Search results for "텔레:bpmc55~`다이어트약마운자로처방"
-
110AF Series 690V 110 Amp, aR Semiconductor I²t Fuse BS88 Style 200kA Breaking
Trent 110AF Series 690V 110 Amp, aR Semiconductor I²t Fuse BS88 Style Features Equivalent to Bussmann 100FE, ETI BS17UQ/63/100A/690V British Standard Fuse Links Package Wide Range of I²t Ratings up to 1000 Amp Busbar or Standoff Mounting IEC Standard 60269.1 AND 4 690 V Voltage Rating complying with IEC 33 Applications Protection of High Powered Semiconductors according to I²t Short Circuit Protection DC or AC Motor I²t Protection Battery Fuse Specification Trent Part Number 110AF Fuse Type I²t AR Class Nominal Voltage 690VAC @ 50Hz I²t Rating (IP < 30IN) 5500 A²/s I²t Rating (IP > 30IN) 7840 A²/s Nominal Current (RMS + DC) 110 Amp Tested Breaking Capacity 200kA @ 690VAC Dimensions 17 x 49mm Hole Centers 60.9 - 65.6mm Mounting Style Busbar or Panel Mount with Standoff Operating Temperature Range -40°C / 125°C Watt Loss 26.5W Termination Style M6 Unit Weight 61g Factory Pack Qty 10 Datasheet Product Datasheet Cross Reference Chart
$45.70
$53.93 inclGST -
110BF Series 690V, 110 Amp aR Semiconductor I²t Fuse BS88 Style 200kA Breaking
Trent 110BF Series 690V, 110 Amp aR Semiconductor I²t Fuse BS88 Style Features Equivalent to Mersen 6.9 URGL 36/110 P097165 British Standard Fuse Links Package Wide Range of I²t Ratings up to 1000 Amp Busbar or Standoff Mounting IEC Standard 60269.1 AND 4 690 V Voltage Rating complying with IEC 33 Applications Protection of High Powered Semiconductors according to I²t Short Circuit Protection DC or AC Motor I²t Protection Battery Fuse Specification Trent Part Number 110BF Fuse Type I²t aR Class Nominal Voltage 690VAC @ 50Hz I²t Rating (IP < 30IN) 6000 A²/s I²t Rating (IP > 30IN) 6700 A²/s Nominal Current (RMS + DC) 110 Amp Tested Breaking Capacity 200kA @ 690VAC Dimensions 79.4 x 24 x 110mm Hole Centers 75.2 x 93.6mm Mounting Style Busbar or Panel Mount with Standoff Operating Temperature Range -40°C / 125°C Watt Loss 22.8W Termination Style M6 Unit Weight 220g Factory Pack Qty 10 Datasheet Product Datasheet Cross Reference Chart
$48.00
$56.64 inclGST -
125BF Series 690V, 125 Amp aR Semiconductor I²t Fuse BS88 Style 200kA Breaking
Trent 125BF Series 690V, 125 Amp aR Semiconductor I²t Fuse BS88 Style Features British Standard Fuse Links Package Wide Range of I²t Ratings up to 1000 Amp Busbar or Standoff Mounting IEC Standard 60269.1 AND 4 690 V Voltage Rating complying with IEC 33 Applications Protection of High Powered Semiconductors according to I²t Short Circuit Protection DC or AC Motor I²t Protection Battery Fuse Specification Trent Part Number 125BF Fuse Type I²t aR Class Nominal Voltage 690VAC @ 50Hz I²t Rating (IP < 30IN) 7900 A²/s I²t Rating (IP > 30IN) 8800 A²/s Nominal Current (RMS + DC) 125 Amp Tested Breaking Capacity 200kA @ 690VAC Dimensions 79.4 x 24 x 110mm Hole Centers 75.2 x 93.6mm Mounting Style Busbar or Panel Mount with Standoff Operating Temperature Range -40°C / 125°C Watt Loss 25W Termination Style M6 Unit Weight 220g Factory Pack Qty 10 Datasheet Product Datasheet Cross Reference Chart
$50.60
$59.71 inclGST -
150BBF Series 690V, 150 Amp aR Semiconductor I²t Fuse BS88 Style 200kA Breaking
