Fastron Electronics SCT-F10-20-0.2V, 200mV, 20Amp measurement Split Core CT's Class 1 with 0.5M flying leads
Features
Quick Release Split Core System
Cable Mount
200mV Output
Self Powered
Rated System Voltage 0.60/3kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F10-20-0.2V
Technology
Split Core AC Current Transformer
Ratio
20/200mV
Aperture Size
ø 10 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
200mV (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
20Amp x 1.2
Termination Style
0.5M Flying Leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Fastron FDV-30-420-24, DC Voltage Transducer, Din Rail Mount, 0-30VDC, 4-20mA output, 24VDC Supply Voltage, 150mS Response
150mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 5V DC output (for voltage output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Part Number
FDV-30-420-24
Analogue Output
4-20mA
Input
0 - 30VDC
Measurement Range
120%
Overload
150% Continuous
Operating Temperature
-30 - 70°C
Operating Voltage
24VDC +/-15%
Voltage Isolation (1 min)
2.5kV
Accuracy
1%
Response Time
150mS
Termination Style
Screw
Mounting Style
DIN Rail Mount
Safety
CE, UL94V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron FRTD-Transmitter-0-400-420-24, Pt100 , 4-20mA Transmitter, 0 to 400 Deg C, 24VDC Supply
Class A Accuracy
Steel Insulated Cable
Low Long Term Drift
Rated for 0 to 220 Deg C Max
Spring Cable Connection
60mm Jaw Clip
Specification
Fastron Part Number
FRTD-Transmitter-0-400-420-24
Sensor Type
Pt100 to 4-20mA Transmitter
No of Wires
3
Shaft Length
N/A
Shaft Thickness
N/A
Accuracy
Class B
Temperature Range
0 to 400 Deg C
Span/ Zero Adjustment
YES
Weight
50g
Factory Pack Qty
1
Fastron FES521-FD-420E,Solid Core AC Current Transducer, Solid Core Multirange 0-10A,20A, 50A, Self Powered, Average RMS 4-20mA Output. 1% Accuracy (FCS521-SD-420E)
Compact and versatile current switches for detection of AC Currents, Multirange 0-10Amp, 0-20Amp, 0-50Amp via jumper, 4-20mA True RMS output
Features
Average RMS 4-20mA output
Multirange selector
Panel mounting
Eliminates insertion loss
Isolated plastic case recognised according to UL94-V0
Advantages
Highly accurate low current measurement down to 1Amp
High isolation between primary and secondary circuits
Easy installation
Applications
Fault Detection
Motor or Fan Protection
Application Domain
Energy and Automation
Specification
Fastron Part Number
FES521-FD-420E
Technology
Solid Core Solid Core AC Current Transducer
Range
0-10Amp, 0-20Amp, 0-50Amp via jumper
Supply Voltage
Self Powered
Load Current (RMS)
1Amp to 50 Amp
Output
4-20mA Average RMS
Isolation
2kV (AC, 50Hz, 1 min)
Bandwidth
50/60Hz
Mounting Style
Panel Mount
Operating Temperature Range
-25°C / 70°C
Accuracy
1%
Termination Style
Screw Terminals
Unit Weight
200g
Certifications
UL E320368, CE, Rohs compliant
Datasheet
Product Datasheet
Installation Guide
Advanced Energy Basic Bus & dASM Modules, 8 Channel Communication Interface for Thyro Series SCR Controllers
Note: Basicbus not required For Thyro PX Controllers, only requires Anybus and dASM (for Dynamic Mains load optimised Burst Fire Modes)
Optional Connection for up to 8 Power Controllers (32 Optional)
One Address per Module
Access to controller setpoints, actual points, and parameters
Transfer of setpoints as float number in physical units
Control Function of LED's
24VDC 200mA Supply
UL and CE Approved
Thyro S, Thyro A, Thyro AX
Note Requires Anybus Module for dASM Mode(TAKT Control Only)
Communication Options :
Ethernet (Inc Ethern/IP/Profinet/Modbus TCP
Profibus DPV1
Modbus RTU
DeviceNet
Specification
Advanced Energy Part Numbers
2.000.190.002,2.000.190.003
Functions
Access to controller setpoints, actual points, and parametersTransfer of setpoints as float number in physical unitsControl Function of LED's
Supply Voltage
24VDC
Protocols
EthernetIP, Profinet, Modbus TCP ProfibusDPV1, ModbusRTU, DeviceNet (with Suitable Anybus Module)
No. of Communication Ports
Up to 8
Weight
750g
Factory Pack Qty
1
Approvals
CE, UL
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
User Manual
User Guide
Blog for initial communication setup issue
Setting Up Comms on Thyro A Series Controllers
Thyro Touch Software and Touch Display User Guide
Anybus Device Ethernet IP Setup Guide
Trent MYG20-431 Series Metal Oxide Varistor (MOV), 275VAC, 350VDC, K20 Axial Package 105W, Replaces V275K20
High Energy Absorption Rating
Industry Standard Package
Wide Operating Range 35 - 1100VAC
High Peak Current Capability (70kA)
UL/CSA/ROHS/ISO9001:2015 Approved
Panel Mount
Screw Terminals
APPLICATION AREAS:
1. Railways and trams: For the protection of electrical equipment, power electronics (IGBT, thyristors...) in systems with alternating, direct or combined AC + DC power supply, especially in power supply of AC/DC, DC/AC, DC/DC converters. They may be used in systems with main and auxiliary power supply for example: automatic control and regulation systems, cooling systems, warming systems, ventilation systems, and combination systems (electromechanical, electropneumatic and other systems).
