, 1 x Status and 1 x Relay Output Class A Instrument Automatic range of nominal current up to 12.5 A (Includes 5A/1A CT Input) and nominal voltage up to 1000rms V L-N 50/60Hz Adjustable tariff clock, display of electric energy consumption in optional currency Optional RS 232/RS 485 communication up to 115,200 bit/s or Ethernet communication The POwer Quality Analyser is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : Measurement of instantaneous values of more than 140 quantities (U, I, P, Q, S, PF, PA, f, f, MD, energy, energy price by tariffs, etc.). Accuracy class 0.5 or 0.2 (on demand) Measurement of 40 minimal and maximal values in different time periods Optional 32 adjustable alarms Optional wide frequency range from 16 Hz to 400 Hz Optional RS 232/RS 485 communication up to 115,200 bit/s or Ethernet communication Optional MODBUS and DNP3 communication protocol MMC memory card for setting and upgrading the meter Up to 20 inputs or outputs (analogue outputs, pulse outputs, alarm outputs, tariff inputs) 1 Status and 1 Relay Output Universal or AC power supply Graphic LCD 128 x 64 dots with illumination Automatic range of nominal current up to 5 A and nominal voltage up to 750 V Adjustable tariff clock, display of electric energy consumption in optional currency Multilingual support User-friendly PC MiQen software 128 samples in one period Measurement of THD on Current or Voltage from 0 to 400% Measure to the 65th Harmonic Specification Iskra Doo Part Number MC774 S HEWNNNT Functions Power Quality Analyser, Energy Meter, Power Transducer, Network Recorder/Analyser Supply Voltage 240VAC < 5VA Nominal Measurement Range 750Vrms L-N, 5 Amp 50/60Hz Maximum Measurement Range 1000Vrms L-N, 12.5 Amp 50/60Hz Alarm N/A (Optional 4 Relays, 32 Alarms, 4 Groups) Analogue Output N/A (Optional 4 x 20mA) Digital Input N/A (Optional 4 x 230VAC/DC,75..130VAC/DC..5..48VAC/DC) Pulse Output N/A (Optional) Pulse Input N/A (Optional) Bistable Switch/Latching Relay Alarm N/A (Optional) Status (Watchdog) Output N/A (Optional) Tariff Input N/A (Optional 4 x 230VAC/DC,75..130VAC/DC..5..48VAC/DC) Accuracy Class 0.5 (I,U,F,PF,θ,THD) (Class 0.2 Optional) Class 1(Active), Class 2 (Reactive) Battery Backup Supercap Real Time Clock 1min/month (30ppm) Internal Memory 8MB MMC up to 1GB Isolation 3.7kV Ethernet Yes (RJ45 10/100Mbit/s) USB Yes (2400-115200 b/s) RS232/RS485 Optional Weight 600g Certification UL, CSA, ROHS Factory Pack Qty 1 EU Directives Degree on electrical equipment designed for use within certain voltage limits URLRS 53/00 (Directive 73/23/EEC on low voltage): SIST EN 61010-1:2002 Safety Requirement for electrical equipment for measurement, control and laboratory use, part1 : general requirement Decree on electromagnetic Compatibility (EMC) URLRS 61/00 (Directive 89/336/EEC on electromagnetic compatibility): SIST EN 61036 item 4.5: 1998 Meters for active energy (class 1 and 2) Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP52 (IP00 for terminals) in compliance with SIST EN 60529:1997 Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22 Datasheet Product Datasheet User Manual
-
N3533ZC220, Thyristor(SCR) 2320 Amp, 2200V 111/35, w/ 400mm Hard Soldered Gate Leads
Free Aus Post Shipping for $300 SpendWestcode-IXYS-Littlefuse N3533ZC220, Thyristor(SCR) 2320 Amp, 2200V 111/35, w/ 400mm Hard Soldered Gate Leads Features Very low forward voltage drop Very low leakage current International standard package 111/38 Package Press Mounted Double or Single Sided Cooling Applications Power Supplies Rectifier for drives applications Uncontrolled Rectifiers Rectifiers for UPS Battery Chargers Field Supply for DC Motors Water Cooled Rectifiers DC Substation Blocking Diode Large Generators Specification Westcode IXYS Part Number N3533ZC220 Vrrm 2200V Diode Configuration Thyristor Capsule (PUK) IF(av) @ 85 Deg C 2320 Amp Package Size ø111 x 38mm Itsm 50 kA VF(to) 0.93V Tj(max) 125°C rF 0.11mΩ Gate Terminals Hard wired Gate leads R th(j-c) (double sided cooled 180°sin) 0.0125°C/W R th(c-h) (double sided cooled) 0.003°C/W Weight 1.2kg Clamping Force 27 - 47kN Factory Pack Qty 12 Certification ROHS IXYS Headquarters USA Datasheet Product Datasheet Alternatives DCR3060V24 DCR3650Y28 Heatsink Heatsink Profiles
-
DPM96I310-2, 96mm x 96mm RED LED Digital AC Ammeter, 3 Phase 0-6 Amp CT Inputs, 0.5% Accuracy, 40 to 300VAC/DC Supply, IP54 (Optional IP65)
Free Aus Post Shipping for $300 SpendSecure Meters DPM96I310-2, 96mm x 96mm RED LED Digital AC Ammeter, 3 Phase 0-6 Amp CT Inputs, 0.5% Accuracy, 40 to 300VAC/DC Supply, IP54 (Optional IP65) Features LCD Dual Display 250mS Response Time PC 94 UL V0 Each unit needs just 96 x 96mm Panel Space 52mm Depth CE Approved ROHS and REACH Specification Secure Part Number DPM96I360-2 Frequency Range 45-65 Hz Accuracy 0.5% Input 0-6 Amp 3 Phase CT inputs Over Range x 1.5 Operating Temperature 0 - 60°C Supply Voltage 40-300VAC/DC Termination Style Screw Mounting Style 96 x 96mm Panel Mount Case Material PC - UL 94 V0 Standards IEC / EN 61010-1; IEC / EN 61010-2-030 Protection Degree IP54 (IP65 Optional) Weight 450g Factory Pack Qty 1 Datasheet Product Datasheet Manual DPM Series User Manual Application Notes Panel Meters Blog Articles
-
W3697VC160, Thyristor PUK, 2530 Amps @ 85 Deg C, 1600V, 101/34, Replaces N630CH30
Free Aus Post Shipping for $300 SpendWestcode-IXYS-Littlefuse W3697VC160, Thyristor PUK, 2530 Amps @ 85 Deg C, 1600V, 101/34, Replaces N630CH30 Features Very low forward voltage drop Very low leakage current International standard package 101/34 Package Press Mounted Double or Single Sided Cooling Applications Power Supplies Rectifier for drives applications Uncontrolled Rectifiers Rectifiers for UPS Battery Chargers Field Supply for DC Motors Water Cooled Rectifiers DC Substation Blocking Diode Large Generators Specification Westcode-IXYS-Littlefuse Part Number W3697VC160 Vrrm 1600V Diode Configuration Thyristor Capsule (PUK) IF(av) @ 84 Deg C 2530 Amp Package Size ø101 x 34mm Itsm 40 kA VF(to) 0.88V Tj(max) 160°C rF 0.1mΩ Gate Terminals Faston R th(j-k) (double sided cooled 180°sin) 0.016°C/W R th(c-h) (double sided cooled) Weight 1kg Clamping Force 27 - 34kN Factory Pack Qty 6 Certification ROHS Westcode Headquarters UK Datasheet Product Datasheet Alternatives Contact Us for Possible Replacement Replaces N630CH30 Heatsink Heatsink Profiles