Trent 150BBF Series 690V, 150 Amp aR Semiconductor I²t Fuse BS88 Style Features British Standard Fuse Links Package Wide Range of I²t Ratings up to 1000 Amp Busbar or Standoff Mounting IEC Standard 60269.1 AND 4 690 V Voltage Rating complying with IEC 33 Applications Protection of High Powered Semiconductors according to I²t Short Circuit Protection DC or AC Motor I²t Protection Battery Fuse Specification Trent Part Number 150BBF Fuse Type I²t aR Class Nominal Voltage 690VAC @ 50Hz I²t Rating (IP < 30IN) 12000 A²/s I²t Rating (IP > 30IN) 13900 A²/s Nominal Current (RMS + DC) 150 Amp Tested Breaking Capacity 200kA @ 690VAC Dimensions 79.4 x 24 x 110mm Hole Centers 75.2 x 93.6mm Mounting Style Busbar or Panel Mount with Standoff Operating Temperature Range -40°C / 125°C Watt Loss 45W Termination Style M6 Unit Weight 400g Factory Pack Qty 10 Datasheet Product Datasheet Cross Reference Chart
$102.30
$120.71 inclGST -
400NBF Semiconductor Fuse, 250VAC, 400 Amp, aR BS88 Style
Trent NBF Series 250VAC, 400 Amp Semiconductor I²t Fuse aR BS88 Style Features British Standard Fuse Links Package Wide Range of I²t Ratings up to 1050 Amp Busbar or Standoff Mounting IEC Standard 60269.1 AND 4 250 V Voltage Rating complying with IEC 33 Applications Protection of High Powered Semiconductors according to I²t Short Circuit Protection DC or AC Motor I²t Protection Battery Fuse Specification Trent Part Number 400NBF Fuse Type I²t AR Class Nominal Voltage 250VAC @ 50Hz I²t Rating 128000 A²/s Nominal Current (RMS + DC) 400 Amp Tested Breaking Capacity 200kA @ 250VAC Dimensions 82 x 47.3mm Hole Centers 65.5 - 48.2mm Mounting Style Busbar or Panel Mount with Standoff Operating Temperature Range -40°C / 125°C Watt Loss 47W Termination Style M6 Unit Weight 170g Factory Pack Qty 10 Datasheet Product Datasheet Cross Reference Chart
$41.40
$48.85 inclGST -
100AF Series 690V, 100 Amp aR Semiconductor I²t Fuse BS88 Style 200kA Breaking
Trent 100AF Series 690V, 100 Amp aR Semiconductor I²t Fuse BS88 Style Features Equivalent to Bussmann 100FE, ETI BS17UQ/63/100A/690V British Standard Fuse Links Package Wide Range of I²t Ratings up to 1000 Amp Busbar or Standoff Mounting IEC Standard 60269.1 AND 4 690 V Voltage Rating complying with IEC 33 Applications Protection of High Powered Semiconductors according to I²t Short Circuit Protection DC or AC Motor I²t Protection Battery Fuse Specification Trent Part Number 100AF Fuse Type I²t AR Class Nominal Voltage 690VAC @ 50Hz I²t Rating (IP < 30IN) 4800 A²/s I²t Rating (IP > 30IN) 6200 A²/s Nominal Current (RMS + DC) 100 Amp Tested Breaking Capacity 200kA @ 690VAC Dimensions 17 x 49mm Hole Centers 60.9 - 65.6mm Mounting Style Busbar or Panel Mount with Standoff Operating Temperature Range -40°C / 125°C Watt Loss 25W Termination Style M6 Unit Weight 61g Factory Pack Qty 10 Datasheet Product Datasheet Cross Reference Chart
$36.10
$42.60 inclGST -
300U60D, Rectifier Diode, 300 Amp, 600V, 3/4 UNF-2A, Cathode to stud
International Rectifier 300U60D, Rectifier Diode, 300 Amp, 600V, 3/4 UNF-2A, Cathode to stud Features Full blocking capability over wide temperature range Hermetic metal case with glass insulator Threaded stud Applications Power Supplies Uncontrolled Rectifiers Oil Cooled Circuits Battery Chargers Specification International Rectifier Part Number 300U60D Vrrm 600V Diode Configuration Cathode Stud IF(av) @ 100 Deg C 400 Amp IF(av) @ 150 Deg C 300 Amp Itsm 6.55 kA VF(to) 0.61V Tj(max) 200°C rF 0.751mΩ Termination Style (Tail) 8.3mm Round Lug Termination Style (Stud) 3/4" UNF Tail Length to Stud 149mm R th(j-c) 0.18°C/W R th(c-h) 0.08°C/W Weight 250g Mounting Torque 26 Nm Factory Pack Qty 8 Datasheet Product Datasheet