2. Wind powerplants For protection of automatic control and regulation in power electronics (IGTB, tyristors...), as well as the protection of sensitive electronic systems (e. g. AC/DC, DC/AC, DC/DC converters, drive systems) from direct or indirect lightning strikes.
3. Photovoltaic systems For protection of photopanels, automatic control electronics with sensitive electronic components, and DC/AC converters (inverters) from direct or indirect lightning strikes. Depending on the application, both serial and parallel connections are possible. With serial connection the required voltage is achieved. With parallel connection higher current absorption is achieved in the modules.
Specification
Trent Part Number
MYG20-431
Operating Voltage AC (50-60Hz)
275V
Operating Voltage DC
430V
Average Power Dissipation
1W
Permissable Peak Current
10kA
Energy Absorption(2ms)
167W(max)
Tolerance(Vn)
+/- 10%
Termination Style
Ring Lug
Weight
3g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CSA
Yes
Datasheet
Product Datasheet
Application Notes
Technical Blog MOV Article
F921 DC Series Current Transducer 100mA to 400 Amp Range with Adjustable High and Low C/O Relay Alarm
Features
Isolated measurement of DC currents using a Hall effect transducer with external aperture.
Incorporates an integrated input level display and power supply.
Wide measurement range available
Choice of standard outputs
Wide range isolated DC input supply
DIN Rail mounting
Signal Conditioned DC measurement output
On board bar graph display
User adjustable zero offset and span controls
Zero insertion loss in current measurement path
Earth leakage via differential Ipn for nominal Input ‘01’
Applications
Process control
Transportation
Petrochemical
Industrial
Earth Leakage
Energy Monitoring/Measurement
Automation
Delivery
Delivery in 3-5 days for small qty. Otherwise 4-6 weeks
Specification
Oztherm Part Number
F921-X-XX-DC-XX-XX
Functions
Single Phase AC Current Transducer
Supply Voltage
9-36VDC
Nominal Measurement Range
0-400 Amp (Sensor dependant)
Maximum Measurement Range
2500 Amp with External Sensor
Alarm
C/O Relay 4Amp @ 30VDC, 0.5Amp @ 150VAC
Response Time
250mS
Accuracy @ 25 Deg C
Class 1
Bandwidth
DC - 1kHz
linearity
< 0.15%
Isolation
2.5kV
Comms
N/A
Weight
250g
Enclosure Size
79 x 60 x 85mm
Factory Pack Qty
1
EU Directives
N/A
Safety
Protection Class II
600V rms, installation category II
300V rms, installation category III
Pollution Degree 2 in compliance with SIST EN 61010-1:2002
Enclosure Material
Polyamide non combustable-self-extinguishability, complying with UL 94 V-0
Enclosure Protection
IP40
Shock Withstand
300g 8ms Pulse . 6 Shocks in each of 3 axes
Vibration Withstand
0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
Fastron DTC1-A/M-TR, DIN Rail Mount Process Transmitter with Alarm Function, Multirange TC/RTD/4-20mA, 85-265VAC, 4-20mA output
Filter Time Constant Function
Converter function
2 Input 1 Output, and 1 Input Two Output Versions available
4-digit display. Suit most industries including Temperature, Humidity, Pressure (0.5s response)
CE Approved
Each unit needs just 22.5mm width Din Rail space
EC Compliant (Details)
Various specials available for unique applications.