$45.00
$53.10 inclGST -
HS201DR, Panel and DIN Rail Mount Heatsink, 27 Amp @ 40 Deg C, 2°C/W
Crydom HS201DR, Panel and DIN Rail Mount Heatsink, 27 Amp @ 40 Deg C, 2°C/W Features DIN Rail or Panel Mount heat sink types Suitable for SSR Mounting Pre drilled for single or Dual SSR Black anodised for professional look Spec Crydom Part Number HS201DR Mounting Type Panel and Din Rail Mount Suitable SSR Rating 40/50 Amp Dimensions (without SSR) L:81mm x W:45mm x D:80mm Thermal Impedance 2°C/W Load Current @ 40 Deg C 28 Amp Load Current @ 50 Deg C 23 Amp Unit Weight 437g Factory Pack Qty 10 Datasheet Product Datasheet
$75.20
$88.74 inclGST -
HA4850E, Solid State Relay, Single Phase 18-36VAC Control, 50A, 48-530VAC Load
Crydom HA4850E, Solid State Relay, Single Phase 18-36VAC Control, 50A, 48-530VAC Load Features Ratings from 25A to 125 Amp @ 48-480VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CSA/VDE Approved, CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriers AC & DC control types Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Crydom Part Number HA4850E Switching Type Zero Crossing ROHS Yes (Details) Control Voltage 24VAC (18-36VAC) Load Current 50 Amp (rms) Surge Capability 597 Amp (peak) Special Feature None Mounting Style Panel Mount Load Voltage Range 48-530VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 75g Factory Pack Qty 20 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
$126.46
$149.22 inclGST -
Multicube Modular Measurement Module
Free Aus Post Shipping for $300 SpendNorthern Design Multicube Modular Single and 3 Phase Measurement Module Up to 20 Meters in 1 with additional modules. Requires multicube modular master unit Minimum 2 x 3 phase or 1 x single phase circuits with measurement module Alternative master with logger Optional pulse output modules Requires Multicube Modular Master or Multicube Master with Logger Optional 12 way pulse/alarm digital output modules Nominal current up to 0.383V (For 0.333V CT Input) and nominal voltage up to 240V L-N 415V L-L Graphic Display Optional RS485 or Ethernet communication up to 19,200 bit/s True RMS measurement of currents and voltages The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, reactive power, power factor, harmonics, etc.) from the measured signals. Features : Dual 3 phase Measurement Module 2 x 3 Phase or 6x Single Phase Circuits Accuracy class 1 Simple Menu Optional MODBUS RTU RS485 communication up to 19,200 bit/s or Ethernet communication 5 Year Warranty 240V AC power supply Specification Northern Design Part Number Multicube Modular Master Functions kWh Meter, Energy Meter, Power Quality Supply Voltage 240VAC < 15VA Nominal Measurement Range 415V L-L 240V L-N, 0.333V Maximum Measurement Range 480V L-L 280V L-N, 0.383V Display Graphic LCD Pulse Output 12 Accuracy Class 1 (kW,kWh) Class 1(Active), Class 2 Reactive Ethernet Optional Real Time Clock 1min/month (30ppm) Isolation 2.11kV RS232/RS485 N/A (Optional 2400-19200 b/s) Weight 150g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Environment IP54 Safety Protection Class II Enclosure Material ABS with fire protection to UL94-V-O. Self extinguishing EnclosureSize 164 x 96mm x 29mm Terminals Rising Cage 4mm² (12 AWG) cable max Humidity < 75% Non Condensing Operating Temperature -20 →+70 °C Datasheet Product brochure User manual Wiring Diagram Suitable 0.333V CT's Split Core CT's
Free Aus Post Shipping for $300 Spend$239.00
$282.02 inclGST -
Multicube Modular TCP/IP Comms Module NEW WEB PAGE VERSION
Free Aus Post Shipping for $300 SpendNorthern Design Multicube Modular TCP/IP Comms Module NEW WEB PAGE VERSION, with Internal logger Requires Multicube Modular Master or Multicube Master with Logger Up to 20 Meters in 1 with additional modules Minimum 2 x 3 Phase Circuits with measurement module Master Unit of Modular Multicube System Optional master with logger Optional 12 way pulse/alarm digital output modules Nominal current up to 0.383V (For 0.333V CT Input) and nominal voltage up to 240V L-N 415V L-L Graphic Display Modbus RTU Ethernet communication up to 19,200 bit/s True RMS measurement of currents and voltages The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, reactive power, power factor, harmonics, etc.) from the measured signals. NEW WEB PAGE VERSION Features : NEW WEB PAGE VERSION 20 Meters in same space as 4 traditional meters 20 x 3 Phase or 60 x Single Phase Circuits Accuracy class 1 Simple Menu MODBUS RTU RS485 communication up to 19,200 bit/s 5 Year Warranty 240V AC power supply Specification Northern Design Part Number Multicube Modular Master Functions kWh Meter, Energy Meter, Power Quality Supply Voltage 240VAC < 15VA Nominal Measurement Range 415V L-L 240V L-N, 0.333V Maximum Measurement Range 480V L-L 280V L-N, 0.383V Display Graphic LCD Pulse Output 12 (Optional) Accuracy Class 1 (kW,kWh) Class 1(Active), Class 2 Reactive Ethernet 2400-19200 b/s Real Time Clock 1min/month (30ppm) Isolation 2.11kV RS232/RS485 Optional Weight 175g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Environment IP54 Safety Protection Class II Enclosure Material ABS with fire protection to UL94-V-O. Self extinguishing EnclosureSize 164 x 96mm x 29mm Terminals Rising Cage 4mm² (12 AWG) cable max Humidity < 75% Non Condensing Operating Temperature -20 →+70 °C Datasheet Product brochure User manual Wiring Diagram Suitable 0.333V CT's Split Core CT's
Free Aus Post Shipping for $300 Spend$949.00
$1,119.82 inclGST -
FESCT-32-400-0.333V, 400Amp measurement Split Core CT's, Class 1, w/1M Flying leads, 32x32mm Aperture
Fastron Electronics FESCT-32-400-0.333V, 400Amp measurement Split Core CT's, w/1M Flying leads, 32x32mm Aperture, 0.333v Class 1 Series Current Transformer Features Quick Release Split Core System 1m Flying Leads Mounting Feet Supplied Self Powered Rated System Voltage 0.60/2kV Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FESCT-32-400-0.333V Technology Split Core AC Current Transformer Ratio 400/0.333V Aperture Size 32 x 32mm VA Rating N/A Accuracy Class Class 1 Output 0.333VAC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 55°C Continuous Current (max) 400Amp x 1.2 Termination Style 1M Twisted Pair 0.34mm^2 Unit Weight 350g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide
$80.00
$94.40 inclGST