Specification
Fastron Part Number
DTC1-A/M-TR
Transmitter Output
4-20mA
Input
Multirange RTD/K/J/R/S/B/E/T/4-20mA/N/W1/W2
Alarm
Relay 3A(Resistive), 1A(Inductive load cos ??=0.4), 240VAC/30VDC
Options
None
Mounting Style
22.5 x 75mm Din Rail Mount
Supply Voltage
85 - 265VAC
Termination Style
Screw
Weight
230g
Factory Pack Qty
1
CE
Yes
??
Selection Chart
Datasheet
DTC1 Brochure
DTC1User Manual
DTC1 User Manual Comms versions
Alarm Table
DTC1 (Program Control Version) User Manual
Fastron DTC1-A/M-2O, DIN Rail Mount Dual Transmitter Multirange Input, 85-265VAC, Dual 4-20mA Outputs
Optional converter function
2 Input 1 Output, and 1 Input Two Output Versions available
Optional 60 Segment Multi Pattern Program Control feature
4-digit display. Suit most industries including Temperature, Humidity, Pressure (0.5s response)
CE Approved
Each unit needs just 22.5mm width Din Rail space
EC Compliant (Details)
Various specials available for unique applications.
Specification
Fastron Part Number
DTC1-A/M-2O
Control Output
2 x 4-20mA outputs
Input
Multirange K/J/R/S/B/E/T/Linear Voltage Current(Optional)/N/W1/W2/Pt100
Alarm
Relay 3A(Resistive), 1A(Inductive load cos ??=0.4), 240VAC/30VDC
Options
Dual Output
Mounting Style
22.5 x 75mm Din Rail Mount
Supply Voltage
85 - 265VAC
Termination Style
Screw
Weight
230g
Factory Pack Qty
1
CE
Yes
??
Selection Chart
PWM Control Wiring
Datasheet
DTC1 Brochure
DTC1User Manual
DTC1 User Manual Comms versions
Alarm Table
DTC1 (Program Control Version) User Manual
NX4-20, Temp Controller, 48x48mm, 100-240VAC, Multirange Input, Multirange Relay/SSR/4-20mA Heating and Cooling Outputs, Setup for Relay Heating, SSR Cooling
Multirange Dual Output and Input, User Selectable
Multirange Output (Programmable)
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
UL/CE Approved
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 60 mm depth panel space
EC Compliant
Specification
Hanyoung Nux Part Number
NX4-20
Control Output 1 (Heat)
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4), or 4-20mA, or SSR (12VDC, 30mA 600 Ohm)
Control Output 2 (Cool)
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4), or 4-20mA, or SSR (12VDC, 30mA 600 Ohm)
Input
Multirange (refer to datasheet)
Alarm
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 1
2nd Alarm Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Mounting Style
48 x 48mm Panel Mount
Supply Voltage
85 - 265VAC
Termination Style
Screw
Weight
250g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Datasheet
NX Series Brochure
NX Series Instruction Manual
Free Software
Hanyoung Nux TCS Software
Hanyoung Nux TCS Software User Manual
VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
VX2-UCMD-A2CTD4H2R, Temp Controller, 48x96mm, 24VAC/DC, Multirange Input, 4-20mA Output, Relay Cooling Output, 2 Alarms, Retransmission, Event Input (2x SV), Remote Setting Input, Current Feedback
Multirange Input (Programmable)
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP65 (front panel only)
UL/CE Approved
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 60 mm depth panel space
EC Compliant
Specification
Hanyoung Nux Part Number
VX2-UCMD-A2CTD4H2R
Control Output 1 (Heat)
4-20mA
Control Output 2 (Cool)
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Input
Multirange Type K/J/E/T/R/B/S/L/N/U/W/PLII/PT100/JPT100/4-20mA/0-20mA/1-5V/0-5V/0-10V/0-50mV/0-100mV. Note for Direct Current Input please use 250 Ohm Resistor in Parallel to the input terminals.
Alarm
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 1
2 x Alarm Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 2
Event Input (2x SV), 4-20mA Remote Setting Input, Retransmission, Current Feedback
Mounting Style
48 x 96mm Panel Mount
Supply Voltage
24VAC/DC
Termination Style
Screw
Weight
350g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Datasheet
VX Series Brochure
VX Series Instruction Manual
Free Software
Hanyoung Nux TCS Software
Hanyoung Nux TCS Software User Manual
USB Driver (Windows 7) Not required for Windows 10 or 11